INSTALLATION,USE&CAREMANUAL
48”FREESTANDINGDUALFUELRANGES
ModelsPRO486GDFSX [MTYKPZU7X5DUA]
ModelsPRO486GDFSAR [MTYKPZU7S5DUA]
ModelsPRO486GDFSBI [MTYKPZU7W5DUA]
ModelsPRO486GDFSNE [MTYKPZU7N5DUA]
ModelsPRO486GDFSRO [MTYKPZU7R5DUA]
ModelsPRO486GDFSVI [MTYKPZU7L5DUA]
ModelsPRO486GDFSGI [MTYKPZU7I5DUA]
ModèlesMAS486GDFSXT [
MTYKPZA7X5DUA]
 
310835
2
BERTAZZONISpA
ViaPalazzina8
42016GuastallaRE
ITALY
WWW.BERTAZZONIITALIA.COM
FromthedeskofthePresident
DearnewownerofaBertazzoniproduct,
Iwanttothankyouforchoosingoneofour
beautifulPROranges.Weknowthatyouhavemany
brandsandproductstochoosefromandweare
thrilledthatyouhavedecidedtotakeoneofyour
productsintoyourhome.
Wetake
asmuchprideinmakingourrangesaswe
hopeyouwillinowningthem.Myfamilystarted
manufacturingcookingappliancesin1882.Eachof
ourproductsisablendofItaliandesignfinesseand
superiorappliancetechnolo gy.Whilewecannot
replaceyouruniquetalentatcookingdelicious
recipes
foryourself,yourfamilyandyourfriends,
wetryourbesttomakecookingeasier,more
effectiveandmorefun.
Ourappliancesaredesignedaccordingtothe
strictestsafetyandperformancestandardforthe
EuropeanandtheNorthAmericanmarket.We
followthemostadvancedmanufacturing
philosophy.Eachapplianceleavesthe
factoryafter
thoroughqualityinspectionandtesting.Our
distributorsandourservicepartnersarereadyto
answeranyquestionsyoumayhaveregardinghow
toinstall,useandcareforyourBertazzoniproduct.
Thismanualwillhelpyoulearntousetheproduct
inthesafestandmosteffectivemanner
andcare
foritsothatitmaygiveyouthehighestsatisfaction
foryearstocome.
Themanualalsoincludesdirectionsforthe
professionalinstallerthatwillinstalltheproductin
yourhome.Werecommendusingfactorytrained
professionalsforthedelicatetaskofinstallingand
testingappliancesinyour
home.Pleasecall
CustomerServiceifyouneedhelplocatinga
factorytrainedprofessionalinstallerinyourarea.
Pleasekeepthismanualforfutureuse.
Grazie!
3
TABLEOFCONTENTS
WARRANTYANDSERVICE........................................................................................................................................5
CUSTOMERSERVICE.......................................................................................................................................................5
REPLACEMENTPARTS....................................................................................................................................................5
IMPORTANTSAFETYINFORMATION........................................................................................................................6
BEFOREINSTALLATION............................................................................................................................................9
INSTALLINGTHELEGS............................................................................................................................................10
INSTALLINGTHEWORKTOPFRONTGUARD............................................................................................................10
INSTALLINGTHEBACKGUARD............................................................................................................................... . 11
INSTALLATIONREQUIREMENTS.............................................................................................................................12
ELECTRICAL..................................................................................................................................................................12
GAS...............................................................................................................................................................................12
INSTALLATIONADJACENTTOKITCHENCABINETS...................................................................................................13
EXHAUSTHOODINSTALLATION.............................................................................................................................13
ELECTRICALCONNECTION......................................................................................................................................14
WIRINGDIAGRAM.................................................................................................................................................17
GASCONNECTION.................................................................................................................................................19
PRESSUREREGULATOR................................................................................................................................................20
GASCONVERSION.................................................................................................................................................20
STEP1:PRESSUREREGULATOR....................................................................................................................................20
STEP2:SURFACEBURNERS..........................................................................................................................................21
STEP3:MINIMUMFLAMEADJUSTMENT.....................................................................................................................21
GASBURNERSDATATABLES..................................................................................................................................22
INSTALLATIONCHECKLIST............................................................................................................................... .......23
INSTALLATIONCHECKLIST............................................................................................................................... .......23
FINALPREPARATION.............................................................................................................................................23
USERMANUAL......................................................................................................................................................24
ROOMVENTILATION.............................................................................................................................................24
SURFACEBURNERLAYOUT....................................................................................................................................25
SURFACECOOKING................................................................................................................................................25
SYMBOLS......................................................................................................................................................................25
SURFACEBURNEROPERATION....................................................................................................................................26
TIPSFORUSINGBURNERSCORRECTLY........................................................................................................................26
TIPSFORUSINGPANSCORRECTLY...............................................................................................................................27
OVENCOOKING.....................................................................................................................................................28
SYMBOLS......................................................................................................................................................................29
OVENRACKS.................................................................................................................................................................29
OVENFUNCTIONSELECTOR.........................................................................................................................................29
USINGTHEOVEN...................................................................................................................................................30
OVENLIGHT..................................................................................................................................................................30
COOLINGFANS.............................................................................................................................................................30
FRONTINDICATORLIGHTS...........................................................................................................................................30
SOUNDBUZZER............................................................................................................................................................30
OVENCONVECTIONFAN..............................................................................................................................................30
4
BAKE.....................................................................................................................................................................31
PREHEATINGTHEOVEN.....................................................................................................................................31
GETTINGTHEBESTRESULTS..............................................................................................................................31
BAKEWARETYPE.................................................................................................................................................31
BAKERACKPOSITIONS............................................................................................................................... ........31
CONVECTION......................................................................................................................................................... 31
CONVECTION.......................................................................................................................................................31
CONVECTIONBAKE.............................................................................................................................................31
TURBO.................................................................................................................................................................31
RACKPOSITIONS.................................................................................................................................................32
BAKINGRECOMMENDATIONS...........................................................................................................................33
WARMING............................................................................................................................... .............................. 33
PROOFING.............................................................................................................................................................33
DEHYDRATE...........................................................................................................................................................34
BROIL/CONVECTIONBROIL..................................................................................................................................35
BROILINGANDROASTINGRECOMMENDATIONS...................................................................................................36
CAREANDMAINTENANCE.....................................................................................................................................37
SELFCLEANINGTHEOVEN.....................................................................................................................................37
MAINTAININGYOURRANGE..................................................................................................................................38
CLEANINGYOURRANGE........................................................................................................................................39
TROUBLESHOOTINGGUIDE....................................................................................................................................40
LOCATIONOFAPPLIANCETAGS............................................................................................................................. 41
IMPORTANTAPPLIANCEINFORMATION................................................................................................................42
5
WARRANTYANDSERVICE
AllBertazzoniproductscarrya2yearpartsandlabourwarranty.
ServiceonallBertazzoniproductsshallbecarriedoutbyfactorytrainedprofessionalsonly.
ForwarrantyservicepleasecontactCustomerServiceatthenumbers indicatedbelow.
CUSTOMERSERVICE
English/Spanishhotline (866)9050010
French(800)5617625
Fax(714)
4280040
Email
Mailingaddress
SERVICEPOWER
1503SouthCoastdrive
Suite320
CostaMesaCA92626
REPLACEMENTPARTS
OnlyBertazzonireplacementpartsmaybeusedinperformingserviceontheappliance.
Replacementpartsareavailablefromfactoryauthorizedpartsdistributors.
APWagner PHONE
1 888 279 2463 FAX716 856 4779
ReliableParts PHONE 206 5758818 FAX206 5750910
Coast PHONE 800 821 0244 FAX604 321 6646
6
IMPORTANTSAFETYINFORMATION
PLEASEREADANDFOLLOWTHESEIMPORTANTINSTRUCTIONSFORTHESAFETYOFYOURHOMEANDOF
THEPEOPLELIVINGINIT.
SavethisManualforlocalelectricalinspector’suse.
Readandsavetheseinstructionsforfuturereference.
Observeallgoverningcodes,ordinancesandregulations.
WARNING!
Iftheinformationinthismanualis
notfollowedexactly,afireorexplosionmayresultcausingproperty
damage,personalinjuryordeath.
Donotstoreorusegasolineorotherflammablesubstancesinthevicinityofthisoranyotherappliance.
Installationandservicemustbeperformedbyaqualifiedinstaller,serviceagencyorthegas
supplier.
InMassachusetts:Allgasproductsmustbeinstalledbya"Massachusetts"licensedplumberorgasfitter.A
"T"handletypemanualgasvalvemustbeinstalledinthegaslineconnectedtothisappliance.
WHATTODOIFYOUSMELLGAS
Donotlightanyappliance.
Donottouchanyelectricalswitch.
Donotuse anyphoneinyourbuilding.
Immediatelycallyourgassupplierfromaneighbour’sphone.Followthegassupplier’sinstructions.
Ifyoucannotreachyourgassuppliers,callthefiredepartment.
Warning!
This range can tip. Injury to persons could result.
Install anti-tip device shipped with range. See
Installation Instructions.
7
WARNING!
Readthisinstructionbookletbeforeinstallingandusingtheappliance.
Themanufacturerwillnotberesponsibleforanydamagetopropertyortopersonscausedbyincorrect
installationorimproperuseoftheappliance.
The manufacturer reserves the right to make changes to its products when considered necessary and
useful,
withoutaffectingtheessentialsafetyandoperatingcharacteristics.
Thisappliancehasbeendesignedfornonprofessional,domesticuseonly.
Donotusethisappliancetoheataroom.
Donotplaceanypotorpanontheopenovendoor.Thedoorismadeofglassanditcanbreak
ifloaded
withaweight.
Beforebeginninginstallation,pleasereadtheseinstructionscompletelyandcarefully.
Do not remove permanently affixed labels, warnings, or plates from the product. This may void the
warranty.‐Pleaseobservealllocalandnationalcodesandordinances.
Pleaseensuretherangeisproperlygrounded.
Theinstallershould
leavetheseinstructionswiththeconsumerwhoshouldretainforlocalinspector'suse
andforfuturereference.
Theplugshouldalwaysbeaccessible.
Installation must confor m with local codes or in the absence of codes, the National Fuel Gas Code
NSIZ223.1latest edition. Electrical installation must be in accordance with
the National Electrical Code,
ANIS/NFPA70‐latesteditionand/or local codes.IN CANADA:Installation must bein accordance withthe
current CAN/CGAB149.1 National Gas Installation Code or CAN/CGAB 149.2, Propane Installation Code
and/or local codes. Electrical installation must be in accordan c e with the current CSA C22.1 Canadian
ElectricalCodesPart
1and/orlocalcodes.
Installationofanygasfiredequipmentshouldbemadebyalicensedplumber.Amanualgas shutoffvalve
mustbeinstalledinthegassupplylineaheadoftheoveninthegasflowforsafetyandeaseofservice.
8
PRODUCTSPECIFICATIONS
Dimensions(insertdrawingsfront,sideandback)
Weight
Burnerpower
Naturalgas
LPgas
Auxiliary
3750BTU/h 3750BTU/h
Semirapid
6000BTU/h 6300BTU/h
Rapid
10400BTU/h 11400BTU/h
Dualburner(inner)
2730BTU/h 2900BTU/h
Dualburner(outer)
15000BTU/h 16400BTU/h
9
BEFOREINSTALLATION
This appliance shall only be installed by an
authorizedprofessional.
This appliance shall be installed in accordance
withthemanufacturer’sinstallationinstructions.
This appliance must be installed in accordance
withthenorms&standardsofthecountrywhere
it will be installed. The installation of this
appliance must conform to local
codes and
ordinances. In the absence of local codes,
InstallationsmustconformstoAmericanNational
Standards,NationalFuel GasCodeANSIZ223.1
latestedition**orB149.1.
The appliance, when installed, must be
electrically grounded in accordance with local
codes or,in the absenceof localcodes, with the
National
ElectricalCode,ANSI/NFPA70.
If local codes permit, a flexible metal appliance
connection with the new AGA or CGA certified
design, max. 5 feet (1,5 m) long, ½” I.D. is
recommended for connecting this appliance to
the gas supply line. Do not bend or damage the
flexibleconnectorwhenmovingthe
appliance.
This appliance must be used with the pressure
regulator provided. The regulator shall be
properlyinstalled inorder tobe accessiblewhen
theappliance isinstalled in itsfinallocation.The
pressureregulatormustbesetforthetypeofgas
tobeused.Thepressureregulatorhas½”
female
pipe thread. The appropriate fitting must be
determined basedon thesize ofyour gas supply
line,theflexiblemetalconnectorandtheshutoff
valve.
The appliance must be isolated from the gas
supply piping system by closing its individual
manualshutoffvalveduringanypressuretesting
ofthegas
supplypipingsystemattestpressures
equaltoorlessthan½psi(3.5kPa).
All openingandholes in the wall andfloor, back
and under the appliance shall be sealed before
installationoftheappliance.
Amanualvalveshallbeinstalledin anaccessible
location inthe gas
line external to the appliance
for thepurpose of turningon orshutting off gas
totheappliance
WARNING!
Donotuseaerosolspraysinthevicinityofthis
appliancewhileitisinoperation
ROOM VENTILATION: An exhaust fan may be
used with the appliance; in each case it
shall be
installed in conformity with the appropriate
national and local standards. Exhaust hood
operationmay affectotherventedappliances; in
each case it shall be installed in conformity with
theappropriatenationalandlocalstandards.
TYPEOFGAS
Thisapplianceisshippedfromthefactoryforuse
with natural
gas. For use with propane LP gas
please follow the conversion procedure
described on pg. 17. A step by step conversion
procedureisalsoincludedwitheachsetofLPgas
nozzles.
GASPRESSURE
Themaximuminletgassupplypressureincoming
to the gas appliance pressure regulator is 20’’
water
column(5kPa).
The minimu m gas supply pressure for checking
theregulatorsettingshallbeatleast1“w.c.(249
Pa)abovetheinletspecifiedmanifold pressureto
the appliance (this operating pressure is 4” w.c.
(1.00kPa)forNaturalGasand11” w.c.(2.75kPa
forLPGas).
10
INSTALLINGTHELEGS
Bertazzonirangesmustbeusedonlywiththe
legsproperlyinstalled.
Fourheightadjustablelegsareshippedwiththe
rangeinthepolystyrenecontainersituatedover
theappliance.
Before installing the legs, position the appliance
nearitsfinallocation as the legsarenotsuitable
formovingtheapplianceoverlong
distances.
After unpacking the range, raise it enough to
insert the legs in the appropriate receptacles
situated on the lower part of the appliance.
Lowertherangegently tokeepanyunduestrain
fromlegsandmountinghardware.Ifpossibleuse
apalletorliftjackinsteadoftiltingthe
unit.
Adjust leg height to the desiredlevel bytwisting
the inside portion of the leg assembly until the
properheightis reached.Check witha level that
thecooktopisperfectlylevel.
INSTALLINGTHEWORKTOP
FRONTGUARD
Toincreasetheclearancebetweenthefrontedge
of the worktop and the burners it is possible to
install the worktop front guard shipped with the
appliance.
Toinstallthefrontguard,holditwiththepointed
edges looking up. Align the edges of the front
guard with the appropriate receptacles
in the
bottomoftheworktopand press firmly untilthe
frontguardissecurelyattachedtotheworktop.
ATTENTION: once installed the front guard may
only be removed by disassembling the worktop.
Attempting to remove the front guard without
disassembling the worktop will result in
permanentdamagetothe
worktop.
11
INSTALLINGTHEBACKGUARD
The back guard must be installed prior to
operation of the appliance for appropriate
ventilationoftheovencompartment.
Thesuppliedbackguardisa2partassembly.The
box also contains a set of metal screws for
securingthebackguardtotheworktop.
Disassemble the back guard and position the
frontpart on the worktop. Alignthe screwholes
with the corresponding holes at the back of the
worktop.
If the holes are not aligned, partially loosen the
brackets at the back of the worktop as shown
below.

Installthefrontpartofthebackguardby
tighteningthe2centralscrewsfromthetopand
2lateralscrewsfromthebottom.

12
INSTALLINGTHEANTITIPStabilityDEVICE
Theantitipbracketshippedwiththerangemust
beproperly securedto the rearwallas shownin
thepicturebelow.
Theheightofthebracketfromthefloormustbe
determined after the range legs have been
adjusted to the desired height and
afterthe
rangehasbeenlevelled.
Measure the distance from the floor to the
bottom of the antitip bracket receptacle on the
backoftheappliance.
Position the two antitip brackets on the wall at
the desired height plus 1/8" (0.32 cm). The
bracketsmustbeplaced at
2”5/16(6,0cm)from
the side of the range. The distance between the
twobracketis43”1/4(109,8cm).
Secure thebrackets to thewall with appropriate
hardware.
Slidetherangeagainstthewalluntilthebrackets
are fully inserted into their receptacles on the
backoftherange.
INSTALLATIONREQUIREMENTS
ELECTRICAL
A properly grounded and horizontallymounted
electrical receptacle Type NEMA 1450R should
beinstallednohigherthan3"(7.6cm)abovethe
floor,nolessthan2”(5cm)andnomorethan8”
(20,3 cm) from the left side (facing product);
refer to ELE CTRICAL CONNECTION section pag.
13.
Checkalllocalcoderequirements.
GAS
Anagencyapproved,properlysizedmanualshut
off valve should be installed no higher than 3"
(7.6 cm) above the floor and no less than 2” (5
cm)andnomorethan8”(20.3cm)fromtheright
side(facingproduct).
To connect gas
between shutoff valve and
regulator, use agency approved, properly sized
flexible or rigid pipe. Check all local code
requirements.
13
INSTALLATIONADJACENTTOKITCHEN
CABINETS
This range may be installed directly adjacent to
existingcountertophighcabinets(36"or91.5cm
fromthefloor).
For the best look, the worktop should be level
with the cabinet countertop. This can be
accomplished by raising the unit using the
adjustmentspindlesonthelegs.
ATTENTION: the range CANNOT
be installed
directly adjacent to kitchen walls, tall cabinets,
tall appliances, or other vertical surfaces above
36" (91.4 cm)high. The minimum side clearance
insuchcasesis6"(15.2cm).
Wallcabinetswithminimumsideclearancemust
be installed 18" (45.7 cm) above the countertop
withcountertopheightbetween
35½”(90.2cm)
and37¼”(94.6cm).Themaximumdepthofwall
cabinetsabovetherangeshallbe13"(33.0cm)

EXHAUSTHOODINSTALLATION
ThisrangewillbestperformwhenusedwithPRO
lineBertazzoniexhausthoods.Thesehoodshave
been designed to work in conjunction with the
Bertazzoni range and have the same finish for a
perfectlook.
For maximum performance, the height of the
bottomofthe hood fromtheworktop should be
between 25 1/2" (65 cm) and 31 1/2" (80 cm).
This would typically result in the bottom of the
hoodbeing 611/2"(156.2 cm)to67 1/2"(171.5
cm) above the floor. These measurements
provide for safe and efficient operation of the
hood.
Before installation of the exhaust hood,
consult
local or regional building and installation codes
foradditionalspecificclearancerequirements.
Refer to the range hood installation instructions
provided by the manufacturer for additional
information.
A 48” (122 cm)
B 36” (91,5 cm)
C 13” (33,0 cm)
D 18” (45,7 cm)
E 35”1/2(90,2 cm) / 37” ¼ (94,6 cm)
F 6” (15,2 cm)
14
ELECTRICALCONNECTION
The appliance shall be connected toa single
phase electric line rated at 120/208Vac or
120/240Vacand60Hzfrequency.
Electricpowerrating:
‐120/208Vac:6700Wattor32Amax.
‐120/240Vac:8500Wattor37Amax.
Heatingelements(240V)power rating:
LEFTOVEN:
‐Ovenbakeelement=2100Watt
‐Ovencircularelement=3300Watt
‐Ovenbroilelement=3400Watt
RIGHTOVEN:
‐Upper+broilelement=900+1100Watt
‐Bottomelement=900Watt
WORKTOPELE.GRIDDLEELEMENT=1100Watt
Installa suitableelectricpowersupplyreceptacle
connection type NEMA 1450Rable to support a
load ofat least40 A(per line)according to local
coderequirements.Forfourorthreewirespower
supplyconnectionsystemseediagrambelow.
FOUR-WIRE CONN.RECEPTACLE NEMA 14-50R
THREE-WIRE CONN.RECEPTACLE NEMA 14-50R
Check your local code for which of the options
belowshould be usedin grounding the
receptaclepowersupplyconnections.
OPTION 1 – FOUR Wires connection:
‐ Connect the L1 receptacle terminal to the
incoming BLACK electrical supply wire (L1hot
wire)
‐ Connect the L2 receptacle terminal to the
incoming RED electrical supply wire (L2hot
wire)
‐ Connect the NEUTRAL receptacle terminal to
the incoming NEUTRAL (WHITE) electrical
supplywire
‐ Connect the GROUND receptacle terminal to
the incoming GROUND (GREEN) electrical
supplywire
OPTION 2 - THREE-Wires connection:
‐ Connect the L1 receptacle terminal to the
incoming BLACK electrical supply wire (L1hot
wire)
‐ Connect the L2 receptacle terminal to the
incoming RED electrical supply wire (L2hot
wire)
‐ Connect the NEUTRAL with the GROUND
receptacle terminal to the incoming NEUTRAL
(WHITE)electricalsupplywire
DO NOT USE EXTENSION CORDS WITH THIS
APPLIANCE AS IT MAY RESULT IN FIRE,
ELECTRIC SHOCK OR OTHER type of
PERSONAL INJURY.
The appliance isequipped at the factory with an
electric supply cord set 4 wires type with ring
terminals (L1, L2, N, Ground) suitable for range
use UL/CSA listed type SRDT/DRT 2x6AWG (L1,
L2)+2x8AWG (N, G) rated 300V, 40 or 50A with
fused plug type NEMA 1450P; cable length 1,5
m.;incasethesupplycordsetmustbereplaced,
it shall be replaced with anidentical set having
the same technical specs and followingcarefully
theinstructionsanddiagramsbelow:
1) Disconnect appliance from electrical power
supplyreceptacle
2) Slideouttheappliancefrominstallationplace
toaccessto
backenclosurepanel
3) Remove back enclosure panel by removing
the6screwsasshownbelow
15
4) Loosestrainreliefbyunscrewingthetwo
strainrelief'sscrewsasindiagram.
16
5) Remove damaged supply cord set by taking
off the 4 electrical connection screws (block
L1,N,L2andGroundscrew,seediagram)
6) Insert the new supply cord set in the strain
relief and lock it with two strain relief's
screwsinsuitableposition.
7) Fixwell the ringterminals
G, L1, N,L2ofthe
new supply cord set asshown in diagram
withits4screws
8) Reinstall the back enclosure panel with 6
screws
9) Slide the appliance back into its proper
location
10) Reconnect the appl iance to the electrical
power.
ELECTRICALGROUNDING
Thisapplianceisequippedwitha fourprongplug
for your protection against shock hazard and
should be plugged dir ectly into a properly
grounded recepta cle. Do not cut or remove the
groundingprongfromthisplug.
WARNING!
ELECTRICALSHOCKHAZARD
Disconnectelectricalpowe ratthecircuit
breakerbox
orfuseboxbeforeinstallingthe
appliance.
Provideappropriategroundfortheappliance.
Usecopperconductorsonly.
Failuretofollowtheseinstructionscouldresult
inseriousinjuryordeath
CAUTION
Labelallwirespriortodisconnectingwhen
servicingcontrols.Wiringerrorscancause
improperanddangerousoperation.
Verifyproperoperation
afterservicing
LOCATIONOFAPPLIANCEPLATES
Thedataratingplateshowsthemodelandserial
number of your range. It is located under the
front edge of the range cooktop, and is visible
whentheovendoorisopen(seeillustration)
A=Ratingplate(s)locatedunderfrontedgeof
cooktop
B=Wiring/schematicdiagramplacedon
backsidepanelandoninstallationbooklet
17
WIRINGDIAGRAM
LEFT OVEN + GAS TOP IGNITION
18
RIGHT OVEN + GRIDDLE
19
GASCONNECTION
All gas connections must comply with national
and local codes. The gas supply line (service)
must be the same size or greater than the inlet
lineof theappliance. This range usesa 1/2"NPT
inlet (see drawing below for details of gas
connection). On all pipe joints use appropriate
sealant
resistanttogas.
This range can be used with Natural or
LP/Propane gas. The range is shipped from the
factoryforusewithnaturalgas.
For LP/propane household installation, the
appliance mustbe converted bythe dealer, bya
factorytrained professional or by a qualified
licensedplumberorgas
servicecompany.
Gasconversionisimportantforsafeandeffective
useoftheappliance.Itistheresponsibility ofthe
dealerandtheowneroftherangetope rformthe
appropriate gas conversion following the
directionsofthemanufacturer.
THEGASCONVERSIONPROCEDUREIS
DESCRIBEDINTHISMANUALANDINTHE
PACKAGECONTAININGTHECONVERSION
NOZZLESSHIPPEDWITHEVERYRANGE.
Pleaseprovidetheservicepersonwiththis
manualbeforeworkisstartedontherange.
WARNING!
DONOTUSEANOPENFLAMEWHENCHECKING
FORLEAKS!
Leak testing of the appliance shall be conducted
according to the manufacturer's instructions.
Before placing
the oven into operation, always
check for leaks with soapy water solution or
otheracceptablemethod.
MANUALSHUTOFFVALVE
THISVALVEISNOTSHIPPEDWITHTHE
APPLIANCEANDMUSTBESUPPLIEDBYTHE
INSTALLER.
The manual shutoff valve must be installed in
the gasservice linebetween the
gashookup on
the wall and the appliance inlet, in a position
whereitcanbereachedquicklyintheeventofan
emergency.
In Massachusetts: A 'T' handle type manual gas
valve must be installed in the gas supply line to
thisappliance.
FLEXIBLECONNECTIONS
In case of
installation with flexible couplings
and/or quickdisconnect fittings, the installer
must use a heavyduty, AGA designcertified
commercial flexible connector of at least 1/2"
(1.3 cm) ID NPT (with suitable strain reliefs) in
compliance with ANSI Z21.41 and Z21.69
standards.
In Massachusetts: The unit must be installed
witha
36"(3foot)longflexiblegasconnector.
InCanada:useCAN16.1088metalconnectors
forgasappliancesandCAN16.9M79quick
disconnectdeviceforusewithgasfuel.
PRESSURETESTPOINTSTOPPERVALVE
To avoid gas leaks, the pressure testpoint
stoppervalveandgaske tsupplied
withtherange
mustbeinstalledonthegasfittingatthebackof
therangeaccordingtothediagrambelow.

20
PRESSUREREGULATOR
Since service pressure may fluctuate with local
demand, every gas cooking appliance must be
equipped with a pressure regulator on the
incoming service line for safe and efficient
operation.
The pressure regulator shipped with the
appliance has two female threads ½” NPT. The
regulatorshallbeinstalledproperly in
ordertobe
accessible when the appliance is installed in its
finalposition.
Manifoldpressureshouldbecheckedwitha
manometerandcomplywiththevaluesindicated
below:
Naturalgas4.0"W.c.P.
LP/Propane11.0"W.C.P.
Incominglinepressureupstreamfromthe
regulatormustbe1"W.c.P.higherthanthe
manifoldpressureinordertocheckthe
regulator.
Theregulatorusedon
thisrangecanwithstanda
maximuminputpressureof1/2PSI(14.0"W.c.P.)
Ifthelinepressureexceedsthatamount,astep
downregulatorisrequired.
The appliance, its individual shutoff valve, and
the pressure regulator must be disconnected
from the gas line during any pressure testing of
that system
at pressures in excess of 1/2 psig
(3.45kPa).
The individual manual shutoff valve must be in
the OFF position during any pressure testing of
the gas supply piping system at test pressures
equaltoorlessthan½psig(3.45kPa).
GASCONVERSION
WARNING!
Beforecarryingoutthisoperation,disconnect
theappliancefromgasandelectricity.
Gasconversionshallbeconductedbyafactory
trainedprofessional.
Callthecustomerservicehotlinetoidentifya
factorytrainedprofessionalnearyourhome.
The gas conversion procedure for this range
includes6steps:
1. Pressureregulator
2.
Surfaceburners
3. Adjustmentofminimumsetting
The conversion is not completed if all 6 steps
havenotbeenconcludedproperly.
Beforeperformingthegasconversion,locatethe
package containing the replacement nozzle
shipped with every range. IMPORTANT: Each
nozzle hasa number indicating its flowdiameter
printedonthe
body.Consultthetableonpage20
formatchingnozzlestoburners.
Savethenozzlesremovedfromtherangefor
futureuse.
STEP1:PRESSUREREGULATOR
Thepressureregulatorsuppliedwiththe
applianceisaconvertibletypepressure regulator
forusewithNaturalGasatanominaloutlet
pressureof
4”w.c.orLPgasatanominaloutlet
pressureof11”w.c.anditisprearrangedfrom
thefactorytooperatewithoneofthese
gas/pressureasindicatedinthelabelsaffixedon
theappliance,packageandInstructionbooklet.
Toconverttheregulatorforusewithotherliquid
propaneLPgas:
1. Unscrewbyhandtheuppercapofthe
regulator,removethewhiteplastic
attachmentfromthecap,reverseits
directionandscrewitagainfirmlyagainstthe
cap.Thewhiteplasticattachmenthasarrows
indicatingthepositionfornaturalgas(NAT)
andLPgas(LP).
2. Screw
byhandthemetalcapintheoriginal
positionontheregulator.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43

Bertazzoni PRO486GDFSX Owner's manual

Category
Kitchen & houseware accessories
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI