Modern Forms FH-W2202 Skylark Flush, FH-W2202-54L-BN/EB, FH-W2202-54L-MB, FH-W2202-54L-SB/MB, FR-W2202-54L-BN/EB, FR-W2202-54L-MB, FR-W2202-54L-SB/MB Operating instructions

  • Hello! I've reviewed the installation instructions for the Modern Forms Skylark Flush household fan. This document covers everything from mounting and wiring to controlling the fan via the included remote, optional wall control, or the Modern Forms app. I'm ready to answer any questions you have about the installation process or the smart features of your new fan.
  • What is the minimum clearance required for the fan blades?
    What should I do before cleaning the fan?
    What is Breeze Mode?
Skylark Flush
Installation Instructions
works with the
Google Assistant
FH-W2202-54L
Skylark Flush Instructions
2
Please read and
save these instructions
before installation
DO NOT RETURN TO STORE
FH-W2202-54L Skylark Flush Instructions
3
For all questions about your ceiling fan please read all included
instructions, installation procedures, troubleshooting guidelines
and warranty information before starting installation.
For missing parts or general inquiries call our trained technical staff at:
1-866-810-6615 option 1
MON-FRI 8AM-8PM EST
Email: customerservice@modernforms.com
Or live chat at modernforms.com
For fast service have the following information below when you call:
1. Model Name and Number
2. Part Number and Part Description
3. Date Of Purchase and Purchase Location
1-866-810-6615 option 2
MON-FRI 8AM-8PM EST
Email: fansupport@modernforms.com
General Inquiries
Fan Support
FH-W2202-54L
Skylark Flush Instructions
4
For operation, maintenance, and troubleshooting information,
visit http://modernforms.com/fan-support/
To reduce the risk of electric shock, ensure electricity has been turned off at the circuit breaker
before beginning. All wiring must be in accordance with the National Electrical Code ANSI/NFPA
70” and local electrical codes. Electrical installation should be performed by a licensed electrician.
The fan must be mounted with a minimum of 7 ft. (2.1m) clearance from the trailing edge of
the fan blades to the floor and a minimum of 1.5 ft (0.5m) from the edge of the fan blades to the
surrounding walls. Never place objects in the path of the fan blades. To avoid personal injury or
damage to the fan and other items, please be cautious when working around or cleaning the fan.
To avoid electrical shock or damage to the motor or finish, do not use water or chemicals
when cleaning the fan or fan blades. A dry cloth or lightly dampened cloth will be suitable
for most cleaning.
After making electrical connections, spliced conductors should be turned upward and pushed
carefully up into the outlet box. The wires should be spread apart with the grounded conductor and
the equipment-grounding conductor on one side of the outlet box, and the ungrounded conductor
on the other side of the outlet box.
All set screws must be checked and re-tightened
where necessary before installation.
Safety Rules
FH-W2202-54L Skylark Flush Instructions
5
WARNING: Do not install or use your fan if any part(s) is/are damaged or missing. This product
is designed for use only with the supplied parts and/or accessories designated for use with this
product by Modern Forms. Substitution of parts or accessories not designated for use with this
product by Modern Forms could result in personal injury or property damage and will void the
warranty. Contact an authorized dealer or the manufacturer if any parts are damaged or missing.
WARNING: To reduce the risk of electric shock, this fan must
be installed and operated with the supplied wall control, or controlled from the Modern Forms app.
WARNING: Do not use power tools to assemble or install your fan. Using power tools can result in
improper assembly which can lead to noise or fan damage,personal injury or property damage.
WARNING: To reduce the risk of personal injury, do not bend the blade arms when installing the
brackets, balancing the blades or cleaning the fan.
WARNING: Do not insert foreign objects between rotating fan blades.
WARNING: Do not operate fan unless fan blades are in place. Noise and fan damage can occur
WARNING: This appliance is not intended for use by young children without supervision.
WARNING: To reduce the risk of fire, electric shock, personal injury or damage to the fan or other
items, the outlet box and support structure must be securely mounted and capable of reliably
supporting a minimum of 35 Ibs (15.9 kg). Use only UL/cUL listed outlet boxes marked “FOR FAN
SUPPORT. Use only the screws and washers provided with the outlet box.
CAUTION: Before assembling your fan, refer to the “Making the Electrical Connections“
section. If you feel you do not have enough wiring knowledge or experience, have your fan
installed by a licensed electrician.
NOTE: Before servicing or cleaning the fan, switch power off at the circuit breaker.
FH-W2202-54L
Skylark Flush Instructions
6
Get Smart...
Integrates
seamlessly with:
devices you already own
works with the
Google Assistant
Premium smart
features:
Accessories:
DC
MOTOR
complement high quality materials
personalize your experience
Quiet, reliable, and up to 70%
more ecient than AC fans
Wi-Fi and Bluetooth enabled
for exible control
Bluetooth Wall Control
Dims light to 1% | ON/OFF
6 fan speeds | Sold separately
F-WCBT-WT White
Bluetooth Remote Control
Dims light to 1% | ON/OFF
6 fan speeds
F-RCBT-WT White
Wet Location-listed to the strictest
UL/cUL safety regulations. Finished
and rated for interior and exterior use
FH-W2202-54LSkylark Flush Instructions 7
Contents
Tools Required
1. Mounting Options 10
2. Installing the Mounting Bracket 12
3. Attaching the Fan Blade 12
4. Adding the Decorative Trim Ring 12
5. Hanging the Fan 14
6. Making the Electrical Connections 16
7. Installing the Optional Wall Control 18
8. Finishing the Installation 20
9. Installing Adapter Plate 20
10. Installing the Luminaire Module 22
11. Controlling the Fan 24
11. Reset 26
12. Breeze Mode 26
13. Application 26
14. Accessories 28
14. Troubleshooting 29-32
FH-W2202-54L
Skylark Flush Instructions8
Package Contents
6. LED Module
F4IN-120V-R1-30
7. PC Shade
RPL-F2202-GLA
8. Receiver
F-R3-2202-054H
9. Remote Control
F-RCBT-WT
Hardware Bag
RPL-F2202-PARTS
1. Fan Blades
RPL-F2202-54-BD-**
2. Mounting Bracket
RPL-F2202-HANGER
3. Decorative Trim Ring
RPL-F2202-TRIM-**
RPL-F2202-ADP-**
4. Motor Housing
5. Adapter Plate
** denotes finish code of fan /blade sweep of fan
Before discarding packaging materials be certain all parts have been removed.
Place the parts from the hardware bag into a small container to keep them from being lost.
A: Junction Box
#10x38mm Pan Head Phillip Screws (2)
Ø5*14*1mm Flat Washer (2)
3/16" Star Washer (2)
B: Blade
1/4”x16mm+S Pan Head Phillip Screws (7)
1/4” Flat Washer (7)
Part A
Part B
Part C
Part D
Hardware Bag
Found with the receiver
C: Safety Cable
Φ6.5x19x2mm Flat Washer (1pc)
3/16”(Φ5.2x8.4x1.0mm) Spring Washer (1)
#10x76mm Pan Head Phillip Wood Screws (1)
D: Wire Connectors (8)
FH-W2202-54LSkylark Flush Instructions 9
1 Decorative Trim Ring comes pre-attached to the Motor Housing
MAC ID
9
3
6
7
8
4
5
2
Hanging Weight: 17 lbs
IMPORTANT: Please make note of
the MAC ID on the receiver and
keep it in a safe place.
1
1
FH-W2202-54L
Skylark Flush Instructions
10
1. Mounting Options
CAUTION: To prevent electrical shock, ensure electricity has been
turned off at the circuit breaker before beginning.
If there isn’t an existing UL/cUL listed outlet box, please refer to the
following instructions. Secure the outlet box directly to the building
structure. Use appropriate fasteners and building materials. The
outlet box and support structure must be able to fully support the
moving weight of the fan (at least 35 lbs/15.9 kg). Do not use plastic
outlet boxes. Use only UL/cUL listed outlet boxes marked
“FOR FAN SUPPORT.
Secure the outlet box directly to the building structure.
Use Part A if needed to mount the outlet box.
Figures 1-1B are examples of different ways to mount the
outlet box.
NOTE: To hang your fan where there is an existing fixture but no
ceiling joist, you may need an installation hanger bar.
FH-W2202-54L Skylark Flush Instructions
11
1
1A
1B
2
1
2
2
3
1. Support Brace
2. Outlet Box
3. Joist
FH-W2202-54L
Skylark Flush Instructions12
2. Installing the Mounting Bracket
Remember to disconnect the power at the circuit breaker.
1. Attach the mounting bracket to the outlet box with the screws
provided with your outlet box. (Fig.2)
2. Pass supply wires through mounting bracket and
secure to outlet box.
1. Place blades on the motor housing and align the blade holes
with the holes on the motor housing. Secure blades with blade
attachment screws and washers. Use Part B.
3. Attaching the Fan Blade
NOTE: You may want to place the fan on the included styrofoam in the
package for easier assembly.
FH-W2202-54L Skylark Flush Instructions
13
2 3
FH-W2202-54L
Skylark Flush Instructions
14
1. Lift motor assemby and hang it on the hook on the mounting
plate using one of the screw holes.
2. Secure the safety cable into the structure beams using the wood
screw, washers, and spring washers provided. Use Part C.
NOTE: Safety cable is required for all installations in Canada. Safety
cable is required for ceiling fan and light combinations over 35 lbs. in
both flush and downrod models in the United States (Fig. 5).
5. Hanging the Fan
FH-W2202-54L Skylark Flush Instructions
15
5
FH-W2202-54L
Skylark Flush Instructions
16
6. Making the Electrical Connections
WARNING: Installation of this fan requires that a three-conductor
cable (including ground wire) which should run between ceiling and
wall outlet box. Use Part D.
WARNING: Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire nuts,
except for the ground wire.
Insert the receiver into the mounting bracket with the flat side of the
receiver facing the ceiling (Fig. 6).
Motor to Receiver & Receiver to house supply wires (Fig. 6A).
1. Connect the fan assembly ground wire, mounting bracket
ground wire, and receiver ground wire to the ground wire in
the outlet box.
WARNING: Failure to connect ground wires could result in
poor fan control functionality.
2. Connect the red wire from the fan to the red wire marked
TO MOTOR from the receiver.
3. Connect the grey wire from the fan to the grey wire marked
TO MOTOR from the receiver.
4. Connect the yellow wire from the fan to the yellow wire marked
TO MOTOR from the receiver.
5. Connect the white wire from the fan to the white wire marked
FOR LIGHT from the receiver.
6. Connect the blue wire from the fan to the blue wire marked
FOR LIGHT from the receiver.
7. Connect the black (hot) wire from the ceiling to the black wire
marked “AC in L from the receiver.
8. Connect the white (neutral) wire from the ceiling to the white
wire marked “AC in N from the receiver.
NOTE: Failure to make correct wire connections can permanently
damage the receiver. Make certain you follow the below steps and
diagram.
FH-W2202-54LSkylark Flush Instructions 17
Follow the steps below to connect the fan to your household wiring. Use the plastic wire nuts with your fan.
Secure the plastic wire nuts with electrical tape. Make sure there are no loose strands or connections.
6
6A
1. Mounting Bracket
2. Receiver
Black(Hot)
can be RED from Switch leg
Black(Line in H)
RED(to Motor)
GREEN(Ground)
BLUE (to Light)
BLUE (for Light)
GREEN(GND Must Use)
GREEN(Motor Assembly Ground)
RED(to Receiver)
GREY(to Motor)
WHITE(Neutral)
WHITE(to Light)
WHITE(for Light)
GREY(to Receiver)
YELLOW(to Motor)
WHITE(Line in N)
YELLOW(to Receiver)
Outlet
Box
Receiver
1
2
FH-W2202-54L
Skylark Flush Instructions
18
7. Installing the Optional Wall Control
NOTE: Wall Control not included. A bluetooth wall control accessory
can be purchased separately.
1. Connect the green wire marked “GROUND” from the wall
control to the copper wire from the wall outlet box that
feeds back to the circuit breaker – important for proper
fan function (Fig. 6).
2. Connect the black wire marked “LINE IN” from the wall control to
the black LINE VOLTAGE wire from the wall outlet box that feeds
back to the circuit breaker (Fig. 6).
3. Connect the red wire from the wall control to the black wire from
the wall outlet box that feeds up to the fan (Fig. 6).
4. Connect the white wire from the wall control to the white
(neutral) wire from the wall outlet box (Fig. 6).
5. Carefully tuck the wire connections inside the outlet box.
Secure the wall control with the two (2) wall control screws
provided (Fig. 6A).
6. Attach the wall mounting plate over the wall switch and secure
with the two (2) wall mounting plate screws provided (Fig. 6A).
7. Fasten the wall plate to the wall mounting plate (Fig. 6A).
7
Wall Switch WiresHouse Wires
(Hot In)
(Neutral)
(Ground)
(Hot out to Fan)Fan Switch leg
(Copper/Ground)
(Neutral)
(Hot)
From Breaker
* Home Wiring may vary
to Fan
(Skip step if you did not purchase a wall control)
FH-W2202-54L Skylark Flush Instructions
19
7A
Multi-location wiring
1 2 3
54
1. Wall Outlet
2. Wall Control
3. Wall Mounting Plate
4. Mounting Plate Screws
5. Wallplate
Individually pair each of the wall controls with the fan
receiver using the pairing instruction. See page 22.
Line/Hot
Red
Green (Green or Bare)
Wall Control 1 Wall Control 2 Wall Control 3
If Applicable
FAN
Neutral/White
FH-W2202-54L
Skylark Flush Instructions20
8. Finishing Hanging the Fan
9. Installing Adapter Plate
1. Secure wire connectors with supplied wire ties.
2. Twist to loosen the trim ring from the motor housing. Remove 1
and loosen 2 mounting screws from the top of the fan’s housing.
Put 1 mounting screw aside. Remove the motor from the hook on
the mounting bracket. Slide the motor up to the mounting
bracket and twist lock the housing into place by aligning the
screws into the grooves of the mounting plate. Locate the 1
mounting screw you put aside and screw it into the 1 remaining
hole in the mounting bracket.
3.
4.
Tighten all 3 screws and twist the decorative trim ring into place
(Fig. 8A).
Make sure you align the grooves of the trim ring as show.
(Fig. 8B)
1. Remove 1 of 3 screws and loosen the others (do not remove).
2. Twist lock adapter plate into place.
3. Using the screw from the previous step, install the
adapter plate (Fig. 9).
/