L 1030-10
Ladeleiste für 10 HF- und IR-Kinnbügelempfänger
Charging unit for up to 10 RF/IF stethoset receivers
Réglette de recharge pour 10 récepteurs stéthoscopiques
Striscia di ricarica per 10 ricevitori ad alta frequenza
Regleta de carga para 10 receptores de alta frecuencia
Laadstrip voor 10 HF-/IR-kinbeugel-ontvangers
1
3
2
4
6
5
L 1030-10
THE STETHOSET RECEIVERS ARE NOT
INCLUDED IN THE SUPPLY SCHEDULE!
Charging unit for charging up to ten HDE 1030 (all versions) tourguide or HDI 1029
PLL (all versions) infra-red receivers. The front of the charging unit features a socket
for connection of the NT 92 mains unit. The second socket is for linking one additional
charging unit using the KK 1030 connecting cable. Thus, one mains unit can supply two
charging units.
PUTTING THE CHARGING UNIT INTO OPERATION
Plug the mains connector into the mains a, then connect the mains unit to the charging
unit b. After approx. 2 seconds, the LED "CHARGE" f lights up and the charging
unit is ready for operation.
As soon as the charging unit is connected to the mains, the device automatically switches
to normal charging (16 hours). The red LED "CHARGE" f lights up and the charging
process is also indicated by the control LEDs e at the occupied charging compartments.
CHARGING THE RECEIVERS
Switch off the receivers and and insert them into the charging compartments.
STARTING THE CHARGING PROCESS
By pressing button c, the normal charging process begins. The charging process
is indicated by the red control LEDs e at the charging compartments and the
LED "CHARGE" f.
The automatic charging process (timer-controlled) will be completed after 16
hours. The LED "CHARGE" f goes off.
TRICKLE CHARGING
After a charging time of 16 hours, the charging unit automatically switches to trickle
charging. The LED "TRICKLE" d lights up. The accuplugs will now be supplied with
a small current (1.5 mA) to maintain their voltage. There is no time limit to this type of
charging, it will not damage the accuplugs. Trickle charging ensures that your receivers
are always ready for use, even when they have not been used for a long period of time.
ESSENTIAL NOTES
The charging process "CHARGE" cannot be interrupted. By pressing button c
again, the charging timer is reset and the charging process starts over again.
A power failure also resets the charging timer and the charging process starts over
again.
Switch off the receivers before starting the charging process!
For additional information on the use of the HDE 1030 and HDI 1029 receivers
please refer to the corresponding operating instructions.
TECHNICAL DATA L 1030-10
Charging compartments 10
Charging current at normal/trickle charge 4.6/1.5 mA
Charging time approx. 16 h
Power supply NT 92
Weight without receivers approx. 400 g
Dimensions in mm 325 x 98 x 42
Available mains units: NT 92 230 V, 50-60 Hz
NT 92-120 120 V, 50-60 Hz
NT 92-UK 240 V, 50-60 Hz
ALWAYS RECHARGE THE ACCUPLUGS AFTER USE!
Sennheiser electronic GmbH & Co. KG
Telefon: 05130/600-0
Telefax: 05130/600-300
D-30900 Wedemark
Printed in Germany Publ. 4/98 69365 / A02
Änderungen vorbehalten
Subject to alterations
Sous réserve de modifications
Con riserva di modifiche
Reservado el derecho a introducir modificaciones
Wijzigingen voorbehouden
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Sennheiser L 1030-10 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI