urban ambiance UQL9000 Installation guide

Type
Installation guide

Urban ambiance UQL9000 is a ceiling fan with dimmable LED lights, controlled by a remote control or wall switch. It features five fan speeds, adjustable airflow direction, and a built-in safety cable. The fan is suitable for use in damp locations and can be mounted on a standard ceiling fan-rated outlet box or support structure. With its sleek design and energy-efficient features, the UQL9000 is a stylish and functional addition to any room.

Urban ambiance UQL9000 is a ceiling fan with dimmable LED lights, controlled by a remote control or wall switch. It features five fan speeds, adjustable airflow direction, and a built-in safety cable. The fan is suitable for use in damp locations and can be mounted on a standard ceiling fan-rated outlet box or support structure. With its sleek design and energy-efficient features, the UQL9000 is a stylish and functional addition to any room.

1 of 5
Light SourceTools Required
BULB BASETYPE
MEDIUM (E26)
5 BULBS REQUIRED
BULB INCLUDED
LED 8W
BULB SHAPE
TYPE S
Fixture Hanging Height
24” Dia.
11.5
Package Contents
Remote Control
Transmitter X 1
O
Batteries
X 1
P
Mounting Bracket
X 1
Q
RScrew
x 2
PARTS BAG 3
XRing
x 1
TFixture Body
x 1
UFan Blade
X 1
WBlade Assembly
Nut X 1
VLED Bulb
x 5
Preparation: Identify and inspect all parts before beginning
installation. Check package content list and diagrams below to
ensure all parts are present. If any parts are missing or damaged,
do not attempt to assemble, install, or operate the fixture.
Missing Parts? Contact your original place of purchase.
Warnings and Cautions
READ AND SAVE THESE INSTRUCTIONS
1) Turn off electricity at circuit breaker or main fuse box before installation. Consult a licensed electrician if in doubt.
2) These instructions are provided for your safety. It is very important you read them completely before installing the fixture. We strongly
recommend that a licensed, professional electrician perform the installation.
3) WARNING- To Reduce The risk of personal injury, Do not bend the blades when installing the fan, or cleaning the fan. Do not insert foreign
objects in between rotating fan blades.
4) WARNING- To Reduce The Risk Of Fire, Electric Shock, Or Personal Injury, Mount To Outlet Box Marked (Acceptable for Fan Support of
22.7kg(50lbs) or less) And Use Mounting Screws Provided With The Outlet Box.
5) All set screws must be checked, and retightened where necessary, before installation.
6) After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on
one side of the outlet box and the ungrounded conductor on the other side of the outlet box.
7) Disconnect fixture from the power source before replacing bulbs or cleaning. Make sure the bulbs are given sufficient time to cool be before
removing.
8) Suitable for use with solid-state speed controls.
9)Use Only With Light Kits Marked Suitable For Use In Damp Locations
10) This unit weighs 5.2KG.
Hanger Frame x 1
(Pre-assembled to
Fixture Body)
A
Wood Screw
x 2
B
Flat Washer
x 4
CLock Washer
x 4
D
Spring Washer
x 4
E
Wire Connector
x 3
F
PARTS BAG 1
Machine screw
x 2
H
Mounting screw x 4
(Pre-assembled to
Fixture Body)
GSAllen Wrench
x 1
Wall Anchor
x 1
J
Screw
x 1
Flat Washer
x 1
I
Set Screw
x 1
K
Fastener
x 1
L M
PARTS BAG 2
Spring Washer
x 1
N
Installation Instructions: UQL9000
www.urbanambiance.com
2 of 5
STEP 1
STEP 2
Ceiling Bracket Fan Blade Install Cable Wiring
Table of
Contents
STEP 1 STEP 2 STEP 3 STEP 4 STEP5
Use wood screws
When securing to support
structure with approved
electrical outlet box. Drill
9/64” pilot holes.
Use machine screws
when securing to existing
ceiling fan-rated outlet box.
that supports of 50 lbs
(22.72 kg) or less.
Fixture Body
www.urbanambiance.com
3 of 5
A. Pass the cable through one hole on the Fastener first and then turn back to pass the cable through another hole on the Fastener. Make a
small loop that is just large enough for the Screw. Once the loop size is determined, thread the Set Screw into the Fastener and hand
tighten until snug.
B. Place the Spring Washer and the Flat Washer onto the Screw and pass the Screw through the Cable loop. Thread the Screw into the
ceiling, structural support close to the Hanger Frame. Hand tighten until snug to secure the cable.
Note: If you would like to install the cable to concrete ceiling, Wall Anchors will be required. Using a 5/16-inch drill bit (not included), drill
pilot holes at marked locations.
STEP 3-SAFETY CABLE
STEP 4
Making the wire connections using the receiver, for use with the remote control
A. Making the Wire Connections
1. Connect fixture wires with label “Light L” together;
2. Connect fixture wires with label “N” together;
3. Connect fixture wires with label “ Motor L” togther.
B. Making the Wire Connections
1. Wrap bare or green ground wire around green ground screw on the crossbar, no less than 2 inches from the end of the wire. Tighten the
green ground screw.
2. Use standard wire connectors (not included) to make all wire
connections. Twist connectors until wires are tightly joined together. Wrap each connection with approved electrical tape and carefully stuff
all the connected wires into outlet box.
Note: If the electrical wire is going to be cut shorter than provided you will need to identify the "L" line wire and the "N" neutral wire before
you cut the excess wire off. One is labeled N and the other labeled L. To do this separate the "L" line wire and the "N" neutral wire as far
as you need to. Re-label the wire near where you want to make the cut. Be sure to mark the wire on the side of the fixture and not on the
excess wire being cut and removed.
Blue wire from fixture
identified with the Label “LIGHT L”
White wire from fixture
identified with the Label “N”
Black wire from fixture
identified with the Label “MOTOR L
AC L
AC N
White wire from outlet box
Black wire from outlet box (or Red)
Ground wire from Fixture
Bare, or Green
Ground wire
from outlet box
Green Ground Screw on the Crossbar
Ground wire from Hanger Frame
ON ON DIP
1 2 3 4
Black Wire from controller
with the Label “MOTOR L
White Wire from controller
with the Label “N
White Wire from current-limiting
with the Label “N
Black Wire from current-limiting
with the Label “LIGHT L
Blue Wire from controller
with the Label “LIGHT L
Red Wire
www.urbanambiance.com
4 of 5
Making the wire connections without the received, the fan and light will be controlled by wall switches only.
a. Making the Wire Connections,
1. Remove the current-limiting from the receiver.
2. Wrap bare or green ground wire around green ground screw on the crossbar, no less than 2 inches from the end of the wire. Tighten the green
ground screw.
3. Use standard wire connectors (not included) to make all wire connections. Twist connectors until wires are tightly joined together. Wrap each
connection with approved electrical tape and carefully stuff all the connected wires into outlet box.
Note: If the electrical wire is going to be cut shorter than provided you will need to identify the "L" line wire and the "N" neutral wire before
you cut the excess wire off. One is labeled N and the other labeled L. To do this separate the "L" line wire and the "N" neutral wire as far as
you need to. Re-label the wire near where you want to make the cut. Be sure to mark the wire on the side of the fixture and not on the excess
wire being cut and removed.
White wire
from outlet box
Black wire from
outlet box (or Red)
Ground wire from Fixture
Bare, or Green
Ground wire
from outlet box
Green Ground Screw on the Crossbar
Ground wire from Hanger Frame
Red wire from
current-limiting
Current-limiting
Black Wire from current-limiting
with the Label “LIGHT L
White Wire from current-limiting with the Label “N
Blue wire from fixture
identified with the
Label “LIGHT L”
Black wire from fixture identified with the Label “MOTOR L”
White wire from fixture identified with the Label “N”
Warning: If you would like to use wall switch to control the light
and fan, please refer to the switch installation instructions.
STEP 5
A. Insert the LED bulbs into the socket
and thread in place. NOTE: This product is equipped with a
maximum 70W current limiter. The total
lamp wattage cannot exceed 70W or the
lamp will not light.
www.urbanambiance.com
5 of 5
Instructions for fan and light remote control.
1. Setting up the remote
The wireless control is designed to operate both the light and
speed of the fan. The remote uses a 9V battery. Remove the
remote's back cover and insert the battery Please make sure
the battery is inserted correctly.
The code for the controller and remote must be the same. You
can manually adjust the code as shown to the right.
2. Operating instructions
a. Turn on power and press (light) key on the remote to turn on the lights
Press the key again to turn off. Long press this button, the bulb will be dimmable.
b.(Four speed buttons) These are the four keys for adjusting fan speed
Warning: changes or modifications to this unit not expressly
approved by the party responsible for compliance could void
user's authority to operate the equipment.
STEP 6
Install Remote Control Transmitter Wall Bracket (If being used)
a. Place Remote Control Mounting Bracket on the wall in desired location and
use two screws supplied to attach to the wall.
b. Insert supplied battery in remote control in a position that is shown inside the
remote control cover.
Wall
STEP 9
How to Operate Your Ceiling Fan
a. If airflow is desired in the opposite direction, turn the fan off and wait for the
blades to stop turning. Then slide the reverse switch on top of motor assembly
to the opposite position and turn fan on again.
Note: Push the reverse switch to Left or Right completely
Reversing
Switch
Rotation Direction
Reverse Switch Information
Season Switch Position
Summer Counterclockwise Left
Winter Clockwise Right
ON DIP
1 2 3 4
Remove the rubber
stopper from the
controller. Then the
code must be the
same for both
controller and remote.
Place the previously
removed rubber
stopper back in the
controller.
Batteries
6F22 9V
Antenna
AC 120V
Controller
Remote
www.urbanambiance.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

urban ambiance UQL9000 Installation guide

Type
Installation guide

Urban ambiance UQL9000 is a ceiling fan with dimmable LED lights, controlled by a remote control or wall switch. It features five fan speeds, adjustable airflow direction, and a built-in safety cable. The fan is suitable for use in damp locations and can be mounted on a standard ceiling fan-rated outlet box or support structure. With its sleek design and energy-efficient features, the UQL9000 is a stylish and functional addition to any room.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI