CARTER-HOFFMANN HBU5A2GM Operating instructions

Type
Operating instructions
LOGIX
1,
LOGIX
2,
LOGIX
3 &
LOGIX
4 Series
ALUMINUM HEATED HOLDING
CABINETS & HEATER PROOFERS
OWNERS / OPERATORS MANUAL
Part Number: 18400-3130c Printed in The United States of America Rev: KBA100710
TABLE OF CONTENTS
SAFETY PRECAUTIONS……………………………..…………………. 2
FEATURES & SPECIFICATIONS………..……………..………………. 3-6
UNPACKING, INSPECTION & FREIGHT DAMAGE…………………. 7
INSTALLATION & STARTUP …………………….……………………. 8
DETAILS: CONTROLS AND WATER PANS………………………….. 9
NORMAL OPERATION: LOGIC1 & 3 HB HEATED CABINETS……. 10
NORMAL OPERATION: LOGIC2 & 4 HW HEATER PROOFERS …. 11
FOOD HOLDING GUIDE………………………………………………... 12
DAILY CLEANING PROCEDURES...………………..………………... 13
CABINET MAINTENANCE………………………………………………. 14
WIRING DIAGRAMS...……………………………………… …………... 15
REPLACEMENT PARTS………………………………………………... 16
TROUBLESHOOTING GUIDE …………………………………………. 17
WARRANTY STATEMENT……….……………….……………………. 18
MANUFACTURED BY:
CARTER-HOFFMANN
1551 McCormick Avenue
Mundelein, IL 60060 U.S.A.
Phone: 847-362-5500
Fax: 847-367-8981
Toll Free: 800-323-9793
Email: Service@Carter-Hoffmann.com
HBF18A2GM
MODELS:
LOGIX1 HEATED
CABINETS
(non-insulated)
HBU5A2GM
HBU8A2GM
HBU14A2GM
HBU18A2GM
HBC10A2GM
HBC16A2GM
HBC28A2GM
HBC36A2GM
HBF5A2GM
HBF8A2GM
HBF14A2GM
HBF18A2GM
MODELS:
LOGIX2 HEATER/
PROOFERS
(non-insulated)
HWU5A2GM
HWU8A2GM
HWU14A2GM
HWU18A2GM
HWC10A2GM
HWC16A2GM
HWC28A2GM
HWC36A2GM
HWF5A2GM
HWF8A2GM
HWF14A2GM
HWF18A2GM
MODELS:
LOGIX3 HEATED
CABINETS
(insulated)
HBU5A1GM
HBU8A1GM
HBU14A1GM
HBU18A1GM
HBC10A1GM
HBC16A1GM
HBC28A1GM
HBC36A1GM
HBF5A1GM
HBF8A1GM
HBF14A1GM
HBF18A1GM
MODELS:
LOGIX4 HEATER/
PROOFERS
(insulated)
HWU5A1GM
HWU8A1GM
HWU14A1GM
HWU18A1GM
HWC10A1GM
HWC16A1GM
HWC28A1GM
HWC36A1GM
HWF5A1GM
HWF8A1GM
HWF14A1GM
HWF18A1GM
2
WARNING: ELECTRIC SHOCK HAZARD
All service requiring access to non-insulated components must be performed by
qualified service personnel. Failure to heed this warning may result in severe
electric shock.
CAUTION: ELECTRIC SHOCK HAZARD
Disconnect this appliance from electrical power before performing any
maintenance or service.
CAUTION: BURN HAZARD
Exposed metal surfaces can be hot to the touch and may cause burns.
SAFETY PRECAUTIONS
WAR NING
NOTE: The technical content of this manual, including any wiring diagrams, schematics, parts breakdown
illustrations and/or adjustment procedures, is intended for use by qualified technical personnel and is
subject to change without notice.
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances basic safety precautions should be followed, including the following:
1) Be familiar with the appliance use, limitations and associated restrictions. Operating instructions must
be read and understood by all persons using or installing this appliance.
2) This appliance must be grounded. Connect only to properly grounded outlet.
3) Use this appliance only for its intended purpose as described in the manual.
a. This equipment is specifically designed to hold pre-cooked food at temperature.
b.
This equipment is intended for use in commercial establishments only.
c. This equipment is not designed for industrial or laboratory use.
4) Cleanliness of this appliance and its accessories is essential to good sanitation.
5) DO NOT submerge this appliance in water. This appliance is not jet stream approved. DO NOT direct
water jet or steam jet at this appliance, or at any control panel or wiring. DO NOT splash or pour
water on, in or over any controls, control panel or wiring. DO NOT use corrosive chemicals or vapors
in this appliance.
6) DO NOT store this appliance outdoors. DO NOT use this product near water – for example,
near a kitchen sink, in a wet basement, or near a swimming pool, and the like.
7) DO NOT operate this appliance if it has a damaged cord or plug, if it is not working properly, or if it has
been damaged or dropped. Do not immerse cord or plug in water, keep cord away from heated
surfaces, and do not let cord hang over edge of table or counter.
8) DO NOT cover or block any openings on the appliance.
9) Only qualified service personnel should service this appliance.
3
LOGIX1 NON-INSULATED ALUMINUM HEATED CABINET FEATURES & SPECIFICATIONS
Model
Number
Pan/Tray
Capacity*
12”x20” 18”x26”
Slide Pairs
Provided
Overall Dimensions
Height Depth Width
in (mm)
Caster
Diameter
in (mm)
Class 100
Shipping
Weight
lbs (kgs)
HBU5A2GM
(under-counter)
10 5 5 31-1/16 29-1/2 24-11/16
(789) (749) (627)
5
(127)
108
(49)
HBC10A2GM
(under-counter)
- 10 10 31-1/16 29-1/2 24-11/16
(789) (749) (627)
5
(127)
95
(43)
HBF5A2GM
(under-counter)
10 5 5 31-1/16 29-1/2 24-11/16
(789) (749) (627)
5
(127)
99
(45)
HBU8A2GM
(1/2 size)
16 8 8 40-1/16 29-1/2 24-11/16
(1018) (749) (627)
5
(127)
149
(68)
HBC16A2GM
(1/2 size)
- 16 16 40-1/16 29-1/2 24-11/16
(1018) (749) (627)
5
(127)
131
(59)
HBF8A2GM
(1/2 size)
16 8 8 40-1/16 29-1/2 24-11/16
(1018) (749) (627)
5
(127)
137
(62)
HBU14A2GM
(3/4 size)
28 14 14 58-1/16 29-1/2 24-11/16
(1474) (749) (627)
5
(127)
168
(76)
HBC28A2GM
(3/4 size)
- 28 28 58-1/16 29-1/2 24-11/16
(1474) (749) (627)
5
(127)
148
(67)
HBF14A2GM
(3/4 size)
28 14 14 58-1/16 29-1/2 24-11/16
(1474) (749) (627)
5
(127)
155
(70)
HBU18A2GM
(full size)
36 18 18 70-1/16 29-1/2 24-11/16
(1780) (749) (627)
5
(127)
215
(97)
HBC36A2GM
(full size)
- 36 36
70-1/16 29-1/2 24-11/16
(1780) (749) (627)
5
(127)
185
(84)
HBF18A2GM
(full size)
36 18 18 70-1/16 29-1/2 24-11/16
(1780) (749) (627)
5
(127)
198
(90)
* HWU Standard spacing at 3”, adjustable on 1-1/2” centers. HWC standard spacing fixed at 1-1/2”, HWF fixed spacing at 3”
LOGIX1 Features & Benefits
Precision-engineered bottom mount heater with superior heat-up and recovery time
Analog heat control. Digital thermometer. Temperature range of 90°- 190°F
Four sizes, available with adjustable universal, fixed universal or adjustable universal slides
All swivel heavy-duty casters, front casters fitted with brakes
Field reversible glass door in heavy-duty extruded aluminum frame is standard, black anodized solid aluminum
door is optional
Cabinets with Adjustable Universal, Fixed Universal or Angle Slides
APPROVALS:
3174974
Conforms to UL Std 197
certified to CAN/CSA Std
C22.2 No. 109
3174974
Conforms to
NSF/ANSI
Std 4
4
LOGIX2 NON-INSULATED ALUMINUM HEATER/PROOFER FEATURES & SPECIFICATIONS
Model
Number
Pan/Tray
Capacity*
12”x20” 18”x26”
Slide Pairs
Provided
Overall Dimensions
Height Depth Width
in (mm)
Caster
Diameter
in (mm)
Class 100
Shipping
Weight
lbs (kgs)
HWU5A2GM
(under-counter)
10 5 5 31-1/16 29-1/2 24-11/16
(789) (749) (627)
5
(127)
108
(49)
HWC10A2GM
(under-counter)
- 10 10 31-1/16 29-1/2 24-11/16
(789) (749) (627)
5
(127)
95
(43)
HWF5A2GM
(under-counter)
10 5 5 31-1/16 29-1/2 24-11/16
(789) (749) (627)
5
(127)
99
(45)
HWU8A2GM
(1/2 size)
16 8 8 40-1/16 29-1/2 24-11/16
(1018) (749) (627)
5
(127)
149
(68)
HWC16A2GM
(1/2 size)
- 16 16 40-1/16 29-1/2 24-11/16
(1018) (749) (627)
5
(127)
131
(59)
HWF8A2GM
(1/2 size)
16 8 8 40-1/16 29-1/2 24-11/16
(1018) (749) (627)
5
(127)
137
(62)
HWU14A2GM
(3/4 size)
28 14 14 58-1/16 29-1/2 24-11/16
(1474) (749) (627)
5
(127)
168
(76)
HWC28A2GM
(3/4 size)
- 28 28 58-1/16 29-1/2 24-11/16
(1474) (749) (627)
5
(127)
148
(67)
HWF14A2GM
(3/4 size)
28 14 14 58-1/16 29-1/2 24-11/16
(1474) (749) (627)
5
(127)
155
(70)
HWU18A2GM
(full size)
36 18 18 70-1/16 29-1/2 24-11/16
(1780) (749) (627)
5
(127)
215
(97)
HWC36A2GM
(full size)
- 36 36
70-1/16 29-1/2 24-11/16
(1780) (749) (627)
5
(127)
185
(84)
HWF18A2GM
(full size)
36 18 18 70-1/16 29-1/2 24-11/16
(1780) (749) (627)
5
(127)
198
(90)
* HWU Standard spacing at 3”, adjustable on 1-1/2” centers. HWC standard spacing fixed at 1-1/2”, HWF fixed spacing at 3”
LOGIX2 Features & Benefits
Precision-engineered bottom mount heater with superior heat-up and recovery time
Analog heat and humidity levels. Digital thermometer. Temperature range of 90°- 190°F
Can be operated with or without humidity. Capable of humidified holding as well as proofing
Four sizes, available with adjustable universal, fixed universal or adjustable universal slides
All swivel heavy-duty casters, front casters fitted with brakes
Field reversible glass door in heavy-duty extruded aluminum frame is standard, black anodized solid aluminum
door is optional
Cabinets with Adjustable Universal, Fixed Universal or Angle Slides
APPROVALS:
3174974
Conforms to UL Std 197
certified to CAN/CSA Std
C22.2 No. 109
3174974
Conforms to
NSF/ANSI
Std 4
5
LOGIX3 INSULATED ALUMINUM HEATED CABINET FEATURES & SPECIFICATIONS
Model
Number
Pan/Tray
Capacity*
12”x20” 18”x26”
Slide Pairs
Provided
Overall Dimensions
Height Depth Width
in (mm)
Caster
Diameter
in (mm)
Class 100
Shipping
Weight
lbs (kgs)
HBU5A1GM
(under-counter)
10 5 5 31-5/8 31-1/2 26-1/2
(803) (800) (673)
5
(127)
113
(51)
HBC10A1GM
(under-counter)
- 10 10 31-5/8 31-1/2 26-1/2
(803) (800) (673)
5
(127)
100
(45)
HBF5A1GM
(under-counter)
10 5 5 31-5/8 31-1/2 26-1/2
(803) (800) (673)
5
(127)
104
(47)
HBU8A1GM
(1/2 size)
16 8 8 40-5/8 31-1/2 26-1/2
(1032) (800) (673)
5
(127)
159
(72)
HBC16A1GM
(1/2 size)
- 16 16 40-5/8 31-1/2 26-1/2
(1032) (800) (673)
5
(127)
141
(64)
HBF8A1GM
(1/2 size)
16 8 8 40-5/8 31-1/2 26-1/2
(1032) (800) (673)
5
(127)
147
(67)
HBU14A1GM
(3/4 size)
28 14 14 58-5/8 31-1/2 26-1/2
(1489) (800) (673)
5
(127)
183
(83)
HBC28A1GM
(3/4 size)
- 28 28 58-5/8 31-1/2 26-1/2
(1489) (800) (673)
5
(127)
163
(74)
HBF14A1GM
(3/4 size)
28 14 14 58-5/8 31-1/2 26-1/2
(1489) (800) (673)
5
(127)
170
(77)
HBU18A1GM
(full size)
36 18 18 70-5/8 31-1/2 26-1/2
(1794) (800) (673)
5
(127)
235
(107)
HBC36A1GM
(full size)
- 36 36 70-5/8 31-1/2 26-1/2
(1794) (800) (673)
5
(127)
205
(93)
HBF18A1GM
(full size)
36 18 18 70-5/8 31-1/2 26-1/2
(1794) (800) (673)
5
(127)
218
(99)
* HWU Standard spacing at 3”, adjustable on 1-1/2” centers. HWC standard spacing fixed at 1-1/2”, HWF fixed spacing at 3”
LOGIX3 Features & Benefits
Precision-engineered bottom mount heater with superior heat-up and recovery time
Analog heat control. Digital thermometer. Temperature range of 90°- 190°F
Four sizes, available with adjustable universal, fixed universal or adjustable universal slides
All swivel heavy-duty casters, front casters fitted with brakes
Field reversible glass door in heavy-duty extruded aluminum frame is standard, black anodized solid
aluminum door is optional
Cabinets with Adjustable Universal, Fixed Universal or Angle Slides
APPROVALS:
3174974
Conforms to UL Std 197
certified to CAN/CSA Std
C22.2 No. 109
3174974
Conforms to
NSF/ANSI
Std 4
6
LOGIX4 INSULATED ALUMINUM HEATER/PROOFER FEATURES & SPECIFICATIONS
Model
Number
Pan/Tray
Capacity*
12”x20” 18”x26”
Slide Pairs
Provided
Overall Dimensions
Height Depth Width
in (mm)
Caster
Diameter
in (mm)
Class 100
Shipping
Weight
lbs (kgs)
HWU5A1GM
(under-counter)
10 5 5 31-5/8 31-1/2 26-1/2
(803) (800) (673)
5
(127)
113
(51)
HWC10A1GM
(under-counter)
- 10 10 31-5/8 31-1/2 26-1/2
(803) (800) (673)
5
(127)
100
(45)
HWF5A1GM
(under-counter)
10 5 5 31-5/8 31-1/2 26-1/2
(803) (800) (673)
5
(127)
104
(47)
HWU8A1GM
(1/2 size)
16 8 8 40-5/8 31-1/2 26-1/2
(1032) (800) (673)
5
(127)
159
(72)
HWC16A1GM
(1/2 size)
- 16 16 40-5/8 31-1/2 26-1/2
(1032) (800) (673)
5
(127)
141
(64)
HWF8A1GM
(1/2 size)
16 8 8 40-5/8 31-1/2 26-1/2
(1032) (800) (673)
5
(127)
147
(67)
HWU14A1GM
(3/4 size)
28 14 14 58-5/8 31-1/2 26-1/2
(1489) (800) (673)
5
(127)
183
(83)
HWC28A1GM
(3/4 size)
- 28 28 58-5/8 31-1/2 26-1/2
(1489) (800) (673)
5
(127)
163
(74)
HWF14A1GM
(3/4 size)
28 14 14 58-5/8 31-1/2 26-1/2
(1489) (800) (673)
5
(127)
170
(77)
HWU18A1GM
(full size)
36 18 18 70-5/8 31-1/2 26-1/2
(1794) (800) (673)
5
(127)
235
(107)
HWC36A1GM
(full size)
- 36 36 70-5/8 31-1/2 26-1/2
(1794) (800) (673)
5
(127)
205
(93)
HWF18A1GM
(full size)
36 18 18 70-5/8 31-1/2 26-1/2
(1794) (800) (673)
5
(127)
218
(99)
* HWU Standard spacing at 3”, adjustable on 1-1/2” centers. HWC standard spacing fixed at 1-1/2”, HWF fixed spacing at 3”
LOGIX4 Features & Benefits
Precision-engineered bottom mount heater with superior heat-up and recovery time
Analog heat and humidity levels. Digital thermometer. Temperature range of 90°- 190°F
Can be operated with or without humidity. Capable of humidified holding as well as proofing
Four sizes, available with adjustable universal, fixed universal or adjustable universal slides
All swivel heavy-duty casters, front casters fitted with brakes
Field reversible glass door in heavy-duty extruded aluminum frame is standard doors are standard, solid aluminum
door is optional
Cabinets with Adjustable Universal, Fixed Universal or Angle Slides
APPROVALS:
3174974
Conforms to UL Std 197
certified to CAN/CSA Std
C22.2 No. 109
3174974
Conforms to
NSF/ANSI
Std 4
7
UNPACKING AND INSPECTION
1. Remove the cabinet from shipping carton, ensuring that all pack-
ing materials and protective plastic has been removed from the
unit.
2. Inspect all components for completeness and condition.
3. If any freight damage is present, a freight claim must be filed im-
mediately with the shipping company.
4. Freight damage is not covered under warranty.
5. Check to insure all components are included: cabinet, instruction
packet and additional accessories.
6. Read operation instructions completely.
7. Appliance should be thoroughly cleaned before use. See
CLEANING INSTRUCTIONS in this manual.
This appliance
should be
thoroughly
cleaned prior to use.
See the CLEANING
INSTRUCTIONS in
this manual.
NOTE: DO NOT discard
the carton or other
packing materials until
you have inspected the
appliance for hidden
damage and checked it
for proper operation.
Refer to SHIPPING
DAMAGE CLAIM
PROCEDURE on
bottom of this page.
FREIGHT DAMAGE PROCEDURE
NOTE: For your protection, please note that equipment in this shipment was carefully inspected
and packaged by skilled personnel before leaving the factory. Upon acceptance of this shipment,
the transportation company assumes full responsibility for its safe delivery.
IF SHIPMENT ARRIVES DAMAGED:
1. VISIBLE LOSS OR DAMAGE: Be certain that any visible loss or damage is noted on the freight
bill or express receipt, and that the note of loss or damage is signed by the delivery person.
2. FILE CLAIM FOR DAMAGE IMMEDIATELY
: Regardless of the extent of damage. Contact
your dealer immediately.
3. CONCEALED DAMAGE: If damage is unnoticed until the merchandise is unpacked, notify the
transportation company or carrier immediately, and then file a “CONCEALED DAMAGE” claim
with them. This should be done within fifteen (15) days from the date the delivery was made to
you. Be sure to retain the container for inspection.
Carter-Hoffmann cannot assume liability for damage or loss incurred in transit, freight damage is
not covered under warranty. We will, however, at your request, supply you with the necessary
documents to support your claim.
8
LOCATION
For proper operation and maximum performance, locate the
unit in an ambient air temperature of 70ºF (21ºC).
Avoid placement in areas near exhaust fans or where there
are active air movements.
For safe operation and maximum performance, locate the
unit at least 2” from any wall or combustible material.
Unit must be on a solid level surface.
INSTALLATION AND STARTUP
GROUNDING INSTRUCTIONS
This appliance is equipped with a cord having a grounding
wire with a grounding plug which must be plugged into an
outlet that is properly installed and grounded. In the event of
an electrical short circuit, grounding reduces the risk of elec-
tric shock by providing an escape wire for the electric current.
WARNING—Improper use of the grounding can result in
a risk of electric shock. Consult a qualified electrician or
service agent if the grounding instructions are not completely
understood, or if doubt exists as to whether the appliance is
properly grounded.
If necessary, contact a licensed
electrician to install an appropriate
20 amp electrical circuit with correct
NEMA receptacle.
DO NOT use an extension cord.
Installation procedures must be
performed by a qualified technician
with full knowledge of all applicable
electrical codes. Failure could
result in personal injury and prop-
erty damage.
Damage to unit due to being
connected to the wrong voltage or
phase is NOT covered by warranty.
START UP
1. Prior to use, thoroughly clean the interior of the unit, per
the instructions in this manual. Familiarize yourself with
the controls.
2. Plug the power cord of the cabinet into a grounded outlet
with a electrical service according to the electrical infor-
mation provided below. DO NOT MODIFY CORD PLUG.
3. Set POWER switch to the “ON” position.
4. Do not load product into the cabinet. Allow the heat to
remove any residual oils which may adhere to inside
metal surfaces. A slight emission of smoke is common
during the first few hours of operation.
T
he ground prong of the power
cord is part of a system designed to
protect you from electric shock in
the event of internal damage.
DO NOT cut off the large round
ground prong or twist a blade to fit
an existing receptacle.
CAUTION:
Electrical Shock Hazard
Unit is not waterproof, to avoid
electrical shock, keep unit from be-
ing submerged in water. Do not
operate if unit has been in contact
with water.
IMPORTANT:
Power cord is 8' long
IMPORTANT:
Not under warranty
WARNING:
Risk of personal injury
WARNING:
Risk of personal injury
LOGIC1 & LOGIC3 Models
beginning with HB
LOGIC2 & LOGIC4 Models
beginning with HW
DETAILS: CONTROL PANELS & WATER PANS
LOGIX1 & LOGIX3 HB Series Heated Holding Cabinets
LOGIX2 & LOGIX4 HW Series Heater/Proofer Cabinets
9
ON/OFF power switch
and indicator light
Heat control knob. Settings from 1 (low heat) to 7 (high heat)
Heating element cycle light
Digital temperature read-out
ON/OFF power switch
and indicator light
Heat control knob. Settings from
1 (low heat) to 7 (high heat)
Heating element cycle light
Digital temperature
read-out
Humidity control knob. Settings from
1 (low humidity) to 7 (high humidity)
Humidity element cycle light
Humidity pan (manual fill): check and fill every 2 hours
when operating cabinet with humidity
Water trough for condensation: collects and deposits
condensation into pan below
Condensation pan: check and empty periodically
WATER PAN LOCATIONS
X
X
10
NORMAL OPERATION—LOGIX1 & LOGIX3 HB HEATED CABINETS
CAUTION:
HOT SURFACE
Inner and outer surfaces of
the unit will be very hot dur-
ing and after operation.
Avoid touching the cabinet
when loading or removing
product.
FIRST USE
Before using the cabinet, familiarize yourself with the heater con-
trols. See page 9 for details. Plug the cabinet into a proven power
source. See electrical specifications on page 8.
HOLDING
1. Turn the cabinet on using the power switch located on the far left
side of the control panel. Once the switch is turned on, the
power indicator light will illuminate.
2. A water pan is provided in the base of the cabinet to provide a
small amount of passive humidity, if desired. Fill pan with clean
warm water. Check water level every 2 hours and refill as
needed. This step is optional; cabinet be also be operated
without water in the pan.
3. To adjust the temperature setting, rotate the HEAT dial clock-
wise to increase temperature and counter-clockwise to decrease
temperature to the desired set point. Temperature dial settings
range from 1 to 7, with 1 being the lowest temperature and 7
being the highest temperature. HEAT cycle light will turn on and
off as the heat thermostat cycles.
4. Wait approximately 25 minutes for the cabinet to preheat. Digital
readout dial on right side of control panel will display actual
cabinet temperature*.
5. Load food pans into cabinet. NOTE: Follow all food safety guide-
lines. Put hot, cooked food into the cabinet. This cabinet is not
intended to reheat food. Food must be cooked and at safe serv-
ing temperature prior to being placed in the cabinet.
6. When removing items, start at the bottom and work up. This will
keep food hotter and eliminate spillage onto lower items.
Operating ranges:
- air temp: 90ºF-190ºF
*For food safety reasons,
it is recommended that
the holding temperature
be set at 140°F or higher.
X
11
NORMAL OPERATION—LOGIX2 & LOGIX4 HW HEATER PROOFERS
CAUTION:
HOT SURFACE
Inner and outer surfaces of
the unit will be very hot dur-
ing and after operation.
Avoid touching the cabinet
when loading or removing
product.
FIRST USE
Before using the cabinet, familiarize yourself with the heater con-
trols. See page 9 for details. Plug the cabinet into a proven power
source. See electrical specifications on page 8.
HOLDING
1. If humidity is desired, a water pan is located at the bottom of the
cabinet. This pan will provide active humidification up to 90%RH
(depending on temperature). Fill water pan with clean warm
water. NOTE: Cabinet may also be operated without water.
2. Turn the cabinet on using the power switch located on the far left
side of the control panel. Once the switch is turned on, the
power indicator light will illuminate.
3. To adjust the temperature setting, rotate the HEAT dial clock-
wise to increase temperature and counter-clockwise to decrease
temperature to the desired set point. Temperature dial settings
range from 1 to 7, with 1 being the lowest temperature and 7
being the highest temperature.
4. To adjust humidity, rotate the humidity dial clockwise to
increase humidity and counter-clockwise to decrease humidity.
If humidity is not required, rotate dial counter-clockwise to the off
position (line up dot on knob with white hash mark on control
panel).
5. Wait approximately 25 minutes for the cabinet to preheat. Digital
readout dial on right side of control panel will display actual
cabinet temperature*.
6. Load food pans into cabinet. NOTE: Follow all food safety guide-
lines. Put hot, cooked food into the cabinet. This cabinet is not
intended to reheat food. Food must be cooked and at safe
serving temperature prior to being placed in the cabinet.
7. When removing items, start at the bottom and work up. This will
keep food hotter and eliminate spillage onto lower items.
PROOFING
1. Follow instructions above for holding. Note: water pan at base
of cabinet must be filled with clean warm water.
2. For proofing settings, rotate HEAT knob clockwise to 3.5 to 4
(approximately 90°F to 100°F) and rotate HUMIDITY knob clock-
wise to 7 (90%+ RH).
3. Allow cabinet to preheat for approximately 25 minutes and load
food according to the instructions above.
Operating ranges:
- air temp: 90ºF-190ºF
- humidity: 0-90%RH
Water reservoir:
When using the water reser-
voir for humidified holding or
proofing, check water level
every 2 hours and refill if
needed.
CAUTION:
WATER HAZARD
A water trough is located at
the base of the cabinet to
collect and direct condensa-
tion into black plastic con-
densation pan below. Make
sure to periodically check
and empty the pan to avoid
overflow & slip hazard.
*For food safety reasons,
we recommend that the
holding temperature
should be set at or above
140°F.
X
12
FOOD HOLDING GUIDE
NOTE: Times and temperatures
observed in a test kitchen environ-
ment. Times and temperatures
may vary, depending on initial food
quality, initial cooked temperature
and user expectations of accept-
able food quality.
PRODUCT SET TEMPERATURE
(°F /°C)
MAXIMUM TIME
(MINUTES)
Bacon, Canadian 180°F / 82°C 30
Bacon, Crisp (uncovered) 180°F / 82°C 30
Baked Potato 180°F / 82°C 60
Biscuits 170°F / 77°C 60
Casseroles 175°F / 79°C 90
Chops, Sliced Meats 160°F / 71°C 60
Chicken, Fried (uncovered) 170°F / 77°C 30
Chicken, Boneless Breasts 175°F / 79°C 60
Chicken Nuggets, Deep Fried (uncovered) 190°F / 88°C 25
Chicken, Pre-Cooked Grilled Boneless Patties 150°F / 66°C 90
Coffee Cakes (uncovered) 170°F / 77°C 60
Cookies (uncovered) 175°F / 79°C 90
Crab Legs 160°F / 71°C 45
Croissants 170°F / 77°C 45
Eggs 160°F / 71°C 45
Fish, Deep-Fried (uncovered) 170°F / 77°C 30
Fish, Baked 155°F / 68°C 45
Fish, Broiled 155°F / 68°C 45
French Toast 165°F / 74°C 60
Gravies / Sauces 170°F / 77°C 45
Hamburgers / Ground Meat Patties 180°F / 82°C 45
Hot Dogs 180°F / 82°C 90
Muffins 170°F / 77°C 60
Omelets 160°F / 71°C 30
Pancakes 180°F / 82°C 30
Pasta 175°F / 79°C 60
Pastries 165°F / 74°C 30
Pizza (uncovered) 180°F / 82°C 15
Pizza (boxed) 180°F / 82°C 60
Poppers, Deep Fried (uncovered) 190°F / 88°C 25
Poultry, Whole, bone-in 175°F / 79°C 60
Poultry, Cut-up, bone-in 175°F / 79°C 60
Ribs 175°F / 79°C 90
Rice 175°F / 79°C 30
Roasts / Bone-in Meats 165°F / 74°C 90
Sausage 180°F / 82°C 90
Shrimp / Shellfish 150°F / 66°C 60
Soups (broth) 185°F / 85°C 90
Tortillas (soft) 180°F / 82°C 60
Vegetables 175°F / 79°C 45
CAUTION: SAFE
FOOD HOLDING
PRACTICES
RECOMMENDED
Cooking food to a safe tem-
perature, holding at a tem-
perature of at least 140°F is
critical in the prevention of
foodborne illness. Hold only
cooked, hot food at 140°F
or higher. This cabinet is
not intended to cook or re-
heat food. Food must be at
appropriate temperature
before being placed into
cabinet.
140°F
41°F
DANGER ZONE: 41°F
to 140°F Bacteria
grow rapidly
COOK TO AT LEAST
165°F Destruction of
most bacteria
165°F
HOLD at 140°F or higher
13
DAILY CLEANING PROCEDURES
1. After all food products have been removed from the cabinet,
turn the power switch to “OFF” and allow the cabinet to cool
completely.
2. Unplug the unit prior to any cleaning.
3. Remove the rack assemblies.
4. Make sure the power cord is not hooked into the cord hook.
Open cabinet door and empty water reservoir. Remove the
heater module by lifting up the front enough to clear its detent,
and then pull the module out of the cabinet. The power cord
will slide through the access hole at the rear of the cabinet.
5. Inspect and clean the areas where there are vents or filters,
making sure no water gets into the internal controls or
electrical areas of the cabinet.
6. Clean the inside of the cabinet as well as the removed parts.
Reinstall when all parts are dry and clean. Empty and clean
black plastic condensation pan.
7. A solution of two tablespoons of baking soda per quart of
warm water is sufficient for most cleaning jobs. Mild soap or
detergent may be used on heavily soiled interiors—follow
manufacturer’s directions.
8. If cabinet has a clear glass door, clean with window cleaner,
taking care not to get any of the solution on the aluminum
cabinet walls. Stubborn deposits may be cleaned with a mild
soap and water and then rinsed with clean water. Use a soft,
non-abrasive cloth to avoid scratching the door.
9. Control panel should be washed with a clean, damp, non-
abrasive cloth and chlorine-free detergent. Rinse thoroughly
with clean damp cloth and allow to dry. Do not use abrasive
cleaners, waxes, car polish, or substances containing strong
aromatic solvents or alcohol. If the control knob(s) need to be
removed for cleaning, simply pull the knob out, clean the con-
trol panel and knob, and then replace the knob.
CAUTION:
ELECTRIC SHOCK
HAZARD
Disconnect appliance from
electric power before cleaning.
CAUTION:
HOT SURFACE
Exposed surfaces can
be hot to the touch and may
cause burns. Allow appliance
to cool before cleaning.
IMPORTANT:
DO NOT spill or pour
water into controls,
control panel or wiring.
Water damage is not covered
by warranty.
CAUTION
:
Beware of sharp
edges with sheet
metal during cleaning process.
CAUTION:
Do not use strong detergents, alkalis, ammonia solutions or
abrasive cleaners. Use only cleaning agents approved for alu-
minum and only in the recommended manufacturer’s concentration. Do
not use steel wool pads—ferrous deposits will cause rusting.
Use of cleaning agents that are not recommended for aluminum may
cause permanent damage to the cabinet. THIS DAMAGE IS PERMA-
NENT, COSTLY TO REPAIR AND IS NOT COVERED BY THE
WARRANTY.
14
CABINET MAINTENANCE
CASTERS
Some cabinets may have caster bearings that are equipped with
Zerk grease fittings so that they may be easily lubricated with a
grease gun. Lubricate bearings at least once every six months.
HINGE MAINTENANCE
Make sure all joints remain sealed and door latches do not stick. If
necessary, use WD-40 to keep door latches from sticking. Do not
use oil.
REVERSING THE DOOR
Reversing the door takes about 30 minutes & requires two people.
1. Using a small screwdriver, pry off the hinge covers and set
aside. Removing the covers will allow access to the inside
hinge screws. Remove the three screws that hold each hinge
to the cabinet. DO NOT REMOVE THE SCREWS THAT
HOLD THE HINGES TO THE DOOR. Remove the door, tak-
ing care not to let it fall.
2. Remove the door strike plate and screws adjacent to the door
opening on the cabinet. Reinstall door strike plate and screws
on opposite side of the cabinet.
3. Screw hinges onto opposite side of the door.
4. With the help of another person, hold door up to the cabinet
and attach with the screws removed in step one. Before tight-
ening the screws, be sure the door is flush, level and square.
Replace the hinge covers.
WARNING:
DO NOT perform
these procedures
while the cabinet is turned on
or heated. Turn off the power
and wait for the cabinet to cool
to room temperature.
CAUTION:
Do not move cabinet
unless door is se-
curely closed. Serious dam-
age to hinges and door may
result if bumped into tables,
walls, or other equipment when
the doors are open.
Logix1 & Logix3 HB SERIES
120 VOLT, 1800 WATT, 15AMP, 1 PH, 60 HZ
Logix2 & Logix4 HW SERIES
120 VOLT, 2100 WATT, 17.5 AMP, 1 PH
WIRING DIAGRAMS
15
REPLACEMENT PARTS
Use only (OEM) original equipment manufacturer replacement parts. Using unauthorized parts may
cause serious injury or damage to the cabinet. Replacement parts should be installed by a qualified
service technician.
Contact Carter-Hoffmann with your model and serial number for replacement parts.
Call: 800-323-9793 or
Part Number HB LOGIX1 & LOGIX3 Series Description
18600-0046 Hi limit—open at 300°F, close at 250°F
18602-0083 On/Off switch 20 Amp
18602-0031 Switch boot
18608-0010 Knob—heat
18605-0022 Power cord-8
18606-0221 5-20P plug
18612-0131 Heat element 1700 watt
18616-0071 Transformer
18614-0360 Fan motor
18614-0321 Fan motor blower wheel
18314-0019 1.8 qt. black condensation pan
18600-0017 Thermostat
18614-0322 Muffin fan
18616-0073 Digital thermometer
18616-0071 Transformer for digital thermometer
18601-1171 Red indicator light, power and heat
Part Number HW LOGIX2 & LOGIX4 Series Description
18600-0046 Hi limit—open at 300°F, close at 250°F
18602-0083 On/Off switch 20 Amp
18602-0031 Switch boot
18608-0010 Knob—heat or humidity
18605-0022 Power cord—8’
18606-0221 5-20P plug
18612-0131 Heat element 1700 watt
18612-0132 Water pan element 350 watt
18616-0071 Transformer
18614-0322 Muffin fan
18614-0360 Fan motor
18614-0321 Fan motor blower wheel
18314-0019 1.8 qt. black condensation pan
18600-0017 Thermostat—heat element
18600-0016 Thermostat—humidity element
18616-0073 Digital thermometer
18616-0071 Transformer for digital thermometer
18601-1171 Red indicator light, power, heat & humidity
16
17
TROUBLESHOOTING GUIDE
SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY
No power on display Not plugged in or circuit breaker
tripped
Check or reset circuit breaker
Connect to proper receptacle
Power cord damaged Check - replace if required
Circuit breaker tripped Check circuit breaker
Power switch damaged or defective Check - replace if required
Food dries out too
quickly
Operation where product temp is too
high; food pans should be covered
Check product temps going into
holding cabinet; cover food pans
Control incorrectly set or defective Check proper operation or calibration
of control
Internal wiring error
Call service technician
Element hi-limit trip / defective Call service technician
Takes too long to
get to temperature
Improper voltage Call service technician to verify
incoming voltage matches cabinet
specifications.
Unit is hot
but low or no airflow
Internal wiring error Call service technician
Circulation motor has quit Call service technician
Improper voltage Call service technician to verify
incoming voltage matches cabinet
specifications.
Unit is on, motors
are running but no
heat
NOTE:
The technical content of this manual,
including any wiring diagrams, schemat-
ics, parts breakdown illustrations and /
or adjustment procedures, is intended
for use ONLY by qualified technical
personnel
.
NOTE:
For warranty service, call Carter-Hoffmann
direct at 800-323-9793 for authorization,
we will dispatch the nearest authorized
service agency.
18
Carter-Hoffmann Warranty:
Carter-Hoffmann (“CARTER-HOFFMANN”) warrants to the initial purchaser of its standard Carter
Line Products that CARTER-HOFFMANN will, at its option, repair or replace, during the warranty
period set forth below, any part of such products made necessary due to a defect in material or work-
manship which is present when the product leaves its factory and which manifests itself during the war-
ranty period under normal use and service.
This warranty applies only to original equipment owned and possessed by the initial purchaser and the
warranty period begins on the date of original shipment from the CARTER-HOFFMANN factory and
extends as follows: to component parts and labor for 12 months (36 months on hotLOGIX holding
cabinets and cook & hold cabinets); to refrigeration compressor unit for one year (limited to replace-
ment only - not to include labor for removal, repair or replacement).
Repair or replacements under this warranty will be performed, unless otherwise authorized in writing
by CARTER-HOFFMANN, at its factory. All parts or components to be repaired or replaced under this
warranty are to be shipped prepaid to CARTER-HOFFMANN, with reimbursement credit for such part
or component to be given if found by CARTER-HOFFMANN to be defective.
CARTER-HOFFMANN neither makes nor assumes and does not authorize any other person to make or
assume any obligation or liability in connection with its products other than that covered in this war-
ranty. This warranty applies only within the continental United States and Canada. In Alaska and Ha-
waii, this warranty applies only to and is limited to the supply of replacement parts.
Warranty Exclusions and Limitations:
Any implied warranty of merchantability or fitness for a particular purpose is hereby specifically dis-
claimed by CARTER-HOFFMANN. There are no warranties, expressed or implied, which extend be-
yond the description on the face hereof. This warranty does not cover and CARTER-HOFFMANN shall
not under any circumstances be liable for any incidental, consequential or other damages (such as in-
jury to persons or property, loss of time, inconvenience, loss of business or profits, or other matters not
specifically covered) arising in connection with the use of, inability to use, or failure of these products.
Specifications subject to change through product improvement and innovation.
3-YEAR WARRANTY on HOTLOGIX HOLDING CABINETS
Carter-Hoffmann
1551 McCormick Ave.
Mundelein, Illinois, 60060 USA
Phone: 847-362-5500 Toll free: 800-323-9793 Fax: 847-367-8981
Sales and Marketing E-mail: sales@carter-hoffmann.com
Service E-mail: [email protected]
Company Website: www.carter-hoffmann.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

CARTER-HOFFMANN HBU5A2GM Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI