FMI STL-12D Operating instructions

Category
Fireplaces
Type
Operating instructions

This manual is also suitable for

FMI STL-12D is a square top termination designed to be used with chimney systems. It features a 16.5" diameter hole with a 2" collar, allowing it to fit over the end of a chimney pipe. The termination cap is secured with sheet metal screws, ensuring a tight and durable fit.

The FMI STL-12D is made of 28 gauge galvanized steel, making it resistant to rust and corrosion. It also includes noncombustible spacers to prevent heat transfer from the chimney to the surrounding chase.

The termination cap is designed to comply with the "10 Foot Rule," which requires the chimney flue gas outlet to be a minimum of 3 feet above the highest point where the pipe penetrates the roof and 2 feet above the highest point of the roof within a horizontal distance of 10 feet. This ensures that harmful gases are properly vented away from the home.

FMI STL-12D is a square top termination designed to be used with chimney systems. It features a 16.5" diameter hole with a 2" collar, allowing it to fit over the end of a chimney pipe. The termination cap is secured with sheet metal screws, ensuring a tight and durable fit.

The FMI STL-12D is made of 28 gauge galvanized steel, making it resistant to rust and corrosion. It also includes noncombustible spacers to prevent heat transfer from the chimney to the surrounding chase.

The termination cap is designed to comply with the "10 Foot Rule," which requires the chimney flue gas outlet to be a minimum of 3 feet above the highest point where the pipe penetrates the roof and 2 feet above the highest point of the roof within a horizontal distance of 10 feet. This ensures that harmful gases are properly vented away from the home.

36"
Minimum
3"
Minimum
2"
Minimum
Square Top TerminaTionS
INSTALLATION INSTRUCTIONS
ETL-12D, ETL-12DMP, STL-12D AND STL-12DMP
1. Construct chase as illustrated in Figure 1.
Note: The shortest vertical side must be at least 30" high
and minimum inside dimension must be at least 19" as
shown in Figure 1.
2. Addpipesectionstochimneysystemasoutlinedinre-
place installation instructions until last piece of chimney
is a maximum of 6" below top of chase (see Figure 1).
3. Fabricateaashinghavinga16.5"diameterholecen-
teredoverchimneyendwitha2"collararoundhole(see
Figure 2). Attach noncombustible spacers at each corner
andplaceashingoverchase.
4. Secureashingthroughsideswith8-pennynailsorsheet
rock screws.
5. Place galvanized sleeve through hole in ashing and
around last section of chimney (see Figure 3).
6. Place termination cap over opening and slip stainless
steel inner pipe into stainless steel chimney section.
Lowerterminationassemblyuntilcaprestsevenlyover
ashinghole.Securecapateachcornerwithsheetmetal
screws (see Figure 4).
Figure 1 - Constructing Chase
Figure 2 - Constructing Chase Top Flashing
Figure 3 - Installing Termination Cap
Figure 4 - Securing Termination to Chase Top Flashing with
Sheet Metal Screws
As Required
28GaugeGalvanizedSteel
2" Collar
1" Noncombustible Spacer
Chase Top
Chase Facia
10 Foot Rule
Thechimneyuegasoutletofterminationmustbeamini-
mumdistanceof3feetabovethehighestpointwherepipe
penetrates the roof and must be a minimum distance of 2 feet
abovehighestpointoftheroofwithinahorizontaldistanceof
10feet(seeFigure5).
19"
Minimum
6" Maximum
30" Minimum
Termination
Cap
1" Spacer
Note: Do Not
Seal Ventilation
Openings
Screw
Galvanized
Sleeve
NOTAUPC
Figure 5 - 10 Foot Rule
Level of Flue
Gas Outlet
3' Min.
10'
or Less
2' Min.
Termination
16.5"Diameter
Sheet Metal Screw
110307 01
110307-01
Rev.E
05/08
DESAHeating,LLC
2701IndustrialDrive
BowlingGreen,KY42101
www.desatech.com
1-866-672-6040
Note: Do Not
Seal Ventilation
Openings
1" Space
1/4"Screen
  • Page 1 1

FMI STL-12D Operating instructions

Category
Fireplaces
Type
Operating instructions
This manual is also suitable for

FMI STL-12D is a square top termination designed to be used with chimney systems. It features a 16.5" diameter hole with a 2" collar, allowing it to fit over the end of a chimney pipe. The termination cap is secured with sheet metal screws, ensuring a tight and durable fit.

The FMI STL-12D is made of 28 gauge galvanized steel, making it resistant to rust and corrosion. It also includes noncombustible spacers to prevent heat transfer from the chimney to the surrounding chase.

The termination cap is designed to comply with the "10 Foot Rule," which requires the chimney flue gas outlet to be a minimum of 3 feet above the highest point where the pipe penetrates the roof and 2 feet above the highest point of the roof within a horizontal distance of 10 feet. This ensures that harmful gases are properly vented away from the home.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI