ekwb EK-Quantum Reflection 1000D D5 PWM D-RGB Installation guide

Type
Installation guide
USER GUIDE
DISTRIBUTION PLATE
EKQuantum
Reflection 1000D
Before you start using this product please follow these basic guidelines:
Please carefully read the manual before beginning with the
installation process!
The EK Fittings require only a small amount of force to screw
them firmly in place since the liquid seal is ensured by the
rubber O-ring gaskets.
The use of corrosion inhibiting coolants is always recommended
for any liquid cooling system. EKWB recommends any of the
EKCryofuel for worry-free usage.
- 3 -
TABLE OF CONTENT
ATTACHING MOUNTING BRACKETS 4
ATTACHING THE DISTRIBUTION PLATE ON THE MOUNTING BRACKETS 5
RECOMMENDED DISTRIBUTION PLATE CONFIGURATIONS 6
CONNECTING THE D-RGB LED STRIP 7
CONNECTING THE PUMP 8
CONNECTING THE PUMP MOLEX CONNECTOR 8
CONNECTING THE PUMP – SATA CONNECTOR 8
TESTING THE LOOP 9
SUPPORT AND SERVICE 10
SOCIAL MEDIA 10
- 4 -
Attach the mounting brackets on PC case using M3 X 6 DIN7380
Screws and M3 nuts.
ATTACHING MOUNTING BRACKETS
M3 x 6 DIN7380
M3 Nut
M3 x 6
DIN7380
M3 x 6
DIN7380
M3 Nut
LOWER MOUNTING BRACKET
UPPER MOUNTING BRACKET
- 5 -
STEP 1
STEP 1
UPPER MOUNTING BRACKET
Carefully place the EK-Quantum Reflection 1000D distribution
plate on the Upper mounting bracket. Secure it with enclosed M4 X
8 DIN7984 screws and steel washers.
ATTACHING THE DISTRIBUTION PLATE ON THE MOUNTING BRACKETS
STEP 2
STEP 2
LOWER MOUNTING BRACKET
Attach the EK-Quantum Reflection 1000D D5 distribution plate on
the Lower mounting bracket and secure it with enclosed M4 X 8
7984DIN Screws and steel washers.
Steel Washer
M4 x 8
DIN7984
Steel Washer
M4 x 8
DIN7984
- 6 -
RECOMMENDED DISTRIBUTION PLATE CONFIGURATIONS
In order to complete your loop, all of the ports should be used as
marked on the diagrams.
All remaining and unused ports should be closed using the
supplied plugs and a EK-Loop Multi Allen Key (6mm, 8mm, 9mm).
FILL VRM OUTLET
(OPTIONAL)
RADIATOR 2 INLET
(WITH VRM)
RADIATOR 2
OUTLET
RADIATOR 2 INLET
(WITHOUT VRM)
GPU OUTLET
(One must be used)
GPU OUTLET (Using
CPU2 OR GPU2)
(One must be used)
CPU(2) OR GPU(2)
INLET (OPTIONAL)
CPU(2) OR GPU(2)
OUTLET (USING
CPU2 AND GPU2)
DRAIN
VRM INLET
(OPTIONAL)
RADIATOR 1
INLET
RADIATOR 1
OUTLET
(With VRM)
RADIATOR 1
OUTLET
(Without VRM)
GPU INLET
(One must be used)
CPU(2) OR GPU(2)
INLET (USING
CPU2 AND GPU2)
CPU(2) OR GPU(2)
OUTLET
(OPTIONAL)
CPU INLET
CPU OUTLET
- 7 -
Plug the 3-pin connector of the distribution plate D-RGB LED light to
the D-RGB HEADER on the motherboard. The LED will work if the pin
layout on the header is as follows: +5V, Digital, Empty, Ground.
Please ensure that the arrow indicated on the connector is
plugged into the +5V line as indicated on your motherboard.
If you put LED Diode to the 12V RGB HEADER you can
damage the LEDs.
Connector is the same on D-RGB and RGB versions,
but D-RGB version has 3 cables from connector to PCB;
RGB version has 4 cables. If you connect D-RGB led to
ordinary RGB header you can damage your motherboard
or LED strip.
D-RGB Header
RGB Header
CONNECTING THE D-RGB LED STRIP
D-RGB Connector
- 8 -
CONNECTING THE PUMP
CONNECTING THE PUMP  MOLEX
CONNECTOR
The EK-D5 PWM pump has two connectors.
1. MOLEX Connector: It must be connected directly to your PSU at
all times as it is used to power the pump.
2. 4-pin PWM fan: It can be connected to your motherboard’s
CPU_ Fan or designated water pump header. It can also be
connected to a controller. This cable is used to control and report
the rotational speed of the pump. If it’s not connected, the pump
will run at maximum speed (100% PWM).
4-PIN MOLEX
CONNECTOR
4-PIN PWM FAN
CONNECTOR
CONNECTING THE PUMP  SATA CONNECTOR
The EK-D5 PWM pump has two connectors.
1. SATA Connector: It must be connected directly to your PSU at all
times as it is used to power the pump.
2. 4-pin PWM fan: It can be connected to your motherboard’s
CPU_ Fan or designated water pump header. It can also be
connected to a controller. This cable is used to control and report
the rotational speed of the pump. If it’s not connected, the pump
will run at maximum speed (100% PWM).
SATA
CONNECTOR 4-PIN PWM FAN
CONNECTOR
- 9 -
To make sure the installation of EK components was successful, we
recommend you perform a leak test for 24 hours.
When your loop is complete and filled with coolant, connect the
pump to a PSU outside of your system. Do not connect power to
any of the other components. Turn on the PSU and let the pump
run continuously. It is normal for the coolant level to drop during this
process as air collects in the distribution plate.
Inspect all parts of the loop, and in the eventuality that coolant leaks,
fix the issue and repeat the testing process. Ensure that all hardware is
dry before the system is powered on in order to prevent any damage.
TESTING THE LOOP
For assistance please contact:
http://support.ekwb.com/
EKWB d.o.o.
Pod lipami 18
1218 Komenda
Slovenia - EU
EKWaterBlocks
@EKWaterBlocks
ekwaterblocks
ekwaterblocks
EKWBofficial
SUPPORT AND SERVICE
SOCIAL MEDIA
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

ekwb EK-Quantum Reflection 1000D D5 PWM D-RGB Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI