OPO-5342

Concept OPO-5342 Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the Concept OPO-5342 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
EN
22
OPO5342
CONTENTS
Technical Parameters..............................1
Important notices.................................2
Product Description ...............................3
DescriptionoftheControlPanel....................3
Operating Instructions ............................4
Cleaning and Maintenance ........................5
Unit installation...................................6
Troubleshooting ..................................7
Service ...........................................7
Environmental Protection .........................7
Technical parameters
Voltage 230 V ~ 50 Hz
Power input 204 W
Version Island
ASSEMBLY Ceiling
Width 405 mm
Depth 305 mm
Height 865 – 1,120 mm
Output piping diameter 150 mm
Numberoffans 1
Numberoffanpowerlevels 4
Capacity Maximum 900 m3/h
Numberoffatlters 1
Mode Airing or re-circulation
Odor sensor/automatic mode Yes/Yes
Lighting 4 x 1 W LED
Weight 23 kg
Noise level, airing/re-circulation < 49/51 dB(A)
Themanufacturerreservestherighttoperformtechnicalmodicationsanddesignchangeswithoutpriornotice.
ThankyouforpurchasingaConceptproduct.Wehopeyouwillbesatisedwithourproductthroughoutitsservicelife.
PleasestudytheentireOperatingManualcarefullybeforeyoustartusingtheproduct.Keepthemanualinasafeplace
forfuturereference.Makesureotherpeopleusingtheproductarefamiliarwiththeseinstructions.
ACKNOWLEDGMENT
EN
23
OPO5342
IMPORTANT NOTICES:
Delivery
• Check the package and unit immediately after delivery for any damage that may have occurred during
shipping.
• Iftheunitisdamaged,donotoperateit.Contactthesupplierassoonaspossible.
• Removeallthecoveringandmarketingmaterialsfromtheunitbeforethefirstuse.
• Disposeofthepackagingmaterialproperly.
Installation
• Theunitisdesignedtobemountedontheceiling.
• Followtheinstructionsfortheapplianceconnectionandinstallation.
• Theunithastobedisconnectedfromthepowersocketduringinstallation.
• Beforeconnectingtheappliance,ensurethatyourlocalconnectionisearthedandcompliantwithallapplicable
regulations.
• Makesurethemainsvoltageandcurrentprotectioncorrespondtothevaluesontheratingplate.Useearthed
wall outlets only.
• Afterinstallationoftheunit,theplugorcircuitbreakershallbefreelyaccessible.
• Onlyanauthorizedtechnicianmayinstallandconnectyourappliance.
• Improperconnectionand/orincompetentinstallationmayresultininjuryordeath.
• Themanufacturertakesnoresponsibilityforanydamageincurredduetoimproperinstallationoruse.
Normal operation
• Usetheunitonlyasdescribedinthisoperatingmanual.
• Usetheunit only inahousehold,solely forthepurposeofabsorbing vaporcreatedduring cooking,orre-
circulationandabsorptionofodorscreatedduringcooking.
• Installtheunitatleast650mmaboveanelectricstove(orhotplate),and700mmatminimumaboveagasstove
(or gas hotplate).
• Neveroperatetheappliancewithwethands.
• Incaseofanyfailureandbeforemaintenanceandcleaning,turnofftheproductanddisconnecttheplugfrom
themainsoutlet,orswitchoffthecircuitbreaker.
• Neverpullthecordtodisconnecttheplugfromthewalloutlet;holdthepluginstead.
• Checktheapplianceandpowercordfordamageregularly.Neverswitchonadamagedappliance.
• Donotimmersethepowercord,plug,orapplianceinwateroranyotherliquid.
• MakesurethatallcontrolsareintheOFFpositionwhentheapplianceisnotinuse.
• Donothandleopenfireundertheunit(e.g.flaming)!Ifyouremoveacookingvesselfromagasstove,turndown
theflametotheminimum,orturnitoff!
Make sure the diameter of the burner of the gas stove or gas hotplate corresponds to the cookware used.
Whenusingsmallerthanrecommendedvessels,theflamescouldtouchthesides,andplastichandlescouldbe
scorched–riskoffire!
• Whenyoudeep-fryorfryfood,keepitundercontinuoussupervision.Whenoilisoverheated,thereisariskof
fire!
• Keep the intervals for the replacement and cleaning of the filters (every 2 months at minimum). If these
instructionsarenotfollowed,thereisariskoffireduetofatsedimentsinthefilters!
• Fortheventilationducts,alltheapplicablestandardsandregulationsshallbeobserved.
• Thediameterofductpipelinefortheairingmodeshouldbeapproximatelythesameasthediameterofthe
EN
24
OPO5342
A
B
C
PRODUCT DESCRIPTION
A Body of the unit
B Upper chimney cover
C Ceiling holder with fan
Accessories
1. Backflow valve
1
DESCRIPTION OF THE CONTROL PANEL
1. Fan power level setting buttons
2. Display of the set power level,
or time of delayed switching off
3. Delayed OFF timer setting button
4. Lighting ON/OFF button
1 2 3 4
outputpipeoftheabsorber.
• Theairshallnotbeventilatedthroughachimneyusedforcombustiongases,orinashaftusedforairingrooms
where combustion chambers are installed.
• Duringoperationinairingmodeasufficientopeningforinletairshallbemade;itssizeshallbeapproximately
thesameasorbiggerthanthatoftheholeforventilatedair.
• Duringsimultaneousoperationoftheunitinairingmodeandthestove,theunderpressureintheroomshallnot
exceed 4 Pa (0.04 mbar).
• Usemanufacturer-recommendedaccessoriesonly.
Children in the household
• The appliance is not intended for and should not be accessible to children or persons with reduced
capabilities.
• Theapplianceisnotintendedforusebypersonswithreducedphysical,sensoryormentalcapabilitiesorlackof
knowledge,unlessunderthesupervisionofanacquaintedpersonresponsiblefortheirsafety.
• Takeextracarewhenusingtheunitnearchildren.
• Donotusetheapplianceasatoy.
EN
25
OPO5342
OPERATING INSTRUCTIONS
Before first use
Priortothestartofuseofanewunit,wipeitwithawetandthenadrycloth.
Airing mode
Inthismodethevaporsareventilatedthroughtheoutputpipeintotheshaftandoutoftheroom.Ifthereare
carbonfiltersinstalledintheunit,removethem(seetheCleaningandMaintenanceparagraph).
1.Selecttherequiredfanpowerlevelbypressingthe„+“and„-“symbols(1–4).
2.Afteruse,switchtheunitoffbysettingthefanpowerlevelto„0“.
Re-circulation mode
Ifyouhavenopossibilitytoventilatetheairoutoftheroom,there-circulationmodecanbeselected.Inthismode
thevaporsarefilteredthroughmetalandcarbonfilters.Activecarboninthesefiltersabsorbssmells,andtheclean
airflowsbacktotheroomthroughholesintheupperchimneycover.Forthismode,itisnecessarytobuyand
assemblethecorrespondingcarbonfilters(seetheCleaningandMaintenanceparagraph).
1.Selecttherequiredfanpowerlevelbypressingthe„+“and„-“symbols(1–4).
2.Afteruse,switchtheunitoffbysettingthefanpowerlevelto„0“.
Switching the lighting on and off
Pressthebuttontoturnonthelight.Switchthelightoffbyrepeatedlypressingthesymbol.
The lighting direction can be adjusted by tilting the lights.
Delayed OFF function
1.Selecttherequiredfanpowerlevel(1–4).
2.Pressthesymboltoactivatethedelayedofffunction.Adotsymbolwillblinkonthedisplay.
3.Settherequireddelayedofftimebyrepeatedlypressingthe„-“and„+symbolsintherangeof10–90minutes.
Tensofminuteswillbedisplayed,i.e.1=10minutes,2=20minutesetc.Confirmbypressingthesymbol
(thefanpowerlevelwillbedisplayed,andthedotsymbolwillblink).
Note: If you don‘t confirm the delayed off settings within 20 seconds, the settings will be erased, and the
delayedofffunctionwillbedeactivated.
4.Theunitwillswitchoffautomaticallyafterthepresettimerunsout.
Note:Ifyoupressthesymbolduringthecountdown,orswitchoffthefanmanuallybeforethetimerunsout,
thedelayedofffunctionwillbedeactivated.
Automatic fan power regulation
Theunitisequippedwithanodorsensorthatdetectsanincreasedvolumeofodorsintheair.
Thisfunctionenablestheautomaticregulationoffanpowerdependingonthevolumeofodorsintheair.
Afterconnectingtoelectricpower,thefanshallnotbeswitchedonforabout5minutes,sothatthesensorcan
be calibrated.
Thefunctionisactivatedbypressingthe„–“symbolforalongertime.„A“willbedisplayed.
Todeactivatethefunction,pressthe„–“symbolforalongertime.
Filter replacement signal function
Thisfunctionisonlyindicative;itremindsyouwhenthefiltersshouldbecleanedorreplacedunderstandarduse.
Thefunctioncountshoursofoperation,i.e.theunitdoesnotdetectwhetheryouhavealreadyperformedthe
EN
26
OPO5342
replacementornot;itjustremindsyouthatacheck-up,cleaningorreplacementshouldbecarriedout.
„F“–signaltocleanthefatfilterswillbedisplayedafter100hoursofoperation.
„C“–signaltoreplacethecarbonfilterswillbedisplayedafter220hoursofoperation.
Youmayresetthecounterbypressingthesymbolfor10seconds;thedisplaywillgooff.
CLEANING AND MAINTENANCE
• Beforeany maintenance and cleaning, disconnect the power cord from the mains or switch off the circuit
breakerofthemainsoutletoftheunit.
• Do not immerse the power cord, plug, or appliance in water or any other liquid.
• SetallcontrolsintheOFFposition.
• Cleantheoutersurfaceoftheunitwithawetcloth,oruseaneutraldetergent.
• Donotusecoarsesponges,abrasivecleaners,solventsoraggressivedetergents.
• Donotuseanautoclavetocleantheunit!
CLEANING AND REPLACING THE FILTERS
a)Metalfatlter
Undernormaluse,themetalfatltershouldbecleanedevery2months.Incaseofmorefrequentfryingordeep
frying,shortentheinterval.
Donotusetheunitwithoutaproperlymountedmetalfatlter!
1.Openthefiltercasing(Fig.1).
2.Removethemetalfilter(Fig.2).Ifacarbonfilterismounted,removeit.
3.Leavethemetallterinwarmwaterwithadetergent.Cleanitwithasoftbrush,rinsewithcleanwaterandletdry.
4.Remountthecompletelydryfilterfollowingthereversesteps.
5.Closethefiltercasing.
Fig. 2Fig. 1
b)Carbonfilter(mustbepurchased)
Thisfilterisusedonlyinthere-circulationmode.
Thefiltercontainsactivecarbonthatabsorbstheventilatedodors.Afterawhiletheactivecarbonissaturated,and
losesitsabsorptionability.Thefiltercan‘tbewashedorotherwisecleaned.
Undernormaluse,thecarbonfiltershouldbereplacedevery2months.Incaseofmorefrequentfryingordeep
frying,shortentheinterval.
1.Openthefiltercasing(Fig.1).
2.Removethemetalfilter(Fig.2),andremovethecarbonfilterfromit.
3.Mountanewcarbonfilteronthemetalone(Fig.3),andputthesetback.
4.Closethefiltercasing.
EN
27
OPO5342
Fig. 3
Fig. 5 Fig. 6 Fig. 7
UNIT INSTALLATION
• Only authorized personnel can install the power connection!
• Only the customer is responsible for installation in situ. Defects caused by incorrect
installation are not covered by the warranty.
• Removeallthecoveringandmarketingmaterialsfromtheunitbeforetherstuse.
• Werecommendthatyouletaspecializedcompanyperformtheinstallation.
• Themanufacturerbearsnoresponsibilityfordamagecausedtopeople,animalsorobjects
asaresultofincorrectinstallation.
Follow the installation instructions:
1. Markthecenterofthehotplateontheceilingabove.
2. Drill holes. Fix the ceiling holder using the supplied wall plugs and screws (F) - Fig. 5.
3. Fortheairingmode,mountthebackowvalveontheoutputhole,andconnecttheoutput
holeofthefantotheholeintheceilingusingaexiblepipe.Ifnecessary,usetheadapter
(150/120 mm).
Note: Flexible pipe and diameter adapter are not supplied.
4. Mount the upper chimney cover to the ceiling holder (Fig. 6), and fix it using the screws
(F).
5. Opentheltercasingandremovethefat(orcarbon)lter.
6. Mountthebodyunitontheceilingholder(A),andxitfromtheinsideusingthescrews(D),
Fig.7.Keeptheminimumrequiredheightabovethehotplate(650mmforelectric,and700
mmforgashotplates,Fig.4).
7. Fix the electronic control plate so that the buttons and display go through the holes in the
unit‘sbody.
8. Open the switch box and connect the control cable. Connect all other possible connectors.
9. Mountthefat(orcarbon)lter.
10. Plug the supply cable into the wall outlet.
Fig. 4
EN
28
OPO5342
SUPPORTED ACCESSORIES
Metalfilter1pc Ord.No.61990007 Price:Seepricelist
Carbonfilter1pc Ord.No.61990004 Price:Seepricelist
150/120 mm diameter adapter Ord. No. 61990013 Price:Seepricelist
ENVIRONMENTAL PROTECTION
• Packagingmaterialsandobsoleteappliancesshouldberecycled.
• Thetransportboxmaybedisposedofassortedwaste.
• Polyethylenebagsshallbehandedoverforrecycling.
Appliance recycling at the end of its service life:
A symbol on the product or its packaging indicates that this product should not go into household waste.
Itmustbetakentothecollectionpointofanelectricandelectronicequipmentrecyclingfacility.Bymaking
surethisproductisdisposedofproperly,youwillhelppreventthenegativeeectsontheenvironment
andhumanhealththatwouldotherwiseresultfrominappropriatedisposalofthisproduct.Youcanlearnmoreabout
recyclingthisproductfromyourlocalauthorities,ahouseholdwastedisposalserviceorintheshopwhereyoubought
this product.
SERVICE
Anyextensivemaintenanceorrepairthatrequiresaccesstotheinnerpartsoftheproductmustbeperformedbyanexpert
service centre.
Removal
Beforeremoval,disconnectthepowercablefromwalloutlet,andfollowthereversestepstoremoveindividual
partsoftheunit.
TROUBLESHOOTING
Problem Cause, solution
The control does not work, or
does not work properly.
Therewasavoltageuctuationorblackoutinthenetwork.Disconnectthepower
sourcefor10seconds,thenreconnect.Thecontrolelectronicswillbereset.
Lowsuctionperformance Check and clean the metal filters, or replace the carbon filters.
"A" symbol is displayed. AutomaticfanpowerregulationfunctionisON.
"C" symbol is displayed. Signalforcheckorreplacementofthecarbonlter(re-circulation).
"F" symbol is displayed. Signalofcheckorcleaningofthefatlter(airingmode)
Jindřich Valenta - ELKO Valenta Czech Republic, Vysokomýtská 1800,
565 01 Choceň, Tel. +420 465 322 895, Fax: +420 465 473 304, www.my-concept.cz
Elko Valenta Slovakia s. r. o., Kasárenská 396/14, 911 05 Trenčín
Tel.: +421 326 583 465, Fax: +421 326 583 466, www.my-concept.sk
Elko Valenta Polska Sp. Z. o. o., Ostrowskiego 30, 53-238 Wroclaw
Tel.: +48 71 339 04 44, Fax: 71 339 04 14, www.my-concept.pl
/