Zanussi NH9015X User manual

Category
Cooker hoods
Type
User manual
Cappa
Cooker hood
Hotte de cuisine
Dunstabzugshaube
Dampkap
NH 9015
MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE
INSTALLATION, USE AND MAINTENANCE HANDBOOK
MANUEL D’INSTRUCTIONS POUR L’INSTALLATION, L’EMPLOI ET L’ENTRETIEN
HANDBUCH FÜR INSTALLATION, BEDIENUNG UND WARTUNG
INSTRUCTIES VOOR MONTAGE, GEBRUIK EN ONDERHOUD
2
INSTALLAZIONE ........................................................................................................................ 6
Avvertenze per la sicurezza ................................................................................................................. 6
Componenti .......................................................................................................................................... 6
Istruzioni per l’installazione .................................................................................................................. 7
Montaggio delle staffe di supporto e Fondale ................................................................................... 7
Montaggio del corpo cappa ............................................................................................................... 8
Connessione elettrica e controllo funzionale ....................................................................................8
Connessione aspirante o filtrante...................................................................................................... 9
Montaggio del camino telescopico .................................................................................................. 10
USO .......................................................................................................................................... 11
Avvertenze per la sicurezza ............................................................................................................... 11
Istruzioni per l’Uso .............................................................................................................................. 11
MANUTENZIONE ..................................................................................................................... 12
Filtri antigrasso metallici ..................................................................................................................... 12
Filtro al carbone attivo ........................................................................................................................ 12
Illuminazione ...................................................................................................................................... 13
Pulizia ................................................................................................................................................. 13
INSTALLATION ........................................................................................................................ 14
SAFETY WARNINGS ......................................................................................................................... 14
COMPONENTS ................................................................................................................................. 14
Installation instructions ....................................................................................................................... 15
Fitting the wall brackets and Splashback ........................................................................................15
Fixing the canopy ............................................................................................................................ 16
Electrical connection and working test ............................................................................................ 16
Ducting or Recirculation fitting ........................................................................................................ 17
Fitting the telescopic chimney ......................................................................................................... 18
OPERATION ............................................................................................................................. 19
Safety warnings .................................................................................................................................. 19
Instruction for Use .............................................................................................................................. 19
Control panel ................................................................................................................................... 19
MAINTENANCE........................................................................................................................ 20
Metal grease filters ............................................................................................................................. 20
Activated charcoal filter ...................................................................................................................... 20
Lighting ............................................................................................................................................... 21
Cleaning ............................................................................................................................................. 21
14 GB
INSTALLATION
This canopy hood is designed to be fixed to any rigid vertical surface, over a gas or
electric hotplate and can be used either in the extraction mode (ducted to the outside) or
in the recirculation mode (internal recycling).
SAFETY WARNINGS
Before commencing the installation, consideration should be given to the difficulties
to be found during installation and to the bulky weight of the hood. The installation
work must be undertaken by a qualified and competent person in conformity to the
rules concerning the evacuation of contaminated air. The manufacturer disclaims all
liability for any damage or injury caused as a result of not following the instructions
for installation contained in the following text.
When used in the extraction mode the cooker hood ducting must not be connected to
a flue which is used for exhausting fumes from appliances supplied with energy other
than electric such as a central heating flue or water heating flue.
When istalled, the hood must be positioned at least 65 cm above a cooking appliance.
Never do flambé cooking under this cooker hood.
Never leave frying pans unattended during use as overheated fats and oils may catch
fire.
If the room where the cooker hood is to be used contains a fuel burning appliance
such as a central heating boiler then this must be of the room sealed or balanced flue
type. If other types of flue or appliance are fitted en-sure that there is an adequate
supply of air into the room. When the cooker hood is used in conjunction with other
appliances supplied with energy other than electric, the negative pressure in the room
must not exceed 0,04 mbar to prevent fumes being drawn back into the room by the
cooker hood.
COMPONENTS
The hood comprises the following (fig.1 ):
No.1 canopy
C complete with controls,
lighting and ventilator unit
No.1 telescopic chimney, comprising:
No.1 upper chimney element
S
No.1 lower chimney element I
No.2 directional grills
G
No.1 reduction flange Ø 150-120
A
No.1 valve V (optional )
No.1 recirculation spigot
R
No.1 deflector
D
No.2 additional side recirculation spigots
P1
No.1 additional recirculation spigot
P
No.1 bag containing:
No.2 brackets
2 to fix the chimney,
screws, rawl plugs and documents.
No.1 splashback B (optional )
2
A
R
P1
D
P
G
G
B
V
S
I
C
Fig. 1
15GB
Installation instructions
For easy installation, proceed as follows:
Fix the wall brackets and Splashback
Fix the canopy
Connect the hood to the mains power supply and make sure that it works properly
Set the hood for ducting or recirculation
Fix the telescopic chimney
Fitting the wall brackets and Splashback
Please refer to (fig.2a-b):
Draw a vertical line on the
wall, from the centre of the
cooking appliance up to the
ceiling, using a marking pen.
This is to ensure the correct
vertical alignment of the
various parts.
Fixing the wall brackets
item
2:
a) Place one of the brackets
2
against the wall
approximately 1 or 2 mm
from the ceiling or from the
top limit, aligning its centre
(slot) with the vertical line.
b) Mark the centres of two
keyholes in the bracket on
the wall.
c) Rest the other bracket 2
against the wall, aligning it
with the vertical line, at a
distance X measured as
shown in fig. 2 equal to the height of the upper chimney element S supplied with the
hood. The position X may vary, according to the various sizes of upper chimney element
available.
d) Mark the centres of the keyholes in the bracket on the wall.
Drilling fixing holes item 1:
a) Mark a point on the vertical line at a distance from the cooking appliances of:
d =1024 min (distance without splashback).
d =height of splashback + 374 mm (distance with splashback).The distance H is the
minimum height in mm from the cooking appliances to the bottom edge of the front panel
of the hood.
b) At the point marked, draw a horizontal line parallel to the cooking appliances.
c) Drill two holes in the wall
1 using an 8 mm drill bit (fig.2a ), and insert the rawl plugs and
screws into the holes 1 (4.2 x 44.4 screws). Fix the screws, leaving a space of 5-6 mm
232
254
11
2
254
11
20
X
H min 650
d = 1024 min
Fig. 2
a b
16 GB
required to hook up the canopy. Small adjustments can be made
using the hood adjustment screws (see Fitting the canopy).
The hood should have a maximum excursion of 20 mm.
Splashback (optional)
When a splashback is to be fitted, the distance between the
hood and the cooking appliances will be determined by the
height of the splashback
B and whether or not there is a raised
back on the worktop. The splashback is to be installed before
installing the canopy. If the splashback is to be fixed to the
wall using both the top and bottom fixing holes, care must be
taken to ensure that the splashback is fitted at the correct height
before fixing the base units or at least the worktop covering
them. As this is a complex operation, it should only be
undertaken by the technician installing the kitchen units or
by a competent person who knows the final dimensions of
the units. If the splashback is to be fixed through the top
fixing holes only, proceed as follows:
a) Rest the splashback on the worktop and against the wall, as
illustrated in fig.2 .
b) Mark the centres of the two holes in the top surface.
c) Drill the wall using an 8 mm drill bit, and fix the splashback
using the rawl plugs and screws provided.
d) If necessary, the installer should secure the splashback to
the wall by tucking the bottom edge down behind the rear of
the worktop.
Fixing the canopy
Before starting to fix the canopy it will be necessary to adjust
the support brackets S1 by turning the adjustment screws in a
clockwise direction until their reach their limit (Fig.3):
a) Hook the canopy onto the two size 4.2 x 44.4 screws 1 fitted as
described above (Fig.4 ).
b) Level the hood by turning the adjustment screws and then locking
them.
Electrical connection and working test
Before connecting to the mains supply ensure that the mains
voltage corresponds with the voltage on the rating plate inside
the hood.
Connect the cooker hood to the mains via a double pole switch
which has 3 mm clearance between the contacts.
The appliance must be earthed.
Once the electrical connection has been completed, check that
worktop illumination, motor and speed work properly.
A
1
8
_
7
1
4
_
1
S1
S1
A
1
8
_
7
1
4
_
0
3
1
1
1
Fig. 3
Fig. 4
A
1
8
_
7
1
4
_
0
3
A
Fig. 5
17GB
Ducting or Recirculation fitting
Ducting fitting
The hood can be ducted to the outside using either rigid
or flexible ducting Ø 120 or 150 mm, the choice of which
is left to the installer. When 120 mm ducting is to be
used it will be necessary to install the reduction flange
item
A on the air outlet (fig.5).
When ducting the hood through the side air outlet from
the lower chimney element I it is necessary to insert
deflector D into spigot R to close off the opening that is
not being used (fig.6).
Connect the additional spigot P to the round fan outlet,
pushing it downwards, and fit spigot R to additional
spigot P in a similar manner (make sure that the two
additional side recirculation spigots P1 are fitted to spigot
R). Make sure that the height of the assembly R + P
corresponds to the height of the chimney outlet (fig. 7).
If the hood is supplied with the activated charcoal filters
fitted, the filters should be removed (see paragraph on
Maintenance ).
Recirculation fitting
The filtered air is returned to the room through
the two plastic side grills G on the lower chimney
element I .
Connect the additional spigot
P to the round fan
outlet, pushing it downwards, and fit spigot R to
additional spigot P in a similar manner (make
sure that the two additional side recirculation
spigots P1 are fitted to spigot R). Make sure that
the height of the assembly R + P corresponds to
the height of the chimney outlet.(fig.7).
Fit the activated charcoal filters inside the canopy
(see paragraph on Maintenance ). Do not fit the
venting grilles until after the chimney has been
installed.
D
R
P1P1
P
Fig. 6
R
P1P1
P
G
A
1
8
_
7
1
4
_
0
3
Fig. 7
18 GB
Fitting the telescopic chimney
To fit the upper section S first expand the two
side pieces slightly, hook them behind the
brackets 2 and close them together again
until they touch. Fix the upper section S to
the brackets 2 using four of the screws
provided in the bag of accessories (fig. 8).
Fit the lower section I as above, between the
upper section S and the canopy C using two
of the screws provided in the bag of
accessories.
Chimney with venting grilles: Snap the
venting grilles into position in the apertures
located on the chimney section, so that the
symbol
is turned upwards and the symbol
faces forwards. Also, when the hood is
used in recirculation mode, ensure that the
grilles are properly secured to the inside of
the recirculation spigot
R (fig.9).
G
A
1
8
_
7
1
4
_
0
3
2
S
I
2
C
Fig. 8
Fig. 9
19GB
OPERATION
Safety warnings
Before carring out any kind of maintenance or cleaning, disconnect the hood from the mains
supply.
The grease filters and the charcoal filter should be cleaned or replaced as recommended by
the manufacturer or more frequently if the hood is used consistently over 4 hours per day.
When using a gas hob in connection with the cooker hood never leave the burners of the
hob uncovered while the hood is in use or when the pans have been removed. Switch off
the gas before removing the pan, or for just short periods and never leave the hob unattended.
Always ensure that the flame is kept at the correct intensity to prevent the flame from
licking round from the bottom of the pan; this will save energy and will avoid a dangerous
concentration of heat.
Always ensure that the appliance is used in accordance with the manufacturer’s
instructions for the removal of contaminated air and odours during cooking.
Instruction for Use
Control panel
The layout of the control panel is as follows:
Key T1 = Turns the lighting system on and off
Key T2 = Turns the motor on and off
Key T3 = Decreases the working speed
Key T4 = Increases the working speed
Key T5 = Intensive speed with timed stoppage. Suitable to deal with maximum vapour
emission, this turns off automatically 10 minutes after starting operation. It
can be disabled by pressing the key T5.
FC
T1 T2 T3 T4 T5
20 GB
MAINTENANCE
Constant maintenance guarantees proper operation and long-term reliability. Particular
attention should be paid to the metal grease filters and, for recirculation hoods only, to
the activated charcoal filters. The appliance is equipped with a system that indicates
automatically when it is time to carry out maintenance operations
Metal grease filters
Cleaning
These filters must be washed when
LED
T2 starts to flash, or at the most
once every 2 months, using a normal
household detergent; their compact
size also enables them to be washed
in a dishwasher.
Removing the filters
Remove one filter at a time, supporting
it from below and pulling back the
stainless steel handle (fig.10).
Replace, making sure that the handle
is still facing towards the outside.
Enabling the alarm signal
The hood is already set up to trigger
an alarm indicating saturation of the
metal grease filters, so this function does not need to be enabled.
Resetting the alarm signal
To turn the alarm signal off, proceed as follows:
- Turn off the lights
T1 and the suction motor T2;
- Press the T4 button for at least 3 seconds, until the LEDs flash in confirmation. In any
case the saturated filters alarm will only come into operation when the suction motor is
turned on.
WARNING: always comply with the maintenance and replacement times indicated,
in order to avoid a possible risk of fire when the filters are saturated with grease.
Activated charcoal filter
Operation
The activated charcoal filter is only fitted in recirculation type hoods. It will retain odours
until it becomes saturated. It cannot be washed or regenerated, and must be replaced
when the
T5 LED starts to flash, or at least once every 4 months of use. Attention: in
recirculation type hoods the T2 LED may start to flash as well as the T5 LED. This
indicates that as well as replacing the activated charcoal filter, it is also necessary to
perform maintenance operations on the metal grease filters.
Fig. 10
21GB
Replacing
Remove the grease filters and take out the
activated charcoal filter from its housing, turning
the lugs provided (fig. 11). Insert the new activated
charcoal filter and replace the metal grease filters.
Enabling the alarm signal
In recirculation type hoods the saturated filters
alarm must be enabled as indicated below:
- Turn off the lights
T1 and the suction motor T2;
- Press and hold the T4 button for at least 10
seconds, until the LEDs start to flash. Note the
number of flashes:
- 2 flashes of the LED Activated charcoal filter
saturation alarm ENABLED.
- 1 flash of the LED Activated charcoal filter
saturation alarm DISABLED;
Resetting the alarm signal
To turn the alarm signal off, proceed as follows:
- Press the T4 button for at least 3 seconds, until the LEDs flash in confirmation. In any
case the saturated filters alarm will only come into operation when the suction motor is
turned on.
WARNING: always comply with the maintenance and replacement times indicated,
in order to avoid a possible risk of fire when the filters are saturated with grease.
Lighting
Version with halogen spotlights:
90 cm model two 20W halogen
spotlights.
To replace (fig.12)
Remove the two screws fixing the metal
ring, extract the spotlight from the lamp
holder by pulling gently. When replacing
the spotlight, make sure that the two pins
are correctly inserted in the housing on
the lamp holder.
Cleaning
When cleaning the hood:
- Never use a wet cloth or sponge, or running water.
- Never use thinners or products containing alcohol, as they might damage the paintwork.
- Never use abrasive cleaning materials, in particular when cleaning stainless steel surfaces.
It is recommended to use a damp cloth and mild liquid household cleaner.
Fig. 11
Fig. 12
Quest’apparecchio é conforme alla norma europea sulla bassa tensione C.E.E. 73/23 relativa
alla sicurezza elettrica e alle norme europee: C.E.E. 89/336 relativa alla compatibilità elettro-
magnetica e C.E.E. 93/68 relativa alla marcatura CE.
This appliance complies with European regulations on low voltages, EEC Directive 73/23 on
electrical safety, and with the following European regulations: EEC Directive 89/336 on
electromagnetic compatibility and EEC Directive 93/68 on EC marking.
Cet équipement est conforme à la norme européenne sur la basse tension C.E.E. 73/23
relative à la sécurité électrique et aux normes européennes: C.E.E. 89/336 relative à la
compatibilité électromagnétique et C.E.E. 93/68 relative au marquage CE.
Dieses Gerät entspricht den europäischen Niederspannungsrichtlinien 73/23/EWG zur
elektrischen Sicherheit, den europäischen Richtlinien 89/336/EWG zur elektromagnetischen
Verträglichkeit und den Richtlinien 93/68/EWG zur CE-Kennzeichnung
Dit apparaat voldoet aan de Europese Laagspanningsrichtlijn 72/23/EEG inzake de elektrische
veiligheid en aan de Europese normen 89/336/EEG inzake de elektromagnetische
compatibiliteit en 93/68/EEG inzake de CE-markering.
4329574 01 - 010118
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

Zanussi NH9015X User manual

Category
Cooker hoods
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI