DISPLAY PANEL
Operation
1. Display: the display indicates the room temperature in Celsius. If no function button is pressed,
the display will turn dark after 5-seconds.
2. Mist Button: press the Mist Button to choose between levels 1~5. Level 5 is the highest power
working mode. The default mist level is 5.
3. Humidity Button: press the Humidity Button and it will increase 5%RH (relative humidity). If you
want to set a target humidity, it has a range from 40%-90%RH. Continue to touch until max 90%.
Cycle through if you go past your desired RH. When the %RH reaches your target humidity, the
fogger will stop. The fan will stop after 10-seconds, along with the Anion function.
4. Timer Button: the timer can be selected in 1-hour increments, from1-12 hours. Once you
choose your setting, after 3-seconds, it will turn to timer mode. Once the duration is complete,
the machine will auto turn off. Touch the Power Button to restart.
5. Anion Button: the Anion function creates negative ions, which cause floating particulates (dust,
dander, allergens, pathogens) in the air to cling together and drop to the floor. If the disinfectant
runs low, the Anion function will auto turn off. Once the tank is refilled, the Anion function will
work again.
6. Auto/Sleep Button: touch sleep to start sleep mode, touch any button to wake up.
Disinfectant Shortage
If the disinfectant runs low, the fog will stop, and the fan will stop after 10-seconds. The water
shortage signal will flash for 0.5 seconds, sound a beep 3-times, then turn off after 15-seconds.
The water level light will turn off as well.
Problem
Light off, fan not
working, no mist
Power not
connected, or a
problem
Light on, fan not
working, no mist
Too much water in
the base.
Pour out some water from the
base and restart
Atomizer covered
by ‘furring’
Clean the ‘furring’ from the
atomizer, and replace with new
disinfectant
Valve is stuck, or
incorrect water tank
placement
Clean valve and place the water
tank to the correct position