WPI Z-LITE User manual

Type
User manual
Z-LITE
WARRANTY
WPI (World Precision Instruments,) warrants to the original purchaser that this equipment, including its
components and parts, shall be free from defects in material and workmanship for a period of 30 days
from the date of receipt. WPI’s obligation under this warranty shall be limited to repair or replacement,
at WPI’s option, of the equipment or defective components or parts upon receipt thereof f.o.b. WPI,
Sarasota, Florida U.S.A. Return of a repaired instrument shall be f.o.b. Sarasota.
The above warranty is contingent upon normal usage and does not cover products which have been
modied without WPI’s approval or which have been subjected to unusual physical or electrical stress
or on which the original identication marks have been removed or altered. The above warranty will
not apply if adjustment, repair or parts replacement is required because of accident, neglect, misuse,
failure of electric power, air conditioning, humidity control, or causes other than normal and ordinary
usage.
To the extent that any of its equipment is furnished by a manufacturer other than WPI, the foregoing
warranty shall be applicable only to the extent of the warranty furnished by such other manufacturer.
This warranty will not apply to appearance terms, such as knobs, handles, dials or the like.
WPI makes no warranty of any kind, express or implied or statutory, including without limitation any
warranties of merchantability and/or tness for a particular purpose. WPI shall not be liable for any
damages, whether direct, indirect, special or consequential arising from a failure of this product to
operate in the manner desired by the user. WPI shall not be liable for any damage to data or property
that may be caused directly or indirectly by use of this product.
Claims and Returns
• Inspect all shipments upon receipt. Missing cartons or obvious damage to cartons should be noted
on the delivery receipt before signing. Concealed loss or damage should be reported at once to the
carrier and an inspection requested. All claims for shortage or damage must be made within 10 days
after receipt of shipment. Claims for lost shipments must be made within 30 days of invoice or other
notication of shipment.
Please save damaged or pilfered cartons until claim settles. In some instances, photographic
documentation may be required. Some items are time sensitive; WPI assumes no extended warranty
or any liability for use beyond the date specied on the container.
• WPI cannot be held responsible for items damaged in shipment en route to us. Please enclose
merchandise in its original shipping container to avoid damage from handling. We recommend that
you insure merchandise when shipping. The customer is responsible for paying shipping expenses
including adequate insurance on all items returned.
• Do not return any goods to WPI without obtaining prior approval and instructions (RMA#) from our
returns department. Goods returned unauthorized or by collect freight may be refused. The RMA#
must be clearly displayed on the outside of the box, or the package will not be accepted. Please
contact the RMA department for a request form.
• Goods returned for repair must be reasonably clean and free of hazardous materials.
• A handling fee is charged for goods returned for exchange or credit. This fee may add up to 25% of
the sale price depending on the condition of the item. Goods ordered in error are also subject to the
handling fee.
• Equipment which was built as a special order cannot be returned.
• Always refer to the RMA# when contacting WPI to obtain a status of your returned item.
• For any other issues regarding a claim or return, please contact the RMA department
Warning: This equipment is not designed or intended for use on humans.
WORLD
PRECISION
INSTRUMENTS
Z-LITE
High intensity source for ber optic illumination
Serial No._____________________
www.wpiinc.com
INSTRUCTION MANUAL
113020
USA
175 Sarasota Center Blvd., Sarasota FL 34240-9258
Tel: 941-371-1003 • Fax: 941-377-5428 • E-mail: [email protected]
UK
1 Hunting Gate, Hitchin, Hertfordshire SG4 0TJ
Tel: 44 (0)1462 424700 • Fax: 44 (0)1462 424701 • E-mail: [email protected]
Germany
Pngstweide 16, D-61169 Friedberg (Hessen), Germany
Tel: +49 (0)6031 67708-0 • Fax: +49 (0)6031 67708-80 • E-mail: wpide@wpi-europe.
com
China & Hong Kong
WPI Shanghai Trading Co., Ltd.
Rm 27A, Liangfeng Building, No 8, Dongfang Road, Pudong New District, Shanghai, PRC
Tel: +86 21 6888 5517 • 400 688 5517 • E-mail:[email protected]
Brazil
Av. Conselheiro Nébias, 756 sala 2611, Santos-CEP: 11045-002, São Paulo Brazil
Tel: (013) 406-29703 • E-mail: [email protected]
Internet
www.wpiinc.com • www.wpi-europe.com • www.wpiinc.net
Z-LITE
INTRODUCTION
The Z-LITE Fiber Optic Illuminator provides reliable, uninterrupted
high-intensity light for microscopes. Use the rotary dimmer switch to
control the halogen light source for a continuous range of subdued
or concentrated lighting. The Z-LITE is available in the following
congurations:
Z-LITE – 115V, 60Hz Fiber optic illuminator, beige
Z-LITE-Z – 230V, 60Hz Fiber optic illuminator, black
Z-LITE-186 – Z-LITE with bifurcated light guides
Z-LITE-Z186 – Z-LITE-Z with bifurcated light guides
Common accessories include a ring light and single or bifurcated exible
light guides to direct the light beam precisely.
The unit is shipped with a lamp that produces a color temperature of
3200°K. Forced air cooling prolongs the lamp life. The EJA bulb can be
used as a replacement lamp. When you open the front panel, a safety
switch automatically shuts o the power.
Unpacking
Upon receipt of this instrument, make a thorough inspection of the
contents and check for possible damage. Missing cartons or obvious
damage to cartons should be noted on the delivery receipt before
signing. Concealed damage should be reported at once to the carrier and
an inspection requested. Please read the section entitled “Claims and
Returns.” Please contact WPI Customer Service if any parts are missing at
941.371.1003 or [email protected].
Returns: Do not return any goods to
WPI without obtaining prior approval
(RMA # required) and instructions
from WPI’s Returns Department.
Goods returned (unauthorized) by
collect freight may be refused. If a
return shipment is necessary, use the
original container, if possible. If the
original container is not available, use
a suitable substitute that is rigid and
of adequate size. Wrap the instrument
in paper or plastic surrounded with at least 100mm (four inches) of shock
absorbing material. For further details, please read the section entitled
“Claims and Returns.”
OPERATING INSTRUCTIONS
1. Plug the illuminator’s AC power cord into a grounded receptacle.
2. Turn the rotary dimmer knob (large black knob on the front panel) in
a clockwise direction to increase the light intensity. A click indicates
that the power is ON. When you rotate the knob to its extreme clock-
wise position, the light is at its brightest. Rotating the knob counter-
clockwise decreases the intensity of the light and also shuts o the
power.
Using Light Guides
The metal light guide port on the face of the Z-LITE (bottom left) has
an inside diameter of 5/8” to accommodate ber light guides. See
ACCESSORIES. Insert the desired light guide into the connection port and
tighten the knurled light guide knobs to hold the guide rmly.
Replacing the Bulb
1. Shut o the power and remove
the AC power cord from the outlet.
Although the power is automatically
shut o by a safety switch when the
front panel is opened, removing the
AC cord is a precautionary measure.
2. Loosen the knurled case knob on
the top of the case until the front panel opens.
3. The bulb release lever is located on the left side of the bulb. Push this
lever upward. The lever pushes the bulb which slides forward out of
the cradle.
4. Gently pull the socket away from the back of the bulb.
5. To insert a new bulb, push the bulb release lever down into its origi-
nal position. Align the two pins on the lamp with the two holes in the
socket. Firmly press the bulb into the socket until the pins are fully
seated. Then, push the bulb back until its cradle.
6. Close the front panel, re-tighten the knurled case knob, plug the AC
power cord into the power outlet.
Changing the Fuse
This unit is equipped with a fuse. The fuse will blow if a problem occurs. If
this happens, wait until the lamp cools down before attempting to replace
the fuse. If the fuse continues to blow, there is a short and the problem
must be xed by a qualied technician. To change the fuse:
1. Insert a small, at-head screwdriver
into the recess on top of the fuse
housing that is located on the back
of the unit. The fuse casing pops
out.
2. Remove the casing and the fuse.
3. Position a new fuse in the casing and reinstall the casing.
TROUBLESHOOTING
If the illuminator will not operate:
1. Check the connections to the lamp. Loosen the
case knob on the top front of the instrument to open the front panel.
Verify that the lamp is properly seated and in full contact with the
lamp holder contact springs. Close the panel and re-tighten the case
knob.
2. Check the fuse. See Changing the Fuse.
SPECIFICATIONS
Lamp ................................................................................................21V/150W quartz halogen
Fuse .........................................................................................................3A Fast, 5mm x 20mm
Maximum Temperature .................................................................................................3200°K
Size ............................................................................... 200 x 200 x 140mm (7.9 x 7.9 x 5.5“)
Power .............................................................................................. 115/230V AC, 50/60Hz, 3A
Weight ...................................................................................................................5.7kg (12.6 lb.)
ORDERING INFORMATION
Z-LITE 115V, 60Hz Fiber optic illuminator, beige
Z-LITE-Z 230V, 60Hz Fiber optic illuminator, black
Z-LITE-186 Z-LITE with bifurcated light guides
Z-LITE-Z186 Z-LITE-Z with bifurcated light guides
Light Guides and Accessories
500186 Bifurcated Light Guide (with lenses)
R-8-8-WPI-01 Ring Light Guide for PZM (Requires adapter #13338 for use
with PZM stereo microscopes)
13338 Ring Light Adapter (48mm Ø) for PZM, PZMII, PZMIII
502015 Ring Light Adapter for PZMIV
5475 Adapter for SMA-terminated Fiber Optic Cables
EJA* Replacement Bulb, 21V, 150W, 40 hour lamp, 3350K
EKE Replacement Bulb, 21V, 150W, 200 hour lamp, 3250K
*The Z-LITE is supplied with an EKE 200 hour lamp. The recommended EJA is brighter, though it
has a shorter life.
Bulb Release
Lever
Socket
Light Guide Port Rotary Dimmer Knob
Case Knob
Light Guide Knobs
  • Page 1 1