2
Notes on using the manual
3
1 2 3 4
4
4 3 26
5
5a
5b
5c
1
3
ECO Vent Filter Notes on using the manual
4
4
ECO Vent FilterNotes on using the manual
Table of contents
1 Notes on using the manual .................................................4
2 General safety instructions .................................................5
3 Intended use ............................................................5
4 Installation ...........................................................5 - 6
5 Warranty ............................................................6 - 7
6 Customer service.........................................................7
1 Notes on using the manual
Caution!
Safety Instruction: Failure to observe this instruction can cause material damage and
impair the function of the device.
Note
Supplementary information for operating the device.
fig. 1, p. 2 : This refers to an element in an illustration. In this example, item 1 in
gure 2 on page 2.
2
EN
5
ECO Vent Filter General Safety Instructions
2 General safety instructions
The manufacturer will not be held liable for claims for damage resulting from the following:
Faulty assembly or connection
Damage to the unit from mechanical inuences
Alterations to the unit without express written permission from the manufacturer
Use for purposes other than those described in the operating manual
3 Intended use
When a toilet is ushed on a boat with a holding tank, air is pushed out of the holding tank, through
a vent hose, and out of the boat through a vent tting. To stop foul-smelling air from coming out of
the vent tting, install an ECO Vent Filter.
4 Installation
Remove old filter (if replacing existing vent lter)
1. Remove vent hose from both ends of old vent lter. If old vent lter was connected to threaded
ttings for 5/8-in./16 mm or 3/4-in./19 mm ID hose, those ttings should remain attached to vent
hose.
2. Remove old lter from bracket and seal ends with adhesive tape.
3. Discard old lter in appropriate container.
Install filter
NEW INSTALLATION
1. Select location for vent lter. Avoid areas near excessive heat sources (engine manifolds,
lights, etc.). Do not install lter below top of holding tank (g.
1
p. 2).
2. Vent lter can be mounted at any angle. Installations near thru-hull vent reduce chance of lter
damage from potential overlling of tank.
3. Install mounting bracket (g.
2
1, p. 2) with screws (g.
2
2, p. 2).
4. Lightly lubricate O-rings on each end of lter cartridge with silicone grease.
5. Remove red plugs from each end.
6. After vent hose ID is chosen, attach correct size hose adapters (g.
3
5b or 5c, p. 2) to lter
cartridge with retaining fasteners (g.
3
4, p. 2). Be sure to push hose adapters completely
over O-rings before threading the retaining fasteners to the lter. Refer to Adapter Size Chart
below to identify correct size hose adapter.
7. Press ECO vent lter (g.
3
6, p. 2) into mounting bracket so that it clicks into bracket arms.
8. Route vent hose from waste holding tank and thru-hull tting to ECO vent lter. Using hose
clamps (not included), attach vent hoses to adapters that are connected to vent lter.
Ref. Description
4 Retaining fasteners
5a threaded adapters for 5/8-in. or
3/4-in. ID hose threaded ttings
5b 5/8-in.+3/4-in. ID hose adapters
5c 1-in.+1.5-in. ID hose adapters
Adapter Size Chart (g.
3
, p. 2)
Hose adapter
connection zones for:
5/8 in./16 mm ID hose
3/4 in./19 mm ID hose
1 in./25 mm ID hose
1.5 in./38 mm ID hose
5b
5c
6
ECO Vent Filter
Installation / Warranty
5 Warranty
North America and Rest of the World:
Manufacturer’s One-Year Limited Warranty
Dometic Corporation, Sanitation Division warrants to the original purchaser only that this product,
if used for personal, family or household purposes, is free from defects in material and workman-
ship for a period of one year from the date of purchase.
If this Dometic product is placed in commercial or business use, it will be warranted to the original
purchaser to be free of defects in material and workmanship for a period of only ninety (90) days
from the date of purchase.
(continued on next page)
REPLACING OLD SEALAND OR DOMETIC VENT FILTER
For installations with 5/8-inch or 3/4-inch (16 mm or 19 mm) ID hose threaded fittings (g.
3
3, p. 2) already attached to vent hose:
1. Make sure rubber gaskets (not provided) are inside threaded ttings at hose ends.
2. Lightly lubricate O-rings on each end of lter cartridge with silicone grease.
3. Remove red plugs from each end of lter cartridge.
4. Use retaining fasteners (g.
3
4, p. 2) to attach threaded adapters (g.
3
5a, p. 2) to each
end of lter cartridge. Be sure to push hose adapters completely over O-rings before threading
the retaining fasteners to the lter.
5. Press ECO vent lter (g.
3
6, p. 2) into mounting bracket so that it clicks into bracket arms.
6. Attach threaded hose ttings to threaded adapters (g.
3
5a, p. 2) on lter cartridge. Tighten
1/4 to 1/2 turn beyond hand tight.
For installations with 5/8-inch, 3/4-inch, 1-inch or 1.5-inch ID vent hose and clamped
connection to vent filter:
1. Lightly lubricate O-rings on each end of lter cartridge with silicone grease.
2. Remove red plugs from each end of lter cartridge.
3. Use retaining fasteners (g.
3
4, p. 2) to attach correct size hose adapters (g.
3
5b or 5c, p.
2) to lter cartridge. Be sure to push hose adapters completely over O-rings before threading
the retaining fasteners to the lter. Refer to Adapter Size Chart (p. 3) to identify correct size
hose adapter to use with existing vent hose ID size.
4. Press ECO vent lter (g.
3
6, p. 2) into mounting bracket so that it clicks into bracket arms.
5. Using hose clamps (not included), attach vent hoses to adapters that are connected to vent
lter.
Caution!
Do not use ECO Vent Filter for holding tanks with waste that is treated through on-
board sewage treatment systems that use chlorine or other strong oxidizing agents.
Caution!
Replace vent lter immediately if accidental overow of holding tank occurs.
Note
Replace vent lter at the beginning of each boating season for best odor control.
7
ECO Vent Filter Warranty / Customer Service
Dometic reserves the right to replace or repair any part of this product that proves, upon
inspection by Dometic, to be defective in material or workmanship. All labor and transportation
costs or charges incidental to warranty service are to be borne by the purchaser-user.
EXCLUSIONS
IN NO EVENT SHALL DOMETIC BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES,
FOR DAMAGES RESULTING FROM IMPROPER INSTALLATION, OR FOR DAMAGES CAUSED
BY NEGLECT, ABUSE, ALTERATION OR USE OF UNAUTHORIZED COMPONENTS. ALL IMPLIED
WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS
FOR ANY PARTICULAR PURPOSE, ARE LIMITED TO A PERIOD OF ONE YEAR FROM DATE OF
PURCHASE.
IMPLIED WARRANTIES
No person is authorized to change, add to, or create any warranty or obligation other than that
set forth herein. Implied warranties, including those of merchantability and tness for a particular
purpose, are limited to one (1) year from the date of purchase for products used for personal,
family or household purposes, and ninety (90) days from the date of purchase for products placed
in commercial or business use.
OTHER RIGHTS
Some states do not allow limitations on the duration of an implied warranty and some states do
not allow exclusions or limitations regarding incidental or consequential damages; so, the above
limitations may not apply to you. This warranty gives you specic legal rights, and you may have
other rights which vary from state to state.
To obtain warranty service, rst contact your local dealer from whom you purchased this product
or go to http://www.dometic.com for a dealer near you.
6 Customer service
Contact information
There is a strong, worldwide network to assist in servicing and maintaining your toilet system.
For the Authorized Service Center near you, please call from 8:00 a.m. to 5:00 p.m. (ET) Monday
through Friday.
You may also contact or have your local dealer contact the Parts Distributor nearest you for quick
response to your replacement parts needs. They carry a complete inventory for the Dometic prod-
uct line.
Telephone: 1 800-321-9886 U.S.A. and Canada
330-439-5550 International
Fax: 330-496-3097 U.S.A. and Canada
330-439-5567 International
Web site: Dometic.com
18
REVISION A
Form No. 600347170 7/17
©2017 Dometic Corporation
Dometic Corporation, Sanitation Division
13128 State Rt. 226, P.O. Box 38
Big Prairie, OH 44611 USA
1-800-321-9886 • Fax: 330-496-3097
www.Dometic.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

Dometic ECO Holding Tank Vent Filter User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI