Installation instructions
CONNECTING THE DRYERTO HOUSEVENT
RIGIDMETALTRANSITIONDUCT
* Forbest drying performance,a rigid metal transition duct is
recommended.
, Rigidmetal transitions ducts reducethe riskof crushingand
kinking.
UL-LISTEDFLEXIBLEMETAL(SEMI-RIGID}TRANSITIONDUCT
tfrigid metalduct cannot beused,then UL-listedflexiblemetal
(semi-rigid)ducting can beused(KitWX08X!0077).
Neverinstallflexiblemetal duct in walls,ceilings,floorsor oth-
erenclosedspaces.
Total length of flexible metal duct should not exceed8 feet
(2.4m).
For many applications, installing elbows at both the dryer
and the wall is highlyrecommended(seeillustrations below).
Elbowsallowthe dryerto sit closeto the wall without kinking
and or crushing the transition duct, maximizing drying
performance.
Avoidrestingthe duct on sharpobjects.
UL-LISTEDFLEXIBLEMETAL(FOIL-TYPE}TRANSITIONDUCT
, tn special installations, it may be necessaryto connect the
dryerto the housevent usinga flexible metal (foil-type)duct.
A UL-listedflexible metal (foil-type)duct may be usedONLY
in installationswhere rigid metal or flexiblemetal (semi-rigid)
ducting cannot be used AND where a 4" diameter can be
maintainedthroughout theentirelengthof thetransitionduct.
tnCanadaand the United States,only the flexible metal (foil-
type) ducts that comply with the "Outlinefor ClothesDryer
TransitionDuctSubject2158A"shallbe used.
, Never install flexible metal duct in walls, ceilings,floors or
otherenclosedspaces.
Total length of flexible metal duct should not exceed8 feet
(2.4m).
, Avoidrestingthe duct onsharpobjects.
, Forbestdryingperformance:
1.Slideoneend ofthe duct overthe clothesdryeroutlet pipe.
2.Securetheduct with a clamp.
3.With the dryerin its permanentposition,extendthe duct to
its full length.Allow2" of duct to overlapthe exhaustpipe.
Cut off and removeexcessduct. Keepthe duct as straight
aspossiblefor maximumairflow.
4.Securetheduct to the exhaustpipewith theother clamp.
ELBOW
RECOMMENDED
__S HIGHLY
RECOMMENDED
EXCESSIVE
EXHAUST _)LENG_ DO NOT
CRUSH
FLEXIBLE
EXHAUST
AGAINST
ALCOVE OR CLOSET INSTALLATION
• tfyour dryerisapprovedfor installationin an alcoveor closet,
itwill bestatedon a labelon the dryerback.
ThedryerMUSTbevented to the outdoors.Seethe EXHAUST
INFORMATIONsections3 &/4.
Minimumclearancebetweendryercabinetandadjacent walls
or other surfacesis:
0 in.eitherside
3 in.front and rear
Minimum vertical space from floor to overhead cabinets,
ceiling,etc.is 52in.
Closet doors must be Iouvered or otherwise ventilated and
must contain a minimum of 60 sq. in. of open area equally
distributed, tf the closetcontains both a washer and a dryer,
doors must contain a minimum of 120 sq. in. of open area
equallydistributed.
F7-1BATHROOM OR BEDROOM INSTALLATION
. Thedryer MUSTbe vented to the outdoors. SeeEXHAUST
iNFORMATIONsection 3 &/4.
The installation must conform with local codes or, in the
absence of local codes, with the NATIONAL ELECTRICAL
CODE,ANSI/NFPA NO. 70.
FS]MOBILE OR MANUFACTURED HOME
INSTALLATION
• installation MUSTconform to the MANUFACTUREDHOME
CONSTRUCTION& SAFETYSTANDARD,TITLE24, PART32-
80 or,when suchstandard isnot applicable,with AMERICAN
NATIONALSTANDARDFORMOBILEHOME,ANSI/NFPANO.
501B.
• ThedryerMUSTbeventedtotheoutdoorswith thetermination
securelyfastenedtothe mobilehomestructure.(SeeEXHAUST
INFORMATIONsection3 &4).
The vent MUSTNOT be terminated beneath a mobile or
manufactured home.
Thevent duct material MUSTBEMETAL.
Do not use sheet metal screws or other fastening devices
which extendintothe interiorof theexhaustvent.
Seesection2for electricalconnectioninformation.
5