Supermicro SUPERSERVER 6014P-32R User manual

Category
Server barebones
Type
User manual

This manual is also suitable for

®
SUPERSERVER 6014P-32
SUPERSERVER 6014P-32R
USER’S MANUAL
1.0
SUPER
The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
makes no commitment to update or to keep current the information in this manual, or to notify any
person or organization of the updates.
Please Note: For the most up-to-date version of
this manual, please see our web site at www.supermicro.com.
SUPERMICRO COMPUTER reserves the right to make changes to the product described in this
manual at any time and without notice. This product, including software, if any, and documenta-
tion may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any
medium or machine without prior written consent.
IN NO EVENT WILL SUPERMICRO COMPUTER BE LIABLE FOR DIRECT, INDIRECT, SPECIAL,
INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE
OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, THE VENDOR SHALL NOT HAVE
LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE
PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING
OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa
Clara County in the State of California, USA. The State of California, County of Santa Clara shall
be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all
claims will not exceed the price paid for the hardware product.
Manual Revision 1.0
Release Date: November 22, 2005
Unless you request and receive written permission from SUPER MICRO COMPUTER, you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
Copyright © 2005 by SUPER MICRO COMPUTER INC.
All rights reserved.
Printed in the United States of America
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It
provides information for the installation and use of the SuperServer 6014P-32 and
6014P-32R. Installation and maintainance should be performed by experienced
technicians only.
The SuperServer 6014P-32/6014P-32R is a high-end 1U rackmount server based
on the SC816A-700/SC816A-R700 1U rackmount server chassis and the X6DHP-
3G2 serverboard, which supports single or dual Intel® Xeon processors of up
to 3.60 GHz at a Front Side (system) Bus speed of 800 MHz and up to 16 GB of
DDR2-400 SDRAM memory.
Manual Organization
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with
the server system and describes the main features of the SUPER X6DHP-3G2
serverboard and the SC816A-700/SC816A-R700 chassis, which make up the
SuperServer 6014P-32/6014P-32R.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer 6014P-
32/6014P-32R into a rack and check out the server confi guration prior to powering
up the system. If your server was ordered without processor and memory com-
ponents, this chapter will refer you to the appropriate sections of the manual for
their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and
information provided by the control panel on the chassis as well as other LEDs
located throughout the system.
iii
Preface
SUPERSERVER 6014P-32/6014P-32R User's Manual
iv
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview
of safety precautions that should be followed when installing and servicing the
SuperServer 6014P-32/6014P-32R.
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X6DHP-3G2 serverboard, includ-
ing the locations and functions of connectors, headers and jumpers. Refer to this
chapter when adding or removing processors or main memory and when reconfi g-
uring the serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the 1U SC816A-700/SC816A-R700
rackmount server chassis. You should follow the procedures given in this chapter
when installing, removing or reconfi guring SAS/SATA or peripheral drives and when
replacing the system power supply unit and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed informa-
tion on running the CMOS Setup Utility.
Appendix A: BIOS POST Codes
Appendix B: Software Installation
Appendix C: System Specifi cations
v
Preface
Notes
SUPERSERVER 6014P-32/6014P-32R User's Manual
vi
Table of Contents
Preface
About This Manual ...................................................................................................... iii
Manual Organization ................................................................................................... iii
Chapter 1: Introduction
1-1 Overview ......................................................................................................... 1-1
1-2 Serverboard Features ..................................................................................... 1-2
1-3 Server Chassis Features ................................................................................ 1-4
1-4 Contacting Supermicro ................................................................................... 1-6
Chapter 2: Server Installation
2-1 Overview ......................................................................................................... 2-1
2-2 Unpacking the System ................................................................................... 2-1
2-3 Preparing for Setup ........................................................................................ 2-1
Choosing a Setup Location .................................................................... 2-2
Rack Precautions .................................................................................... 2-2
Server Precautions ................................................................................. 2-2
Rack Mounting Considerations ............................................................... 2-3
2-4 Installing the System into a Rack ................................................................... 2-4
Identifying the Sections of the Rails ....................................................... 2-4
Installing the Inner Rails ............................................................................ 2-4
Installing the Outer Rails ........................................................................... 2-5
Installing the Server into the Rack ............................................................ 2-6
Installing the Server into a Telco Rack ..................................................... 2-7
2-5 Checking the Serverboard Setup ................................................................... 2-8
2-6 Checking the Drive Bay Setup ..................................................................... 2-10
Chapter 3: System Interface
3-1 Overview ......................................................................................................... 3-1
3-2 Control Panel Buttons .................................................................................... 3-1
UID .......................................................................................................... 3-1
Power ...................................................................................................... 3-1
3-3 Control Panel LEDs ........................................................................................ 3-2
UID ............................................................................................................ 3-2
Overheat/Fan Fail .................................................................................. 3-2
NIC2 .......................................................................................................... 3-2
NIC1 .......................................................................................................... 3-2
HDD ........................................................................................................ 3-3
Power ...................................................................................................... 3-3
3-4 SAS/SATA Drive Carrier LEDs ........................................................................ 3-3
Chapter 4: System Safety
4-1 Electrical Safety Precautions ........................................................................... 4-1
4-2 General Safety Precautions ............................................................................. 4-2
4-3 ESD Precautions ............................................................................................ 4-3
4-4 Operating Precautions ..................................................................................... 4-4
Chapter 5: Advanced Serverboard Setup
5-1 Handling the Serverboard ................................................................................ 5-1
5-2 Processor and Heatsink Installation ................................................................ 5-2
5-3 Connecting Cables .......................................................................................... 5-4
Connecting Data Cables ........................................................................... 5-4
Connecting Power Cables ......................................................................... 5-4
Connecting the Control Panel ................................................................... 5-5
5-4 I/O Ports ........................................................................................................... 5-6
5-5 Installing Memory ............................................................................................. 5-6
5-6 Adding PCI Cards ............................................................................................ 5-8
5-7 Serverboard Details ......................................................................................... 5-9
X6DHP-3G2 Layout ................................................................................ 5-9
X6DHP-3G2 Quick Reference .............................................................. 5-10
5-8 Connector Defi nitions .................................................................................... 5-11
ATX Power Connection ......................................................................... 5-11
Secondary Power Connection .............................................................. 5-11
Processor Power Connector ................................................................. 5-11
NMI Button ............................................................................................ 5-11
Power LED ............................................................................................ 5-12
HDD LED ................................................................................................. 5-12
NIC1 LED .............................................................................................. 5-12
NIC2 LED .............................................................................................. 5-12
Overheat/Fan Fail LED ........................................................................... 5-12
Power Fail LED ....................................................................................... 5-13
UID Button/LED ...................................................................................... 5-13
Power Button ........................................................................................... 5-13
Universal Serial Bus ................................................................................ 5-13
Extra Universal Serial Bus Headers ....................................................... 5-14
Chassis Intrusion ..................................................................................... 5-14
Fan Headers .......................................................................................... 5-14
vii
Table of Contents
SUPERSERVER 6014P-32/6014P-32R User's Manual
viii
Serial Ports .............................................................................................. 5-14
Power LED/Speaker ................................................................................ 5-15
ATX PS/2 Keyboard & Mouse Ports ....................................................... 5-15
JLAN 1/2 (Ethernet Ports) ........................................................................ 5-15
Wake-On-Ring ......................................................................................... 5-15
SMB ......................................................................................................... 5-16
SMB Power ............................................................................................. 5-16
SAS Activity LED Header ........................................................................ 5-16
5-9 Jumper Settings ............................................................................................. 5-17
Explanation of Jumpers ........................................................................... 5-17
CMOS Clear ............................................................................................ 5-17
VGA Enable/Disable ................................................................................ 5-17
JLAN Enable/Disable .............................................................................. 5-18
SAS Controller Enable/Disable ............................................................... 5-18
Watch Dog Enable/Disable ..................................................................... 5-18
5-10 Onboard Indicators ........................................................................................ 5-19
JLAN1/JLAN2 LEDs ................................................................................ 5-19
SAS Activity LED Indicators ................................................................... 5-19
Unit Identifi er Indicators ......................................................................... 5-19
5-11 SATA, Floppy and Hard Drive Connections .................................................. 5-20
Floppy Connector .................................................................................... 5-20
IDE Connectors ....................................................................................... 5-21
SATA Connectors ................................................................................... 5-21
Chapter 6: Advanced Chassis Setup
6-1 Static-Sensitive Devices .................................................................................. 6-1
6-2 Control Panel ................................................................................................... 6-2
6-3 System Fans .................................................................................................... 6-3
System Fan Failure ................................................................................... 6-3
Replacing System Cooling Fans ............................................................... 6-3
6-4 Drive Bay Installation/Removal ........................................................................ 6-4
Accessing the Drive Bays ......................................................................... 6-4
SAS/SATA Drive Installation ...................................................................... 6-5
DVD/CD-ROM and Floppy Drive Installation ............................................ 6-7
6-5 Power Supply ................................................................................................... 6-8
6014P-32R: Power Supply Failure ............................................................ 6-8
6014P-32R: Removing/Replacing the Power Supply ............................... 6-8
6014P-32: Power Supply Failure .............................................................. 6-9
6014P-32: Removing/Replacing the Power Supply .................................. 6-9
Table of Contents
ix
Chapter 7: BIOS
7-1 Introduction ....................................................................................................... 7-1
7-2 Running Setup .................................................................................................. 7-2
7-3 Main BIOS Setup ............................................................................................. 7-2
Main BIOS Setup Menu ............................................................................. 7-3
7-4 Advanced Setup .............................................................................................. 7-6
7-5 Security .......................................................................................................... 7-16
7-6 Boot ............................................................................................................... 7-18
7-7 Exit ................................................................................................................. 7-19
Appendices:
Appendix A: BIOS POST Codes ............................................................................... A-1
Appendix B: Software Installation ............................................................................. B-1
Appendix C: System Specifi cations ......................................................................... C-1
SUPERSERVER 6014P-32/6014P-32R User's Manual
x
Notes
Chapter 1: Introduction
1-1
Chapter 1
Introduction
1-1 Overview
The SuperServer 6014P-32/6014P-32R is a high-end dual processor, 1U rackmount
server is comprised of two main subsystems: the SC816A-700/SC816A-R700 1U
rackmount chassis and the X6DHP-3G2 Xeon dual processor serverboard. Please
refer to our web site for information on operating systems that have been certifi ed
for use with the 6014P-32/6014P-32R (www.supermicro.com).
In addition to the mainboard and chassis, various hardware components may have
been included with your 6014P-32/6014P-32R, as listed below:
One (1) slim fl oppy drive [FPD-TEAC-S(B)]
One (1) slim DVD-ROM drive [DVM-PNSC-824(B)]
Two (2) PCI-X riser cards installed (CSE-RR1U-X and CSE-RR1U-XR)
Two (2) PCI-E riser cards (CSE-RR1U-EL and CSE-RR1U-ER, in accessory
box)
Five (5) 4-cm counter-rotating cooling fans (FAN-0085)
SAS (Serial Attached SCSI) and Serial ATA (SATA) Accessories:
One (1) SAS/SATA backplane (CSE-SAS-816A)
One (1) SAS/SATA data cable (CBL-0108)
Four (4) SAS/SATA drive carriers [CSE-PT39(B)]
Rackmount hardware with screws (CSE-PT51):
Two (2) rack rail assemblies
Six (6) brackets for mounting the rack rails to a rack/telco rack
One (1) CD containing drivers and utilities
Optional: Two (2) passive 1U CPU heatsinks (SNK-P0009)
SuperServer 6014P-32/6014P-32R User's Manual
Note: a "B" at the end of a part number indicates the item is available in black.
SUPERSERVER 6014P-32/6014P-32R User's Manual
1-2
1-2 Serverboard Features
At the heart of the SuperServer 6014P-32/6014P-32R lies the X6DHP-3G2 a dual
Xeon processor serverboard designed to provide maximum performance. Below
are the main features of the X6DHP-3G2. See Figure 1-1 for a system block
diagram of the chipset.
Processors
The X6DHP-3G2 supports single or dual 604-pin Intel Xeon processors of up to
3.60 GHz at an 800 MHz FSB. Please refer to our web site for a complete listing
of supported processors.
Memory
The X6DHP-3G2 has eight 240-pin DIMM slots that can support up to 16 GB of
DDR2-400 SDRAM. The dual-channel memory bus requires memory modules
to be installed two at a time.
Serial Attached SCSI/Serial ATA
An Adaptec 9410W SAS/SATA controller is integrated into the X6DHP-3G2 to
provide a Serial Attached SCSI/Serial ATA subsystem that includes four internal
and four external SAS ports. RAID levels 0, 1 and JBOD are supported. The
X6DHP-3G2 also has a slot for a LP ZCR card (AOC-LPZCR1) to supply ZCR
function. The use of a ZCR card in this slot will also provide RAID 5 support.
Note: The operating system you use must have RAID support to enable the hot-
swap capability and RAID function of the SAS/SATA drives.
PCI Expansion Slots
Two riser cards have been preinstalled in the server to support PCI expansion.
The CSE-RR1U-XR riser fi ts into the 100 MHz PCI-X slot #2 to support a standard
size (full-height, full-length) PCI-X add-on card (of either 100 or 66 MHz). The
CSE-RR1U-X ts into the 100 MHz PCI-X slot #1 to support one low profi le (half-
height, half-length) PCI-X add-on card (of either 100 or 66 MHz).
An additional two riser cards are included in the retail box as an option to support
x8 PCI-E add-on cards: the CSE-RR1U-EL and CSE-RR1U-ER.
Chapter 1: Introduction
1-3
ATI Graphics Controller
An ATI video controller based on the Rage XL 8 MB graphics chip is integrated
onboard the X6DHP-3G2.
Onboard Controllers/Ports
The X6DHP-3G2 provides one fl oppy drive controller and two onboard IDE control-
lers, which support up to four hard drives or ATAPI devices. Backpanel I/O ports
include one COM port, two USB ports, PS/2 mouse and keyboard ports, a UID
button and a video (monitor) port. An Intel 82546GB Ethernet controller is also
included to support two gigabit LAN ports.
Other Features
Other onboard features are included to promote system health. These include
various voltage monitors, two CPU temperature sensors, four fan speed sensors,
a chassis intrusion header, auto-switching voltage regulators, chassis and CPU
overheat sensors, virus protection and BIOS rescue.
SUPERSERVER 6014P-32/6014P-32R User's Manual
1-4
1-3 Server Chassis Features
The SuperServer 6014P-32/6014P-32R is built upon Supermicro's SC816A-700/
SC816A-R700 1U chassis and features four hot-swap SAS/SATA drive bays, a slim
DVD-ROM drive, a slim 3.5" fl oppy drive and a revolutionary cooling design that
can keep today's most powerful processors running well below their temperature
thresholds. The following is a general outline of the main features of the SC816A-
700/SC816A-R700 chassis.
System Power
The SC816A-700 chassis includes a single 700W cold-swap power supply. The
SC816A-R700 chassis features a redundant 700W hot-swap power supply. These
power supplies have I
2
C built-in.
SAS/SATA Subsystem
For the 6014P-32/6014P-32R, the SC816A-700/SC816A-R700 chassis was de-
signed to support four SAS or four SATA hard drives, which are hot-swappable
units.
Note: The operating system you use must have RAID support to enable the hot-
swap capability of the SAS/SATA drives.
Control Panel
The SC816A-700/SC816A-R700 control panel provides you with system monitoring
and control. LEDs indicate UID, system power, HDD activity, network activity (2) and
overheat/fan failure. A main power button and a UID button are also included.
I/O Backplane
Ports on the I/O backplane include one COM port, a VGA port, two USB ports, PS/2
mouse and keyboard ports, two gigabit Ethernet ports and a UID button/LED.
Chapter 1: Introduction
1-5
Figure 1-1. Intel E7520 Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
MCH
VRM
4_DDR266/333
ADDR
CTRL
DATA
EM64T NOCONA CPU#1
ADDR
CTRL
DATA
DATA
ADDR
CTRL
DIMMs
ICH5R
FWHLPC I/O
LPC BUS
HUB
BMC CON.
PCI BUS(32-BIT)
DIMMs
4_DDR266/333
USB
0,1,2,3
USB PORTS
VGA
KB.
SER.2
SER.1
H/W
MONITOR
FDD.
MS.
VRM
0, 1
SATA
SATA
UDMA-100
IDE
PRI/SEC
PCI EXP. B(X8)
SATA
Gbit LAN
ANVIK
SOCKET
ZCR
PXH#2
A
B
PCI EXP. A(X8)
SLOT--6
PCI-X BUS(100MHZ)
1_PCI-X133
PCI-X BUS(133MHZ)
1_PCI-X100
SLOT--7
266MB/s
4GB/s
6.4GB/s
6.4GB/s
PCI EXP. C(X8)
PCI EXP. B(X8)
PCI-E_(X8)
PCI-E_(X8)
B
C
A
A
B
Clock
4 Ports
EM64T NOCONA CPU#1
Cooling System
The SC816A-700/SC816A-R700 chassis has an innovative cooling design that
features fi ve sets of 40-mm counter-rotating fans located in the middle section of
the chassis. There is a "Fan Speed Control Mode" setting in BIOS (see Chapter
7) that allows chassis fan speed to be determined by system temperature [recom-
mended setting is "3-pin (Server)]. The power supply module(s) also includes a
cooling fan.
SUPERSERVER 6014P-32/6014P-32R User's Manual
1-6
1-4 Contacting Supermicro
Headquarters
Address: SuperMicro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: [email protected] (General Information)
[email protected] (Technical Support)
Web Site: www.supermicro.com
Europe
Address: SuperMicro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: [email protected] (General Information)
[email protected] (Technical Support)
[email protected] (Customer Support)
Asia-Pacifi c
Address: SuperMicro, Taiwan
4F, No. 232-1, Liancheng Rd.
Chung-Ho 235, Taipei, Taiwan, R.O.C.
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3991
Web Site: www.supermicro.com.tw
Technical Support:
Tel: 886-2-8228-1366, ext.132 or 139
Chapter 2: Server Installation
2-1
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 6014P-
32/6014P-32R up and running. Following these steps in the order given should
enable you to have the system operational within a minimum amount of time.
This quick setup assumes that your system has come to you with the processors
and memory preinstalled. If your system is not already fully integrated with a
serverboard, processors, system memory etc., please turn to the chapter or section
noted in each step for details on installing specifi c components.
2-2 Unpacking the System
You should inspect the box the SuperServer 6014P-32/6014P-32R was shipped
in and note if it was damaged in any way. If the server itself shows damage you
should fi le a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the 6014P-32/6014P-
32R. It should be situated in a clean, dust-free area that is well ventilated. Avoid
areas where heat, electrical noise and electromagnetic fi elds are generated. You
will also need it placed near a grounded power outlet. Be sure to read the Rack
and Server Precautions in the next section.
2-3 Preparing for Setup
The box the SuperServer 6014P-32/6014P-32R was shipped in should include two
sets of rail assemblies, two rail mounting brackets and the mounting screws you
will need to install the system into the rack. Follow the steps in the order given to
complete the installation process in a minimum amount of time. Please read this
section in its entirety before you begin the installation procedure outlined in the
sections that follow.
2-2
S
UPERSERVER 6014P-32/6014P-32R User's Manual
Choosing a Setup Location
- Leave enough clearance in front of the rack to enable you to open the front
door completely (~25 inches).
- Leave approximately 30 inches of clearance in the back of the rack to allow
for suffi cient airfl ow and ease in servicing.
- This product is for installation only in a Restricted Access Location (dedicated
equipment rooms, service closets and the like).
Rack Precautions
- Ensure that the leveling jacks on the bottom of the rack are fully extended to
the fl oor with the full weight of the rack resting on them.
- In single rack installation, stabilizers should be attached to the rack.
- In multiple rack installations, the racks should be coupled together.
- Always make sure the rack is stable before extending a component from the
rack.
- You should extend only one component at a time - extending two or more
simultaneously may cause the rack to become unstable.
Server Precautions
- Review the electrical and general safety precautions in Chapter 4.
- Determine the placement of each component in the rack before you install the
rails.
- Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
- Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a
power failure.
-
Allow the hot plug SCSI/SATA drives and power supply modules to cool before
touching them.
-
Always keep the rack's front door and all panels and components on the serv-
ers closed when not servicing to maintain proper cooling.
!
!
Warnings and Precautions!
Chapter 2: Server Installation
2-3
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera-
ture of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient tempera-
ture (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connec-
tions other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).
2-4
S
UPERSERVER 6014P-32/6014P-32R User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the 6014P-32/6014P-32R into a
rack unit with the rack rails provided. If the system has already been mounted into
a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack
units on the market, which may mean the assembly procedure will differ slightly.
You should also refer to the installation instructions that came with the rack unit
you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies in the rack mounting kit. Each
assembly consists of two sections: an inner fi xed chassis rail that secures directly
to the server chassis and an outer fi xed rack rail that secures directly to the rack
itself (see Figure 2-1). Two pairs of short brackets to be used on the front side of
the outer rails are also included.
Installing the Inner Rails
Both the left and right side inner rails have been pre-attached to the chassis.
Proceed to the next step. A
Figure 2-1. Identifying the Sections of the Rack Rails
(right side rail shown)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126

Supermicro SUPERSERVER 6014P-32R User manual

Category
Server barebones
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI