Airwell PNV 007 Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Airwell PNV 007 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
INSTALLATION MANUAL
MODELS
Wall-mounted type
PNV 007 PNV 015
PNV 009 PNV 018
PNV 012 PNV 021
SAFETY PRECAUTIONS
Part NO:468050156/02
● Readthefollowing"SAFETYPRECAUTIONS"carefullybeforeinstallation.
● Carryouttestrunningtoconrmthatnoabnormalityoccursaftertheinstallation.Then,explaintousertheoperation,careandmaintenanceas
statedininstructions.Pleaseremindthecustomertokeeptheoperatinginstructionsforfuturereference.
Thisindicationshowsthepossibilityofcausingdeathorseriousinjury.
WARNING
Thisindicationshowsthepossibilityofcausingharmordamagetheequipment.
CAUTION
WARNING
1)Usequaliedinstallerandfollowcarefullythisinstructions.Otherwiseitwillcauseelectricalshock,waterleakage,orestheticproblem.
2)Installatastrongandrmlocationwhichisabletowithstandtheset'sweight.Ifthestrengthisnotenoughorinstallationisnotproperlydone,theset
willdropandcauseinjury.
3)Forelectricalwork,followthelocalnationalwiringstandard,regulationandthisinstallationinstruction.Anindependentcircuitandsingleoutletmust
beused.Ifelectricalcircuitcapacityisnotenoughordefectfoundinelectricalwork,itwillcauseelectricalshockorre.
4)Usethespeciedcableandconnecttightlyforindoorconnection.Connecttightlyandclampthecablesothatnoexternalforcewillbeactedonthe
terminal.Ifconnectionorxingisnotperfect,itwillcauseheat-uporreattheconnection.
5)Wireroutingmustbeproperlyarrangedsothatcontrolboardcoverisxedproperly.Ifcontrolboardcoverisnotxedperfectly,itwillcauseheat-up
atconnectionpointofterminal,reorelectricalshock.
6)Whencarryingoutpipingconnection,takecarenottoletairsubstancesotherthanthespeciedrefrigerantgointorefrigerationcycle.Otherwise,it
willcauselowercapacity,abnormalhighpressureintherefrigerationcycle,explosionandinjury.
7)Donotdamageoruseunspeciedpowersupplycord.Otherwise,itwillcausereorelectricalshock.
8)Thisequipmentmustbeearthed.Itmaycauseelectricalshockifthegroundingisnotperfect.
9)Donotinstalltheunitatplacewhereleakageofammablegasmayoccur.Incasegasleaksandaccumulatesatsurroundingoftheunit,itmay
causere.
CAUTION
1)Selectionoftheinstallationlocation.
Selectainstallationlocationwhichisrigidandstrongenoughtosupportorholdtheunit,andselectalocationforeasymaintenance.
2)Donotreleaserefrigerant.
Donotreleaserefrigerantduringpipingworkforinstallation,reinstallationandduringrepairingarefrigerationparts.Takecareoftheliquidrefrigerant.
itmaycausefrostbite.
3)Itmayneedtwopeopletocarryouttheinstallationwork.
4)Donotinstallthisapplianceinalaundryroomorotherlocationwherewatermaydripfromtheceiling,etc.
5)Carryoutdrainagepipesasmentionedininstallationinstructions.Ifdrainageisnotperfect,watermayentertheroomanddamagethefurniture.
IM_PNV_1 A 1_GB
Required tools for Installation
NO. TOOI NO. TOOI.
1 Screwdriver 7 Knife
2
Electricdrill,hole
coredrill(60mm)
8 Measuringtape
3 Hexagonalwrench
9 Torquewrench
4 Spanner
5 Pipecutter
6 Reamer
Attached accessories
No. Accessories part Qty.
1
Mountingplate
1
2
Airpurifyinglter(optional)
1
3
Swrewswasherdowels
4
4
Unitoperationmanual
Installationmanual
1
1
SELECT THE BEST LOCATION
2
HOW TO FIX INSTALLATION PLATE
Thereshouldnotbeanyheatsourceorsteamneartheunit.
Thereshouldnotbeanyobstaclesblockingtheaircirculation.
Aplacewhereaircirculationintheroomisgood.
Aplacewheredrainagecanbeeasilydone.
Donotinstalltheunitnearthedoorway.
Ensurethespacesindicatedbyarrowsfromthewall,ceiling,fenceorotherobstacles.(Fig1)
Theapplianceshallbeinstalledover2.3mhigh.
Themountingwallisstrongandsolidenoughtopreventitfromthevibration.
Theedgeofinstallationcartonboardshouldbeatmorethan50mmatrightandleftofthewall.
1.Locatethemountingplateonthewallinahorizontalposition.
2.Markthepositionofthefourmountingholesonthewallanddrillfourholestoaccommodatethedowels.
3.Mountthemountingplateonthewallbythefourscrews.Ensurescrewsaretightenedproperly.
4.Markthelocationofthepipingholeoneithersideofthemountingplateasshown.
5.Thepipingholeisdrilledata5down-wardangletopreventcondensedorrainwalerfrompenetratingbackintotheroom.
6.Trimtheholeinthewallwitha70mmcommercialplastictube.
PNV 007
PNV 009
PNV 012
Fig1-1
50mm
min
50mm
min
PNV 015
PNV 018
PNV 021
3
UNIT INSTALLATION
Unitoffersvedirectionsforinstallingrefrigerantpipe,pleaseinstallingtheunitaccordingtofollowinginstalltion:
1.Knockoutholeandpulloutthepipes. 4.Purifyinglterinstallation(optional).
2.Installtheunittowall. 5.Checkthedrainage.
3.Securetheunit.
Pull out the piping and hose
Install the Indoor Unit
1.Hook the indoor unit onto the upper portion of
installationplate(Engagetheindoorunitwiththe
upper edge of the installation plate).ensure the
hooksareproperlyseatedontheinstallationplate
bymovinginleftandright.
2.Usedtheinstallationsupport thatassembletothe
unithousingtosupport the indoorunitinaangle
about25",thanconnectedthepiping and power
supplycord.
Movethedrainhosenear
toarrowmarkandtapeit
withpipinginapositionas
mentionedinFig.below
Coverforthe
rightpiping
Coverforthe
bottompiping
Coverforthe
leftpiping
Drainhose
Piping
Piping direction
Right
Rightrear
RightBottom
LeftRear
Left
(Frontside)
Hooksat
installationplate
Piping
Drainhose
Fig1-2
Install the Indoor Unit(Continue)
Totakeouttheunit,pullthe
markingatthebottomunit,andpullit
slightlytowardsyoutodisengagethe
hooksfromtheunit.
Purifying lter installation (optional)
1.Openthegrille.
2.Removetheairfilters.
3.Putairpurifyingfilterintoplaceasshowninillustration.
Secure the Indoor Unit
1.Tapetheextraconnectingcableinabundleandkeepitbehindthe
chassis.Ensurethattheconnectingcableisnotclampedinbetween
theunit'shook(2positions)andinstallationplate.
2.Pressthelowerleftandrightsideoftheunitagainsttheinstallation
plateuntilhooksengageswiththeirslots(soundclick).
marking
Attentionnottobend
updrainhose
Rearview
Unit's
hook
Installation
plate
Insulationofpipingconnections
●Carryoutinsulationafterchecking
forgasleaksandsecurewithvinyl
tape.
Vinyltape
Collaboratethepiping
communication
wiring
Drainhose
Adjustthepipingslightlydownwards.
Airpurifyinglter
Airlter
1Bendthepipeas
closelyonthewallas
possible,butbecareful
thatitdoesn’tbreak.
2Donotwiringthe
powerwireand
communicationwire
together.
How to take out front grille
Pleasefollowthestepsbelowtotakeoutfrontgrilleifnecessaryduringservicing.
1.Settheverticalairflowdirectionlouvertothehorizontalposition.
2.SlidedownthetwocapsofPNV007/009/012onthefrontgrilleasshownin
theillustrationatright,thenremovethetwomountingscrews.(Iftheunitis
PNV015/018/021,ithasthreecaps).
3.Pullthelowersectionofthefrontgrilletowardsyourtoremovethefrontgrille.
Check the drainage
1Openfrontpanelandremoveairfilters.
(Drainagecheckingcanbecarriedoutwithoutremovingthefrontgrill).
2Pouraglassofwaterintothedraintray-styrofoam.
3Ensurethatwaterflowsoutfromdrainhoseoftheindoorunit.
Height Compensation Setting
TheCompensationsettingaccordingtoinstallationheightcanbedonebyusingthedipswitch11and12oncontrollerPCB.
InstallationHeight HeightCode DS11 DS12
2.3-2.7(m) H0 OFF OFF
2.7-3.1(m) H1 OFF ON
3.1-3.5(m) H2 ON OFF
>3.5(m) H3 ON ON
Note
1.Pleasedisconnecttheunitfrompowersupplywhenchangethesesettings.
2.Ifyoufeeltoonoisy,pleasesetDS11andDS12tolowerheightcodelevel.
Verticalairow
deectionlouver
(Movethevertical
vanetohorizontal)
Draintraystyrofoam
4
ELECTRICAL WRING CONNECTION
Terminalblock(4P)
Powersupply
Terminalblock(2P)
Powersupplywiring
Tiethecommunicationwiringwithclamptightening
Fixthepowersupplywiringunderthecliptightening
Connect the drainage pipe
1UsestandardhardPVCpipe(19mm)forthedrainpipe.
2Usethedrainhosetochangethedirection.
3Insertthedrainhoseuntilitconnectsthedrainportverywell,andthensecureittightlywiththehoseclamp.
4Aftercheckingthedrainage,wrapthedrainhosewiththeinsulationandclamps.
Powersupplywiring
Tighteningtotorquefortheterminalscrews
Electricalcharacteristic
SpecicationsforeldsuppliedELBandwire
MainbusandR/Ccommunciationwiring
1.Unscrewandremovetheservicelid.
2.Connect the power supply wiring to the power supply
terminalblock.
3.Whendoingthis,pressthe powersupplywiring underthe
wirecliptightly.
1.Usethecorrectscrewdriverfortighteningtheterminalscrews.Ifthebladeofscrewdriveristoosmall,theheadofthescrewmightbedamaged,andthe
screwwillnotbeproperlytightened.
2.Iftheterminalscrewsaretightenedtoohard,screwsmightbedamage.
3.Refertothetablebelowforthetighteningtorqueoftheterminalscrews.
1.Unscrewandremovetheservicelid.
2.ConnecttheR/CwiringstoR1,R2terminalblockandthe
mainbuswiringstoF1,F2terminalblock.
3.Pressthewiringsunderthewirecliptightly.
Terminal Size Tighteningtorque
Remotecontroller,Transmissionwiringandforcedoffterminalblock(4P) M3.5 0.8~1.0N.m
PowersupplyandGroundterminalblock(3P) M4 1.2~1.5N.m
Unit Powersupply Fanmotor
Model Hz Volts MCA MFA KW FLA
LEV22
50 220~240
0.23 16 0.02 0.06
LEV28 0.23 16 0.02 0.06
LEV36 0.23 16 0.02 0.06
LEV45 0.23 16 0.02 0.07
LEV56 0.23 16 0.02 0.07
LEV63 0.23 16 0.02 0.07
MCA:Min.CircuitAmps(A)
MFA :Max.FuseAmps(A)
KW :FanMotorRatedoutput(KW)
FLA :FullLoadAmps(A)
Model Powersupplywiring
Remotecontrollerwiring
communicationwiring
PNV007 FieldELB WireandSize Wire Size
PNV009
16A
Mustcomply
withmaximum
currentandlocal
codes(≥0.75mm
2
)
Twisted-
pairwires
≥1.0mm
2
PNV012
PNV015
PNV018
PNV021
All fieldsupplied parts andmaterials and electrics worksmust
conformtolocalcodes.
Usecopperwireonly.
Allwiringmustbeperformedbyanauthorizedelectrician.
Everyindoorunitmusthavea subcircle breakerandthewhole
systemmusthaveamaincirclebreaker.
Besuretogroundtheairconditioner.
The appliance shall be installed in accordance with national
wiring regulations, and shall be provided to ensure all-pole
disconnectionfromthesupplymains,anddistancebetweenthe
polesshallbemorethan3mm.
CHECK ITEMS
BEFORE POWER ON
Isthereanygasleakageatarenutconnections?
Hastheheatinsulationbeencarriedoutatarenutconnection?
Istheconnectingcablebeingxedtoterminalboardrmly?Isthe
connectingcablebeingclampedrmly?
Isthedrainageok?
(Referto"Checkthedrainage"section)
Istheearthwireconnectionproperlydone?
Istheindoorunitproperlyhookedtotheinstallationplate?
Isthepowersupplyvoltagecompliedwithratedvalue?
AFTER POWER ON
Isthereanyabnormalsound?
Isthecoolingoperationnormal?
Isthethermostatoperationnormal?
Istheremotecontrol'sLCDoperationnormal?
NOTE:Forthepipingandwiringmethods,leakagetest,vacuumprocessandinstallationsetting
throughHMI,pleaserefterto“OutdoorunitInstallationManual”.
NOTE:Forhowtoconnectthepowerwireandcommunicationwirebetweenoutdoorunitandindoorunits,pleasereferto
chapter9“FieldWiring”inoutdoorunitinstallationmanual.
/