1. Warnings
Please read these instructions carefully. Keep these
instructions in a safe place and pass them on to possible
future owners.
- Use device for room heating within enclosed rooms
only.
- Repairs and corrective measures may only be carried
out by skilled electricians.
- Disconnect the power supply in the event of fault or
when device is not used for an extended period of
time. Pull out the device plug or switch off the fuse.
- Do not cover the heating device with any
objects; fire hazard!
The device carries the symbol shown on
the right which indicates that the heating
device must under no circumstances be covered with
any objects.
- Caution! The outer surfaces of the device are hot
during operation.
- Do not operate the heating device without supervision
when small children can get close to the device.
- Observe the applicable provisions for setting up power
installations with nominal voltages of up to 1,000 V
when assembling and installing the devices.
- Install the device in such a manner that the controls
cannot be touched by a person in the bathtub or under
the shower.
- Do not operate the heating device in rooms where
highly inflammable substances are used (e.g.
solvents, etc.).
- Do not lay the connecting cable across the hot device.
- Caution! If the thermostat switches on the connected
unit automatically during your absence, there is a
potential danger of fire if, for example, the unit is
covered or if it is blocked by objects.
2. Technical Data
Connection voltage: 1/N/PE ~ 230V 50 Hz
Nominal output H 260/1, H 261/1: 2,000 W
Nominal output H 260/2: 1,000 W
Dimensions: (W x H x D) 290 x 410 x 135 mm
H 261/1: Clock timer 0 - 60 minutes
Degree of protection IPX4, protection class I.
3. Minimum Clearances and Installation
The heater may only be installed and operated in a vertical
position on vertical walls.
Do not place the heating device directly below wall sockets.
Install the device in such a manner that the controls cannot
be touched by a person in the bathtub or under the shower.
The plug must be accessible after installation.
The minimum clearances listed in the installation drawing
must be strictly observed.
100
100
300
100
Dimensions in mm
In addition, a minimum clearance of 350 mm between
inflammable objects and the front of the unit must be
maintained.
Especially highly inflammable objects such as textiles or
heat-sensitive plastics should be kept away from the hot air
flow.
The wall bracket is mounted to the wall with 2 screws. The
enclosed plastic bag contains screws and dowels.
Mounting Instruction:
1. Remove the wall bracket from the back of the unit.
2. Drill mounting holes for the wall bracket and insert the
dowels.
3. Align the wall bracket and firmly screw it onto the wall.
4. Loosen the locking screws (III) by approx. 5 mm.
5. Hang the heating device onto the wall bracket using the
slots on the back of the unit (II).
6. Retighten the locking screws to secure the unit against
coming off inadvertently.
230
305
135
290
410
E L E K T R O G E R Ä T E
Top
H 260/1, H 260/2, H 261/1
2
4. Electrical Connection
The voltage information of the type plate must match the
present mains voltage.
Do not operate the heating device via an external switching
unit, e.g. via a clock timer. In addition, the heating device
must not be connected with a current circuit which is
switched on and off regularly. This may result in an
unwanted reset of the overheating protection (see also
Chapter 6).
If a wall socket must be installed or the connecting lead
needs to be replaced, this may only be done by skilled
electricians according to the applicable regulations.
5. Heating Operation
All models
The desired room temperature is set by turning the
thermostat knob clockwise. Heating operation is indicated
by an indicator lamp.
The lowest position on the thermostat is frost protection
.
In this setting, the thermostat switches the heating on at an
ambient temperature of approx. 5 °C.
Clock timer - model H 261/1
Turn the timer knob in a clockwise direction. Set the desired
time period (up to 60 minutes).
During the set time, the unit operates at the nominal output
of 2,000 W. The thermostat is not operational.
The set operating time can be interrupted or shortened at
any time by turning the timer knob in the counter-clockwise
direction.
Upon expiration of the set time period, the unit will
automatically switch to a heating output of 1,000 W. The
thermostat controls the set room temperature.
Thermostat
Indicator lamp
Timer
Model H 261/1
When the set time period has expired, a frost protection
function is activated. If the room temperature drops below
approx. 5 °C, the unit will switch on automatically with a
heating output of 1,000 W.
6. Protection against Overheating
For safety reasons, the heater is equipped with an
overtemperature protection feature. If the unit exceeds the
permissible temperature, it will be switched off
automatically. Disconnect the unit from the power supply in
such cases for several minutes. Pull the mains plug and let
the heating device cool down.
The unit can be restarted after rectifying the fault (e.g.
blocked or covered air screen).
7. Faults
In the event of faults, please contact your electrical retailer.
If required, you can also address your queries to the service
hotline of Glen Dimplex Germany GmbH.
Tel.: +49 (0) 9221 709-564
Fax: +49 (0) 9221 709 589
To process your order, please state the device type as well
as its production number (E No.) and manufacturing date
(FD).
This information is listed on the type plate.
Repairs and corrective measures may only be carried out
by skilled electricians or your after-sales service.
8. Cleaning the Device
Switch off the device and let it cool down before cleaning it.
Keep the air inlet opening (rear of unit) and the air outlet
opening (front of unit) free of dust. Remove dust
from the
exterior of the unit
using a vacuum cleaner.
Clean the outside of the unit using a soft, damp cloth and
dry it off. Do not use scouring powder or furniture polish as
this may damage the surface.
9. Warranty
This product is supplied with a two-year warranty according
to our terms of guarantee.
10. Note on Disposal
Do not dispose of the unit with general household
waste. The device must be taken to a local waste
disposal plant.
Glen Dimplex Deutschland GmbH Phone +49 (0)9221 709564 Subject to technical changes
Am Goldenen Feld 18 Telefax +49 (0)9221 709589 09/06/A
95326 Kulmbach, Germany E-mail: kundendienst.hauswaerme@glendimplex.de
www.glendimplex.de
  • Page 1 1
  • Page 2 2

AKO H 260/1 Datasheet

Type
Datasheet

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI