Advantech DLoG XMT 5 Series Quick Start

Type
Quick Start
1
Prepare / Switch on XMT 5
Quickstart
XMT 5 Series
Tip: Congure the XMT 5 before fastening it to machines or vehicles, because in
this way software conguration for the WLAN function, for Automatic switch-off, etc.
is signicantly simpler and more convenient.
Prerequisites:
• Advantech-DLoG power supply cable
• Advantech-DLoG Preconverter (a special table supply power unit),
to connect the XMT 5 to an AC power supply.
The Preconverter is specially prepared to simulate a vehicle’s
ignition signal: DC+ and Ign are connected with the +Pole of the power supply.
• If you want to operate the XMT 5 using an external mouse or
keyboard, connect this before switching on the device.
3
Rotate Screen and Admin Tools
2
Conguration with neXt Cong
Power supply / Switch on the device
• Connect the XMT 5 to the power supply using an Advantech-DLoG Preconverter.
• Press the <Power>-key (for a short time; max. 1 second).
• The XMT 5 will start.
You can open the Rotate Screen and Admin Tools (manage user rights) functions
via the XMT 5 context menu.
• The context menu can be opened on the XMT 5 screen with the
right mouse button or by pressing the touch screen (min. 2 sec.).
The following functions and others are available:
Rotate Screen – To rotate the current display
Admin Tools | Recalibrate Touch – To recalibrate the touch screen
• Don‘t forget: SaveRegistry must be executed to save new calibration data.
Admin Tools | Enter Admin Mode
The Enter Admin Mode function
opens the XMT 5 Security Shell.
The Security Shell is used to protect
the system against unintended changes
by standard users.
Caution: You must restart the computer
after setting up the security shell.
!
Notice: The XMT 5 series is equipped with an integrated, galvanic isolated power
supply for direct voltage. 12/24 VDC and 24/48 VDC models are available.
The output voltage of the Preconverter must be compatible with the input voltage
of the XMT 5. If it is not, the XMT 5 may become badly damaged.
Preconverter and Power supply
cable for XMT 5 Series
XMT 5 Series: XMT 5/7 and XMT 5/10
Your XMT 5 is equipped with the conguration program „DLoG neXt Cong“. You can de-
ne the display brightness, automatic switch-off and front key assignment and other settings
with this program.
Only system administrators may congure the XMT 5.
a) Log on as an administrator
• Click the green neXt Cong icon in the task bar:
NeXt Cong will start.
• Open the menu item Advanced | Change Mode.
• Click Change Mode.
• Switch to Admin Mode. The passwort is: „gold“
• Save the setting.
The neXt Cong icon in the task bar will now be yellow.
Admin Mode is active.
You can now congure the automatic switch-off and the front keys.
b) Congure the automatic switch-off function
Each XMT 5 has been equipped with an automatic shutdown function. This function has
already been pre-congured and governs the power-up and shutdown procedures for the
XMT 5 connected to a car ignition.
The precongured settings for each XMT 5 must be adapted for each customer.
• Open the Switch-Off menu in neXt Cong.
• Check and congure the settings.
• Save your settings
c) Program the keys on the front of the XMT 5
• Open the Set Front Keys menu in neXt Cong.
An interactive graphic appears with the available keys for the XMT 5.
• You can assign specic keyboard commands or program requests
to the front keys there.
• Save your settings
Tip: The Set Front Key settings for an XMT 5 can be exported as a cong le and copied
quickly and easily to other devices. You can nd more details in the XMT 5 manual
(available from the Advantech-DLoG Download Center).
!
Notice: If the XMT 5 is congured for switching on with an ignition signal, the
ignition signal must be connected to the power supply plug.
6
Electrical installation
7
Cable cover and strain relief
8
Further information
Notice:
• Ensure that the ground connection is correct!
• Choose a suitable position on the forklift for the ground connection.
• Sometimes the position from which the ground signal is to come is
specied by the vehicle manufacturer
• Position and connect the XMT 5 as close to the battery as possible.
• Do not attach the XMT 5 directly to a connector for a high-powered consumer
(e.g. an inverter for fork lift motors) as this could lead to
restarts, malfunctions or damage to the device.
• Some forklifts have a chassis that is connected to DC+.
Therefore, the XMT 5 chassis is also connected to DC+.
However, if you use peripheral devices that supply DC- to the
DLoG MTC 6 via an interconnector (such as a DC- serial port),
this will cause a short circuit. This will inevitably lead to malfunctions
or even a total system failure.
5
Mechanical installation
Position of the XMT 5 on the vehicle
• The driver‘s eld of vision in the vehicle must not be obstructed.
• If you want to install a keyboard and scanner on the side of the XMT 5,
please allow enough space.
Overview of the installation steps
Before you mount the XMT 5 onto the vehicle:
• The automatic switch-off function must be congured.
• The forklift must be prepared (connection to ignition, observe correct voltage, etc.).
We recommend that the installation process is carried out in the following sequence:
• Step 1: Secure the mounting bracket onto the vehicle
• Step 2: Attach the XMT 5 to the mounting bracket; please observe the assembly
instructions that come with the relevant mounting kit.
4
Wireless networks
The XMT 5 optionally contains a Summit WLAN card. Generally, the WLAN prole is set as
default in the factory by Advantech-DLoG for this card. If any adjustments are required, the
Summit Client Utility tool for modifying the WLAN prole is available.
Summit Client Utility Program
• Start the Summit Client Utility program with the SCU-Icon on the desktop.
• Log on with the password „SUMMIT“ (all uppercase).
• Make the desired settings.
Tip: Use the help function for this program to read details about the setting options.
!
Notice: WLAN settings may be made only by
qualied technical staff.
!
User manuals / device drivers in the Download Center
Manuals and the latest device drivers for your Advantech-DLoG industrial PC can
be found in the Downloads menu at www.advantech-dlog.com.
If you have any further questions, please contact your Advantech-DLoG service partner or
contact us directly at:
Industriestraße 15 www.advantech-dlog.com
D-82110 Germering Phone: (+49) 89 / 41 11 91 - 999
Ground bolt
XMT 5 connectors,
24/48 VDC
XMT 5 connectors,
12/24 VDC
Once the XMT 5 and mounting bracket have been secured:
• Prepare the strain relief.
• Position the cables on the stress relief rail so that they will
t through the openings in the cable cover.
• Mount the cables loosely on the strain relief rail.
Final steps:
• Fix the cables to the strain relief rail.
• Close the cable cover carefully, observing the assembly instructions provided
with the XMT 5.
Example for cable positioning
to the strain relief rail
Copyright 2011 by DLoG GmbH, Industriestraße 15, D-82110 Germering. All rights reserved.
Information in this document is subject to change without prior notice.
Quickstart Guide XMT 5 Series V1.00 DAN 885904E.00
  • Page 1 1
  • Page 2 2

Advantech DLoG XMT 5 Series Quick Start

Type
Quick Start

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI