CDL06-13WS935S-U

universal douglas CDL06-13WS935S-U Operating instructions

  • Hello! I'm an AI assistant, and I've reviewed the user manual for Universal Douglas LED downlight fixtures, models CDL06-13WS935S-U, CDL08-23WS935S-U, and CDL10-29WS935S-U. This manual provides instructions for installation, highlighting features such as switchable power and CCT settings, dimmability and suitability for damp locations. I'm ready to answer any questions you have about these products.
  • What should I do before installing the fixture?
    Who should perform the installation?
    When should the power be disconnected?
    Where are the power and CCT selector switches located?
Product Information
ModelNo. Size D1 D2 HCut-out
Min. Max.
CDL06-13WS935S-U 6" 8-7/165-7/84-7/16
φ6
-
1 / 8 ”
φ7
-
3/16”
CDL08-23WS935S-U 8" 10-1/167-3/84-3/4” φ7-9/16
φ8
-
11/1 6
CDL10-29WS935S-U 10" 11-3/88-11/165-1/4
φ8
-
7 / 8 ”
φ 1 0 ”
3000K 3500K 4000K
Universal Douglas’s switchable round LED recessed downlight fixtures allow for selecting between three power
levels and three CCT settings to match a wide range of applications.
The power level and CCT selector switches are on the backside of the fixture and should be set prior to installation.
CUS
Intertek
501028 3
3000K
3500K
4000K
CDL06-13WS935S-U CDL08-23WS935S-U CDL10-29WS935S-U
Universal Lighting Technologies
3/15/2022
Page 1
WARNING: First please read all product labels and instruction before installing fixture. Risk of fire
or electric shock. LED Retrofit Kit installation requires knowledge if luminaires electrical systems.
Installation should be performed only by a qualified electrician in accordance with the National
Electrical Code and relevant local code. Install this kit only in the luminaires that have the
construction features and dimensions shown in the photographs and/or drawings. To prevent
wiring damage or abrasion, do not expose wiring to edges of sheet metal or another sharp object.
Do not make or alter any open holes in an enclosure of wiring or electrical components during kit
installation. The recessed luminaire will be exposed to damp or dry locations.
INSTALLATION SHOULD ONLY BE PERFORMED AFTER POWER TO THE FIXTURE HAS BEEN
DISCONNECTED. THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A SUITABILITY OF THE
COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION.
45
23
Note: Class 2 driver, risk of electric shock, The junction box needs to connect to the "ground wire";
Step 1: Make sure the POWER is Turned OFF when installing the products:
Step 2: Select the CCT and Lumen level with the dip switches (Fig. 1)
Step 3: Attach the carabiner safety clip to the existing fixture housing ( Fig.2)
Step 4: Insert lamp conduit into the J-box and wire to power source (black to hot, white to neutral, violet to
0-10V dimming positive, gray to 0-10V dimming negative) (Fig. 3). Reattach J-box cover when done; Step
5: Squeeze the two housing clips so they are in an upright position and insert lamp into opening (Fig.4);
Step 6 : Once lamp is inside the opening, release the housing clips and continue pushing lamp into
opening until securely fixed an ush with ceiling (Fig.5);
Step 7: Restore power at the source and the installation is complete.
Universal Lighting Technologies
Page 2
3/15/2022
/