Estap SRV47U80_03M1P_TR Datasheet

Category
Racks
Type
Datasheet

This manual is also suitable for

3
• CompatiblewithallEIA-310
compliant19”equipment.All
typeofservers,brandswill
physicallytinServerMAX
servercabinet.
• Bottomplatehasanextra
perforatedplatetoprevent
insectsormicefromreaching
thecables.
• Efcientpassiveaircirculation
• NumberedUpositionsfacilitate
easyinstallationofrackmounted
equipment.
ServerMAX freestanding
3
ServerMAX free standing
4
600x1000-800x1000
600x1000*
800x1000*
ServerMAX free standing enclosure
26U 36U 42U 47U
 42U 47U
•19”
•HIGHQUALITYPRODUCTS
•COMPLIMENTSYOURDECORAND
ENVIRONMENT
•SECUREANDSTURDY
•EASYTOMAINTAIN:LARGEINNER
VOLUME
•HIGHSECURITYFORUNAUTHORIZED
ACCESS
•STRONGPROTECTIONAGAINST
PHYSICALDAMAGE
•EXCELLENTPASSIVEAIRVENTILATION
ServerMAX protects your
technological investments
*Pleasecheckdrawingpagesforcabinetsizes.
5
ServerMAX free standing
KEY FEATURES
Adjustable mounting depth:19”mountingangles
areadjustableindepthforvariousmountsforadjustable
depthdistance,pleaselookatdrawingpages.
Bottom plate:ttedwithanadditionalplateto
preventinsects/vermin.Ifnecessaryaltermaybe
integratedtopreventdustinltration.
Bottomplateiscompletewithpre-punchedremovable
sections:whenairowcomesfromtheoor,these
sectionscanberemovedtoprovideefcientairow
insidethecabinet.
Reversible doors: Frontandreardoorsmaybe
detachedandreversedtoallowthedoortoopenfrom
therearofthecabinet.
Side doors are split in two:Frontsectionusedto
accessthecabinet;additionalsmallersectionsecured
insidethecabinet.Ifadditionalventilationisnecessaryit
canbedemandedasvented.Themaininnerstripofthis
panelisdesignedforthehousingofcablesandpower
strips.
Numbered “U” positionsfacilitateeasyinstallation
forrackmountedequipment.
Vertical mounting rails withsquareholes;
adjustableindepth.
SERVERMAXFREESTANDINGENCLOSURESFOR 600x1000-800x1000600x1000-800x1000
STANDARD DIMENSIONS:
Heights:26U,36U,42U,47U
Width:600mm
Depth:1000mm
Heights:42U,47U
Width:780mm
Depth:1000mm
LOAD CARRYING CAPACITY:1000kg
COLOUR:
RAL9005black
RAL7035lightgrey
STANDARDS:
ISO9001:2008QualityManagementSystems
ISO14001:2004EnvironmentalManagementSystem
19”mountingtoIEC297-1
EN61587-1mechanicalstructures(cabinetsfor
electronicequipment)
OverallcabinetdimensionsforIEC297-2
6
ServerMAX free standing
600x1000-800x1000
Optional plexi front door: Maybeusedinsteadof
ventedfrontdoor.
All in one:ServerMAXincludes;casters,doors,ground
studs,levellingfeet,roof,bottom,sidepanels,C-rails,tiltbars,
unloadedfantray.
Optimized depth: 1000mm.Todayandnextgeneration
installationofservers,forpowerdistributionandcable
management.1000mmistheoptimumdepthforcomfort
cabling,housingserverandgainingspaceindatacenters.
Fixing to oor:ServerMAXcanbeeasilyxedtothe
oorwhennecessary.Aoorxingkitisusedforthis
purpose.Pleaseseeaccessoriesforoorxingkit.
Efcient passive ventilation: Newgenerationservers
andnetworkingproductsneedadequateventilationto
operateefciently.ServerMAXservercabinetsprovide
efcientpassiveventilationbecauseofitsventedstructureof
frontandreardoors.Frontandreardoorshavemaximum
perforation(%63)patternsforhigh-densitycoolingthatmeets
orexceedsservermanufacturer’sventilationrequirements.
There is a fan tray on roof: Removableeasilyfrom
thetop.Whenthemaintanenceoffansarerequired,itcanbe
reacheddirectlyfromthetopwithouttouchinganymounted
deviceorservers.
Itispossibletoattachalterontopoftheserverfanunit.
Generous cable accessholesareprovidedintheroof
andbase.Oneontop,oneonbottomholesarespecialESTAP
stylecableentries;slidingtypewithrubberedges.
7
ServerMAX free standing
FEATURES 600x1000-800x1000
Quick release side doors: Duringinstallationandwhile
conductingroutinemaintenanceofinstalledequipment,itis
oftenadvantageoustoremovethesidepanels.Quickrelease
slamlatchesandlocksonthesidepanelsallowforquickand
easyaccess.
Double opening rear doors improveaccessand
serviceabilitytorearofrackmountedequipment.Thesplit
reardoorshelptomaximizeoorspace.Only390mmfor
W=780mmcabinetsofclearanceisrequiredbehindthe
enclosuretoallowfordoorswing.
D= 200 mm extention unit:Ifdeeperequipment
isloadedintoServerMAXcabinetsrequiringadditional
depthforcableradius,cablebundles,PDUhousingetc,a
D=200mmextensionunitmaybeinstalledtoServerMAX
cabinets:thereardoorisremovedandreinstalledontothe
extensionunit.(Pleaseseediagramsonpages18-19)
Expansion: ServerMAXenclosurescanbeeasily
expandedtocreatecompleterowsofenclosureswithout
sidepanels.Withaproperbayingkit(pleaseseeaccessories)
allcabinetsarebayedeasilyandquickly.
Welded: Bottomandroofofthecabinetiscompletely
weldedandaclosedstructure.Sturdyandrugged,itprotects
againstphysicalelementslikedust,insects.
Lockable doors and side panels: Frontandrear
doorsarelockableusinga3pointlockingmechanism.
Ahandle-stylelockingsystemprovidesincreasedsecurityto
preventunauthorizedaccess.Alldoorsandsidepanelsare
onlyaccessiblewithakeyprovidedbyServerMAX.
Stability: Heavydutyframedesign,2mmmountingrails,
angles,heavydutytypecastorgroupprovide1000kgload
rating.
Anti-tilt bars: Asstandard,ServerMAXisttedwith
2slidingtypetiltbarstomakethecabinetstableinweight
center.Whenevertheserversaremovedout,tiltbarsare
drawnouttocounter-balancethecabinetsweightcenter.
8
ServerMAX free standing
FEATURES 600x1000-800x1000
Grounding: Allpartsarettedwithgroundingstudsto
provideelectricalcontinuity.
Heavy duty vertical frames: Insteadof4ea.vertical
proles,ServerMAXcabinetsare6ea.(3ea.inleft+3ea.inright)
mainverticalprolesthatgivesextrastabilityforheavyloads.
More C rails:Insteadof6ea.thereare8horizontalCrails
indepthforextrastability.(42U,47U)
Reinforced bottom:Bottomsarereinforcedwith
horizontalprolesinwidthanddepthforextrastability.
Rounded aesthetic monoblok front door: Front
doorisaheavydutytypemonoblockperforatedandwelded
structure.It’sshapeisroundedinfronttoenhancethe
aesthetics.
Surface treatment:Fosfatcoating,oilremoveand
passivation.
Material thicknesses: Roof,bottom,verticalmainframes,
1,5mmC-rails,19”mountingangles,prolesandallframes
are2mmthickness.Sturdysteelconstruction.
Paint:Electrostaticpowdercoating.
Easy to dismantle and assembly:Therigidlywelded
frameconstructioncanbedismantledandassembledeasily
withoutanyspecialtools.Thus,narrowdoors,staircasesand
liftsarenoproblem.
Special cable entry on top and bottom case:
Bottomplateandtopcasehaveaspecialcableentry,
completelyclosed,slidingtypewithrubberedges.
Cablesareenteredandxed.
Housing for cabling: Thecabinetitselfhasenough
housingforverticalcablemanagementatback.For600x1000
cabinet,cableringsareusedforcablemanagement.
For780x1000cabinetstherearespecialverticalcable
managementpanelsofIeft&rightwithcoverplateforhiding
andprotectingthecables.Theseallowcustomerstoeasily
route,manageandaccesslargenumbersofdatacableseven
whileanenclosureisloadedwithrackmountequipmentand
bayedinarow.
Power/energy distribution: Rearpowerdistribution
housingatbackofthecabinetprovideeasyaccesstomultiple
receptacles.Verticalpowerdistributionstripscaneasily
bemountedinthatspace.Thishousingneverinterfere
withequipmentortakesanyvaluable“U”space.Providing
increasedaccessibilitytoreceptaclesallowscustomersto
supportmorepowercordswithintheenclosure.
Powerstripsarethelengthofcabinets:26U,36U,42U,47U.
9
ServerMAX free standing
ADDITIONALFEATURESFOR 800x1000mm
ServerMAX Width=780 mm cabinet has all
features mentioned before. Plus these additional
features.
Left and right front panel:
Frontpanelscanbeusedto
hideunwantedviewsofcables.Ifservercabinetisadditionally
usedfornetworkinginthefront,cablemanagementisneeded:
Estapcableringscanbeusedtoattachthispanelandsecure
cables.Accessholesallowthepatchcordtoreachtherearof
cabinet.
Vertical cable management panels canbeusedat
rearofthecabinetforprofessionalcablingandtohidethe
powercables.
Extra Housing space for cabling and power
distribution:
Thisextraspaceprovideshousingforthe
verticalcablemanagementpanelsandtheverticalpower
strips.
More Volume Width=780 mm:
Provides more efcient
cooling and more
professional cabling
10
ServerMAX free standing
SELECTIONSTEPSFOR 600x1000
STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
InadditiontoEstapproductpartnumbers,theoptionsmentionedonthenextpagearetosupplytheright
denitiontomeetyourrequirements.
Eachwallmountedandfreestandingenclosuresectioninthecatalogue,hasa‘’Mainpartnumberstructure’’and
‘’Options’’sections.
Thebelowexampleexplainshowtoselecttherightoptionsforyourneeds.
The product part number has the below structure for ServerMAX W=600 mm:
Productrangename + Uheight(HHU)
The product options have the below structure:
Colouroption(MX) + Frontdooroption(FX) + Reardooroption(RX)
HOW TO SELECT THE OPTIONS
Step1
Pleasechooseproductpartnumber.
Forexample:SRV42U (Width=600 mm)
Step2
Pleasechoosethecolourfromthetableandplaceitafterthepartnumber.
Forexample:SRV42U - M01 (MX=LookattheMXcolouroptionsonthenextpage)
Step3
PleasechoosethefrontdoorfromthetableandplaceitafterMXcolour.
Forexample:SRV42U - M01 - F15 (FX=lookattheFXfrontdooroptionsonthenextpage)
Step4
PleasechoosethereardoorfromthetableandplaceitafterFXfrontdooroption.
Forexample:SRV42U - M01 - F15 - R07 (RX=lookattheRXreardooroptionsonthenextpage)
11
ServerMAX free standing
PARTNUMBERDEFINITIONFOR 600x1000
H=Enclosureheight
FX***
Front door options
RX***
Rear door option
Back view
SRV - HHU
MX - FX - RX
Product
range
ServerMAX
SRV
SRV
U
height
HHU
26U
36U
42U
47U
+
Colour
options
MX
M01
M02
+ +
Front
door
options
FX
F14**
F15
R07*
Rear
door
options
RX
R07*
SRV :ServerMAXproductrange(W=600mm)
HHU :“U”height
WD :600x1000mm
OPTIONS
MAIN PART NUMBER STRUCTURE
R07*
R07*
MX : Colouroptions
M01=RAL9005black
M02=RAL7035lightgrey
FX :Frontdooroptions
F14**=Singleopening,monoblock,welded,curved%63
perforateddoor,3pointhandledlocking
F15=Singleopening,monoblock,welded,curvedplexiglass
door,3pointhandledlocking
RX : Reardooroption
q R07*=Doubleopening%63perforateddoorwith
completemetalframe,3pointhandledlocking
Front view
F14**
F15
*R07isthestandardreardoor.
**F14isthestandardfrontdoor.
***F14,F15R07canbeusedasfrontorreardoor.
600
H
600
H
Front view
600
H
Front view
600
H
12
ServerMAX free standing
Part
number
Product
denition
(mm)
U
Size
Width:
overall
(mm)
Depth:
overall
(mm)
Depth: max
mounting
prole (mm)
Height:
vertical
mounting
prole (mm)
Height:
without
levelling feet
(mm)
Height:
with casters
(mm)
SRV26U
26U 600x1000 mm 26 600 1000 740 1179 1291 1338
SRV36U
36U 600x1000 mm 36 600 1000 740 1623 1735 1782
SRV42U
42U 600x1000 mm 42 600 1000 740 1890 2002 2049
SRV47U
47U 600x1000 mm 47 600 1000 740 2112 2224 2271
ServerMAX cabinets 19” 600 x 1000 mm
TECHNICALDRAWINGSFOR 600x1000-26U/36U/42U/47U
Exploded view
*R07isthestandardreardoor.
**F14isthestandardfrontdoor.
***F14,F15,R07canbeusedasfrontorreardoor.
F14**/***
F15***
R07*/***
13
ServerMAX free standing
TECHNICALDRAWINGSFOR 600x1000-26U/36U/42U/47U
H=Enclosureheight
565
180
200
140 140
906
200
200
30
1000
(Min 158)
184
(Min 795)
740
(Min 25)
56
Bottom view Mounting profile
Top view Iso view
Back viewSide viewFront view
H
600
200
600 1000
Front view
Front view
Front view
12
47
R07*
F14**
F15
*R07isthestandardreardoor.
**F14isthestandardfrontdoor.
600
H
600
H
600
H
14
ServerMAX free standing
PARTNUMBERDEFINITIONFOR 800x1000
STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
InadditiontoEstapproductpartnumbers,theoptionsmentionedonthenextpagearetosupplytheright
denitiontomeetyourrequirements.
Eachwallmountedandfreestandingenclosuresectioninthecatalogue,hasa‘’Mainpartnumberstructure’’and
‘’Options’’sections.
Thebelowexampleexplainshowtoselecttherightoptionsforyourneeds.
The product part number has the below structure for ServerMAX W=780 mm:
Productrangename + Uheight(HHU) + Width(WW,D=1000mm)
The product options have the below structure:
Colouroption(MX) + Frontdooroption(FX) + Reardooroption(RX)
HOW TO SELECT THE OPTIONS
Step1
Pleasechooseproductpartnumber.
Forexample:SRV42U8 (Width=780 mm)
Step2
Pleasechoosethecolourfromthetableandplaceitafterthepartnumber.
Forexample:SRV42U8 - M01 (MX=LookattheMXcolouroptionsonthenextpage)
Step3
PleasechoosethefrontdoorfromthetableandplaceitafterMXcolour.
Forexample:SRV42U8 - M01 - F16 (FX=LookattheFXfrontdooroptionsonthenextpage)
Step4
PleasechoosethereardoorfromthetableandplaceitafterFXfrontdooroption.
Forexample:SRV42U8 - M01 - F16 - R08 (RX=LookattheRXreardooroptionsonthenextpage)
15
ServerMAX free standing
PARTNUMBERDEFINITIONFOR 800x1000
H=Enclosureheight
FX***
Front door options
RX***
Rear door option
Back view
SRV :ServerMAXproductrange
HHU :“U”height
WW :Width(W=780mm)
OPTIONS
MAIN PART NUMBER STRUCTURE
MX :Colouroptions
M01=RAL9005black
M02=RAL7035lightgrey
FX :Frontdooroptions
F16**=Singleopening,monoblock,welded,curved%63
perforateddoor,3pointhandledlocking
F17=Singleopening,welded,curvedplexiglassdoor,
3pointhandledlocking
RX :Reardooroption
R08*=Doubleopening%63perforateddoorwith
completemetalframe,3pointhandledlocking

780 780
Front view
Front view Front view
H H
F16**
F17 R08*
R08*
*R08isthestandardreardoor.
**F16isthestandardfrontdoor.
SRV - HHU - WW
Product
range
ServerMAX
SRV
SRV
Width
&
depth=
1000 mm
WW
8
U
height
HHU
42U
47U
+ +
MX - FX - RX
780
H
Colour
options
MX
M01
M02
+
Front
door
options
FX
F16**
F17
R08*
+
Rear
door
options
RX
R08*
780
H
***F16,F17R08canbeusedasfrontorreardoor.
16
ServerMAX free standing
TECHNICALDRAWINGSFOR 800x1000-42U/47U
Part
number
Product
denition
(mm)
U
Size
Width:
overall
(mm)
Depth:
overall
(mm)
Depth: max
mounting
prole (mm)
Height:
vertical
mounting
prole (mm)
Height:
without
levelling feet
(mm)
Height:
with casters
(mm)
SRV42U8
42U 780x1000 mm 42 780 1000 740 1890 2002 2049
SRV47U8
47U 780x1000 mm 47 780 1000 740 2112 2224 2271
ServerMAX free standing cabinets 19” 780 x 1000 mm
Exploded view
F17***
F16**/***
R08*/***
*R08isthestandardreardoor.
**F16isthestandardfrontdoor.
***F16,F17,R08canbeusedasfrontorreardoor.
17
ServerMAX free standing
TECHNICALDRAWINGSFOR 800x1000-42U/47U
H=Enclosureheight
745
300
280
19”
906
140140 200
20029
1000
(Min 190)
195
(Min 762)
740
(Min 27)
44
Bottom view
Mounting profile
Front view
Front view
Top view Front viewIso view
Back viewSide view
780
1000
Front view
F16**
F17
R08*
780
300
H
1247
*R08isthestandardreardoor.
**F16isthestandardfrontdoor.
780
H
780
H
780
H
18
ServerMAX free standing
TECHNICALDRAWINGSFOR 600x1000
Exploded view
Iso view
Top view after extention unit
Note: Depth of existing cabinet + 200 mm
600
145
200
70
Technical drawing of extention unit D=200 mm for 600x1000 mm ServerMAX
Part
number
Product denition
(mm)
U
Size
Width:
overall
(mm)
Depth:
overall
(mm)
Height:
without
levelling feet
(mm)
Height:
with casters
(mm)
SRV26U EXT620
26U Extention unit D=200 mm, suitable for ServerMAX W=600 mm 26 600 200 1281 1328
SRV36U EXT620
36U Extention unit D=200 mm, suitable for ServerMAX W=600 mm 36 600 200 1726 1773
SRV42U EXT620
42U Extention unit D=200 mm, suitable for ServerMAX W=600 mm 42 600 200 1993 2040
SRV47U EXT620
47U Extention unit D=200 mm, suitable for ServerMAX W=600 mm 47 600 200 2215 2262
ServerMAX 19” 600 x 1000 mm extention unit
19
ServerMAX free standing
TECHNICALDRAWINGSFOR 800x1000
Part
number
Product denition
(mm)
U
Size
Width:
overall
(mm)
Depth:
overall
(mm)
Height:
without
levelling feet
(mm)
Height:
with casters
(mm)
SRV42U EXT820
42U Extention unit D=200 mm, suitable for ServerMAX W=780 mm 42 780 200 1993 2040
SRV47U EXT820
47U Extention unit D=200 mm, suitable for ServerMAX W=780 mm 47 780 200 2215 2262
ServerMAX 19” 780 x 1000 mm extention unit
Exploded view
Iso view
Top view after extention unit
Note: Depth of existing cabinet + 200 mm
780
145
200
70
Technical drawing of extention unit D=200 mm for 780x1000 mm ServerMAX
20
ServerMAX free standing
TECHNICALSPECIFICATIONS
KEY FEATURES
Mainprole(framework)hasanaestheticstructurewhich
increasesmechanicalresistance,foldedatanangleof90
degreesandconsistingof4bendsforeachprole.Intotal;
16foldsprovideframeworkstability.Additionally,2piece
verticalsidepaneldividerproleprovidesadditional
resistanceeachwitha4folddesign;totalof8foldadditional
support.IntotalServerMaxmainproleframeworkconsists
ofa24foldengineeringdesign.Manufacturedandtestedto
provideaxial(x,y,z)resistancethatmeetsEN61587-1/5.2.1
and5.2.2,andexternalimpactresistancethatmeets
EN61587-1/5.3.3.
Bottomanduppercaseshaveastructuretoincrease
theresistanceandstrengthofthecabinetbymonoblock
bended,weldedandprole-interlockingdesign.Prolesare
manufacturedtointerlockbottomanduppercaseswith
screws.Thebottomcaseprovidingcableaccessisttedwith
aslidingblankingaccessplatetopreventdust.
Arubberedgeonthecableaccessplateandslidingstructure,
itispossibletoxthecablesandallowscablestobeplaced
intothecabinetwithoutanydamage.
Additionaltherearepre-punchedknockoutsforair
distributiondeliveredfromraisedoor.
Reardoorinstandardcongurationisadoubleopening
doorwhichisremovableandlockable.Integrallockingisa3
pointlockingsystem.
Reardoorscanbeopenedupto215degrees,areremovable
andlockablewithhandletypelockingunit.
Sidepanelshaveastructurethatcanbeopenedand
removedwithslamlatchandkey.Theyarelockableand
removable.Sidepanelsconsistofadividerprolewhich
creates2piecessidepanelsoneachside.Originalfunctional
sidepanelislockableandremovableasmentionedabove;
thesmallersidepanelisxedfrominnersidewithscrews.
Ifadditionalventilationisneededthispanelcanbereplaced
withaslotted/perforatedone.
Withinthisengineeringconstruction,theoriginalfunctional
sidepanelbecomeseasytocarrywhilethedividerprole
providesbetterresistancy.
Frontdoorsaresingleopening,monoblock,welded,curved,
%63perforatedinstandard.Integrallockingas3pointlocking
system.Foroptionspleaseseetherelateddiagramsand
technicalchartsinpages11-15.
Frontdoorcanbeopenedupto215degrees,removableand
lockablewithhandletypelockingunit.
Ventedtoppanelhousingwithadedicatedspacefor
ventilation,thefanmodulesystemallowseasyinstallationof
max.6fansfromtop.
19”(inch)mountingangles(2ea.infrontand2ea.inrear)are
partofcabinetinteriorcongurationandadjustableindepth.
Bayingispossibleforsidebysideapplicationswithout
sidepanels.Levellingfeetandintegratedcastorgroupare
standardinshippingconguration.
ThecabinetmeetsEN61587-1,IEC60917,IEC60297
standards,RoHScompliancy,GostandTSEcertied.
Cabinetsaremanufacturedinourfactorywhichhas
ISO9001:2008QualityAssuranceSystemandour
responsibilityforenviromentwithISO14001:2004
EnvironmentalManagementSystem.
TESTS AND CERTIFICATIONS
Environment
EN61587-1/4.2,IEC60068-2-1,IEC60068-2-2,IEC60068-2-30,
IEC60917andIEC60297
Industrial environment
EN61587-1/4.3,IEC60068-2-42,IEC60068-2-43and
IEC60068-2-49,IEC60068-2-1,IEC60917andIEC60297
Statical mechanical structure load test
EN61587-1/5.2.1,IEC60917andIEC60297
Statical mechanical structure stability
EN61587-1/5.2.2,IEC60917andIEC60297
Dynamic load, vibration and mechanical stroke
EN61587-1/5.3.1,EN61587-1/5.3.3,IEC60917,IEC60297,
IEC62208
Grounding continuity
EN61587-1/6.2,IEC60917andIEC60297
Fire and ame resistance
EN61587-1/6.3,IEC60917andIEC60297
Corrosion
ISO9227andASTMB117-85,IEC60917andIEC60297
IP protection degree
IP20accordinglyEN61587-1/6.4,IEC60529,IEC60917and
IEC60297
Transportation
ETS300019-1-2Class2.3
Storage
ETS300019-1-1Class1.2
Security
EN60950_LVD
PURCHASED PRODUCT CERTIFICATIONS
Sheet steel
DINEN10130–99EreğliDC-016112,7122,RoHS
Electrostatic powder coating
ISO9001,ISO2178,ISO2813,ISO6272,ISO8130-5,
ISO8130-3,RoHS
Fan
ISO9001,CE(89/336/EECEMC,73/23/EECLVD),RoHS
Glass
ISO9001,EN12150–1:2000temperedandsecure
Fixings
DIN7985,DIN965,DIN7981,DIN934,DIN985,DIN933,
RoHS
Castors
TSEN12530,TSEN12532,RoHS
Lock
DIN1743,DIN53571,RoHS
21
ServerMAX free standing
ForCUSTOMIZEDPRODUCTSratherthan
aboveoptions,pleasecontactsalesdepartment.
TECHNICALSPECIFICATIONS
Custom number
85380000/85381000/853710990019
Packs of (ea.)
1
Shipping structure
Assembled
Mounting surface
Standalone
Load carrying capacity (kg)
1000
Certication on product
TSE,Gost
Surface nish
Electrostaticpowdercoatedc/withsurfacetreatment,80+/-5
micronpaintthicknessandtestedaccordingtoIEC60068-2-
1,2-2,2-30,2-42,2-43,2-49,2-11
STANDARD PRODUCT
Standart colour
RAL7035,RAL9005
Baying
Possiblewithbayingkitforsidebysideapplicationswithoutside
panels
IP protection standard
IP20
FRONT DOOR
Singleopening,monoblock,welded,curved,%63perforated
Front door construction
Monoblockcurved,weldedconstruction
Front door lock
Handletype,3pointlocking
Hinge system
Springloaded
Door opening angle and swapping
215degree
SIDE PANEL
Solidmetal,1mm.Leftandright(2ea.)
Construction
Lockable,removablec/withslamlatchesandlock
Lock
Barreltypelockunit,singlepoint+slamlatch(2ea)
REAR DOOR
Solidmetal,1mm
Rear door construction
Doubledooropening,%63perforated,lockable,removable
Rear door lock
Handledtypelockunit,3point
Hinge system
Springloaded
Door opening angle and swapping
215degree
FRAMEWORK
Top and bottom base units
SolidMetal2mm
Top and bottom base units construction
Completelyweldedcornersocketsystem
Uprights
Solidmetal,2mm
Uprights construction
Tightlyxedintotopandbottombaseunits
3timesfolded3x2=6folds
SIDE PANEL DIVIDER PROFILE
Solidmetal2mm
Side panel construction
Tightlyxedintotopandbottombaseunits
4timesfoldedx2=8folds
INTERIOR PARTS 
19’’ mounting angles
Solidmetal,2mm
1timesfoldedforanLprolesystem
Umarkingavailable
2ea.atrear,2ea.atfront
Pre-conguredas19’’
Zincplated,passivated,8-12micron
Adjustableindepth
Omega type support rails in depth
Solidmetal,1,5mm
3timesfoldedforW=600mmcabinets
OmegatypefoldedforW=780mmcabinets
3ea.atleft,3ea.atright26Uand36U
4ea.atleft,4ea.atright42Uand47U
22
ServerMAX free standing
accessories
FREQUENTLY USED ACCESSORIES SELECTION CHART FOR SERVERMAX
Estap has a wide range of accessories: Heavy duty xed shelves, sliding shelves, fans, cooling units, vertical cable
managements, cable rings, organisers, trays, plinths and so on...
* See the other and part number denition on pages 173-213.
* Please state colour choice in your orders. M01=RAL 9005 black and M02= RAL 7035 light grey
Frequently used accessories selection table
ServerMAX / Cable management unit
Enclosure
sizes*
(suitable for 780x1000 Server Cabinets)
800x1000
42U M44ORG42SRV
47U M44ORG47SRV
ServerMAX /
Part number
Cable management rings
44x30 K44RING01
44x60 K44RING021U
44x110 K44RING03
70x160 K44RING04
ServerMAX / Vertical PDU
part numbers
M44 24 AL IEC AMP MCB
ServerMAX /
Enclosure
sizes*
Floor xing kit
600x1000 800x1000
M44DPR03 M44DPR04
* Please check drawing pages for cabinet sizes.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20