OPO-5590

Concept OPO-5590 Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the Concept OPO-5590 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
EN
25
OPK4460, OPK4490, OPO5590
CONTENTS
Technical Parameters..............................1
Important notices.................................2
Product Description ...............................3
DescriptionoftheControlPanel....................4
Operating Instructions ............................4
Cleaning and Maintenance ........................5
Unit installation ..................................6
Troubleshooting ..................................7
Service ...........................................8
Environmental Protection .........................8
Technical parameters
OPK 4460 OPK 4490 OPO 5590
Voltage 230 V ~ 50 Hz
Power input 202 W 204 W
Version Chimney Island
ASSEMBLY On the wall On the ceiling
Width 600 mm 900 mm 900 mm
Depth 500 mm 600 mm
Height 650 – 900 mm 700 – 1000 mm 800 - 1000 mm
Diameter 150 mm 150 mm
Numberoffans 1
Numberoffanpowerlevels 4
Capacity Max. 900 m
3
/h
Numberoffatlters 2 3 3
Mode Airing or re-circulation
Odour sensor / automatic mode Yes/Yes
Lighting 2 x 1 W LED 4 x 1 W LED
Weight 14 kg 16 kg 15 kg
Noise level, airing/re-circulation < 49/51 dB(A)
Themanufacturerreservestherighttomaketechnicalmodicationsanddesignchangeswithoutpriornotice.
ThankyouforpurchasingaConceptproduct.Wehopeyouwillbesatisedwithourproductthroughoutitsservicelife.
PleasestudytheentireOperatingManualcarefullybeforeyoustartusingtheproduct.Keepthemanualinasafeplace
forfuturereference.Makesureotherpeopleusingtheproductarefamiliarwiththeseinstructions.
ACKNOWLEDGMENT
26
EN
OPK4460, OPK4490, OPO5590
IMPORTANT NOTICES:
Delivery
• Check the package and unit immediately after delivery for any damage that may have occurred during
shipping.
• Iftheunitisdamaged,donotoperateit.Contactthesupplierassoonaspossible.
• Removeallthecoveringandmarketingmaterialsfromtheunitbeforethefirstuse.
• Disposeofthepackagingmaterialproperly.
Installation
• Theunitisdesignedtobemountedonthewall(OPK4460andOPK4490),orontheceiling(OPO5590).
• Followtheinstructionsfortheapplianceconnectionandinstallation.
• Theunithastobedisconnectedfromthepowersocketduringinstallation.
• Beforeconnectingtheappliance,ensurethatyourlocalconnectionisearthedandcompliantwithallapplicable
regulations.
• Makesurethemainsvoltageandcurrentprotectioncorrespondtothevaluesontheratingplate.Useearthed
wall outlets only.
• Afterinstallationoftheunititsplugorcircuitbreakershallbefreelyaccessible.
• Onlyanauthorisedtechnicianmayinstallandconnectyourappliance.
• Improperconnectionand/orincompetentinstallationmayresultininjuryordeath.
• Themanufacturertakesnoresponsibilityforanydamageincurredduetoimproperinstallationoruse.
Normal operation
• Usetheunitonlyasdescribedinthisoperatingmanual.
• Usetheunitonlyinthehouseholdsolelyforthepurposeofabsorbingvapourcreatedduringcooking,orre-
circulationandabsorptionofodourscreatedduringcooking.
• Installtheunitatleast650mmabovetheelectriccooker(orhotplate),and700mmatminimumabovegas
cooker (or gas hotplate).
• Neveroperatetheappliancewithwethands.
• Incaseofanyfailureandbeforemaintenanceandcleaningturnofftheproductanddisconnecttheplugfrom
themainsoutlet,orswitchoffthecircuitbreaker.
• Neverpullthecordtodisconnecttheplugfromthewalloutlet;holdthepluginstead.
• Checktheapplianceandpowercordfordamageregularly.Neverswitchonadamagedappliance.
• Donotimmersethepowercord,plug,orapplianceinwateroranyotherliquid.
• MakesurethatallcontrolsareintheOFFpositionwhentheapplianceisnotinuse.
• Donothandleopenfireundertheunit(e.g.flaming)!Incaseyouremovecookingvesselfromgascooker,put
downtheflametominimum,orturnitoff!
Makesurethediameteroftheburnerofgascookerorgashotplatecorrespondswiththecookingkitchenware
used.Whenusingsmallerthanrecommendedvesselstheflamecouldtouchthesides,andtheplastichandles
couldbescorched–riskoffire!
• Whenyoudeep-fryorfryfood,keepitundercontinuouscontrol.Whenoilisoverheated,thereisariskoffire!
• Keeptheintervalsforreplacementandcleaningofthefilters(every2monthsatminimum).Iftheseinstructions
arenotfollowed,thereisariskoffireduetofatsedimentsinthefilters!
• Fortheventilationductsalltheapplicablestandardsandregulationsshallbeobserved.
• Thediameterofductpipelinefortheairingmodeshouldbeapproximatelythesameasthediameterofoutput
pipeoftheabsorber.
EN
27
OPK4460, OPK4490, OPO5590
PRODUCT DESCRIPTION
OPK 4460, OPK 4490
A Upper chimney cover
B Lower chimney cover
C Body of the unit
D Wall holder
E Wall holder of the upper chimney cover
F Upper cover
OPO 5590
A Body of the unit and lower chimney cover
B Upper chimney cover
C Ceiling holder with fan
Accessories
1. Backflow valve
1
• Theairshallnotbeventilatedthroughachimneyusedforcombustiongases,orinashaftusedfortheairingof
rooms where combustion chambers are installed.
• Duringtheoperationinairingmodeasufficientorificefortheinputairshallbemade,itssizeapproximatelythe
sameorbiggerthanthatoftheholeforventilatedair.
• Duringsimultaneousoperationoftheunitinairingmodeandthecookerstheunderpressureintheroomshall
not exceed 4 Pa (0.04 mbar).
• Usemanufacturer-recommendedaccessoriesonly
Children in the household
• The appliance is not intended for and should not be accessible to children or persons with reduced
capabilities.
• Theapplianceisnotintendedforusebypersonswithreducedphysical,sensoryormentalcapabilitiesorlackof
knowledge,unlessunderthesupervisionofanacquaintedpersonresponsiblefortheirsafety.
• Takeextracarewhenusingtheunitnearchildren.
• Donotusetheapplianceasatoy.
28
EN
OPK4460, OPK4490, OPO5590
OPERATING INSTRUCTIONS
WARNING!
• Thetouchcontrolisactivatedbyputtingafingerontherequiredsymbolonthecontrolpanel.Thereforekeep
the control panel clean and dry.
• Ateachpressingofasymbolabeepcanbeheard.Theresponsetimeforpressingasymbolis1second,forwhich
timeitisnecessarytoholdafingeronthesymbol.
• Thesensorsdonotrespondtomattdarkcolours(donotuseblackgloves).
• Makesuretheunitisnotaccidentallyswitchedon,e.g.duringcleaning!
Before the first use
Priortothestartofuseofanewunit,wipeitwithawetandthenadrycloth.
Airing mode
Inthismodethevapoursareventilatedthroughtheoutputpipeintotheshaftandoutoftheroom.Incasethere
arecarbonfiltersinstalledintheunit,removethem(seeCleaningandmaintenancechapter).
1.Selecttherequiredfanpowerlevelbypressing„+“and„-“symbols(1–4).
2.Aftertheuseswitchtheunitoffbysettingthefanpowerlevelto„0“.
Re-circulation mode
Ifyouhavenopossibilitytoventilatetheairoutoftheroom,re-circulationmodecanbeselected.Inthismodethe
vapoursarefilteredthroughmetalandcarbonfilters.Activecarboninthesefiltersabsorbssmells,andtheclean
airflowsbacktotheroomthroughholesintheupperchimneycover.Forthismodeitisnecessarytobuyand
assemblecorrespondingcarbonfilters(seeCleaningandmaintenancechapter).
1.Selecttherequiredfanpowerlevelbypressing„+“and„-“symbols(1–4).
2.Afteruseswitchtheunitoffbysettingthefanpowerlevelto„0“.
Switching the lighting on and off
SwitchthelightonbypressingtheLsymbol.SwitchthelightoffbyrepeatedpressingoftheLsymbol.
Delayed OFF function
1.Selecttherequiredfanpowerlevel(1–4).
2.BypressingtheT“symbolactivatethedelayedofffunction.Adotsymbolwillblinkonthedisplay.
3.Settherequireddelayedofftimebyrepeatedpressingof-“and+“symbolsintherange10–90minutes.Tens
ofminuteswillbedisplayed,i.e.1=10minutes,2=20minutesetc.Confirmbypressingthe„T“symbol(fan
power level will be displayed, and dot symbol will blink).
DESCRIPTION OF THE CONTROL PANEL
1. Fan power level setting symbols
2. Display of the set power level, or time of delayed
switch off
3. Symbol of setting the delayed OFF timer
4. Symbol of lighting ON/OFF
1 2 3 4
EN
29
OPK4460, OPK4490, OPO5590
Note: If you don‘t confirm the delayed off settings within 20 seconds, the settings will be erased, and the
delayedofffunctionwillbedeactivated.
4.Theunitwillswitchoffautomaticallyafterthepresettimerunsout.
Note: IncaseyoupresstheT“symbolduringthecountdown,orswitchoffthefanmanuallybeforethetime
runsout,thedelayedofffunctionwillbedeactivated.
Automatic fan power regulation
Theunitisequippedwithaso-calledodoursensorthatdetectsanincreasedvolumeofodoursintheair.
Thisfunctionenablesautomaticregulationoffanpowerdependingonthevolumeofodoursintheair.
Afterconnectingtoelectricpowerthefanshallnotbeswitchedonforabout5minutes,sothatthesensorcanbe
calibrated.
Thefunctionisactivatedbyalongpressingofthe„–“symbol.An„A“willbedisplayed.
Todeactivatethefunction,long-pressthe“symbol.
Filter replacement signal function
Thisfunctionisonlyindicative,itremindsyouwhenthefiltersshouldbecleanedorreplacedunderstandarduse.
Thefunctioncountshoursofoperation,i.e.theunitdoesnotdetectwhetheryouhavealreadyperformedthe
replacementornot;itjustremindsyouthatacheck-up,cleaningorreplacementshouldbecarriedout.
„F“–signaltocleanthefatfilterswillbedisplayedafter100hoursofoperation.
„C“–signaltoreplacethecarbonfilterswillbedisplayedafter220hoursofoperation.
YoumayresetthecounterbypressingtheT“symbolfor10seconds,thedisplaywillgooff.
CLEANING AND MAINTENANCE
• Beforeanymaintenanceandcleaningdisconnectthepowercordfromthemainsorswitchoffthecircuitbreaker
ofthemainsoutletoftheunit.
• Donotimmersethepowercord,plug,orapplianceinwateroranyotherliquid.
• SetallcontrolsintheOFFposition.
• Cleantheoutersurfaceoftheunitwithawetcloth,oruseaneutraldetergent.
• Donotusecoarsesponges,abrasivecleanersorcausticagentssuchasovencleanerorstainremover.
• Donotuseautoclaveforcleaningtheunit!
CLEANING AND REPLACING THE FILTERS
a)Metallicfatfilters
Undernormalusethemetallicfatfiltersshouldbecleanedevery2months.
Incaseofmorefrequentfryingordeepfryingmaketheintervalshorter.
Donotusetheunitwithoutproperlymountedmetallicfatfilters!
1.Removethemetallicfilters(Fig.1).Incasetherearecarbonfiltersmounted,
remove them.
2.Putthemetallicfiltersinwarmwaterwithadetergent.Cleanthemwitha
softbrush,rinsewithcleanwaterandletdry.
3.Remountcompletelydryfiltersfollowingthereversesteps.
Fig. 1
30
EN
OPK4460, OPK4490, OPO5590
UNIT INSTALLATION
• Only authorised personnel can install the power connection!
• Onlythecustomerisresponsibleforinstallationinsitu.Defectscausedbyincorrectinstallationarenotcovered
by the warranty.
• Removeallthecoveringandmarketingmaterialsfromtheunitbeforethefirstuse.
• Werecommendyoutoletaspecialisedcompanyperformtheinstallation.
• Themanufacturerbearsnoresponsibilityfordamagecausedtopeople,animalsorobjectsasaresultofincorrect
installation.
Follow the installation instructions:
a) Chimney type (models OPK 4460, OPK 4490)
1.Marktheminimumrequiredassemblyheightonthewallbehindthehotplate(650mmforelectric,and700mm
forgashotplates,Fig.3).
2.Markthepositionofcentreofthehotplatebyaverticalline.
3.Drillholes,fixwallholder(D)attherequiredheightusingthesuppliedwallplugs(G)andscrews(H)(960mm
forelectricand1010mmforgashotplates,Fig.3).
4.Hangthebodyoftheunitontheholder(K).Settheexactverticalpositionbyscrews(J)and(I),Fig.4.
5.Fortheairingmodemountthebackflowvalveontheoutputhole,andconnecttheoutputholeofthefanwith
holetheinthewallusingflexiblepipe.Ifneedbeusetheadapter(150/120mm).
Note: Flexible pipe and diameter adapter are not supplied.
6.Mountboththechimneycoversonthebody(KandN),shifttheupperchimneycover(N)totherequiredheight,
and mark its upper edge on the wall (Fig. 4 and 5. Remove both the chimney covers.
7.Measureandmarka16mmdistanceunderthemarkedmaximumheightoftheupperchimneycover.Drillholesat
thisheight,andxthewallholderoftheupperchimneycover(E).Ifnecessaryusetheuppercover(F),Fig.5.
8. Mount and screw the lower and upper chimney covers.
9. Plug the supply cable in the wall outlet.
b)Carbonfilters(mustbepurchased)
Thesefiltersareusedonlyinthere-circulationmode.
Thefilterscontainactivecarbonthatabsorbstheventilatedodours.Afterawhiletheactivecarbonissaturated,
andlosesitsabsorptionability.Thesefilterscan‘tbewashedorotherwisecleaned.
Undernormalusethecarbonfiltersshouldbereplacedevery2months.Incaseofmorefrequentfryingordeep
fryingmaketheintervalshorter.
1.Removethemetallicfilters(Fig.1),andremovecarbonfiltersfromthem.
2.Mountnewcarbonfilterstothemetallicones(Fig.2),andputthesetback.
Fig. 2
EN
31
OPK4460, OPK4490, OPO5590
b) Island type (model OPO 5590)
1.Markthecentreofthehotplateontheceilingabove.
2.Drillholes,fixtheceilingholderusingsuppliedwallplugsandscrews(Fig.7).
3.Fortheairingmodemountbackflowvalveontheoutputhole,andconnecttheoutputholeofthefanwiththe
holeinthewallusingflexiblepipe.Ifneedbeusetheadapter(150/120mm).
Note: Flexible pipe and diameter adapter are not supplied.
4.Mounttheupperchimneycoverontheceilingholder(Fig.8),andfixitusingthescrews(B).
5.Mountthelowerchimneycoverontheceilingholder(Fig.9and10),shiftupandfixtothebodyusingscrews
(C).Keeptheminimumrequiredheightabovethehotplate(650mmforelectric,and700mmforgashotplates,
Fig. 6).
6. Open the switch box and connect the control cable. Connect all other possible connectors.
7.Plugthesupplycableinthewalloutletandshiftthelowerchimneycoverdown.
Fig. 3 Fig. 4 Fig. 5
Fig. 7 Fig. 8 Fig. 9 Fig. 10
32
EN
OPK4460, OPK4490, OPO5590
SUPPORTED ACCESSORIES
Metalfilter1pc Ord.No.61990001 Price:Seepricelist
Carbonfilter1pc Ord.No.61990002 Price:Seepricelist
150/120 mm diameter adapter Ord. No. 61990013 Price: See price list
Removal
Beforeremovaldisconnectthepowercablefromwalloutlet,followthereversestepstoremoveindividualparts
oftheunit.
TROUBLESHOOTING
Problem Cause, solution
The control does not work, or
does not work properly.
Therewasavoltageuctuationorblackoutinthenetwork.Disconnectthepower
sourcefor10seconds,thenconnectagain.Thecontrolelectronicswillbereset.
Lowsuctionperformance Check and clean he metallic filters, or replace the carbon filters.
"A" symbol is displayed. AutomaticfanpowerregulationfunctionisON.
"C" symbol is displayed. Signalforcheck-uporreplacementofcarbonlter(re-circulation).
"F" symbol is displayed. Signalofcheck-upofcleaningfatFilter(airingmode)
ENVIRONMENTAL PROTECTION
• Packagingmaterialsandobsoleteappliancesshouldberecycled.
• Thetransportboxmaybedisposedofassortedwaste.
• Polyethylenebagsshallbehandedoverforrecycling.
Appliance recycling at the end of its service life:
A symbol on the product or its packaging indicates that this product should not go into household waste.
Itmustbetakentothecollectionpointofanelectricandelectronicequipmentrecyclingfacility.Bymaking
surethisproductisdisposedofproperly,youwillhelppreventthenegativeeectsontheenvironment
andhumanhealththatwouldotherwiseresultfrominappropriatedisposalofthisproduct.Youcanlearnmoreabout
recyclingthisproductfromyourlocalauthorities,ahouseholdwastedisposalserviceorintheshopwhereyoubought
this product.
SERVICE
Anyextensivemaintenanceorrepairthatrequiresaccesstotheinnerpartsoftheproductmustbeperformedbyanexpert
service centre.
/