Airwell AWWR-WDF012-C12 User manual

Category
Split-system air conditioners
Type
User manual
PRECAUTION
Window WDF Series
Models: AWWR-WDF009-C11
AWWR-WDF012-C11
CONTENTS
CONTENTS
1.1 Safety Precaution. ..................................................................................................................................... 1
1.2 Warning ....................................................................................................................................................... 1
2. Specification. ................................................................................................................................................ 6
3. Dimension. .................................................................................................................................................... 7
4. Function and control panel. ........................................................................................................................ 8
4.1 Function. ..................................................................................................................................................... 8
4.2 Control panel. ............................................................................................................................................. 8
5. Refrigerant Cycle Diagram. ....................................................................................................................... 10
6. Wiring Diagram ...........................................................................................................................................11
7. Protection Function. .................................................................................................................................. 12
7.1 Proper symbols and their meaning ....................................................................................................... 12
7.2 Protection Function ................................................................................................................................. 12
7.2.1 Three minutes delay at restart for compressor. ...................................................................................... 12
7.2.2Anti-freezing protection at cooling or dry mode. ...................................................................................... 12
7.2.3 Anti-frosting protection and defect at cooling or dry mode. .................................................................. 12
7.2.4 Electronic function. ...................................................................................................................................... 13
7.3 Temperature sensor is open circuit or short circuit. .................................................................................. 14
8 Installation details ....................................................................................................................................... 15
8.1 Select the best location. .......................................................................................................................... 15
8.2 Check off installation............................................................................................................................... 16
8.3 How to drain. ............................................................................................................................................ 16
8.4 How to install. ........................................................................................................................................... 17
9 Operation characteristics .......................................................................................................................... 17
10 Characteristic of temperature sensor. .................................................................................................... 19
11 Troubleshooting ........................................................................................................................................ 20
12 Exploded view and part list ..................................................................................................................... 28
PRECAUTION
Window WDF 1 Version - 0
1. Precaution
1.1 Safety Precaution.
z To prevent injury to the user or other people and property damage, the following instructions
must be followed.
z Incorrect operation due to ignoring instruction will cause harm or damage.
Before service unit, be sure to read this service manual at first.
1.2 Warning
Installation
z Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit.
There is risk of fire or electric shock.
z For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized service
center.
Do not disassemble or repair the product, there is risk of fire or electric shock.
z Always ground the product.
There is risk of fire or electric shock.
z Install the panel and the cover of control box securely.
There is risk of fire of electric shock.
z Always install a dedicated circuit and breaker.
Improper wiring or installation may cause fore or electric shock.
z Use the correctly rated breaker of fuse.
There is risk of fire or electric shock.
z Do not modify or extend the power cable.
There is risk of fire or electric shock.
z Do not install, remove, or reinstall the unit by yourself(customer).
There is risk of fire, electric shock, explosion, or injury.
z Be caution when unpacking and installing the product.
Sharp edges could cause injury, be especially careful of the case edges and the fins on the condenser
PRECAUTION
Window WDF 2 Version - 0
and evaporator.
z For installation, always contact the dealer or an Authorized service center.
There is risk of fire, electric shock, explosion, or injury.
z Do not install the product on a defective installation stand.
It may cause injury, accident, or damage to the product.
z Be sure the installation area does not deteriorate with age.
If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and
personal injury.
z Do not let the air conditioner run for a long time when the humidity is very high and a door or a
window is left open.
Moisture may condense and wet or damage furniture.
z Take care to ensure that power cable could not be pulled out or damaged during operation.
There is risk of fire or electric shock.
z Do not place anything on the power cable.
There is risk of fire or electric shock.
z Do not plug or unplug the power supply plug during operation.
There is risk of fire or electric shock.
z Do not touch (operation) the product with wet hands.
There is risk of fire or electric shock.
z Do not place a heater or other appliance near the power cable.
There is risk of fire and electric shock.
z Do not allow water to run into electric parts.
It may cause fire, failure of the product, or electric shock.
z Do not store or use flammable gas or combustible near the product.
There is risk of fire or failure of product.
z Do not use the product in a tightly closed space for a long time.
Oxygen deficiency could occur.
z When flammable gas leaks, turn off the gas and open a window for ventilation before turn the
product on.
Do not use the telephone or turn switches on or off. There is risk of explosion or fire.
z If strange sounds, or small or smoke comes from product. Turn the breaker off or disconnect
PRECAUTION
Window WDF 3 Version - 0
the power supply cable.
There is risk of electric shock or fire.
z Stop operation and close the window in storm or hurricane. If possible, remove the product
from the window before the hurricane arrives.
There is risk of property damage, failure of product, or electric shock.
z Do not open the inlet grill of the product during operation. (Do not touch the electrostatic filter,
if the unit is so equipped.)
There is risk of physical injury, electric shock, or product failure.
z When the product is soaked (flooded or submerged), contact an Authorized service center.
There is risk of fire or electric shock.
z Be caution that water could not enter the product.
There is risk of fire, electric shock, or product damage.
z Ventilate the product from time to time when operating it together with a stove, etc.
There is risk of fire or electric shock.
z Turn the main power off when cleaning or maintaining the product.
There is risk of electric shock.
z When the product is not be used for a long time, disconnect the power supply plug or turn off
the breaker.
There is risk of product damage or failure, or unintended operation.
z Take care to ensure that nobody could step on or fall onto the outdoor unit.
This could result in personal injury and product damage.
CAUTION
z Always check for gas (refrigerant) leakage after installation or repair of product.
Low refrigerant levels may cause failure of product.
z Install the drain hose to ensure that water is drained away properly.
A bad connection may cause water leakage.
z Keep level even when installing the product.
To avoid vibration of water leakage
z Do not install the product where the noise or hot air from the outdoor unit could damage the
neighborhoods.
It may cause a problem for your neighbors.
PRECAUTION
Window WDF 4 Version - 0
z Use two or more people to lift and transport the product.
Avoid personal injury.
z Do not install the product where it will be exposed to sea wind (salt spray) directly.
It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins,
could cause product malfunction or inefficient operation.
Operational
z Do not expose the skin directly to cool air for long periods of time. (Do not sit in the draft).
This could harm to your health.
z Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a
consumer air conditioner, not a precision refrigerant system
There is risk of damage or loss of property.
z Do not block the inlet or outlet of air flow.
It may cause product failure.
z Use a soft cloth to clean. Do not use harsh detergents, solvents, etc.
There is risk of fire, electric shock, or damage to the plastic parts of the product.
z Do not touch the metal parts of the product when removing the air filter. They are very sharp.
There is risk of personal injury.
z Do not step on pr put anything on the product. (outdoor units)
There is risk of personal injury and failure of product.
z Always insert the filter securely. Clean the filter every two weeks or more often if necessary.
A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or
damage.
z Do not insert hands or other object through air inlet or outlet while the product is operated.
There are sharp and moving parts that could cause personal injury.
z Do not drink the water drained from the product.
It is not sanitary could cause serious health issues.
z Use a firm stool or ladder when cleaning or maintaining the product.
Be careful and avoid personal injury.
z Replace the all batteries in the remote control with new ones of the same type. Do not mix old
and new batteries or different types of batteries.
PRECAUTION
Window WDF 5 Version - 0
There is risk of fire or explosion.
z Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire.
They may burn of explode.
z If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do
not use the remote of the batteries have leaked.
The chemical in batteries could cause burns or other health hazards.
PRECAUTION
Window WDF 6 Version - 0
2. Specification.
Model AWWR-WDF009-C11 AWWR-WDF012-C11
Characteristics Units Cooling Cooling
Capacity
(1)
kW 2,6 3,3
Pdesign kW 2,6 3,3
SEER W/W 3,6 3,6
Energy efficiency class D D
Annual energy consumption kWh 253 321
Power supply V/Ph/Hz 220-240V/Single/50Hz 220-240V/Single/50Hz
Circuit breaker rating A 16 25,1
INDOOR
Fan type & quantity Cross flow fan x1 Cross flow fan x1
Fan speeds H/M/L RPM 890/810/730 870/800/670
Air flow
(3)
H/M/L m3/hr 380/350/310 490/450/400
External static pressure Min-Max Pa 0 0
Sound power level
(4)
H/M/L dB(A) 56 57
Sound pressure level
(5)
H/M/L dB(A) 49/47/45 49/47/45
Moisture removal l/hr 1 1,2
Condensate drain tube I.D mm
OUTDOOR
Refrigerant control Capillary Capillary
Compressor type, model Rotary Rotary
Air flow H/L m3/hr
Sound power level
(4)
H/L dB(A) 65 65
Sound pressure level
(5)
H/L dB(A) 58 58
Dimensions WxHxD mm 600x380x560 660x428x680
Weight kg 34 46
Package dimensions WxHxD mm 685x430x620 746x515x815
Packaged weight kg 36,7 50
Stacking height units 5 levels 5 levels
Refrigerant type R410A R410A
Refrigerant charge kg 0,48 0,6
Operation control type Remote control Remote control
DIMENSION
Window WDF 7 Version - 0
3. Dimension.
FUNCTION AND CONTROL
PANEL
Window WDF 8 Version - 0
4. Function and control panel.
4.1 Function.
Operation mode: Cooling, FanDry.
Fresh air switch.
LED display
Sleep mode
Swing function.
Self-diagnosis function
Timer function.
Anti-freezing control in cooling mode or drying mode. Prevent the water being freezed on
evaporator by sensing the evaporator pipe temperature in cooling mode.
Time Delay Safety. Restarting is for approx. 3 minutes.
Auto-restart. When the power supply is interrupted and then restore, the air conditioners
automatically restore the previous function setting.
4.2 Control panel.
1】ON/OFF OPERATION BUTTON
This button turns the air conditioner ON and OFF.
FUNCTION AND CONTROL PANEL
Window WDF 9 Version - 0
2】SWING BUTTON
Press the “SWING” keypad(for the models with swing feature only) to activate the automatic air swing
feature.
To stop the air swing feature, press the “SWING” keypad again.
Press the “SWING” keypad for 2 seconds will activate the SLEEP mode which can reduce noise creating
a comfortable sleeping.
3】TIMER BUTTON
Press the “TIMER” keypad to activate the “auto start/auto stop” timer function.
Auto Start/Stop programs can be from 0-12 hours. Each depression of the “TIMER” keypad will increase
the selected time in 1 hour increments.
4】FAN SPEED BUTTON
Press the button to select the low, Middle and High FAN Speed.
5】TEMP BUTTON
Press the keypad to increase the set (operating) temperature of the unit and press the keypad to
decrease the set(operating) temperature of the unit. The temperature setting range is from 16-31.
6】MODE BUTTON
Press the “MODE” keypad to select the appropriate operating mode. For the Cooling & Heating models,
the mode selection will alternate between COOLING, FAN, DRY.
7】SIGNAL RECEIVER
FUNCTION AND CONTROL
PANEL
Window WDF 10 Version - 0
5. Refrigerant Cycle Diagram.
The figure below is a brief description of the important components and their function in what is
called the refrigeration system.
This will help to understand the refrigeration cycle and the flow of the refrigerant in the cooling cycle.
F or o n ly c o o ling
L IQ U ID S ID E
GAS SIDE
EVAPORATOR
CONDENSER
COMPRESSOR
CAPILIARY TUBE
WIRING DIAGRAM
Window WDF 11 Version - 0
6. Wiring Diagram
PROTECTION FUNCTION
Window WDF 12 Version - 0
7. Protection Function.
7.1 Proper symbols and their meaning
T1: Indoor ambient temperature
T2: Indoor evaporator temperature
T3: Outdoor condenser temperature
Ts: Setting temperature through the remote controller
7.2 Protection Function
7.2.1 Three minutes delay at restart for compressor.
7.2.2 Anti-freezing protection at cooling or dry mode.
Anti-freezing control according to T2 (Indoor evaporator temperature).
If the evaporator pipe temperature had been lower than 1 for 14 minutes, the evaporator
anti-freezing protection will be activated. The compressor will keep off in the following 5 minutes
5 minutes later, if the evaporator pipe temperature is still lower than 4, the compressor will stay off.
Otherwise the compressor will be started and the function is cancelled.
Anti-freezing control according to TIME.
If the lasting time of compressor which is continuously running has got to 105 minutes with fan
motor operating under Med or Low speed and the indoor ambient temperature lower than 26, the
anti-freezing function will be activated. The compressor will keep off for 3 minutes.
Note:
If the compressor stops operation, the time will be cleared.
7.2.3 Anti-frosting protection and defect at cooling or dry mode.
3 minutes later when compressor is running, if T2 has been less than -14 for subsequent 3
minutes, the anti-frosting protection is activated and compressor will stop in the following 6 minutes.
After that, if the condition for de-frosting function is met again in the following 10 minutes while the
compressor is operating, the unit will display ‘Ed to indicate that the unit is in the de-frost defect.
PROTECTION FUNCTION
Window WDF 13 Version - 0
The compressor and fan motor will be OFF
Note:
The Defect display can be cancelled only by pressing the ON/OFF button on the unit or the remote
controller.
7.2.4 Electronic
function.
7.2.4.1 Cooling mode
The speed of indoor fan can be
optionally chosen as High/ Mid (optional)
/Low
Compressor running rules:
T1>TS+2°F, compressor on
T1TS-2°F, compressor off
7.2.4.2 Auto mode
The machine will choose cooling, fan-only mode according to ΔT (ΔT =T1-Ts).
(T1-Ts)
2
-2
Operation conditon
compressor off
compressor on
PROTECTION FUNCTION
Window WDF 14 Version - 0
ΔT=T1-Ts Running mode
ΔT2
Cooling
-1≤ΔT2
Fan-only
The machine will choose actual running mode in auto mode in the below cases:
¾ Power on or change mode to auto mode or adjust temperature in auto mode, the machine will
choose actual running mode again.
¾ A: In auto mode, if the compressor keeps not running for 15 minutes. judge condition B
B: If 1<ΔT or ΔT <-4, the machine will choose actual running mode again according to T1-Ts till
the compressor stops..
7.2.4.3 Fan mode
(1) Compressor stops.
(2) Temperature setting function is disabled.
(3) The speed of indoor fan can be optionally chosen as High/ Mid /Low.
7.3 Temperature sensor is open circuit or short circuit.
Defect code malfunction explanation
Er
Room temperature sensor error.
En
Evaporator temperature sensor error.
Eo
Condenser temperature sensor error.
Ed
Evaporator de-frosting defect.
Malfunction display:
When the malfunction happened at the same time, the priority is: Er> En> E0>Ed
INSTALLATION
Window WDF 15 Version - 0
8 Installation details
8.1 Select the best location.
1. To avoid vibration and noise, make sure the unit is installed securely and firmly.
2. Install the unit where the sunlight does not shine directly on the unit. If the unit receives.
direct sunlight, build an awning to shade the cabinet.
3. There should be no obstacle, such as a fence or wall, within 500mm from the back of the
ambient because it will prevent heat radiation of the condenser.
4. Restriction of outside air will greatly reduce the cooling and heating efficiency of the air
Conditioner.
5. Install the unit on a slight angle so that an condensate formed will not enter the room
(about 10mm or 1/4”bubble with level).
6. Install the unit with its bottom portion 75~1500mm above the floor level.
7. The power cord must be connected to an independent circuit. The yellow/green wire must
be grounded.
INSTALLATIOIN
Window WDF 16 Version - 0
8.2 Check off installation.
¾ The setting conditions must be checked prior to initial starting. The under mentioned items are
especially important checking points when the installation is finished.
¾ Grounding wire (yellow/Green) is provided in the power cord. The wire must be grounded.
¾ Ensure that the unit is connected to a suitably rated and dedicated circuit.
¾ To avoid vibration or noise, make sure the air conditioner is installed securely.
¾ Avoid placing furniture of draperies in front of the air inlet and outlet.
8.3 How to drain.
To get the maximum cooling efficiency, the air conditioner is designed to splash the
condensation water on the condenser coil.
If the splashing sound annoys you, you can provide an outside drain by using the following
procedure, which may however cause a small loss of performance.
1. Slide out the chassis from the cabinet.
2. Remove the rubber plug from the body base plate.
3. Install the drain pan to the corner of the cabinet with 2 screws.
4. Connect the drain hose to the outlet on the drain pan bottom.
5. Slide the chassis into its original place in the cabinet.
INSTALLATION
Window WDF 17 Version - 0
8.4 How to install.
9 Operation characteristics
1) Remove the sticker from the front panel.
2) Put the unit into the installation hole.
When installing the unit, it should be
slanted down to the back to avoid the
enlargement of noise or vibration.(Slant
between 6-10mm.)
The installation place should be strong
enough to avoid the enlargement of noise
or vibration.
3) Fill up sews in the cabinet with sponge or
foam.
z Use iron support
The installation hole should be strong
enough to support the air conditioner. If
it cannot, iron support has to be used
outdoors.
Iron support should be fixed on the
building.
z Use sunshade board
Air conditioner should avoid anything to
be dropped into it and avoid direct
sunshine. If there is no cover on it, you
should contact the seller for installing the
sunshade board. When installing the
sunshade board, don’t let it block the air
at the side grille.
INSTALLATIOIN
Window WDF 18 Version - 0
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35

Airwell AWWR-WDF012-C12 User manual

Category
Split-system air conditioners
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI