The Eden SOLO 3000 is a biometric reader with RS485 output that can store up to 3000 fingerprint templates. It is compatible with SENATORFX.NET software version 1.1.6.0 or later and SENATORFX software version 5.0.11 or later. The SOLO 3000 can be connected to C1P2FX control units version 2.4 or later, C4PLUSFX control units version 4.0 or later, and GENIUS control units version 1.0 or later.

The SOLO 3000 has a maximum power consumption of 300mA @12V and a weight of 195g. It has dimensions of 121 x 78 x 39 mm and an operating temperature range of -20°C to +50°C. The

Eden SOLO 3000

The Eden SOLO 3000 is a biometric reader with RS485 output that can store up to 3000 fingerprint templates. It is compatible with SENATORFX.NET software version 1.1.6.0 or later and SENATORFX software version 5.0.11 or later. The SOLO 3000 can be connected to C1P2FX control units version 2.4 or later, C4PLUSFX control units version 4.0 or later, and GENIUS control units version 1.0 or later.

The SOLO 3000 has a maximum power consumption of 300mA @12V and a weight of 195g. It has dimensions of 121 x 78 x 39 mm and an operating temperature range of -20°C to +50°C. The

Access control
SOLO / SOLO 3000
Biometric reader with RS485 output
Technical manual
Technical manual SOLO/SOLO3000 V1.5 p.2/12
Contents
Contents ......................................................................................................................... 2
Acknowledgement ......................................................................................................... 3
Information and recommendations .............................................................................. 4
Technical characteristics .............................................................................................. 5
1) SOLO/SOLO3000 .................................................................................................. 5
2) Compatibility .......................................................................................................... 5
Wiring diagram ............................................................................................................... 6
1) Connecting reader on C1P2FX control unit ........................................................... 6
2) Connecting reader on C4PLUSFX control unit ...................................................... 7
3) Connecting reader on GENIUS control unit ........................................................... 8
Connectors blocks ......................................................................................................... 9
Check list ....................................................................................................................... 10
Notes .............................................................................................................................. 11
Technical manual SOLO/SOLO3000 V1.5 p.3/12
Acknowledgement
Dear client,
You have just purchased a “SOLO/SOLO3000” fingerprint identification reader built by the
company EDEN INNOVATIONS.
The entire EDEN INNOVATIONS team would like to thank you for your interest as well as
your confidence in our security solution.
We hope that you will be completely satisfied with the level of security it provides for your
company’s premises.
Should you have any comments, please contact us via our web site at
www.eden-innovations.com
The EDEN INNOVATIONS team.
Technical manual SOLO/SOLO3000 V1.5 p.4/12
Information and recommendations
o Pursuant to European directive UTE C00-200, incorporating directives 89/336 EEC and 92/31
EEC, SOLO/SOLO3000 complies with the following standards:
• NF EN 50081-1 governing electromagnetic radiation, and
• NF EN 50082-1 governing electromagnetic susceptibility.
o Cabling recommendations: the cables used to connect readers, the network and other
peripherals must be installed in accordance with the instructions for Level 2 (protected
environment) of standard NF EN 61000-4-4.
o This product must be installed by an approved company. Incorrect installation and usage
may result in electric shock or fire. Before installing the product, read the technical information
and comply with the recommendations.
o Once the power is turned off, all the internal capacitors will discharge themselves to a
safe level after 60 seconds under normal conditions. However, in the event of a power
failure, the charge may be maintained for much longer and suitable.
Technical manual SOLO/SOLO3000 V1.5 p.5/12
Technical characteristics
1) SOLO/SOLO3000
Maximum power consumption ........ 300mA @12V
Power supply voltage ...................... 9 14VDC
Weight ............................................. 195 g
Housing dimensions ........................ 121 x 78 x 39 mm
Operating temperature .................... - 20°C to + 50°C
........................................................ -4°F to +122°F
Fingerprints SOLO .......................... 500 templates
Fingerprints SOLO3000 .................. 3000 templates
2) Compatibility
Software:
SENATORFX.NET .......................... V1.1.6.0 or later
SENATORFX .................................... V5.0.11 or later
Hardware:
C1P2FX .......................................... V2.4 or later
C4PLUSFX ..................................... V4.0 or later
GENIUS .......................................... V1.0 or later
Technical manual SOLO/SOLO3000 V1.5 p.6/12
Wiring diagram
1) Connecting reader on C1P2FX control unit
Data sheet :
Be sure to use the same pair for A and B
Be sure to separate the supply from the bus RS485
Characteristic: Sensitive connection
Screen: Mandatory
To achieve 1200m (2730 ft), you need to install a 120 resistor at each end of the network
between points A and B (see above).
Caution: The total length must not exceed the recommended distance.
A
B
A
B
SYT recommended
1200m (2730 ft) Max
Ø 0.6 mm (1/30 in)
2 pairs recommended
RS485
-
+
Technical manual SOLO/SOLO3000 V1.5 p.7/12
POWER
SUPPLY
12Vcc
2) Connecting reader on C4PLUSFX control unit
(?) Data sheet :
Be sure to use the same pair for A and B
Be sure to separate the supply from the bus RS485
Characteristic: Sensitive connection
Screen: Mandatory
To achieve 1200m (2730 ft), you need to install a 120 resistor at each end of the network
between points A and B (see above).
Note: The total length must not exceed the recommended distance.
A
B
A
B
SYT recommended
1200m (2730 ft) Max
Ø 0.6 mm (1/30 in)
2 pairs recommended
-
+
RS485
Technical manual SOLO/SOLO3000 V1.5 p.8/12
3) Connecting reader on GENIUS control unit
(?) Data sheet:
Be sure to use the same pair for A and B
Be sure to separate the supply from the bus RS485
Characteristic: Sensitive connection
Screen: Mandatory
To achieve 1200m (2730 ft), you need to install a 120 resistor at each end of the network
between points A and B (see above).
Note: The total length must not exceed the recommended distance.
A
B
A
B
SYT recommended
1200m (2730 ft) Max
Ø 0.6 mm (1/30 in)
2 pairs recommended
Power Supply
+12Vcc
+
-
RS485
Technical manual SOLO/SOLO3000 V1.5 p.9/12
Connectors blocks
Technical manual SOLO/SOLO3000 V1.5 p.10/12
Check list
SOLO / SOLO 3000
Serial number :
ID number :
Gasket :
Torx bit :
Torx screw :
Bag :
Wall seal :
Technical manual SOLO/SOLO3000 V1.5 p.11/12
Technical Support :
Notes
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
Zone Commerciale et Artisanale
670, route de Berre
13510 EGUILLES
France
www.eden-innovations.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Eden Solo Technical Manual

Type
Technical Manual
This manual is also suitable for

Eden SOLO 3000

The Eden SOLO 3000 is a biometric reader with RS485 output that can store up to 3000 fingerprint templates. It is compatible with SENATORFX.NET software version 1.1.6.0 or later and SENATORFX software version 5.0.11 or later. The SOLO 3000 can be connected to C1P2FX control units version 2.4 or later, C4PLUSFX control units version 4.0 or later, and GENIUS control units version 1.0 or later.

The SOLO 3000 has a maximum power consumption of 300mA @12V and a weight of 195g. It has dimensions of 121 x 78 x 39 mm and an operating temperature range of -20°C to +50°C. The

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI