Tyco PC5015 User manual

Category
Security access control systems
Type
User manual

This manual is also suitable for

Instruction
Manual
PC5O15
WARNING
This manual contains information on limitations regarding product use and
function and information on the limitations as to liability of the manufacturer.
The entire manual should be carefully read.
WARNING Please Read Carefully
Note to Installers
This warning contains vital information. As the only individual in contact
with system users, it is your responsibility to bring each item in this warning
to the attention of the users of this system.
System Failures
This system has been carefully designed to be as effective as possible. There
are circumstances, however, involving fire, burglary, or other types of emer-
gencies where it may not provide protection. Any alarm system of any type
may be compromised deliberately or may fail to operate as expected for a
variety of reasons. Some but not all of these reasons may be:
Inadequate Installation
A security system must be installed properly in order to provide adequate
protection. Every installation should be evaluated by a security professional
to ensure that all access points and areas are covered. Locks and latches on
windows and doors must be secure and operate as intended. Windows, doors,
walls, ceilings and other building materials must be of sufficient strength and
construction to provide the level of protection expected. A reevaluation must
be done during and after any construction activity. An evaluation by the fire
and/or police department is highly recommended if this service is available.
Criminal Knowledge
This system contains security features which were known to be effective at
the time of manufacture. It is possible for persons with criminal intent to
develop techniques which reduce the effectiveness of these features. It is im-
portant that a security system be reviewed periodically to ensure that its fea-
tures remain effective and that it be updated or replaced if it is found that it
does not provide the protection expected.
Access by Intruders
Intruders may enter through an unprotected access point, circumvent a
sensing device, evade detection by moving through an area of insuffi-
cient coverage, disconnect a warning device, or interfere with or pre-
vent the proper operation of the system.
Power Failure
Control units, intrusion detectors, smoke detectors and many other security
devices require an adequate power supply for proper operation. If a device
operates from batteries, it is possible for the batteries to fail. Even if the
batteries have not failed, they must be charged, in good condition and in-
stalled correctly. If a device operates only by AC power, any interruption,
however brief, will render that device inoperative while it does not have power.
Power interruptions of any length are often accompanied by voltage fluctua-
tions which may damage electronic equipment such as a security system. Af-
ter a power interruption has occurred, immediately conduct a complete sys-
tem test to ensure that the system operates as intended.
Failure of Replaceable Batteries
This system’s wireless transmitters have been designed to provide several
years of battery life under normal conditions. The expected battery life is a
function of the device environment, usage and type. Ambient conditions such
as high humidity, high or low temperatures, or large temperature fluctuations
may reduce the expected battery life. While each transmitting device has a
low battery monitor which identifies when the batteries need to be replaced,
this monitor may fail to operate as expected. Regular testing and maintenance
will keep the system in good operating condition.
Compromise of Radio Frequency (Wireless)
Devices
Signals may not reach the receiver under all circumstances which could
include metal objects placed on or near the radio path or deliberate jam-
ming or other inadvertent radio signal interference.
System Users
A user may not be able to operate a panic or emergency switch possibly due
to permanent or temporary physical disability, inability to reach the device in
time, or unfamiliarity with the correct operation. It is important that all sys-
tem users be trained in the correct operation of the alarm system and that they
know how to respond when the system indicates an alarm.
Smoke Detectors
Smoke detectors that are a part of this system may not properly alert occupants
of a fire for a number of reasons, some of which follow. The smoke detectors
may have been improperly installed or positioned. Smoke may not be able to
reach the smoke detectors, such as when the fire is in a chimney, walls or roofs,
or on the other side of closed doors. Smoke detectors may not detect smoke from
fires on another level of the residence or building.
Every fire is different in the amount of smoke produced and the rate of burn-
ing. Smoke detectors cannot sense all types of fires equally well. Smoke
detectors may not provide timely warning of fires caused by carelessness or
safety hazards such as smoking in bed, violent explosions, escaping gas,
improper storage of flammable materials, overloaded electrical circuits, chil-
dren playing with matches or arson.
Even if the smoke detector operates as intended, there may be circumstances
when there is insufficient warning to allow all occupants to escape in time to
avoid injury or death.
Motion Detectors
Motion detectors can only detect motion within the designated areas as
shown in their respective installation instructions. They cannot discrimi-
nate between intruders and intended occupants. Motion detectors do not
provide volumetric area protection. They have multiple beams of detection
and motion can only be detected in unobstructed areas covered by these
beams. They cannot detect motion which occurs behind walls, ceilings,
floor, closed doors, glass partitions, glass doors or windows. Any type of
tampering whether intentional or unintentional such as masking, painting,
or spraying of any material on the lenses, mirrors, windows or any other
part of the detection system will impair its proper operation.
Passive infrared motion detectors operate by sensing changes in tempera-
ture. However their effectiveness can be reduced when the ambient tempera-
ture rises near or above body temperature or if there are intentional or unin-
tentional sources of heat in or near the detection area. Some of these heat
sources could be heaters, radiators, stoves, barbeques, fireplaces, sunlight,
steam vents, lighting and so on.
Warning Devices
Warning devices such as sirens, bells, horns, or strobes may not warn people
or waken someone sleeping if there is an intervening wall or door. If warn-
ing devices are located on a different level of the residence or premise,
then it is less likely that the occupants will be alerted or awakened. Au-
dible warning devices may be interfered with by other noise sources such
as stereos, radios, televisions, air conditioners or other appliances, or passing
traffic. Audible warning devices, however loud, may not be heard by a
hearing-impaired person.
Telephone Lines
If telephone lines are used to transmit alarms, they may be out of service or busy
for certain periods of time. Also an intruder may cut the telephone line or defeat its
operation by more sophisticated means which may be difficult to detect.
Insufficient Time
There may be circumstances when the system will operate as intended, yet the
occupants will not be protected from the emergency due to their inability to
respond to the warnings in a timely manner. If the system is monitored, the
response may not occur in time to protect the occupants or their belongings.
Component Failure
Although every effort has been made to make this system as reliable as possible,
the system may fail to function as intended due to the failure of a component.
Inadequate Testing
Most problems that would prevent an alarm system from operating as in-
tended can be found by regular testing and maintenance. The complete sys-
tem should be tested weekly and immediately after a break-in, an attempted
break-in, a fire, a storm, an earthquake, an accident, or any kind of construc-
tion activity inside or outside the premises. The testing should include all
sensing devices, keypads, consoles, alarm indicating devices and any other
operational devices that are part of the system.
Security and Insurance
Regardless of its capabilities, an alarm system is not a substitute for prop-
erty or life insurance. An alarm system also is not a substitute for property
owners, renters, or other occupants to act prudently to prevent or minimize
the harmful effects of an emergency situation.
1
About Your Security System
Your DSC Power832 Security System has been designed to provide you with the greatest possible
flexibility and convenience. Read this manual carefully and have your installer instruct you on your
system's operation and on which features have been implemented in your system. All users of this
system should be equally instructed in its use. Fill out the “System Information” page with all of you
zone information and access codes and store this manual in a safe place for future reference.
Fire Detection
This equipment is capable of monitoring fire detection devices such as smoke detectors and providing
a warning if a fire condition is detected. Good fire detection depends on having adequate number of
detectors placed in appropriate locations. This equipment should be installed in accordance with
NFPA 72 (N.F.P.A., Batterymarch Park, Quincey MA 02269). Carefully review the Family Escape
Planning guidelines in this manual.
NOTE: Your installer must enable the fire detection portion of this equipment before it becomes
functional.
Testing
To insure that your system continues to function as intended, you must test your system weekly.
Please refer to “Testing Your System” on page 13 of this manual. If your system does not function
properly, call your installing company for service.
Monitoring
This system is capable of transmitting alarms, troubles and emergency information over telephone
lines to a central station. If you inadvertently initiate an alarm, immediately call the central station to
prevent an unnecessary response.
NOTE: The monitoring function must be enabled by the installer before it becomes functional.
General System Operation
Your security system is made up of a DSC Power832 control panel, one or more Power832 keypads
and various sensors and detectors. The control panel will be mounted out of the way in a utility closet
or in a basement. The metal cabinet contains the system electronics, fuses and stand-by battery.
There is normally no reason for anyone but the installer or service professional to have access to the
control panel.
All the keypads have an audible indicator and command entry keys. The LED keypads have a group
of zone and system status lights. The LCD keypad has an alphanumeric liquid crystal display (LCD).
The keypad is used to send commands to the system and to display the current system status. The
keypad(s) will be mounted in a convenient location inside the protected premises close to the entry/
exit door(s).
The security system has several zones of area protection and each of these zones will be connected
to one or more sensors (motion detectors, glassbreak detectors, door contacts, etc.). A sensor in
alarm will be indicated by the corresponding zone lights flashing on a LED keypad or by written
messages on the LCD keypad.
IMPORTANT NOTICE
A security system cannot prevent emergencies. It is only intended to alert you and – if included –
your central station of an emergency situation. Security systems are generally very reliable but
they may not work under all conditions and they are not a substitute for prudent security practices
or life and property insurance. Your security system should be installed and serviced by qualified
security professionals who should instruct you on the level of protection that has been provided
and on system operations.
2
System Information
Fill out the following information for future reference and store this manual in a safe place.
Access Codes
Your Master Code is:__________________________________________
Additional Access Codes:
01 __________________ 09 ____________________ 17 ____________________ 25 ________________
02 __________________ 10 ____________________ 18 ____________________ 26 ________________
03 __________________ 11 ____________________ 19 ____________________ 27 ________________
04 __________________ 12 ____________________ 20 ____________________ 28 ________________
05 __________________ 13 ____________________ 21 ____________________ 29 ________________
06 __________________ 14 ____________________ 22 ____________________ 30 ________________
07 __________________ 15 ____________________ 23 ____________________ 31 ________________
08 __________________ 16 ____________________ 24 ____________________ 32 ________________
Zone Information
There are ________ active zones on the system.
Zone Protected Area Zone Type
1 ___________________________________________ _____________________________________
2 ___________________________________________ _____________________________________
3 ___________________________________________ _____________________________________
4 ___________________________________________ _____________________________________
5 ___________________________________________ _____________________________________
6 ___________________________________________ _____________________________________
7 ___________________________________________ _____________________________________
8 ___________________________________________ _____________________________________
9 ___________________________________________ _____________________________________
10 ___________________________________________ _____________________________________
11 ___________________________________________ _____________________________________
12 ___________________________________________ _____________________________________
13 ___________________________________________ _____________________________________
14 ___________________________________________ _____________________________________
3
15 ___________________________________________ _____________________________________
16 ___________________________________________ _____________________________________
17 ___________________________________________ _____________________________________
18 ___________________________________________ _____________________________________
19 ___________________________________________ _____________________________________
20 ___________________________________________ _____________________________________
21 ___________________________________________ _____________________________________
22 ___________________________________________ _____________________________________
23 ___________________________________________ _____________________________________
24 ___________________________________________ _____________________________________
25 ___________________________________________ _____________________________________
26 ___________________________________________ _____________________________________
27 ___________________________________________ _____________________________________
28 ___________________________________________ _____________________________________
29 ___________________________________________ _____________________________________
30 ___________________________________________ _____________________________________
31 ___________________________________________ _____________________________________
32 ___________________________________________ _____________________________________
[F] FIRE __________________________________________
[A] AUXILIARY ____________________________________
[P] PANIC ________________________________________
The Exit Delay Time is________ seconds.
The Entry Delay Time is ______ seconds.
For Service
Central Station Information:
Account #:___________________________________ Telephone #:_________________________________
Installer Information:
Company: ___________________________________ Telephone #:_________________________________
4
Access Codes
Access codes are used to arm and disarm the system. There are 37 access codes available: 1 master
code, 32 regular access codes, 2 duress codes and 2 partition master codes. Ask your installer for
more information on using the duress and partition master codes.
Only the Master Code can be used to program additional security codes and to change other system
features as well as to arm and disarm the security system. The Master Code will be supplied to you by
your installer. All keypad entries are made by pressing one key at a time.
All access codes can be programmed by following the procedure outlined in “Programming Security
Codes” on page 7.
NOTE: An access code can be a four or six digit number depending on how your installer has
programmed your system. Ask your installer for more information regarding access codes.
Arming the System
Arming from an LED or LCD5501Z Keypad:
If the Ready light is ON, the system is ready for arming. If the Ready light is OFF, check to see that all
doors and windows are closed and that motion is stopped in areas covered by motion detectors. The
system cannot be armed unless the Ready light is ON indicating that all zones are closed and the
system is in the Ready state.
Enter your access code. As each digit is entered, the keypad sounder will beep. If the access code
was entered incorrectly, the keypad buzzer will sound steadily for two seconds. If this occurs, press
the [#] key and re-enter your access code. If the correct access code is entered, the keypad sounder
will beep quickly and the Armed light will come ON. Exit the premises through the door indicated by
your installer as the Exit/Entry door.
The panel will provide an exit delay period, indicated by keypad beeps, for you to exit the premises
without causing an alarm. At the end of the exit delay period, the Ready light will turn OFF and the
system will be armed. The exit delay time can be changed by your installer.
Arming from an LCD Keypad:
When this message appears, one or more zones are not secured. To secure the
system, close all doors and windows and cease all motion in areas covered by
motion detectors.
When this message appears, use the arrow (< >) keys to verify that the system is
clear of troubles and that no zones are bypassed unintentionally (see “Viewing
Trouble Conditions” on page 13 and “Zone Bypassing” on page 12).
If this display is showing, the system is in the Ready state and may be fully armed.
To arm the system, enter your access code.
Once the correct access code has been entered, the display will be as shown. The
panel will provide an exit delay period, also indicated by keypad beeps, for you to
exit the premises without causing an alarm. Exit through the door indicated by your
installer as the Exit/Entry door.
This message will be displayed once the exit delay expires and the system is fully
armed.
If this message appears, be aware of which zones are bypassed and why (see
“Zone Bypassing” on page 12). NOTE: If you arm the system with a zone
bypassed or with a trouble present, your security protection is reduced.
Secure System
Before Arming<>
Enter Code to
Arm System < >
Enter Code to
Arm System
Exit Delay in
Progress
* WARNING *
Bypass Active
Enter Code to
Disarm System
5
Alternate Arming Methods
Away Arming
Arming the system in the Away mode will have all interior zones and perimeter zones active. If motion
is detected in the interior zones, or if one of the perimeter zones is violated, the alarm sequence will
begin. To arm in the Away mode, enter your access code and exit the premises through a designated
Exit/Entry door. The system will recognize that occupants have left the premises. Once the exit delay
expires, the system will be fully armed.
If your installer has programmed the “Away” function key, you can use it at any time to Away arm your
system. Press and hold the key for 2 seconds to initiate away arming. If your system is stay armed,
pressing the Away key will turn on the interior zones and the system will be away armed.
Audible Exit Fault
In an attempt to reduce false alarms, the Audible Exit Fault is designed to notify you of an improper
exit when arming the system in the Away mode. In the event that you fail to exit the premises during
the allotted exit delay period, or if you do not securely close the Exit/Entry door, the system will notify
you that it was improperly armed in two ways: the keypad will emit one continuous beep and the bell or
siren will sound. If this occurs, you must re-enter the premises, enter your access code to disarm the
system, and then follow the arming procedure again, making sure to exit the premises in the proper
fashion. Your installer will tell you if the Audible Exit Fault has been enabled on your system.
Stay Arming
This feature, if enabled by your installer, will allow you to arm the perimeter zones while leaving the
interior zones inactive so that you can remain on the premises while the system is armed. When you
enter your security code to arm the system and
do not
exit the premises through a designated Exit/
Entry door, the system will arm in the Stay mode, automatically bypassing the interior zones.
If your installer has programmed the “Stay” function key, you can use it at any time to stay arm your
system. Press and hold the key for 2 seconds to turn on stay arming. If your system is away armed,
pressing the Stay key will turn off the interior zones and the system will be stay armed.
You can turn the interior zones on again by pressing the Away key or [
][1]. If you turn on the interior
zones, do not go into areas covered by motion detectors. To access areas protected by motion detectors,
you must enter your security code and disarm the system, or press the Stay key to turn off interior zones.
Arming Without Entry Delay
If you wish to arm your system without the entry delay, enter [][9] then your access code. The Armed
light will flash as a reminder that the system is armed and has no entry delay. An entry through any
zone programmed as a delay zone will create an instant alarm.
The entry delay can be activated or deactivated at any time while the system is armed by pressing [
][9].
Quick Arm
When the Quick Arm feature is enabled, the system may be armed by simply pressing [][0] instead of your
access code. Please note that pressing [][0] will only allow you to arm the system; to disarm, you must enter
a valid access code. Your installer will inform you if the Quick Arm feature has been enabled on your system.
Quick Exit
When the Quick Exit feature is enabled, pressing [][0] while the system is armed will provide a two minute
window for you to exit the premises. During this time, you may only open and close the designated Entry/
Exit door once. Once the door is closed, the panel will end the two minute quick exit delay. If the door is
opened again, or if the door is not closed after two minutes, or if another zone is opened, the panel will begin
the entry delay. Your installer will inform you if the Quick Exit feature has been enabled on your system.
6
Disarming the System
Disarming from an LED or LCD5501Z Keypad:
Enter the premises through a designated Exit/Entry door; entering by any other door will sound an
immediate alarm. As soon as the Exit/Entry door is opened, the keypad will beep to indicate that the
system should be disarmed. Go to the keypad and enter your access code. If an error is made
entering the code, enter your code again. As soon as the correct code is entered, the Armed light
will go out and the keypad will stop beeping.
The correct access code must be entered before the entry delay period expires. If a valid access
code is not entered during this time, the system will go into alarm. The entry delay time may be
changed by your installer.
If an alarm occurred while the system was armed, upon disarming the system, the Memory light and
the zone light corresponding to the zone (zone number on LCD5501Z) which caused the alarm will
flash for 30 seconds. After the 30 second period, the Memory light and zone light will stop flashing and
the panel will return to the Ready state. Pressing the [#] key during the 30 second period will cancel
the alarm memory display. To view other alarms, press [
][3].
If a trouble was detected when the panel is disarmed, the Trouble light will turn ON (See “Viewing
Trouble Conditions” on page 12 to determine the source of the trouble.) Please note that troubles will
not display while the system is in the Alarm Memory Display mode.
Disarming from an LCD Keypad:
Upon entering through a designated Exit/Entry door, the keypad will beep and the entry delay will
commence, reminding you to disarm the system. The keypad will display the following message...
Enter your access code. If an error is made in entering the code, enter the code
again.
When a valid access code is entered, the keypad will stop beeping. If no
alarms occurred while the panel was armed, and there are no troubles, the display
will read...
After about five seconds, the system will return to the Ready state and the display
will read...
If an alarm occurred while the system was armed, this message will be displayed.
Use the arrow (< >) keys to view which zones caused the alarm. If a zone is still in
alarm, the display will show the following message to indicate that a zone is open...
Upon disarming and if a trouble is present, this message will be displayed. Use the
arrow (< >) keys to view which troubles are affecting the system (see “Viewing
Trouble Conditions” on page 12).
NOTE: If you return and find that an alarm has occurred while you were away, it is possible that
an intruder may still be on the premises. Go to a neighbour's house, and call the local police to
investigate.
The alarm memory is cleared each time the panel is armed so that any alarms showing are
alarms that occurred only during the last armed period.
Entry Active
Enter Your Code
Enter Code to
Arm System < >
Secure System
Before Arming <>
Enter Code to
Arm System
View Memory < >
“Zone of Alarm”
System Disarmed
No Alarm Memory
7
If An Alarm Sounds
Fire Alarm
If your system has been installed with fire detectors and the alarm sounds in a pulsing mode, follow
your emergency evacuation plan immediately (see “Fire Escape Planning” on page 15).
Intrusion Alarm
If an intrusion alarm sounds, indicated by a continuous bell or siren, the alarm may be silenced by
entering your access code. If the alarm was unintentional, call local authorities immediately to avoid an
unnecessary response.
You can determine the source of the alarm by following the instructions in the “Disarming” section (see
page 6). Once the source of the alarm has been corrected, the panel can be restored to its original
Armed state.
Function Keys
Each keypad has five function keys, located to the right of the number pad, which allow easy single-
button activation of the most commonly used features.
If these keys have been enabled by your
installer
, you can execute their programmed function by pressing and holding the corresponding key
for two seconds.
For information regarding the operation of the function keys, talk to your alarm installer.
Programming Security Codes
Programming codes from an LED or LCD5501Z Keypad:
The Master Code
To program the Master Code, enter [
][5][current Master Code][40][new Master Code]. The Master
Code must be four digits unless otherwise indicated by your installer. Enter digits 0 through 9 only.
Press [#] to return to the Ready state.
Be sure to record your new Master Code on the “System Information” page in this booklet. NOTE: We
recommend that the factory default Master Code [1234] not be used.
Additional Codes
Up to 36 additional codes may be programmed. Codes 01-32 are regular access codes. Codes 33
and 34 are duress codes. Codes 41 and 42 are the partition 1 and partition 2 master codes,
respectively.
To program a new code:
Enter [
][5][Master code][code number][new access code]. The code number is a double-digit
number from 01-34 or 41-42.
Access codes must be four digits long. Enter digits 0 through 9 only.
To exit code programming, press [#].
If an access code already exists for the code number you have selected, it will be replaced by the
new code. Be sure to record your new code(s) on the “System Information” page in this book.
To erase a code:
Enter [][5][Master code][code number][]. To exit code programming, press [#]. The master code
cannot be erased.
Continued on page 11...
88
PC5508(Z), PC5516(Z) and
PC5532(Z) Keypads:
Press the keys on the number pad
to view alarms or troubles, to Arm/
Disarm the system or to bypass
zones. To exit, press [#]; to select a
function, press [
].
Ready Light
(All keypads)
:
If the Ready light is ON, the system is ready
for arming.
If the Ready light is OFF, check to see that
all doors and windows are closed and that
all movement is stopped in areas covered
by motion detectors. The system cannot be
armed unless the Ready light is ON
indicating that all zones are closed and the
system is in the Ready state.
Display Lights
Armed Light
(All keypads)
:
If the Armed light is ON, the system has been
armed successfully.
Trouble Light
(All keypads)
:
If the Trouble light is ON, check to see what the
trouble condition is and call for service (See
“Viewing Trouble Conditions” on page 13).
PC5508(Z) LED Keypad
The PC5508, PC5508Z, PC5516 and PC5516Z
Keypads are available for applications with fewer
than 32 zones. The functions explained in this manual
are the same for all three LED keypad types.
PC5516(Z) LED Keypad
99
All Keypads:
Function Keys
(Stay, Away, Chime, Reset, Exit):
If activated by your installer, these
keys allow easy single button
activation of the most commonly used
features. For more information, talk to
your alarm installer.
Press both Keys for two seconds
to send a FIRE transmission.
Press both
Keys for two seconds
to send an AUXILIARY transmission.
Press both
Keys for two seconds
to send a PANIC transmission.
NOTE
(All Keypads)
: The Fire,
Auxiliary and Panic keys will NOT
function unless programmed by
the installer. If these keys are in
service and the installer has enabled
audible feedback, holding down the
key for two seconds will cause the
keypad sounder to beep indicating
that the input has been accepted and
transmission is underway.
Memory Light
(LED keypads only)
:
Upon disarming, if an alarm has occurred
while the system was armed, the Memory light
will turn ON (See “Disarming the System” on
page 6).
Bypass Light
(LED keypads only)
:
If the Bypass light is ON, ensure that zones
are intentionally bypassed before arming the
system (See “Zone Bypassing”
on page 12).
Fire Light
(LED keypads only)
:
If the Fire light is ON, a fire alarm has
occurred (See “Fire Alarm Operation”
on page 16).
Program Light
(LED keypads only)
:
The Program light will flash you are
programming access codes, setting
the system time or performing other
programming functions. If someone is
programming at another keypad, the
Program light will turn ON to indicate
that the system is busy.
PC5532(Z) LED Keypad
10
LCD5500(Z) Keypad:
The Liquid Crystal Display (LCD) displays prompts and
system information on two 16 character lines.
If “< >” appears, more information can be accessed by
using the arrow (< >) keys. Press [<] to see the previous
function or item of information. Press [>] to advance the
display to next function or item of information.
Press the keys on the number pad as prompted by the
LCD display to view alarms or troubles, to arm and
disarm the system and to bypass zones.
To exit a function and return to the Ready state, press [#];
to select a function press [
].
NOTE: All functions can be performed from any LCD
keypad by using the LED keypad commands, as well
as by scrolling through the message display.
Important Note: Test system weekly and have any system
trouble conditions corrected by your alarm installer.
LCD5500(Z) Keypad
LCD5501Z Keypad:
The LCD5501Z keypad shows the status of your
security system using an LCD, along with fixed
words and numbers.
LCD5501Z Keypad
11
Programming codes from an LCD Keypad:
Master Code
Press the [
] key to enter the function list. Scroll (< >) to...
Press [5] or [
]. The display will read...
Enter your current Master Code. The display will read...
“01P” represents the first access code. Use the arrow (< >) keys to scroll to “40P”
and press the [
] key to indicate that you wish to program the Master Code. The
display will read...
Enter the new Master Code. The Master Code must be four digits unless otherwise
indicated by your installer. Enter digits 0 through 9 only. Once the new code is
entered, the keypad will beep 3 times and the display will read...
Press [#] to exit the code programming function.
Be sure to record your new Master Code on the “System Information” page in this booklet.
NOTE: We recommend that the factory default Master Code [1234] not be used.
Additional Access Codes
To erase, add or change a user code, press [
] to enter the functions list. Use the arrow (< >) keys to
scroll to the following message...
Press []. Display will read...
Enter the Master Code. Display will read...
Use the scroll keys (< >) to find the access code – indicated by “01P” to “34P” or
“41P” to “42P” – you wish to add, change or delete. Press the [
] key to select the
code you wish to alter. The display will read...
To add or change a code, enter the new code. Access codes must be four digits
unless otherwise indicated by your installer. Enter digits 0 through 9 only. To delete
an access code, enter [
]. Once the 4 digit code or [] has been entered, the
keypad sounder will beep 3 times and the display will read...
The “P” means the code has been programmed. If there is no “P” then that code is
deleted. Press [#] to exit the code programming function. The Master Code cannot
be erased.
Remember to record your new code(s) on the “System Information” page in this booklet.
Access Code Attributes
Additional programmable attributes, such as zone bypassing capability, can be activated or
deactivated for each access code. For more information regarding access code attributes, please
contact your installer.
Partition Master Codes
If your system is partitioned, you can have a master code for each partition. Partition 1 master code is
access code 41, partition 2 master code is access code 42.
Press (*) for<>
Access Codes
Enter Master
Access Code
[*] to Edit <>
User Code 01P
Enter New Code
1234 < >
[*] to Edit <>
User Code 01P
(*) to Edit < >
User Code 01P
Enter Master
Access Code
(*) to Edit < >
User Code 01P
Enter New Code
1234 < >
Press (*) for<>
Access Codes
12
Zone Bypassing
The zone bypassing function is used when access is needed to part of the protected area while the
system is armed. Zones which are temporarily out of service due to damaged wiring or contacts may
be bypassed to allow system arming until repairs can be made.
Bypassed zones will not cause an alarm. Zones cannot be bypassed once the system is armed.
Bypassed zones are automatically cancelled each time the system is disarmed and must be reapplied
before the next arming.
NOTE: For security reasons, your installer may program the system to prevent you from bypassing
certain zones.
Bypassing zones reduces your security protection. If you are bypassing a zone due to damaged wiring
or contacts, please call a service technician immediately so that the problem can be resolved and your
system returned to proper working order.
Do not unintentionally bypass zones when you arm your system.
To bypass zones from an LED or LCD5501Z keypad:
Start with the system in the Ready state. Enter [][1][Zone number(s) to be bypassed].
Enter the zone number(s) as a double digit from 01 to 32. As each zone is bypassed, the corresponding zone
light will turn ON (LCD5501Z will display the zone number). If multiple zones are bypassed, the LCD5501Z
will scroll through the zone numbers. If a zone is bypassed by mistake, press that zone number again and the
zone light will turn OFF, indicating that the zone is not bypassed. Press [#] to return to the Ready state.
When the system is armed, the Bypass light will be ON if one or more zones are bypassed.
To bypass zones from an LCD keypad:
To bypass a zone, the system must be in the Ready state. The display will read...
Press the [
] key to enter the functions menu. The display will read...
Press the [
] key to enter the zone bypassing mode. The display will read...
Use the arrow (< >) keys to find the zone to be bypassed and press the [
] key to
select it. The display will read...
“B” will appear on the display to show that the zone is bypassed. To unbypass a
zone, enter the zone number; the “B” will disappear from the display to show that
the zone is no longer bypassed.
This display will be shown if a zone was open when you entered the bypassing
command. The open zone will be represented by “O”. If you bypass the open zone,
the “O” will be replaced by a “B”.
To exit the bypassing mode and return to the Ready state, press the [#] key.
Bypass Groups
A Bypass Group is a selection of zones programmed into the system’s memory. The Bypass Group
can be recalled upon arming to allow quick bypassing of a selection of zones on a regular basis. Two
Bypass Groups can be programmed on the system.
To program a Bypass Group, perform the following:
1. Press [][1], followed by your access code, if necessary.
2. Enter the zone numbers of the zones to be included in the Bypass Group. Each zone number is two digits.
3. Once all zones to be included have been selected, press [9][5] for Bypass Group #1 or [9][6] for
Bypass Group #2.
To select a Bypass Group when arming the system, perform the following:
1. Press [][1], followed by your access code, if necessary.
2. Press [9][1] to select Bypass Group #1 or [9][2] for Bypass Group #2.
3. Press [#] to return to the Ready state. Arm the system.
Enter Code to
Arm System
Press (*) for<>
Zone Bypass
Zone Search < >
“Zone Name”
Zone Search < >
“Zone Name” B
Zone Search < >
“Zone Name” O
13
Additional Zone Bypassing Features
To recall the last set of bypassed zones, press [][1][9][9]. Arm the system. The Bypass light will turn
on to indicate that zones are bypassed.
To clear all bypassed zones, press [][1][0][0].
Viewing Trouble Conditions
The control panel continuously monitors a number of possible trouble conditions. If one of these trouble
conditions occur, the keypad will beep twice every 10 seconds until you press any key on the keypad.
NOTE: A TROUBLE condition reduces the security your system is designed to provide. Call your
installing company for service.
To view troubles from an LED or LCD5501Z Keypad:
A trouble will be indicated by the Trouble light which will remain ON until the trouble condition is cleared.
If you cannot determine or remedy the cause of the trouble condition, contact your installer for assistance.
To view the type of trouble condition, press [][2]. One or more zone lights (trouble indicators on the
LCD5501Z) will turn ON, indicating the various trouble conditions:
Zone Light Type of Trouble
(Trouble Indicator)
1 ....... Service required. Call your installation company for service. Press [1] and one or more of the
zone lights corresponding to the following system troubles will turn ON:
1.Low Battery 5.General System Supervisory
2.Bell Circuit Trouble 6.Not used
3.General System Trouble 7.PC5204 Low Battery
4.General System Tamper 8.PC5204 AC Failure
2 ....... Indicates the loss of AC power. When this trouble occurs, the Trouble light will turn ON but
the keypad buzzer will not sound.
3 ....... Telephone line trouble.
4 ....... The panel has failed to communicate with the central station.
5 ....... Zone fault. Press [5] and the zone light(s) corresponding to the faulted zones will turn ON.
6 ....... Zone tamper. Press [6] and the zone light(s) corresponding to the tampered zones will turn ON.
7 ....... Low zone battery. This trouble is generated when a wireless device exhibits a low battery
condition.
Press [7] one, two, or three times to view which devices are experiencing battery failure.
The following will occur:
Keypad Beeps Keypad Display
Press [7] ........... 1 ..........Zones with low batteries (LED keypad - zone lights 1 to 8)
Press [7] again .. 2 ..........Handheld keypads with low batteries (LED keypad - zone lights 1 to 4)
Press [7] again .. 3 ..........Wireless keys with low batteries (LED keypad - zone lights 1 to 8).
To view the battery conditions of wireless keys 9 through 16, you
must be at an LCD keypad.
8 ....... Loss of time on system clock. To set the system time, following the instructions in “Setting
System Date and Time” on page 14.
14
To view troubles from an LCD Keypad:
From the Ready state, use the arrow (< >) keys to scroll to the following message.
Press [] [2] to view the trouble. The message will read...
Use the arrow (< >) keys to view which troubles are present on the system. Once you
have scrolled through the list of troubles, press the [#] key to exit the Trouble Viewing
mode and return to the Ready state.
Setting the System Date and Time
To set the system time, enter [] [6] followed by the Master Code. Press [1]. The keypad will now
accept 10 consecutive digits:
Enter the Time in Hours and Minutes using the 24 Hour format (00:00 to 23:59).
Enter the Date in Months, Days and Years (MM DD YY).
NOTE: If you have an LCD keypad, your installer may have programmed your system to display the
time and date while the keypad is idle. If this is the case, you may have to press the [#] key to clear
the date and time before entering an access code to arm the system, or before performing any
other keypad function.
Testing Your System
Alarm Test
The Alarm Test provides a two second test of the keypad sounder and bell or siren. Begin with the
panel in the Ready state.
From an LED keypad, Enter [
][6][Master Code][4] then press [#] to return to the Ready state.
From an LCD keypad, press [] to enter the functions list. Use the arrow (< >) keys to scroll to find “User
Functions” and press [] to select. Enter your Master Code and scroll to find the following message...
Press [] to perform an Alarm Test. The keypad will display the following message...
Press [#] to return to the Ready state.
Full System Test
We recommend that you test your system weekly. Should the system fail to function properly, call your
installation company immediately for service.
NOTE: Perform system tests at off-peak hours.
1. Inform the central station that you are testing your system.
2. Begin with the system in the Ready state.
3. Perform a Bell/Battery test by pressing [
][6][Master Code][4]. The bell and keypad buzzer will
sound for two seconds and all keypad lights will turn ON. Press [#] to exit.
4. Activate each sensor in turn (e.g. open a door/window or walk in motion detector areas).
From an LED keypad, observe the zone light turn ON when the zone is activated. The zone light will
turn OFF when the system restores to normal (i.e. door or window closed).
From an LCD keypad, the following message will be displayed when each zone is activated...
Use the arrow (< >) keys to view which zone is open. This message will
disappear when the zone is restored.
Select Option<>
System Test
System Test
In Progress
Secure System
Before Arming<>
System Trouble
(*2) to View< >
View Trouble < >
“Trouble Message”
15
5. If the panel has any fire zones, activation will cause the alarm signal to sound in a pulsed mode.
CAUTION: Do not use an open flame or burning materials to test a smoke or heat detector.
Contact your installer for information on safe methods of testing detectors.
6. When testing is complete, call and advise the central station. Should the system fail to function
properly, contact your installer.
NOTE: Some features described above will not be functional unless enabled by your installer.
Please ensure that your installer has advised you which features are functional on your system.
Door Chime Feature
The door chime feature is used, while the panel is disarmed, to provide a tone from the keypad each
time a door or window is opened or closed. The doors and windows which will provide this indication
are programmed by your installer.
To activate the door chime from an LED or LCD5501Z Keypad:
Enter [][4] to turn the door chime feature ON and OFF. When the command is entered, the keypad
buzzer will beep 3 times if the door chime feature is enabled and will sound one long beep if it is
disabled. Press [#] to return to the Ready state.
To activate the door chime from an LCD Keypad:
Start with the panel in the disarmed mode, press [] to enter the function list, then scroll to find...
Press [
] or [4] to enable or disable the Door Chime feature. Press [#] to return to
the Ready state.
Keypad Options
All Keypads
Keypad Sounder Control
There are 21 different keypad sounder tones available for the Power832 keypads. From an LCD keypad,
enter [
][6] [Master code], then use the arrow (< >) keys to scroll to the message “Keypad Buzzer
Control.” Press [] to select the option. Use the arrow (< >) keys to scroll to the desired buzzer sound.
Press [#] to exit. This feature can be accessed from an LED keypad by pressing and holding the [
] key.
LCD5500 Keypads Only
Language Selection
The displayed language of the keypad can be changed by pressing and holding both of the arrow (< >)
keys simultaneously. This will cause the keypad to enter the Language Selection mode. Scroll to the
desired language and press the [
] key. This will select the new language and restart the keypad.
The following three options are accessed by entering [
] [6] [Master code]. Use the arrow (< >)
keys to scroll to the appropriate message and press [
] to select.
Brightness Control
When this option is selected, the keypad will allow you to scroll through 10 different backlighting
levels. Use the arrow (< >) keys to scroll to the desired backlighting level and press the [#] key to exit.
Contrast Control
When this option is selected, the keypad will allow you to scroll through 10 different LCD display contrast
levels. Use the arrow (< >) keys to scroll to the desired contrast level and press the [#] key to exit.
View Event Buffer
The panel will store the last 128 events which occurred on the system. To view the event buffer, select
the “View Event Buffer” prompt from the user functions list. The keypad will display the event number,
partition, time and date of each event. To toggle to the event name, press the [
] key. Use the arrow (<
Press (*) For<>
Door Chime
16
>) keys to scroll through all of the events in the buffer. When you have finished viewing the events,
press [#] to exit.
Downloading Enable
To enable a six-hour downloading window from any system keypad, enter [] [6] [Master code] [5].
During this time, the panel will answer incoming downloading calls. For more information, please ask
your installer.
Fire Alarm Operation
Alarm
On a fire alarm, the bell or siren will pulse ON and OFF. The transmission of the alarm to the central
station is delayed for 30 seconds. If the alarm is not cleared within the 30 second delay, it will then be
transmitted to the central station.
Silence
To silence the bell or siren, press the [#] key. If the alarm is silenced and the smoke detector is not
reset, the alarm will resound after 90 seconds.
Resetting Smoke Detectors
Once the smoke detector is reset, if it still detects smoke, the alarm sequence will resound as
described above. If there is no smoke, the system will return to normal.
To reset smoke detectors from an LED or LCD5501Z Keypad: Press [
][7][2].
To reset smoke detectors from an LCD Keypad:
Press [] to enter the function list. Scroll to find:
Press [] to select the output control. The display will read...
Use the arrow (< >) keys to find the following message and press the [] key to
select...
NOTES: If you suspect that a fire alarm has transmitted and that there is no fire condition, call
the central station to avoid an unnecessary response.
If a fire condition is apparent, follow your
evacuation plan immediately. If the alarm sounds at night, evacuate immediately.
The description above may not be applicable depending on how your installer has programmed
the fire alarm operations on your system. Ask your installer for more information regarding your
system's operation.
Household Fire Safety Audit
Most fires occur in the home. To minimize this danger, we recommend that a household fire safety
audit be conducted and a fire escape plan be developed.
1. Are all electrical appliances and outlets in a safe condition? Check for frayed cords, overloaded
lighting circuits, etc. If you are uncertain about the condition of your electrical appliances or
household service, have a professional evaluate these units.
2. Are all flammable liquids stored safely in closed containers in a well ventilated cool area? Cleaning
with flammable liquids should be avoided.
3. Are fire hazardous materials (matches) well out of reach of children?
4. Are furnaces and wood burning appliances properly installed, clean and in good working order?
Have a professional evaluate these appliances.
Select Output<>
Command O/P 1
Select Output<>
Command O/P 2
Press (*) For<>
Output Control
17
Fire Escape Planning
There is often very little time between the detection of a fire and the time it becomes deadly. It is thus
very important that a family escape plan be developed and rehearsed.
1. Every family member should participate in developing the escape plan.
2. Study the possible escape routes from each location within the house. Since many fires occur at
night, special attention should be given to the escape routes from sleeping quarters.
3. Escape from a bedroom must be possible without opening the interior door.
Consider the following when making your escape plans:
Make sure that all perimeter doors and windows are easily opened. Ensure that they are not
painted shut, and that their locking mechanisms operate smoothly.
If opening or using the exit is too difficult for children, the elderly or handicapped, plans for
rescue should be developed. This includes making sure that those who are to perform the rescue
can promptly hear the fire warning signal.
If the exit is above the ground level, an approved fire ladder or rope should be provided as well
as training in its use.
Exits on the ground level should be kept clear. Be sure to remove snow from exterior patio doors
in winter; outdoor furniture or equipment should not block exits.
Each person should know of a predetermined assembly point where everyone can be accounted
for i.e.: across the street or at a neighbour's house. Once everyone is out of the building, call the
Fire Department.
A good plan emphasizes quick escape. Do not investigate or attempt to fight the fire, and do not
gather belongings or pets as this wastes valuable time. Once outside, do not re-enter the house.
Wait for the fire department.
Write the fire escape plan down and rehearse it frequently so that should an emergency arise,
everyone will know what to do. Revise the plan as conditions change, such as the number of
people in the home, or if there are changes to the building's construction.
Make sure your fire warning system is operational by conducting weekly tests (see “Fire Alarm
Operation” on page 14). If you are unsure about system operation, contact your installing dealer.
We recommend that you contact your local fire department and request further information on fire
safety and escape planning. If available, have your local fire prevention officer conduct an in-
house fire safety inspection.
Maintenance
With normal use, the system requires minimum maintenance. The following points should be observed.
1.Do not wash the security station with a wet cloth. Light dusting with a slightly moistened cloth should
remove normal accumulations of dust.
2.The battery/bell test is designed to determine battery condition. We recommended, however, that
the stand-by batteries be replaced every three years.
3.For other system devices such as smoke detectors, passive infrared, ultrasonic or microwave motion
detectors or glassbreak detectors, consult the respective manufacturer’s literature for testing and
maintenance.
18
NOTES
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Tyco PC5015 User manual

Category
Security access control systems
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI