EOL LEARN Button: Enters and exits
“Auto Learn” mode.
MEMORY RESET Button: Clears
memory and resets the device to
factory defaults when held for 3
seconds during power up
PROCESSOR LED: Flashes during
normal operation
RF XMIT LED: Flashes when RF
transmission is being sent
EOL CAL LED: Flashes when no
zones have been learned in yet. ON
when device is in “Auto Learn” mode.
OFF when device is in “Normal
Operation Mode”
ZONES 1-15 LEDs: OFF while in
“Auto Learn” mode unless a zone has
been learned in or tripped, then ON.
OFF while in “Normal Operation
Mode” unless a zone is open, then
ON or if a zone is tampered, then
FLASHES
ZONE 16 SMOKE LED: ON when
smoke detector is in alarm
HOW TO CLEAR THE MEMORY:
Power down the unit by unplugging
the battery leads and the power
supply. Hold down “Memory Reset”
for 3 seconds while re-applying
power to the device. Processor, RF
Xmit and EOL CAL LED’s will begin to
flash rapidly indicating that the
module has been reset.
NOTE: It is recommended to Clear the
Memory when installing unit for the
first time or when switching between
Resistor Modes if devices have
previously been enrolled into the IQ
Hardwire 16
R E S I S T O R M O D E S : C h a n g e
between two distinct resistor modes.
The default mode is “UL Mode”
where 4.7k resistors are required on
each zone. In this mode the
Processor LED blinks rapidly (8 times
per second).
If UL installation is not required, “EOL
Resistor Learning” can be enabled. In
this mode the Processor LED blinks
slowly (1 time per second) and any
resistor value from 1k to 10k can be
used.
NOTE: Zone 16 is dedicated for 2-wire
smokes and requires a 4.7k resistor
regardless of Resistor Mode.
To change modes, first power down
the unit by unplugging the battery
leads and the power supply. Next
hold down “EOL LEARN” for 8
seconds while re-applying power to
the device. Processor, RF Xmit and
EOL CAL LED’s will begin to flash
rapidly indicating that the mode has
been changed
Page of 4 Qolsys Confidential and Proprietary.3
Trip (Open/Close) each
hardwired zone one at a
time.
Two-wire smoke detectors
should be activated via the
test button on the detector
or with a can of smoke
Once all desired zones have been
learned, press the “EOL LEARN”
button to exit “Auto Learn” mode.
The EOL CAL LED will turn OFF
indicating you are no longer in
“Auto Learn” mode and all zone
LED’s will turn OFF.
When a sensor has been
tripped, the Zone LED will
illuminate and stay on until
you exit “Auto Learn” mode.
STEP 3: PAIRING INDIVIDUAL ZONES/SENSORS
Customize the sensor
type and settings as
desired. Repeat for
each zone.
The IQ Panel 2 will
“chime” indicating it
has found a new
sensor. Touch “OK”
to proceed.