ALGE-Timing Imposa User guide

Type
User guide
Version-D110314
Installation Manual
VGA and Offline Modus
Installation Manual
VGA and Offline Mode
Page 2
Important Information
General
Before using your ALGE-TIMING device read the complete manual carefully. It is part of the device and
contains important information about installation, safety and its intended use. This manual cannot
cover all conceivable applications. For further information or in case of problems that are mentioned
not at all or not sufficiently detailed, please contact your ALGE-TIMING representative. You can find
contact details on our homepage www.alge-timing.com
Safety
Apart from the information of this manual all general safety and accident prevention regulations of the
legislator must be taken into account.
The device must only be used by trained persons. The setting-up and installation must only be exe-
cuted according to the manufacturer’s data.
Intended Use
The device must only be used for its intended applications. Technical modifications and any misuse
are prohibited because of the risks involved! ALGE-TIMING is not liable for damages that are caused by
improper use or incorrect operation.
Power supply
The stated voltage on the type plate must correspond to voltage of the power source. Check all con-
nections and plugs before usage. Damaged connection wires must be replaced immediately by an au-
thorized electrician. The device must only be connected to an electric supply that has been installed
by an electrician according to IEC 60364-1. Never touch the mains plug with wet hands! Never touch
live parts!
Cleaning
Please clean the outside of the device only with a smooth cloth. Detergents can cause damage. Never
submerge in water, never open or clean with wet cloth. The cleaning must not be carried out by hose
or high-pressure (risk of short circuits or other damage).
Liability Limitations
All technical information, data and information for installation and operation correspond to the latest
status at time of printing and are made in all conscience considering our past experience and knowl-
edge. Information, pictures and description do not entitle to base any claims. The manufacturer is not
liable for damage due to failure to observe the manual, improper use, incorrect repairs, technical modi-
fications, use of unauthorized spare parts. Translations are made in all conscience. We assume no li-
ability for translation mistakes, even if the translation is carried out by us or on our behalf.
Disposal
If a label is placed on the device showing a crossed out dustbin on wheels (see drawing),
the European directive 2002/96/EG applies for this device.
Please get informed about the applicable regulations for separate collection of electrical
and electronically waste in your country and do not dispose of the old devices as household
waste. Correct disposal of old equipment protects the environment and humans against
negative consequences!
Copyright by ALGE-TIMING GmbH
All rights reserved. Any duplication, either in full or in part, requires the prior written consent of the
copyright holder.
Installation Manual
VGA and Offline Mode
Page 3
Table of Contents
1 Functions and Installation of LDU3000 (A).................................................................4
1.1 Functions of LDU3000 (A)......................................................................................4
1.2 Installation of LDU3000A........................................................................................6
2 Wiring and Application of LDU3000 (A)......................................................................7
2.1 Signal Diagram of IMPOSA Screen system...........................................................7
2.2 LDU3000/LDU300A- Connection to LED Screen...................................................8
2.3 LUD3000/LDU3000A-Connection to Light Sensor...............................................10
2.4 LDU3000/A-Connection and Communication to Computer..................................11
2.4.1 RS232............................................................................................................................................11
2.4.2 Communication via Ethernet..........................................................................................................12
2.4.3 Connecting VPU3000 or VGA1000 and LDU3000 via Optical Fibre..............................................13
3 Maintenance of LDU3000 (A)......................................................................................14
3.1 Backup LDU3000 to computer.............................................................................14
3.2 Restoration and Maintenance ..............................................................................14
3.2.1 Replacement of LDU3000..............................................................................................................14
3.2.2 Replacement of Optical Fibre and Optical Fibre Plug....................................................................14
4 Appendix......................................................................................................................16
4.1 Explanation for QS5003 in LDU3000HUB............................................................16
4.1.1 Layout of QS5003..........................................................................................................................16
4.1.2 Functions of Interfaces ..................................................................................................................16
4.1.3 Functions of Dip Switch SW1.........................................................................................................16
4.2 Parts.....................................................................................................................17
5 Notes............................................................................................................................18
Installation Manual
VGA and Offline Mode
Page 4
1 Functions and Installation of LDU3000 (A).
The LDU is available in 3 different versions.
The Function is always the same, but depending on the usage the LDU is built into different
boxes or in some displays it is even built in directly.
1.1 Functions of LDU3000 (A)
LDU3000: for indoor applications and fast installation of moveable LED screens, e.g.,
ALGE Kwic system.
483
396 68. 5
250
283
253
65
LDU3000
RUN
POWER
435
Installation Manual
VGA and Offline Mode
Page 5
LDU3000AFor outdoor use, with IP level of 54.
Fig.1
350
450
120
LDU3000A
Fig.2
Functions
With maximum: 16 signal outputs
Can be connected to VPU3000 to form a synchronous playing system
Can be used alone as an offline system; and can control maximum resolution of
1024X768
Communications: Fibre Optic (for synchronous system), Ethernet (Offline), RS232 (for
updating), RS485
Can be connected to Light Sensor and examine the real-time ambient brightness, in
order to adjust the brightness of screen automatically.
Installation Manual
VGA and Offline Mode
Page 6
1.2 Installation of LDU3000A
LDU3000A is waterproof and suitable for outdoor installation. It can be in-
stalled on the middle of the right side of LED screen (rear view).
LDU3000A can be fixed to frameworks with the below dimension:
LDU3000A
496
290
34
128
350
450
Fig.3
LDU3000A
396
39042
350
450
128
Fig.4
Installation Manual
VGA and Offline Mode
Page 7
2 Wiring and Application of LDU3000 (A)
2.1 Signal Diagram of IMPOSA Screen system
5002
CON2
CON3
JP7 SW1 SW2
J1
J2
J3
J4
J5
J6
JP2JP4
JP12
5002
CON2
CON3
JP7 SW1 SW2
J1
J2
J3
J4
J5
J6
JP2JP4
JP12
TX+ R
TX- B
RS+ G
RS- Y
5002
CON2
CON3
JP7 SW1 SW2
J1
J2
J3
J4
J5
J6
JP2JP4
JP12
TX+ R
TX- B
RS+ G
RS- Y
TX+ R
TX- B
RS+ G
RS- Y
5002
CON2
CON3
JP7 SW1 SW2
J1
J2
J3
J4
J5
J6
JP2JP4
JP12
5002
CON2
CON3
JP7 SW1 SW2
J1
J2
J3
J4
J5
J6
JP2JP4
JP12
TX+ R
TX- B
RS+ G
RS- Y
5002
CON2
CON3
JP7 SW1 SW2
J1
J2
J3
J4
J5
J6
JP2JP4
JP12
TX+ R
TX- B
RS+ G
RS- Y
TX+ R
TX- B
RS+ G
RS- Y
5002
CON2
CON3
JP7 SW1 SW2
J1
J2
J3
J4
J5
J6
JP2JP4
JP12
5002
CON2
CON3
JP7 SW1 SW2
J1
J2
J3
J4
J5
J6
JP2JP4
JP12
TX+ R
TX- B
RS+ G
RS- Y
5002
CON2
CON3
JP7 SW1 SW2
J1
J2
J3
J4
J5
J6
JP2JP4
JP12
TX+ R
TX- B
RS+ G
RS- Y
TX+ R
TX- B
RS+ G
RS- Y
A1-1A1-2
A1-m
A2-1A2-2
A2-m
An-1An-2
An-m
Rear View
CON2 CON2 CON2 CON3
CON3
CON3
CON2 CON2 CON2 CON3
CON3
CON3
CON2 CON2 CON2 CON3
CON3
CON3
TX+ R
TX- B
RS+ G
RS- Y
CON2
LDU3000A HUB BOX
TX+ R
TX- B
RS+ G
RS- Y
CON2
TX+ R
TX- B
RS+ G
RS- Y
CON2
GND
RS485
RS232
OPEN
MODE
COM1
SEL
TABLE OF SEL
LUM SENSOR
VCC
VCC
LUM
LUM
RS-
RS+
SEL
GND
GND
D-
D+
RXD2
RXD1
TXD1
TXD2
LINK
ACT
GND
CL
CH
+5V
P13P12P11P10P9P8P7P6P5P4P3P2P1
SENSOR COM2COM1
CON5
CON7 CON1
QS5003
CON9CON8
SW1
P14 P15 P16
DC 5V
P1
P2
Pn
P1
P2
DVI OUT DVI IN
VGA IN
USB
RS232 Video S-Video
Fiber optic
VPU 3000
PC
AC INPUT
84~260V USB
DVI DVI VGA
RS232
CVBS 1
S_VIDEO
Pb
YPr
CVBS 2
CVBS 3CVBS 4
INPUT
DVI
OUTPUT
325
RXDGND TXD
VGA Synchronous
PC
RS232
Enthernet
OFFLINE
Fig.5
Installation Manual
VGA and Offline Mode
Page 8
2.2 LDU3000/LDU300A- Connection to LED Screen
When LDU3000 HUB box may be connected to screen, the cabinet on top/bottom of the first
row from right of the screen (back view) should be connected to Port No.1 in LDU3000; the
cabinet of the second row should be connected to Port No.2 in LDU3000 and so on.
1 3 5 7 9 11 13 15
161412108642
RS485
D- D+ CHANNEL
TX RX
ETHERNET
SENSOR
AC INPUT
84~2 60V
5002
CON2
CON3
JP7 SW1 SW2
J1
J2
J3
J4
J5
J6
JP2JP4
JP12
5002
CON2
CON3
JP7 SW1 SW2
J1
J2
J3
J4
J5
J6
JP2JP4
JP12
5002
CON2
CON3
JP7 SW1 SW2
J1
J2
J3
J4
J5
J6
JP2JP4
JP12
A1-1A1-2A1-m
CON3CON3CON3
TX+ R
TX- B
RS+ G
RS- Y
CON2
TX+ R
TX- B
RS+ G
RS- Y
CON2
TX+ R
TX- B
RS+ G
RS- Y
CON2
1
2
n
Rear View
LDU3000 HUB
Fig.6
Installation Manual
VGA and Offline Mode
Page 9
When LDU3000A HUB box may be connected to screen, the cabinet on the right of the first
line of the screen (back view) should be connected to output Port No.1 in main board
QS5003 inside the LDU3000A; the cabinet of the second line should be connected to output
Port No.2 in main board QS5003 and so on.
5002
CON2
CON3
JP7 SW1 SW2
J1
J2
J3
J4
J5
J6
JP2JP4
JP12
5002
CON2
CON3
JP7 SW1 SW2
J1
J2
J3
J4
J5
J6
JP2JP4
JP12
5002
CON2
CON3
JP7 SW1 SW2
J1
J2
J3
J4
J5
J6
JP2JP4
JP12
A1-1
A2-1
An-1
CON3
CON3
CON3
TX+ R
TX- B
RS+ G
RS- Y
CON2
LDU3000A HUB
TX+ R
TX- B
RS+ G
RS- Y
CON2
TX+ R
TX- B
RS+ G
RS- Y
CON2
GND
RS485
RS232
OPEN
MODE
COM1
SEL
TABLE OF SEL
LUM SENSOR
VCC
VCC
LUM
LUM
RS-
RS+
SEL
GND
GND
D-
D+
RXD2
RXD1
TXD1
TXD2
LINK
ACT
GND
CL
CH
+5V
P13P12P11P10P9P8P7P6P5P4P3P2P1
SENSOR COM2COM1
CON5
CON7 CON1
QS5003
CON9
CON8
SW1
P14 P15 P16
DC 5V
P1
P2
Pn
Rear View
Fig.7
Note: for more about QS5003, please refer to the appendix.
Installation Manual
VGA and Offline Mode
Page 10
2.3 LUD3000/LDU3000A-Connection to Light Sensor
Light Sensor
Fig.8
LUD3000
Connect the provided Light Sensor directly to the Sensor interface at the back of LDU3000,
see the picture below:
CHANNEL 2
TX RX
CHANNEL 1
TX RX
CH2
CH1
Fig.9
LUD3000A
Connect the provided Light Sensor directly to the Sensor CON interface on main board
QS5003 of LDU3000A, see the picture below:
LDU3000A HUB Box
GND
RS48 5
RS232
OPEN
MODE
COM1
SEL
TABLE OF SEL
LUM SENSOR
VCC
VCC
LUM
LUM
RS-
RS+
SEL
GND
GND
D-
D+
RXD2
RXD1
TXD1
TXD2
LINK
ACT
GND
CL
CH
+5V
P13P12P11P10P9P8P7P6P5P4P3P2P1
SENSOR COM2 COM1
CON5
CON7 CON1
QS5003
CON9
CON8
SW1
P14 P15 P16
DC 5V
Fig.10
Installation Manual
VGA and Offline Mode
Page 11
2.4 LDU3000/A-Connection and Communication to Computer
GND
RS485
RS232
OPEN
MODE
COM1
SEL
TABLE OF SEL
LUM SENSOR
VCC
VCC
LUM
LUM
RS-
RS+
SEL
GND
GND
D-
D+
RXD2
RXD1
TXD1
TXD2
LINK
ACT
GND
CL
CH
+5V
P13P12P11P10P9P8P7P6P5
P4
P3P2P1
SENSOR COM2 COM1
CON5
CON7 CON1
QS5003
CON9
CON8
SW1
P14P15 P16
DC 5V
Fig.11
2 independent COM interfaces are in main board QS5003 of LDU3000/A.
COM1: RS232 or RS485; If SEL (connecting to GND) is selected, the communication
should be RS232; If SEL is suspended, the communication be RS485; RS232 and
RS485 cannot be used together.
COM2: RS232
1 Ethernet interface is on main board QS5003 of LDU3000/A.
CON1: Ethernet interface
For more about QS5003, please refer to the explanation below.
2.4.1 RS232
Where the system is offline, RS232 cable may be used to communicate with QS5003
to change screen content or settings.
Where it is VGA synchronous system, only RS232 cable should be used to update
CPU of QS5003.
The RS232 is used also for updating the Firmware of the LDU, therefore it is
mandatory to wire it to an easy accessible location
.
Installation Manual
VGA and Offline Mode
Page 12
2.4.1.1 Connection of RS232
If COM1 is used, the connection is as below:
GND
RS485
RS232
OPEN
MODE
COM1
SEL
TABLE OF SEL
LUM SENSOR
VCC
VCC
LUM
LUM
RS-
RS+
SEL
GND
GND
D-
D+
RXD2
RXD1
TXD1
TXD2
LINK
ACT
GND
CL
CH
+5V
P13P12P11P10P9P8P7P6P5
P4
P3P2P1
SENSOR COM2 COM1
CON5
CON7 CON1
QS5003
CON9
CON8
SW1
P14P15P16
DC 5V
GND
RXD1
TXD1
Fig.12
If COM2 is used, the connection is as below
GND
RS485
RS232
OPEN
MODE
COM1
SEL
TABLE OF SEL
LUM SENSOR
VCC
VCC
LUM
LUM
RS-
RS+
SEL
GND
GND
D-
D+
RXD2
RXD1
TXD1
TXD2
LINK
ACT
GND
CL
CH
+5V
P13P12P11P10P9P8P7P6P5
P4
P3P2P1
SENSOR COM2 COM1
CON5
CON7 CON1
QS5003
CON9
CON8
SW1
P14P15 P16
DC 5V
GND
RXD2
TXD2
Fig.13
Communication via RS485
GND
RS485
RS232
OPEN
MODE
COM1
SEL
TABLE OF SEL
LUM SENSOR
VCC
VCC
LUM
LUM
RS-
RS+
SEL
GND
GND
D-
D+
RXD2
RXD1
TXD1
TXD2
LINK
ACT
GND
CL
CH
+5V
P13P12P11P10P9P8P7P6P5P4P3P2P1
SENSOR COM2 COM1
CON5
CON7 CON1
QS5003
CON9
CON8
SW1
P14P15P16
DC 5V
RS-
RS+
Fig.14
2.4.2 Communication via Ethernet
Where the system is offline, Ethernet cable may be used to connect main board QS5003 of
LDU3000A to COM1 interface.
Installation Manual
VGA and Offline Mode
Page 13
2.4.3 Connecting VPU3000 or VGA1000 and LDU3000 via Optical Fibre
There two optical fibber interfaces in LDU, with one for data transmission, the other for hot
backup.
Fiber optic
13579111315
161412108642
RS485
D- D+ CHANNEL
TX RX
ETHERNET
SENSOR
AC INPUT
84~260V
LDU 3000
VPU 3000
AC INPUT
84~260V USB
DVI DVI VGA
RS232
CVBS 1
S_VIDEO
Pb
YPr
CVBS 2
CVBS 3CVBS 4
INPUT
DVI
OUTPUT
32
5
RXDGND TXD
Fig.15
In order not to affect the screen door from opening and closing, the wire and cables must fol-
low along the suction canals at the bottom of cabinets.
Installation Manual
VGA and Offline Mode
Page 14
3 Maintenance of LDU3000 (A)
3.1 Backup LDU3000 to computer
IMPOSA Tools program should be used. For operation details, please refer to User’s Manual
of IMPOSA Tools. Then you can save the LDU information to computer.
Select Tool\Backup LDU date\Save to computer
Select a location for saving backup file and name the file to be saved.
Press “Backup” button to start backing up and wait until it stops.
3.2 Restoration and Maintenance
3.2.1 Replacement of LDU3000
Replace the main board inside LDU. Change for a new LDU main board, and connect
it to power supply, communication cables and optic fibre. Do make sure that all con-
nections are the same as before.
Configure Parameters. Open IMPOSA Tools and select Tool\Recover\Recover from
computer, and confirm the prompting message, open the LDU backup file from your
computer, for example, backup.LDU.
Press Restore to start backing up and then wait until it ends. You can follow the same
operations to update all the LDU(s) (if there are many LDUs).
Switch off and restart the power supply of LDU.
Check if the screen can work normally.
3.2.2 Replacement of Optical Fibre and Optical Fibre Plug
Optical Fibre should be multimode.
For outdoor use, the optical fibre is usually fusion spliced by expertise on-site and
doesn’t need to change.
For indoor use the optical fibre is usually grafted in the optical fibre connector. So you
need to be careful when inserting or unplugging the optical fibre head, not to damage
it.
Please take the following steps to unplug the optical fibre:
Step 1 Step 2
Installation Manual
VGA and Offline Mode
Page 15
Step 3 Step 4
Step 5 Step 6
Please take the following steps to insert the optical fibre.
Step 1 Step 2
Step 3
Installation Manual
VGA and Offline Mode
Page 16
4 Appendix
4.1 Explanation for QS5003 in LDU3000HUB
4.1.1 Layout of QS5003
Optical Interface Dip Switch SW1
Ethernet Data Port Signal Output Port Port for
light sen-
sor
Power Input COM2 port COM1port
Port for Tempe-
rature and Hu-
midity
4.1.2 Functions of Interfaces
P1-P16: Data output interfaces, respectively connected to input of the first cabinet for
each line of the screen. Counted from top to bottom, the number is P1, P2, and P3…
COM1: RS232 or RS485; If SEL (connecting to GND) is selected, the communication
should be RS232; if SEL is suspended, it should be RS485.
COM2: RS232
COM7: Sensor CAN bus interface for light sensor, temperature sensor, humidity sen-
sor.
4.1.3 Functions of Dip Switch SW1
DIP1~DIP4=AD (4 ….0) Address Range0~7
Note: “0” means ON, “1” means OFF.
Installation Manual
VGA and Offline Mode
Page 17
4.2 Parts
Device Picture Model Part No Remarks
LDU3000
LDU3000 781-10001
LDU3000A
LDU3000A 781-10002
Main Board QS5003
QS5003 780-65002
Installation Manual
VGA and Offline Mode
Page 18
5 Notes
Installation Manual
VGA and Offline Mode
Page 19
Installation Manual
VGA and Offline Mode
Page 20
Subject to changes
Copyright by
ALGE-TIMING GmbH
Rotkreuzstr. 39
6890 Lustenau / Austria
www.alge-timing.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

ALGE-Timing Imposa User guide

Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI