Firmware Update Procedure
What You’ll Need
Figure 2. USB mini to USB Cable Figure 3. Local PC
Figure 1. SNYPER Signal Analyser
»SNYPER Signal Analyser
»Siretta Approved USB Mini to USB Cable
»PC / Laptop
SNYPER Layout
Registered in England No. 08405712
VAT Registration No. GB163 04 0349
Siretta Ltd
Basingstoke Road
Spencers Wood
Reading
Berkshire RG7 1PW
sales
fax
email
web
+44(0)118 976 9000
+44(0)118 976 9020
www.siretta.com
9
SNYPER-LTE Graphyte
User Manual
Product Images
Figure 1. Front view of the SNYPER-LTE Graphyte
320 x 240
LCD Display
(51 x 38mm viewing area)
RIGHT Button
BACK Button
DOWN Button
OK Button
LEFT Button
Charge Status
LED
ON/OFF Button
UP Button
First Step...
Figure 4. SNYPER Functions
Prepare your SNYPER as follows:
Next Step...
»Ensure the latest SNYPER software is installed on the device.
»This process will work on software version 06.10.xx onwards.
***IMPORTANT***
»Double check the rmware is correct for your V1 device before attempting to update the rmware.
***IMPORTANT***
»The silver label on the back of the SNYPER will clearly identify the model.
»Always use a high quality, short USB cable to connect the device to a PC (Use the Siretta approved USB cable)
»You must connect the USB cable directly from the device to the PC and not go through a USB hub.
***IMPORTANT***
»Some antivirus applications have been known to interfere with the software update procedure.
Please disable if you have difculties.
»We have tested our rmware update procedure using Bitdefender and this works as expected.
Please follow the preparation steps below to ensure you are using the correct rmware for
your device and avoid the common mistakes made when updating device rmware.
The procedure steps in this document ensure that you can reliably update your SNYPER
without running into difculties and should prevent rmware update failures.
V1 Hardware Firmware Update
Preparation to begin Firmware Update:
1) Navigate to https://www.siretta.com/software-library/
2) Select ‘SNYPER Firmware Update’ tab
3) Download and install ‘USB Device Drivers’ from the Siretta Software Library to your PC
4) Download and install ‘XFP Programming Tool’ from the Siretta Software Library to your PC
Figure 5. Downloading support tools
Select ‘SNYPER Firmware Update’
Install ‘XFP Progamming Tool’
Next Step...
NOTE: Devices which do not have V2 marking in the model name are V1 hardware.
Preparing for Firmware Update
Install ‘USB Device Drivers’
Download Firmware
Download the latest rmware for the SNYPER from the Siretta Website:
1) Download the correct rmware for your device
(Refer to the silver label on the back of your SNYPER to identify the correct model)
Figure 6. Downloading SNYPER rmware
Next Step...
Preparing the XFP Tool
Preparing the XFP tool to update SNYPER rmware:
1) Unzip the rmware and store the uncompressed le locally on your PC
2) Run XFP and ensure that the ‘Port’ is set to ‘USB’ and ‘Speed’ is set to ‘460800’
3) Within XFP click ‘Browse’ to navigate to the rmware binary on your PC
4) Connect the SNYPER directly to your PC using the approved USB cable
5) Power off the SNYPER
Figure 7. Preparing XFP tool
Set ‘Port’ and ‘Speed’
Select rmware for update
Begin update procedure
Preparing SNYPER for Firmware Update
Figure 8. Power on SNYPER
At this point it is now possible to update the SNYPER rmware:
1) Click ‘Program’ on the XFP tool
2) Press and hold the ‘Back’ button and press the ‘Power’ button momentarily to power on
the SNYPER
3) The SNYPER will enter the special rmware programming mode
4) The SNYPER screen will show ‘Starting Modem’ whilst the modem is being initialised
5) Once the module is connected and powered up the SNYPER screen will show ‘Modem On’
Press and hold back button
Momentarily press power button
Figure 9. Firmware update mode
Next Step...
Firmware Update in Progress
The rmware update procedure will now begin:
1) The XFP application will display ‘Linking’ and then ‘Programming’ in the bottom left corner
2) The progress bar will indicate the update process and how much is remaining
3) Once the rmware update has completed you will be presented with a complete popup box
4) Press and hold the power button to power off the SNYPER and exit programming mode
5) Power on the SNYPER for the unit to re initialise
6) You can now perform surveys as normal
Complete!
Figure 10. Programming in progress
Progress/status bar
Figure 11. Programming complete
V2 Hardware Firmware Update
Preparation to begin Firmware Update:
1) Navigate to https://www.siretta.com/software-library/
2) Select ‘SNYPER Firmware Update (V2)’ tab
3) Download and install ‘USB Device Drivers’ from the Siretta Software Library to your PC
Figure 5. Downloading support tools
Select ‘SNYPER Firmware Update (V2)’
Next Step...
NOTE: Devices which have V2 marking in the model name are V2 hardware.
Preparing for Firmware Update
Install ‘USB Device Drivers’
Download Firmware
Download the latest rmware for the SNYPER from the Siretta Website:
1) Download the correct rmware for your device
(Refer to the silver label on the back of your SNYPER to identify the correct model)
2) Copy the rmware le you have download into a folder on your PC
Figure 6. Downloading SNYPER rmware
Next Step...
Preparing SNYPER for Firmware Update
Figure 8. Power on SNYPER
Follow the steps below to prepare your SNYPER for a rmware update:
1) Connect the SNYPER directly to your PC using the approved USB cable
2) Power off the SNYPER
3) Press and hold the ‘Back’ button and press the ‘Power’ button momentarily to power on the SNYPER
4) The SNYPER screen will show ‘Starting Modem‘ whilst the modem is being initialised
5) Once the module is connected and powered up the SNYPER screen will show ‘Modem On’
6) Check that ‘Telit Serial Diagnostics Interface’ appears in device manager as shown below in gure 10
Press and hold back button
Momentarily press power button
Figure 9. Firmware update mode
Next Step...
Figure 10. Device manager
‘Telit Serial Diagnostics
Interface’ shown here
Run Firmware Update
At this point it is now possible to begin the rmware update:
1) Run the le you have downloaded to start the rmware update
2) It should take around 5 minutes to complete the rmware update
3) Once complete, the programming window will show ‘Completed Successfully’
4) Close the programming window once complete
5) Press and hold the power button to power off the SNYPER and exit programming mode
6) Power on the SNYPER for the unit to re initialise
7) You can now perform surveys as normal
Complete!
Figure 10. Firmware update in progress
Setting the new standard in cellular signal analysers
+44 (0)118 976 9000
www.siretta.com
Siretta Ltd, Basingstoke Road, Spencers Wood, Reading, Berkshire, RG7 1PW, UK Rev 1.0
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

SIRETTA SNYPER-LTE+ Graphyte Network Signal Analyzer User guide

Type
User guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI