Mitsubishi Electric AE-200A, part of an air conditioning control system, offers precise temperature management for various indoor units. It enables flexible installation with a mounting kit for control panel placement. The unit ensures efficient and reliable operation of your air conditioning system.

Mitsubishi Electric AE-200A, part of an air conditioning control system, offers precise temperature management for various indoor units. It enables flexible installation with a mounting kit for control panel placement. The unit ensures efficient and reliable operation of your air conditioning system.

Installation Manual
PAC-YG86TK-J
Air Conditioning Control System - Optional Parts
Mounting Kit (for control panel)
Contents
Safety precautions ·················································
14
1. Parts to be used ··················································
15
1-1. Package contents ··············································
15
1-2. Commercially available parts ······························
15
1-3. External dimensions ··········································
16
2. General description of installation ·····················
17
3. Selecting the installation site ·····························
18
3-1. Required installation space ·································
18
4. Installation ··························································
19
4-1. Before installation ··············································
19
4-2. Installation method ············································
20
5. Wiring connections ·············································
23
For distribution to dealers and contractors only
Applicable Model AE-200A/AE-50A
AE-200E/AE-50E
Before installing the controller, please read this Installation Manual carefully to ensure proper operation.
Retain this manual for future reference.
Safety precautions
Thoroughly read the following safety precautions prior to installation.
Observe these precautions carefully to ensure safety.
After reading this manual, pass the manual on to the end user to retain for future
reference.
The user should keep this manual for future reference and refer to it as necessary. This
manual should be made available to those who repair or relocate the units. Make sure
that the manual is passed on to any future air conditioning system user.
All electrical work must be performed by qualified personnel.
: indicates a hazardous situation which, if not avoided, could result
in death or serious injury.
: indicates a hazardous situation which, if not avoided, could result
in minor or moderate injury.
General precautions
To reduce the risk of injury, electric shock, or malfunction, avoid contact with the sharp
edges of certain parts.
To reduce the risk of injury, wear protective gear when working on the controller.
Precautions for unit installation
Properly dispose of the packing materials. Plastic bags pose a suffocation hazard to
children.
Take appropriate safety measures against earthquakes to prevent the controller from
causing injury.
To prevent injury, install the controller on a flat surface strong enough to support its
weight.
Precautions for relocating or repairing the unit
The controller must be repaired or moved only by qualified personnel. Do not
disassemble or modify the controller. Improper installation or repair may result in injury,
electric shock, or fire.
14
WT07320X01
1. Parts to be used
1-1. Package contents
No. Package contents Shape Qty. Notes
1 Mounting Kit 1
2 DIN rail attachment 2
3 Screw 4Use to fix the DIN rail
attachments.
4Installation Manual
(this manual) 1
1-2. Commercially available parts
No. Parts Shape Qty. Notes
1 ø4 screw 4
Required for wall-surface
installation.
Use screws that are
suitable for the wall type.
2 DIN rail As appropriate
3 DIN rail fixing screw As appropriate *1
Required when using DIN
rails.
Use screws that are
suitable for the wall type.
4 Control box As appropriate 200 mm (7-7/8 in) depth or
above
*1 The total weight of the AE-200A/AE-50A/AE-200E/AE-50E and the Mounting Kit is approximately 2.7 kg. Use the
appropriate amount of fixing screws to secure the strength.
WT07320X01
15
1-3. External dimensions
[1] Mounting Kit
272.8 (10-3/4)
261.2 (10-5/16)
66 (2-5/8)
148 (5-7/8)
188 (7-7/16)
41 (1-5/8)
4 (3/16)
38 (1-1/2)
25 (1/1) 29 (1-3/16)
45 (1-13/16)
35 (1-7/16)
ø10
(7/16)
4.5 (3/16)
4.5
(3/16)
12.5 (1/2)
261.2 (10-5/16)
294.8 (11-5/8)
317.2 (12-1/2)
329.2 (15-1/2)
69.2 (2-3/4)
Burring hole 4-M4 × 0.7 (1/16)
Unit: mm (in)
Burring hole
4-M3 × 0.5 (1/16)
16
WT07320X01
2. General description of installation
AE-200/AE-50 body
Screw (supplied)
DIN rail attachment
(supplied)
Mounting Kit (supplied)
DIN rail attachment (supplied)
Plate A fixing screw
(supplied with AE-200/AE-50)
* Hereafter, AE-200A and AE-200E, unless otherwise specified, will be called “AE-200.”
Hereafter, AE-50A and AE-50E, unless otherwise specified, will be called “AE-50.”
WT07320X01
17
3. Selecting the installation site
3-1. Required installation space
[1] Required space around the AE-200/AE-50
284
(11-3/16)
200 (7-7/8)
50
(1-1/1)
40
(1-5/8)
50
(1-1/1)
50
(1-1/1)
[2] Required vertical shift distance
When the depth of the control box is below 200 mm (7-7/8 in), shift the controllers vertically as shown in the figure below so
that their components will not be in contact with each other.
200 (7-7/8)
40 (1-5/8)
Mounting Kit
AE-200/AE-50 body
Unit: mm (in)
Installation space
Control box
Unit: mm (in)
18
WT07320X01
4. Installation
4-1. Before installation
1. Remove the cover.
Refer to the Installation Manual of the AE-200/AE-50 for how to remove the cover.
2. Attach the Mounting Kit.
3. Reinstall the cover.
AE-200/AE-50 body
Mounting Kit (supplied)
Plate A fixing screw
(supplied with AE-200/AE-50)
AE-200/AE-50 body
Cover
WT07320X01
19
4-2. Installation method
[1] Installation using DIN rail
1. Attach the supplied two DIN rail attachments to the Mounting Kit with the supplied screws.
*1 Install the DIN rail attachments in the correct orientation as shown in the figure.
2. Install the DIN rail on a strong wall surface.
Mounting location
152 (5-1/1)
167 (6-5/8)
152 (5-1/1)
167 (6-5/8)
10 (7/16)
AE-200/AE-50 body
DIN rail attachment *1
(supplied)
Screw (supplied)
DIN rail fixing screw
DIN rail To a strong wall surface
Do not screw the DIN rail fixing
screws here.
Unit: mm (in)
20
WT07320X01
3. Mounting the AE-200/AE-50 on the DIN rail
Removing the AE-200/AE-50 from the DIN rail
WT07320X01
21
[2] Wall-surface installation
1. Install the AE-200/AE-50 on a strong wall with ø4 screws.
• To remove the AE-200/AE-50 after the installation, remove the Plate A fixing screws that fix the AE-200/AE-50 and the
Mounting Kit.
Mounting location
147.4 (5-13/16)147.4 (5-13/16)
29 (1-3/16)
21 (7/8)
ø4 screws (not supplied)
AE-200/AE-50 body
To a strong wall surface
Unit: mm (in)
22
WT07320X01
5. Wiring connections
When routing the cables from the bottom, remove the service cover, cut out the knockout holes, cut a slit in the supplied
rubber bushings (supplied with the AE-200/AE-50), attach the bushings to the knockout holes, insert the cables with no gap,
and reinstall the service cover.
Service cover
WT07320X01
23
Please be sure to put the contact address/telephone number
on this manual before handing it to the customer.
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN WT07320X01
872C600A20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Mitsubishi Electric AE-200A User manual

Type
User manual

Mitsubishi Electric AE-200A, part of an air conditioning control system, offers precise temperature management for various indoor units. It enables flexible installation with a mounting kit for control panel placement. The unit ensures efficient and reliable operation of your air conditioning system.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI