8
How to turn the power on and off
pwTurning the power on
When performing the operations
using the wireless remote control
1 Set all the power switches of the units and
devices connected in the system to ON.
p This unit does not have a power switch.
When power is supplied to it, the status display lamp
will light up orange.
The initial operation is then performed, and after this
the unit is set to the standby mode.
2 Press one of the [CAM1] to [CAM4] buttons on
the wireless remote control to select the unit.
3 Press the [ON/STANDBY] button on the
wireless remote control for 2 seconds.
The POWER ON mode is established, images are
output, and control can be exercised.
p The unit’s status display lamp now lights up green.
p It takes about 30 seconds per unit for the initial
settings operation to be completed. During this
period, the unit cannot be operated.
(Status display lamp: light up orange)
p When transferring to the STAND BY mode
(Status display lamp: Orange)
The pan/tilt position is stored in the memory, and
the pan/tilt unit is moved so that it points backwards.
p When transferring to the POWER ON mode
(Status display lamp: Green (after the initial setting
operation is completed))
The pan/tilt unit is moved to the position which was
stored in the memory when the transition to the
STAND BY mode was made.
p POWER ON preset
The pan/tilt unit is moved to the setting, which was
established immediately prior to the transition to the
STAND BY mode, when the power has been turned
on.
p If the power is turned off without transferring to the
STAND BY mode, the pan/tilt unit position will not
be stored in the memory or reflected in the POWER
ON preset. The zoom position is stored using the
setting established immediately before the power is
turned off.
Notes
4 If a multiple number of units are going to be
used, repeat steps
2 and 3 as required.
The unit’s status display lamp blinks green when a signal
matched by the remote control ID has been received, and
it blinks orange when a signal that is not matched by the
remote control ID has been received.
When performing the operations using the controller
When the AW‑RP655 or AW‑RP555 is connected:
1 Set all the power switches of the units and
devices connected in the system to ON.
p This unit does not have a power switch.
When power is supplied to it, the status display lamp
will light up orange.
The initial operation is then performed, and after this
the unit is set to the standby mode.
2 Set the [OPERATE] switch on the controller to
ON.
The POWER ON mode is established, images are
output, and control can be exercised.
p The unit’s status display lamp now lights up green.
p It takes about 30 seconds per unit for the initial
settings operation to be completed. During this
period, the unit cannot be operated.
(Status display lamp: light up orange)
p When transferring to the STAND BY mode
(Status display lamp: Orange)
The pan/tilt position is stored in the memory, and
the pan/tilt unit is moved so that it points backwards.
p When transferring to the POWER ON mode
(Status display lamp: Green (after the initial setting
operation is completed))
The pan/tilt unit is moved to the position which was
stored in the memory when the transition to the
STAND BY mode was made.
p POWER ON preset
The pan/tilt unit is moved to the setting, which was
established immediately prior to the transition to the
STAND BY mode, when the power has been turned
on.
p If the power is turned off without transferring to the
STAND BY mode, the pan/tilt unit position will not
be stored in the memory or reflected in the POWER
ON preset. The zoom position is stored using the
setting established immediately before the power is
turned off.
Notes
Before setting the [OPERATE] switch on the controller to ON,
be absolutely sure to set all the power switches of the units
and devices connected in the system to ON.
For further details, refer to the Operating Instructions of the
controller.
When the AW‑RP50 is connected:
Refer to the Operating Instructions of the controller.