3. VIEW OF THE FRONT AND BACK PANEL
------------------------------------------------------------------------------------
1)
with a PC - USB
2) LAN Filter RJ45
3) Power cord socket
IEC 320 C14
4) Outlet sockets
2 x IEC 320 C13
2 x PN-E-93201
5) Circuit breaker
Port for communication
1) LCD Display
2) Power switch
1
2
USB
Warranty
Power
cord
Quick reference
guide
5. INSTALATION AND CONNECT
L
N
PE
TN-S
L
N
PE
L
N
PE
UPS
L
N
PE
123
4
L
N
PE
TN-C-S
L
N
PE
L
N
PE
UPS
L
PEN
123
4
L
N
TN-S
L
N
PE
L
N
PE
UPS
L
N
PE
123
4
ON
ON
OFF ON
>20cm
>20cm
7. LAN FILTER CONNECTION 8. CONTACT
EVER Sp. z o.o.
ups@ever.eu
www.ever.eu
+5 ÷ +35 °C
1. IN THE PACKAGING
UPS EVER EASYLINE AVR USB
• EASYLINE 1200 AVR USB
Note: to obtain detailed information, please read the full instruction manual, which can be
downloaded from our website www.ever.eu.
QUICK REFERENCE GUIDE
The range of UPS units is not intended to work directly with
medical equipment, life-supporting equipment or any other equipment that may have
effect on health.
EASYLINE AVR USB
2. ADDITIONAL REMARKS
Correct way of
connecting the UPS
1) Mains
2) Input
3) Output
4) Load
Layout of terminals in
the power socket
Layout of terminals in
outlet sockets
In case of a fault other than overload or short circuit
following message is active
The UPS operates in normal mode (supplied from
mains power). The message is displayed.
INPUT
OUTPUT
VDC
HZ
VAC
INPUT BATTERY OUTPUT LOAD
FAULT
VAC
HZ
%
LINE MODE
(
AVR
)
BACKUP MODE
Test window of the LCD display shown during the 3
seconds.
Load capacity indication - 4-grade scale (further
segments light up along with increasing load).
Battery charging level indication - 4-grade scale
(further segments light up along with increasing
battery charge level).
Display of input parameters (input voltage and input
frequency).
Display of output parameters (output voltage and
output frequency).
VAC
INPUT OUTPUT VAC
LINE MODE LINE MODE
VAC
INPUT OUTPUT VAC
LINE MODE
(
AVR
)
Signaling of AVR acitivity. Icon flashes every 1
second.
VAC
INPUT OUTPUT VAC
BACKUP MODE
The UPS operates in buffer (battery) mode. Icon
flashes every 1 second.
VAC
INPUT OUTPUT VAC
Indication of power supply in charging mode. In this
mode, the power supply does not provide power to the
output terminals. This situation occurs when UPS is
not switched on with front panel power button but it is
plugged to power supply socket.
FAULT FAULT
4. DESCRIPTION OF LCD DISPLAY ICONS 6. FIRST START
SOFTWARE
DOWNLOAD
WWW.EVER.EU
max. 1,5m
1
2
4
3
------------------------------------------------------------------------------------
L
L
N N
PE PE
LPE N
USB
RJ45
RJ45
Sieć komputerowa
10/100 Base-T
USB
230V
6 h
5
v3 20150430
Type 01