Leviton OSSNL-IDI Installation guide

Type
Installation guide

Leviton OSSNL-IDI is a single-pole designer wall switch occupancy sensor with an LED nightlight that automatically switches lights on and off based on motion detection. It features adjustable time-delay settings from 30 seconds to 2 hours and a fully adjustable LED nightlight with continuous or dim mode. Perfect for hospitality and healthcare facilities, it offers both auto ON and manual ON settings for added convenience.

Leviton OSSNL-IDI is a single-pole designer wall switch occupancy sensor with an LED nightlight that automatically switches lights on and off based on motion detection. It features adjustable time-delay settings from 30 seconds to 2 hours and a fully adjustable LED nightlight with continuous or dim mode. Perfect for hospitality and healthcare facilities, it offers both auto ON and manual ON settings for added convenience.

Single Pole (One Location) or Multi-Location
Designer Wall Switch Occupancy Sensor with LED NightLight
California Title 24 2005 Compliant
Cat. No. OSSNL/OSSNL-INx/OSS10-IDx
No Minimum Load Required
Compatible with incandescent lamps, electronic and magnetic low-voltage ballasts, electronic and magnetic ballasts, and fans
INSTALLATION INSTRUCTIONS
Incandescent: 800W @ 120V Fluorescent: 1200VA @ 120V Fluorescent: 2700VA @ 277V Supplemental: 1/4hp @ 120V
PK-93369-10-00-0B
WARNINGS AND CAUTIONS:
• Tobeinstalledand/orusedinaccordancewithappropriateelectricalcodesandregulations.
• Ifyouareunsureaboutanypartoftheseinstructions,consultanelectrician.
• Controllingaloadinexcessofthespeciedratingswilldamagetheunitandposeriskofre,electricshock,personalinjuryordeath.
Checkyourloadratingstodeterminesuitabilityforyourapplication.
• Donotinstallthisunittocontrolareceptacle.
WARNINGS AND CAUTIONS:
• Disconnectpoweratcircuitbreakerorfusewhenservicing,installingorremovingxture.
• Donottouchthesurfaceofthelens.Cleanoutersurfacewithadampclothonly.
• TheOSSNL/OSSNL-INx/OSS10-IDxOccupancySensorisintendedtoreplaceastandardlightswitch.
• Usethisdevicewith copper or copper clad wire only.WithaluminumwireuseonlydevicesmarkedCO/ALRorCU/AL.
WARNING: TO AVOID FIRE, SHOCK, OR DEATH;
TURN OFF POWER atcircuitbreakerorfuseandtestthat
power is off before wiring!
Step 1
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&/./&&
/./&&
/./&&
/./&&
/./&&
1- #12 w/ 1 to 3 #14, #16 or #18
2- #12 w/ 1 or 2 #16 or #18
1- #14 w/ 1 to 4 #16 or #18
2- #14 w/ 1 to 3 #16 or #18
WIRE NUT / # OF COND.
COMBINATION CHART
For non-standard wiring applications, refer
to Wire Nut and Conductor Size Chart
• Pulloffpre-cutinsulationfromsensorleads.
• Makesurethattheendsofthewiresfromthewallboxarestraight
(cut if necessary).
• Removeinsulationfromeachwireinthewallboxasshown.
Preparing and connecting wires:
5/8"
(1.6 cm)
Strip Gage
(measure bare
wire here)
Cut
(if necessary)
Step 3
Features
DESCRIPTION
LevitonCat.No.OSSNL/OSSNL-INx/OSS10-IDx,DesignerWall
SwitchOccupancySensorwithLEDNightLight,isdesignedto
detect motion from a heat-emitting source (such as a person
enteringaroom)withinitseld-of-view(monitoredspace)and
eitherautomaticallyormanuallyswitcheslightsONandOFF
(OSSNL-INx)ormanuallyswitcheslightsONandautomatically
switcheslightsOFF(OSS10).Thecontrolledlightswillremain
ONuntilnomotionisdetectedandthescheduledtime-delayhas
expired.TheLEDNightLightoperatesseparatelyfromcontrolled
roomlightsandwillturnONviaaphotocellwhentheambientlight
inthespaceisapproximatelylessthan1footcandleandturnOFF
whentheambientlightexceeds5footcandles.TheLEDNightLight
isadjustableforcontinuousmodeoradimmode.Inthedimmode
theLEDdimstoapproximately5%offullbrightnessafter2minutes
ofnooccupancy.WheninthemanualONswitchmode,theLED
NightLightwillfadeupandreturntotheadjustablesettingwhen
occupancyisdetectedandtheambientlightlevelpresenttothe
photocellislessthan1footcandle.TheLEDNightLightconsumes
lessthanonehalfofawattprovidingenergysavingsandguide
lightingwhenroomlightsareoff.TheLEDNightLightoutputisfully
adjustablewithasimpledialsetting.
OSSNL-IDxisperfectforuseinhospitalityandhealthcare
facilitieswitheitherautoONormanualONsettingswithadjustable
time-delaysettingsof30secondsto2hourswithLEDNightLight.
TheOSS10workswellanywhereamanualONonlyoccupancy
sensorwithLEDNightLightisdesiredandhasamaximumof
30minutetime-delaysettingtoconformtoCaliforniaTitle24
requirements.BothsensorsareULlistedandhavealimited5-year
warranty.
PASSIVE INFRARED (PIR) TECHNOLOGY DESCRIPTION
TheOccupancySensorsensesmotionwithinitscoverageareaof
1200sq.ftmaximumandcontrolstheconnectedlighting.Thisisa
self-containeddevicewhichprovidessensingandlightcontrol.The
OccupancySensorwillturnthelightsONwhenmotionisinitially
detected(OSSNL-INxOnly),andkeepthelightsONforaslong
asmotionisdetected.TheOSS10isamanualONdevicewith
automaticOFFwhennooccupancyisdetected.
TheOccupancySensorusesasmallsemiconductorheatdetector
thatresidesbehindamulti-zoneopticallens.ThisFresnellens
establishesdozensofzonesofdetection.TheSensorissensitive
totheheatemittedbythehumanbody.Inordertotriggerthe
Sensor, the source of heat must move from one zone of detection
toanother.Thedeviceismosteffectiveinsensingmotionacross
itseld-of-view,andlesseffectivesensingmotiontowardsoraway
fromitseld-of-view(refer to Field-of View diagrams).Keepthis
inmindwhenselectingtheinstallationlocation.
NOTE:Dresswireswithabendasshownindiagramtorelieve
stresswhenmountingdevice.
Positionallwirestoprovideroominoutletwallboxfordevice.
• Partiallysecuredeviceusinglongmountingscrewsprovided.
• Restorepoweratcircuitbreakerorfuse.
• TheLEDindicatorwillashafterpowerisapplied.Allow
approximtely30secondsforcharge-up.After30secondsthe
lightswillturnON.IfthelightsturnONandtheLEDblinks
when a hand is waved in front of the lens, then the Sensor was
installedproperly.
If lights do not turn ON, refer to the TROUBLESHOOTING
section.
NOTE:Cat.No.OSSNL/OSSNL-INx/OSS10-IDxisfactory
presettoworkwithoutanyadjustments.Ifyoudesiretochange
thefactorysettings,refer to FEATURES AND SETTINGS
section).
NOTE:ToavoidPERMANENTDAMAGEtotheunit,becareful
NOTTOOVERTURNthecontrolknobsorleverswhensetting
theSensor.Thecontrolscanbeaccessedbyremovingthe
wallplate (if applicable) and control panel cover (refer to Sensor
Features Diagram).Useasmallstraightbladescrewdriverto
adjustknobsandblinderlevers.
NOTE: DO NOTpressinonblinderleversoruseexcessive
force (refer to Sensor Features Diagram).
•AttachtheControlPanelcoverwhenthedesiredsettingsare
complete.
FEATURES AND SETTINGS:
BLINDERS:Theblinderscannarrowtheeld-of-viewofthedevice
topreventunwantedactivationfromtrafcinadjacentspace.There
aretwoblinders,andeachoperateindependently.Tooperatethe
blinders,useangerorsmallscrewdrivertomovetheblinder
adjustmentleverstowardorawayfromthecenterofthedevice.
Theblinderleversarefoundabovethecontrolknobsandbelowthe
text‘BLINDERS’onthecontrolpanel.Withbothleversmovedfully
towardsthecenter,theeld-of-viewisnarrowedto32°.Withboth
leversmovedfullyawayfromthecenter,theeld-of-viewisata
maximum180°(refer to Sensor Features Diagram).
WIRING SENSOR:
Connect wires per WIRING DIAGRAM as follows:
Screwwireconnectoronclockwisemakingsuretherearenobare
conductorsbelowthewireconnectors.Secureeachconnectorwith
electricaltape.
• GreenorbarecopperwireinwallboxtoGreenlead.
• LineHotwallboxwiretoBlacklead.
• LoadwallboxwiretoBluelead.
• LineNeutralwallboxwiretoWhitelead.
NOTE: Allow approximately 30 seconds for warm-up after connected.
Black (Hot)
Neutral (White)
Load
Sensor
Black
Black
White
White
Blue
Green
Ground
Line
120/277VAC, 60Hz
2
1
Sensor
Black
White
Blue
Green
4
3
Installing your Sensor -
Single-Pole Application:
NOTE: Sensor requires a neutral connection in order
tooperate.Usethegroundwireintheelectriclboxfor
groundconnection.Ifthereisnogroundwire,ensure
electricalboxisgroundedandattachgroundwiretobox
withascrew.
Step 4
INSTALLING YOUR SENSOR
NOTE:UsecheckboxeswhenStepsarecompleted.
Sensor 1
2
Black
White
Blue
Green
2
Sensor 2
Black
White
Blue
Green
1
4
5
3
5
1
4
3
Installing your Sensor -
3-Way Wiring Application:
NOTE: Sensor requires a neutral connection in order
tooperate.Usethegroundwireintheelectricalboxfor
groundconnection.Ifthereisnogroundwire,ensure
electricalboxisgroundedandattachgroundwiretobox
withascrew.
Step 5
Step 2
2
4
1
3
2
4
1
5
3
3-Way
1. Line or Load
(See *IMPORTANT instruction)
2. Neutral
3. Ground
4. FirstTraveler–notecolor
5. SecondTraveler–notecolor
Single-Pole
1.Line(Hot)
2.Neutral
3.Ground
4. Load
Identifying your wiring application
(most common):
NOTE:Ifthewiringinthewallboxdoesnotresemblethis
conguration,consultaqualiedelectrician.
*IMPORTANT:For3-Wayapplications,notethatoneofthescrew
terminalsfromtheoldswitchbeingremovedwillusuallybeadifferent
color(Black)orlabeledCommon.Tagthatwirewithelectricaltapeand
identifyasthecommon(LineorLoad)inbothswitchwallboxes.
NOTE: Sensor 1 mustbeinstalledinawallboxthathasbothaLINE
HotandaNeutralconnection.Sensor2mustbeinstalledinawallbox
thathasbothaLoadandaNeutralconnection.
Ifyouareunsureaboutanypartoftheseinstructions,consulta
qualiedelectrician.
WIRING SENSOR 1:
Connect wires per WIRING DIAGRAM as follows:
Screwwireconnectoronclockwisemakingsuretherearenobare
conductorsbelowthewireconnectors.Secureeachconnectorwith
electricaltape.
• GreenorbarecopperwireinwallboxtoSensor1Greenlead.
• LineHot(common)wallboxwireidentied(tagged)whenremoving
oldswitchandFirstTravelerfromSensor2toSensor1Blacklead.
• SecondTravelerwallboxwirefromSensor2toSensor1Bluelead.
• LineNeutralwallboxwiretoSensor1Whitelead.
WIRING SENSOR 2:
Connect wires per WIRING DIAGRAM as follows:
Screwwireconnectoronclockwisemakingsuretherearenobare
conductorsbelowthewireconnectors.Secureeachconnectorwith
electricaltape.
• GreenorbarecopperwireinwallboxtoSensor2Greenlead.
• Loadwallboxwireidentied(tagged)whenremovingoldswitch
andSecondTravelerfromSensor1toSensor2Bluelead.
• FirstTravelerLineHotfromSensor1toSensor2Blacklead.
• SecondTravelerwallboxwirefromSensor2toSensor1Bluelead.
• LineNeutralwallboxwiretoSensor2Whitelead.
NOTE: Allow approximately 30 seconds for warm-up after connected.
Black (Hot)
Neutral (White)
Load
Sensor 2Sensor 1
Black
Black
Black
White
White
Blue
White
Blue
Green
Ground
Green
Ground
Line
120/277VAC, 60Hz
Wall surface
Sensor
Mounting
screws
(2 places)
Testing your Sensor prior to completely
mounting in wall box:
Step 6
• Leviton’sDecora
®
styledesign
• WhiteLEDNightLightfunctionwithOccupancySensor
• NightLightActivateswhenLowAmbientLightPresent
• AdjustableNightLightLevels
• AutoON/OFF(OSSNL-INx)andManualON/AutoOFF(OSS10)
DESCRIPTION cont'd
Notethatoccupancysensorsrespondtorapidchangesin
temperature,socareshouldbetakennottomountthedevice
nearaclimatecontrolsource(i.e.radiators,airexchanges,andair
conditioners).Hotorcolddraftswilllooklikebodymotiontothedevice
andwilltriggeritiftheunitismountedtooclose.Itisrecommended
tomounttheOccupancySensoratleast6ft.awayfromtheclimate
controlsource.Thedevicecanbemountedinasinglegangwallbox.
Inaddition,itisalsorecommendedNOTtomounttheOccupancy
Sensordirectlyunderalargelightsource.Largewattagebulbs
(greater than 100W incandescent) give off a lot of heat and switching
thebulbcausesatemperaturechangethatcanbedetectedbythe
device.MounttheOccupancySensoratleast6ft.awayfromlarge
bulbs.Ifitisnecessarytomountthedevicecloser,lowerthewattage
ofthebulbdirectlyoverhead.
Slotted/PhillipsScrewdriver ElectricalTape Pliers
Pencil Cutters Ruler
Tools needed to install your Sensor
Insertwires
straight
then twist
clockwise
Electrical
Tape
Insertwires
straight
then twist
clockwise
Electrical
Tape
OPERATION
PUSH-BUTTON:Cat.No.OSSNL/OSSNL-INx/OSS10-IDxhasa
push-button switch that toggles the lights (refer to gure).Ifthe
lightsareOFF,thelightswillturnONwhenthebuttonispressed,and
remainONinthepresenceofmotion.Intheabsenceofmotion,the
SensorUnitwilltime-outandturnthelightsOFF.
IfthelightsareON,thelightswillturnOFFwhenthebuttonispressed.
ThelightswillstayOFFregardlessofmotiondetected,untilthetime-
outexpires.Afterthetime-outexpires,thelightswillturnON(Auto-ON
Modeonly)withthenextdetectedmotion.Thisisusefulforslideor
lmpresentations.
NOTES:
• TheMotionIndicatorLEDwillblinkevery2secondswhilemotionis
detected.
• InManual-ONmode,thebuttonmustbepressedtoturnthe
lightsON.
PRODUCT INFORMATION
• Fortechnicalassistancecontactusat1-800-824-3005
• Visitourwebsiteatwww.leviton.com
PK-93369-10-00-0B
Field-of-View (Horizontal)
20 ft (6.1 m)
small motion
30 ft (9.1 m)
20 ft (6.1 m)
small motion
40 ft
(12.2 m)
Side (Vertical) Field-of-View
27 ft.
(8.2 m)
38 ft.
(11.7 m)
4 ft.
(1.2 m)
4.5 ft.
(1.4 m)
1
0
8.3
0
Sensor Unit
• Securedevicebyrmlytighteningmountingscrews.
• InstallDecora
®
stylewallplate(soldseparately).
Sensor and Wallplate Mounting:
Step 7
Wall surface
Device mounting screw
(2 places)
Wallplate
Wallplate
mounting
screw
(2 places)
Sensor Features Diagram
Lens with
PIR and LED
NightLight
Blinders
Control Panel
Cover
Push Button
LED
Indicator
Step 6 cont’d
Testing your Sensor prior to
completely mounting in wall box:
FEATURES AND SETTINGS:
TIME-DELAY:Cat.No.OSSNL/OSSNL-INx/OSS10-IDxwillturn
lightsONwhenmotionisdetected.Whenmotionisnolonger
detected,theSensorUnitwillwaitacertainamountoftimeand
thenturnthelightsOFF.Thiswaittimeiscalled‘time-out’.
The“time-out”isselectedfromfour(4)presetvalues.Pointingthe
arrowatoneofthemarkingsonthefacechoosesthevalueoftime.
ThebuttonLEDindicatorlightwillashtwicewhenthetimesetting
haschanged.Thefollowingselectionsareavailable:
OSSNL-IDx: Face Marking Value of Time
NOTE:The“time-out”isfactorypresettothirty(30)minutes
(refer to Sensor Features Diagram).
NOTE: All time durations mentioned in the instructions are
approximatewithin10seconds.
OSS10-IDx: Face Marking Value of Time
NOTE: The“time-out”isfactorypresettoten(10)minutes
(refer to Sensor Features Diagram).
NOTE: All time durations mentioned in the instructions are
approximatewithin10seconds.
RANGE:Todecreasedetectionrangeandsensitivity,rotatethe
knobcounter-clockwise(refer to Sensor Features Diagram).The
detectionsrangecanbeadjustedfrom100%downto35%.
MANUAL-ON MODE (OSSNL-INx ONLY):Thefactorydefault
settingfortheOSSNLisManual-ON.Tochangethissettingto
Auto-ON/OFF,turnthedialmarked“ONMODE/NLDIM”clockwise
anywhereintotheareathatindicates“AUTO”.Toreturnto
Manual-ON,turnthedialcounter-clockwiseanywhereintothearea
thatindicates“MAN”.
NOTE:OSS10isaManual-ONsettingonly.
NIGHTLIGHT:TheOSSNL/OSSNL-INx/OSS10-IDxrespondsto
theambientlightlevelpresentinaroom.TheOSSNL/OSSNL-INx/
OSS10-IDxusesaninternalphotocelltodetectwhentheambient
lightlevelisapproximatelylessthan1footcandleactivatingthe
LEDNightLight.Further,theinternalphotocellwillturnOFFthe
LEDNightLightwhenitdetectsanambientlightlevelover5foot
candles.TheLEDNightLighthasadjustablelightoutputtomeetthe
needs of the space and can be set to for continuous mode or dim
modewhichwillautomaticallydimto5%offullbrightnessafter2
minutesofnooccupancy.
NIGHTLIGHT DIM:ToadjusttheLEDNightLightoutput,turnthe
dialmarked“ONMODE/NLDIM”(OSSNL-INx)or“NITELITEDIM”
(OSS10)counter-clockwisetodecreaseandclockwisetoincrease
lightoutput.
NIGHTLIGHT MODE:Thefactorydefaultsettingforthe
NightLightModeisdimmedmode.ThismeanstheLEDNightLight
automaticallydimsto5%offullbrightnessafter2minutesofno
occupancywhenactivatedbytheinternalphotocell.Tochangethe
NightLightModeperformthefollowingprocedure:
1. Press and hold the push button for 2 seconds to determine the
currentmode.
a. NightLightashesonceevery1secondforContinuousMode
untilthebuttonisreleased.
b. NightLightashestwiceevery1secondforDimModeuntil
thebuttonisreleased.
2.Tochange,holdthepushbuttonfor10secondsandtheMode
willtoggle.Thiswillbeindicatedbyachangeintheashpattern
asdescribedabove.
TROUBLESHOOTING
1.Ifthereisnoresponsefromtheunit(thelightneverturnsONand
theLEDneverblinks)11/2minutesafterpowerisapplied,then
uninstalldeviceandverifythereisagroundconnectionatthe
wallbox.Ifthereisagroundconnection,verifywiring.
2.IfthelightsneverturnON,buttheLEDblinks,checkifthe
Manual-ONsetting(OSSNLonly).SeeManual-ONModesettingfor
adjustments.
3.IfthelightsconstantlystayON,evenwhentheroomisunoccupied:
A.ChecktheTimesetting.Seehowthistimecomparestohow
longthelightsstayON.
B.TryloweringtheRangeControl.Rotatetheknobcounter-
clockwiseabout30°.
C.Iftheproblempersists,tryreducingagain.
NOTE:DoNotreducesomuchthatCat.Nos.
OSSNL/OSSNL-INx/OSS10-IDxcannotseenormaloccupancy.
D.BesuretousetheBlinderstoblockanyunwanted
hallwaytrafc.
E.Checkforreectedheat/motionasSensorUnitmaybeseeing
motionthroughawindow.
F. CheckforadjacentHVACand/orheaterducts.
NOTES
Cat. No. OSSNL
Cat. No. OSS10
TIME
NITELITE DIM
MIN MAX
Blinder adjustment levers
BLINDERS
Control Panel Cover
10M
30S
20M
30M
RANGE
4
7
10
30S
30M
1H
2H
30secondxedtime-outforperformingawalktest
30 minute time-out
1 hour time-out
2 hour time-out
Value of TimeFace Marking
30S
10M
20M
30M
30secondxedtime-outforperformingawalktest
10 minute time-out
20 minute time-out
30 minute time-out
Value of TimeFace Marking
©2009LevitonMfg.Co.,Inc.
FCC COMPLIANCE STATEMENT
ThisdevicecomplieswithPart15oftheFCCRules.Operationis
subjecttofollowingtwoconditions:(1)thisdevicemaynotcause
harmfulinterference,and(2)thisdevicemustacceptanyinterference
received,includinginterferencethatmaycauseundesiredoperationof
thedevice.
Thisequipmenthasbeentestedandfoundtocomplywiththelimits
foraClassBDigitalDevice,pursuanttoPart15oftheFCCRules.
Theselimitsaredesignedtoprovidereasonableprotectionagainst
harmfulinterferenceinaresidentialinstallation.Thisequipment
generates,uses,andcanradiateradiofrequencyenergyand,ifnot
installedandusedinaccordancewiththeinstructions,maycause
harmfulinterferencetoradiocommunications.However,thereisno
guaranteethatinterferencewillnotoccurinaparticularinstallation.If
this equipment does cause harmful interference to radio or television
reception,whichcanbedeterminedbyturningtheequipmentOFFand
ON,theuserisencouragedtotrytocorrecttheinterferencebyoneor
moreofthefollowingmeasures:
• ReorientorrelocatethereceivingAntenna.
• Increasetheseparationbetweentheequipmentandthereceiver.
• Connecttheequipmentintoanoutletonacircuitdifferentfromthat
towhichthereceiverisconnected.
• Consultthedealeroranexperiencedradio/tvtechnicianforhelp.
FCC CAUTION
AnychangesormodicationsnotexpresslyapprovedbyLeviton
ManufacturingCo.,Inc.,couldvoidtheuser'sauthoritytooperatethe
equipment.
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
LevitonwarrantstotheoriginalconsumerpurchaserandnotforthebenefitofanyoneelsethatthisproductatthetimeofitssalebyLevitonisfreeofdefectsinmaterialsandworkmanshipundernormalandproperuseforfiveyearsfromthepurchasedate.Leviton’sonlyobligationistocorrectsuchdefectsbyrepairorreplacement,atitsoption,ifwithinsuchfiveyearperiodtheproductisreturnedprepaid,with
proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, New York 11747.Thiswarrantyexcludesandthereisdisclaimedliabilityforlaborforremovalofthisproductorreinstallation.Thiswarrantyisvoidifthisproductisinstalledimproperlyorinanimproperenvironment,overloaded,misused,opened,
abused,oralteredinanymanner,orisnotusedundernormaloperatingconditionsornotinaccordancewithanylabelsorinstructions.There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose,butifanyimpliedwarrantyisrequiredbytheapplicablejurisdiction,thedurationofanysuchimpliedwarranty,includingmerchantabilityandfitnessfora
particularpurpose,islimitedtofiveyears.Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation.Theremediesprovidedhereinaretheexclusiveremediesunderthiswarranty,whetherbasedoncontract,tortorotherwise.
  • Page 1 1
  • Page 2 2

Leviton OSSNL-IDI Installation guide

Type
Installation guide

Leviton OSSNL-IDI is a single-pole designer wall switch occupancy sensor with an LED nightlight that automatically switches lights on and off based on motion detection. It features adjustable time-delay settings from 30 seconds to 2 hours and a fully adjustable LED nightlight with continuous or dim mode. Perfect for hospitality and healthcare facilities, it offers both auto ON and manual ON settings for added convenience.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI