The viruserv VF-4A-FOG is a versatile device that can be used for various purposes. It features 5 mist levels, allowing you to adjust the intensity of the mist output. It also has a built-in humidistat, enabling you to set a target humidity level between 40% and 90%RH, ensuring optimal humidity levels in your space. Additionally, the device comes with a timer function, allowing you to set it to run for a specific duration of up to 12 hours.

The viruserv VF-4A-FOG is a versatile device that can be used for various purposes. It features 5 mist levels, allowing you to adjust the intensity of the mist output. It also has a built-in humidistat, enabling you to set a target humidity level between 40% and 90%RH, ensuring optimal humidity levels in your space. Additionally, the device comes with a timer function, allowing you to set it to run for a specific duration of up to 12 hours.

User Manual
Model Name: VF Nimbus
Model Number: VF-4A-FOG
Filling the VF Nimbus (VF-4A-FOG)
1. Unplug the unit from the wall outlet. Open the
water tank lid and fill with water. Max capacity is
6-gallons. Use two EfferSan tablets per gallon
of water. Let the tablets fully dissolve (4-5 minutes)
before tuning on.
2. Flip the lid back down, then plug the power cord
into the outlet.
3. Press the power button. The power light will be
green or blue.
4. When the disinfectant runs low, the machine will
auto turn off. At that point, the water shortage light
will be on (red light). Start at Step 1 to refill.
Part List
DISPLAY PANEL
Operation
1. Display: the display indicates the room temperature in Celsius. If no function button is pressed,
the display will turn dark after 5-seconds.
2. Mist Button: press the Mist Button to choose between levels 1~5. Level 5 is the highest power
working mode. The default mist level is 5.
3. Humidity Button: press the Humidity Button and it will increase 5%RH (relative humidity). If you
want to set a target humidity, it has a range from 40%-90%RH. Continue to touch until max 90%.
Cycle through if you go past your desired RH. When the %RH reaches your target humidity, the
fogger will stop. The fan will stop after 10-seconds, along with the Anion function.
4. Timer Button: the timer can be selected in 1-hour increments, from1-12 hours. Once you
choose your setting, after 3-seconds, it will turn to timer mode. Once the duration is complete,
the machine will auto turn off. Touch the Power Button to restart.
5. Anion Button: the Anion function creates negative ions, which cause floating particulates (dust,
dander, allergens, pathogens) in the air to cling together and drop to the floor. If the disinfectant
runs low, the Anion function will auto turn off. Once the tank is refilled, the Anion function will
work again.
6. Auto/Sleep Button: touch sleep to start sleep mode, touch any button to wake up.
Disinfectant Shortage
If the disinfectant runs low, the fog will stop, and the fan will stop after 10-seconds. The water
shortage signal will flash for 0.5 seconds, sound a beep 3-times, then turn off after 15-seconds.
The water level light will turn off as well.
Problem
Problem
Reason
Solve
Light off, fan not
working, no mist
Power not
connected, or a
problem
Try another power outlet
Light on, fan not
working, no mist
Too much water in
the base.
Pour out some water from the
base and restart
Mist small
Atomizer covered
by ‘furring’
Clean the ‘furring’ from the
atomizer, and replace with new
disinfectant
Water can-not reach base
Valve is stuck, or
incorrect water tank
placement
Clean valve and place the water
tank to the correct position
  • Page 1 1
  • Page 2 2
  • Page 3 3

viruserv VF-4A-FOG User manual

Type
User manual

The viruserv VF-4A-FOG is a versatile device that can be used for various purposes. It features 5 mist levels, allowing you to adjust the intensity of the mist output. It also has a built-in humidistat, enabling you to set a target humidity level between 40% and 90%RH, ensuring optimal humidity levels in your space. Additionally, the device comes with a timer function, allowing you to set it to run for a specific duration of up to 12 hours.