Hampton Bay 14926 Installation guide

Category
Household fans
Type
Installation guide
Northport
52
in Ceiling Fan
Owner’s Manual
Northport
Ventilador de Techo de 1,32
m
Manual del Propietario
178 047
Northport by Hampton Bay
®
52” Northport
Ceiling Fan by Hampton Bay
Date Purchased
Store Purchased
UL Model No.
Serial No.
Vendor No.
UPC
Thank you for purchasing our ceiling fan. This product has been
manufactured with the highest standards of safety and quality.
Table of Contents
Safety Rules . . . . . . . . . . . . . . . . . . . . 1
Unpacking Your Fan . . . . . . . . . . . . . . 2
Installing Your Fan . . . . . . . . . . . . . . . 3
Installing the Light Kit . . . . . . . . . . . . 9
Operating Your Fan . . . . . . . . . . . . . 10
Care or Your Fan . . . . . . . . . . . . . . 11
Troubleshooting . . . . . . . . . . . . . . . 11
Specifications . . . . . . . . . . . . . . . . . . 12
Warranty Information . . . . . . . . . . . . 13
718212149263
219054
178-047
Safety Rules - Read and Save These Instructions
1
To reduce the risk of electric shock, insure electricity has been turned off
at the circuit breaker or fuse box before beginning.
All wiring must be in accordance with the National Electrical Code
“ANSI/NFPA 70-1999” and local electrical codes. Electrical installation
should be performed by a qualified licensed electrician.
WARNING: To reduce the risk of electrical shock or fire, do not use this
fan with any solid-state fan speed control device. It will permanently
damage the electronic circuitry.
CAUTION: To reduce the risk of personal injury, use only the screws
provided with the outlet box.
The outlet box and support structure must be securely mounted and
capable of reliably supporting a minimum of 35 pounds. Use only UL
Listed outlet boxes marked “FOR FAN SUPPORT”.
The fan must be mounted with a minimum of 7 feet clearance from the
trailing edge of the blades to the floor.
Avoid placing objects in path of the blades.
To avoid personal injury or damage to the fan and other items, be
cautious when working around or cleaning the fan.
Do not use water or detergents when cleaning the fan or fan blades. A dry
dust cloth or lightly dampened cloth will be suitable for most cleaning.
After making electrical connections, spliced conductors should be turned
upward and pushed carefully up into outlet box. The wires should be
spread apart with the grounded conductor and the equipment-grounding
conductor on one side of the outlet box and ungrounded conductor on the
other side of the outlet box.
All set screws must be checked and retightened where necessary before
installation.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
WARNING
TO REDUCE THE RISK OF PERSONALL INJURY, DO NOT BEND THE
BLADE HOLDERS (ALSO REFERRED TO AS FLANGES), WHEN
INSTALLING THE HOLDERS, BALANCING THE BLADES OR
CLEANING THE FAN. DO NOT INSERT FOREIGN OBJECTS IN–
BETWEEN ROTATING FAN BLADES.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL
INJURY, MOUNT FAN TO OUTLET BOX MARKED ACCEPTABLE
FOR FAN SUPPORT WITH THE SCREWS PROVIDED WITH THE
OUTLET BOX.
ATTENTION
FAN INCLUDES A 190W LIMITER TO COMPLY WITH THE
DEPARTMENT OF ENERGY 2009 REGULATION. LAMPING THIS
PRODUCT OVER 190W WILL CAUSE THIS FAN TO NOT LIGHT.
PLEASE USE BULBS WITH A TOTAL WATTAGE UNDER THE 190W
REGULATION.
2
Unpacking Your Fan
Unpack your fan and check the contents. You should have the following items:
AB
C
Set of blades (4)
Canopy assembly
Standard Ball/downrod assembly
Minimum-length downrod (for close to
the ceiling installation only)
Coupling cover
1.
2.
3a.
3b.
4.
Fan motor assembly
Light kit mounting plate
Light kit assembly
Glass shade
75 Watt halogen bulb
Pull chains and fobs (2)
5.
6.
7.
8.
9.
10.
Electrical Hardware
(3 Plastic Wire Nuts)
Blade Attachment Hardware
3/16"×12.3mm Screws (13PCs.)
Fiber Washers (13PCs.)
Balancing Kit
A.
B.
C.
WARNING
DO NOT INSTALL OR USE FAN IF ANY
PART IS DAMAGED OR MISSING.
CALL TOLL FREE 1-800-527-0998.
1
2
3a
3b
4
5
6
7
8
9
10
3
Installing Your Fan
Figures 1~3 are examples of different ways to
mount the outlet box.
If there isn't an existing UL listed mounting box,
then read the following instructions. Disconnect
the power by removing fuses or turning off circuit
breakers.
Secure the outlet box directly to the building
structure. Use appropriate fasteners and building
materials. The outlet box and its support must be
able to fully support the moving weight of the fan
(at least 35 lbs). Do not use plastic outlet boxes.
Tools Required
Mounting Options
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK OR PERSONAL INJURY, MOUNT FAN
ONLY TO AN OULET BOX MARKED ACCEPT-
ABLE FOR FAN SUPPORT AND USE THE
MOUNTING SCREWS PROVIDED WITH THE
OULET BOX. OUTLET BOX COMMONLY USED
FOR THE SUPPORT OF LIGHTING FIXTURE
MAY NOT BE ACCEPTABLE FOR FAN SUPPORT
AND MAY NEED TO BE REPLACED. CONSULT A
QUALIFIED ELECTRICIAN IF IN DOUBT.
Outlet Box
Outlet Box
Outlet Box
Figure 2
Figure 1
Note: You may need a longer downrod to
maintain proper blade clearance when installing
on a steep, sloped ceiling. The maximum angle
allowable is 18
°
. If the canopy touches downrod,
remove the decorative canopy bottom cover and
turn the canopy 180
°
before attaching the canopy
to the mounting plate.
To hang your fan where there is an existing fixture
but no ceiling joist, you may need an installation
hanger bar as shown in Figure 4 (available at any
Home Depot store).
Ceiling
Mounting
Plate
Provide Strong
Support
Recessed
Outlet Box
Figure 3
Figure 4
Phillips screwdriver, straight slot screwdriver, step
ladder and wire cutters.
4
REMEMBER to turn off the power. Follow the
steps below to hang your fan properly.
Remove the canopy cover from the canopy by
turning the cover counter clockwise. (Figure 5)
Remove the hanger bracket from the canopy by
removing the non-slotted screws from the
bottom of the hanger bracket and loosening the
other one a half turn from the screw head.
Next, turn the canopy counter clockwise to
removing the hanger bracket from the canopy.
(Figure 5)
Remove the clevis pin, cotter pin and set
screws from the top of the motor assembly.
(Figure 6)
Remove hanger ball from downrod assembly
by loosening set screw, removing the cross pin,
and sliding ball off rod. (Figure 7)
Carefully feed motor wires up through the
downrod. Thread the rod into the coupling.
Next line up holes and replace cotter pin and
clevis pin. Tighten set screws. (Figure 8)
Slip coupling cover, canopy cover and canopy
onto downrod. Carefully reinstall hanger ball
onto rod being sure that cross pin is in correct
position, set screws are tighten and wires are not
twisted. (Figure 9)
1.
2.
3.
4.
5.
6.
WARNING
FAILURE TO PROPERLY INSTALL COTTER
PIN AS NOTED IN STEP 5 COULD RESULT IN
FAN LOOSENING AND POSSIBLY FALLING.
Hanging the Fan
Figure 6
Set Screws
Clevis Pin
Cotter Pin
Hanger
Bracket
Ceiling Canopy
Canopy Bottom
Cover
Figure 5
Figure 8
Downrod
Motor Wires
Figure 7
Cross Pin
Hanger Ball
Downrod
5
WARNING
THE TAB IN THE RING MUST REST IN THE
GROOVE OF THE HANGER BALL AS FIGURE 11.
FAILURE TO PROPERLY SEAT THE TAB IN THE
GROOVE COULD CAUSE DAMAGE TO WIRING.
Installing Fan to the
Electrical Box
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK OR OTHER PERSONAL INJURY.
MOUNT FAN ONLY TO AN OUTLET BOX OR
SUPPORTING SYSTEM MARKED ACCEPTABLE
FOR FAN SUPPORT AND USE THE MOUNTING
SCREWS PROVIDED WITH THE OUTLET BOX.
Pass the 120-volt supply wires through the
center hole in the hanger bracket as shown in
Figure 10.
Install the hanger bracket on the outlet box
with the screws and washers provided with
your outlet box. (Figure 10)
Security tighten the two mounting screws.
Carefully lift the fan assembly up to the hanger
bracket and seat the hanger ball in the bracket
socket. Make sure the tab on the hanger bracket
socket is properly seated in the groove in the
hanger ball. (Figure 11) This will help to
balance the ceiling fan.
1.
2.
3.
4.
Figure 10
UL Listed Outlet Box
Hanger Bracket
120V
Wires
Mounting
Screws
(Supplied
with Electrical Box)
Tab
Figure 11
Groove
Tab
Figure 9
Pin in Locked
Positioon
Motor Wires
Downrod
Ceiling Canopy
Canopy Bottom
Cover
Motor Collar
Coupling Cover
Tighten Screw Firmly
Cotter Pin
Set Screw
Cross Pin
Clevis Pin
Hanger Ball
6
blue wire will be on the other side, and push
carefully up into the outlet box.
Connect the ground conductor of the 120V
supply (this may be a bare wire or a wire with
green colored insulation) to the green ground
lead(s) of the fan (Figure 12).
Connect the fan motor white wire to the supply
white (neutral) wire using a wire nut. (Figure
12)
Connect the fan motor black wire to the supply
black (hot) wire using a wire nut (Figure 12).
Connect the blue wire for light kit to the black
household supply wire.
Turn wire nut connections upward, spreading
them apart so the green (ground) will be on one
side of the outlet box and the white, black and
1.
2.
3.
4.
5.
Making the Electrical
Connections
REMEMBER to disconnect the power.
If you feel you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
Follow the steps below to connect the fan to your
household wiring. Use the wire nuts supplied with
your fan. Secure the wire nuts with electrical tape.
Make sure there are no loose strands or
connections.
WARNING
CHECK TO SEE THAT ALL CONNECTIONS ARE
TIGHT, INCLUDING GROUND, AND THAT NO
BARE WIRE IS VISIBLE AT THE WIRE NUTS.
EXCEPT FOR THE GROUND WIRE.
ELECTRICAL DIAGRAMS ARE FOR
REFERENCE ONLY. OPTIONAL USE OF ANY
LIGHT KIT SHALL BE UL LISTED AND
MARKED SUITABLE FOR USE WITH THIS FAN.
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC
SHOCK. DO NOT USE THIS FAN WITH ANY
SOLID-STATE SPEED CONTROL DEVICE.
WARNING
SUPPLY CIRCUIT
Figure 12
BLACK
WHITE
BLACK
WHITE
BLUE
GREEN
Outlet Box
Ground
Conductor
Green
Ground
Lead
Ground to
Downrod
7
Figure 13
Outlet Box
Hanger
Bracket
Screw
Screw
Canopy
Canopy
Bottom Cover
Finishing the Fan
Installation
Tuck connections neatly into ceiling outlet
box.
Slide the canopy up to hanger bracket and
place the key hole on the canopy over the
screw on the hanger bracket, turn canopy until
it locks in place at the narrow section of the key
holes. (Fig. 13)
Align the circular hole on canopy with the
remaining hole on the hanger bracket, secure
by tightening the two set screws. Note: Adjust
the canopy screws as necessary until the
canopy and canopy cover are snug. (Fig. 13)
1.
2.
3.
Fiber Washers
Screws
BladesBottom Band
Figure 14
Insert the blade through the slots in the bottom
band. (Fig. 14)
Align the holes from the blade to the holes in
the center band and secure in place with screws
and fiber washers provided.
Repeat process with other blades.
Attaching the Fan Blades
1.
2.
3.
WARNING
MAKE SURE THE TAB ON THE HANGING
BRACKET PROPERLY SITS IN THE GROOVE IN
THE HANGER BALL BEFORE ATTACHING THE
CANOPY TO THE BRACKET BY TURNING THE
HOUSING UNTIL IT DROPS INTO PLACE.
WARNING
TO REDUCE THE RISK OF PERSONAL INJURY,
DO NOT BEND THE BLADE HOLDERS WHILE
INSTALLING, BALANCING THE BLADES, OR
CLEANING THE FAN. DO NO INSERT FOREIGN
OBJECTS BETWEEN ROTATING FAN BLADES.
8
Blade Balancing
Check that all blade and blade holder screws
are secure.
Most fan wobble problems are caused when
blade levels are unequal. Check this level by
selecting a point on the ceiling above the tip of
one of the blades. Measure from a point on the
center of each blade to the point on the ceiling.
Measure this distance as shown in Figure 15.
Rotate the fan until the next blade is positioned
for measurement. Repeat for each blade.
Measurements deviation should be within 1/8˝.
Run the fan for 10 Minutes.
Use the enclosed Blade Balancing Kit if the
blade wobble is still noticeable.
1.
2.
3.
The following procedure should correct most fan
wobble. Check after each step.
Figure 15
Touching Ceiling
Attaching the Light Kit
Mounting Plate
Remove the 1 of 3 screws from the mounting
ring and loosen the other 2 screws. (Do not
remove)
Place the key holes on the light kit mounting
plate over the 2 screws previously loosened
from the mounting ring, turn the light kit
mounting plate until it locks in place at the
narrow section of the key holes. Secure by
tightening the 2 screws previously loosened
and the one previously removed (Fig. 16).
1.
2.
Light Kit Mounting
Plate
Mounting Ring
Screws
Figure 16
9
Figure 18
Bulbs
Glass
Shade
Light Kit
Assembly
Remove the 1 of 3 screws from the light kit
mounting plate and loosen the other 2 screws.
(Do not remove)
While holding the light kit assembly under
your fan, snap the wire connection plugs
together. (Fig. 17)
Carefully push all wires back into the light kit
mounting plate. Place the key holes on the
light kit assembly over the 2 screws previously
loosened from the mounting plate, turn the
light kit assembly until it locks in place at the
narrow section of the key holes. Secure by
tightening the 2 screws previously loosened
and the one previously removed. (Fig. 17)
1.
2.
3.
Install 1 x 75 watts halogen bulb (included)
into the light sockets.
Raise glass shade up against light kit and
secure it to fan by twisting glass clockwise
until snug. Do not overtighten. (Fig. 18)
Restore power and your light kit is ready for
operation.
4.
5.
6.
CAUTION
BEFORE STARTING INSTALLATION, DISCON-
NECT THE POWER BY TURNING OFF THE
CIRCUIT BREAKER OR REMOVING THE FUSE
AT FUSE BOX. TURNING POWER OFF USING
THE FAN SWITCH IS NOT SUFFICIENT TO
PREVENT ELECTRIC SHOCK.
Screws
Light Kit
Assembly
Wire Connection
Plugs
Installing the Light Kit
Light Kit
Mounting Plate
Figure 17
NOTE
LIGHT BULBS HAVE NO WARRANTY; CAN BE
PURCHASED AT ANY HOME DEPOT STORE.
ATTENTION
FAN INCLUDES A 190W LIMITER TO COMPLY
WITH THE DEPARTMENT OF ENERGY 2009
REGULATION. LAMPING THIS PRODUCT OVER
190W WILL CAUSE THIS FAN TO NOT LIGHT.
PLEASE USE BULBS WITH A TOTAL WATTAGE
UNDER THE 190W REGULATION.
10
Operating Your Fan
Turn on the power and check the operation of your
fan. There are two pull chains available in your
fan:
1. 3-speed pull chain- it controls the fan speed as
follows: 1 pull- High, 2 pulls- Medium, 3 pulls-
Low, and 4 pulls- Off.
Speed settings for warm or cool weather depend
on factors such as the room size, ceiling height,
number of fans, and so on.
2. Light kit pull chain- it controls the light kit in
"ON" or "OFF".
The Reverse switch is located on the light kit
assembly. (Figure 19) Slide the switch to the Left
for warm weather operation. Slide the switch to
the Right for cool weather operation.
NOTE
WAIT FOR FAN TO STOP BEFORE REVERSING
THE DIRECTION OF THE BLADE ROTATION.
Figure 20Figure 19
Figure 21
Warm weather - (Counter-Clockwise direction)
A downward air flow creates a cooling effect as
shown in Figure 20. This allows you to set your air
conditioner on a higher setting without affecting
your comfort.
Cool weather - (Clockwise direction) An upward
air flow moves warm air off the ceiling are as
shown in Figure 21. This allows you to set your
heating unit on a lower setting without affecting
your comfort.
Reverse
Switch
11
WARNING
MAKE SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX
BEFORE YOU ATTEMPY ANY REPAIRS. REFER TO THE SECTION,
“MAKING ELECTRICAL CONNECTIONS”.
Because of the fan's natural movement, some
connections may become loose. Check the
support connections, brackets, and blade
attachments twice a year. Make sure they are
secure. (It is not necessary to remove fan from
ceiling.)
Clean your fan periodically to help maintain its
new appearance over the years. Use only a soft
brush or lint-free cloth to avoid scratching the
finish. The plating is sealed with a lacquer to
minimize discoloration or tarnishing. Do not
use water when cleaning. This could damage
the motor, or the wood, or possibly cause an
electrical shock.
You can apply a light coat of furniture polish to
the wood blades for additional protection and
enhanced beauty. Cover small scratches with a
light application of shoe polish.
There is no need to oil your fan. The motor has
permanently lubricated sealed ball bearings.
1.
2.
3.
4.
Here are some suggestions to help you maintain
your fan.
Check main and branch circuit fuses or breakers.
Check line wire connections to the fan and switch wire connections in
the switch housing.
Make sure all motor housing screws are snug.
Make sure the screws that attach the fan blade bracket to the motor hub
is tight.
Make sure wire nut connections are not rattling against each other or
the interior wall of the switch housing.
Allow a 24-hour "breaking-in" period. Most noises associated with a
new fan disappear during this time.
If using ceiling fan light kit, make sure the screws securing the
glassware are tight. Check that the light bulb is also secure.
Make sure there is a short distance from the ceiling to the canopy. It
should not touch the ceiling.
Make sure your ceiling box is secure and rubber isolator pads are used
between mounting bracket and outlet box.
This unit is equipped with a wattage limiting device. Lamping in excess
of 190 watts will disable your ceiling fan's light kit. To reset your light
kit you must turn the power off and relamp, keeping the wattage under
190 watts. Restore power to your ceiling fan and continue normal
operation.
1.
2.
1.
2.
3.
4.
5.
6.
7.
1.
Fan will not start
Fan sounds noisy
Lights shut off and
will not come back
on.
Care of Your Fan Troubleshooting
PROBLEM SOLUTION
12
Specifications
FAN SIZE SPEED VOLTS AMPS WATTS RPM CFM N.W. G.W. C.F.
52” 120
7.13 kgs
(15.69 lbs)
8.00 kgs
(17.60 lbs)
1.45’
LOW
MED.
HIGH
0.18
0.30
0.39
10
27.5
46
70
130
167
1777.27
3383.09
4740.71
These are approximate measures. They do not include Amps and Wattage used by the light kit.
Distributed by
Your Other Warehouse, LLC
12100 Little Cayman Dr.
Baton Rouge, LA 70809
13
The Hampton Bay warrants the fan motor to be free from defects in workmanship and material present at time
of shipment from the factory for a period of lifetime after the date of purchase by the original purchaser.
Hampton Bay also warrants that all other fan parts, excluding any glass or acrylic blades, to be free from
defects in workmanship and material at the time of shipment from the factory for a period of one year after the
date of purchase by the original purchaser. We agree to correct such defects without charge or at our option
replace with a comparable or superior model if the product is returned to Hampton Bay. To obtain warranty
service, you must present a copy of the receipt as proof of purchase. All costs of removing and reinstalling the
product are your responsibility. Damage to any part such as by accident or misuse or improper installation or
by affixing any accessories, is not covered by this warranty. Because of varying climatic conditions this
warranty does not cover any changes in brass finish, including rusting, pitting, corroding, tarnishing or peeling.
Brass finishes of this type give their longest useful life when protected from varying weather conditions. A
certain amount of “wobble” is normal and should not be considered a defect. Servicing performed by
unauthorized persons shall render the warranty invalid. There is no other express warranty. Hampton Bay
hereby disclaims any and all warranties, including but not limited to. Those of merchantability and fitness for
a particular purpose to the extent permitted by law. The duration of any implied warranty which cannot be
disclaimed is limited to the time period as specified in the express warranty. Some states do not allow
limitation on how long an implied warranty lasts, so the above limitation may not apply to you. The retailer
shall not be liable for incidental, consequential, or special damages arising out of or in connection with product
use or performance except as may otherwise be accorded by law. Some states do not allow the exclusion of
incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty
gives specific legal rights, and you may also have other rights which vary from state to state. This warranty
supersedes all prior warranties. Shipping costs for any return of product as part of a claim on the warranty must
be paid by the customer.
Lifetime Limited Warranty
(lifetime warranty on motor)
You must present a copy of the original
purchase receipt to obtain warranty
service.
For any additional information on your
Hampton Bay Ceiling Fan, please write to:
THE HAMPTON BAY FAN &
LIGHTING CO.
P. O. Box 395
Norco, CA 92860
Attach receipt here for easy
location
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Hampton Bay 14926 Installation guide

Category
Household fans
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI