Astria Fireplaces WRT40ST Instruction Sheet

Type
Instruction Sheet
www.IHP.US.com 126750-01A1
127137-01 Rev. A 03/14
1508 Elm Hill Pike, Suite 108
Nashville, TN 37210
www.IHP.US.com
P127137-01
36"
Minimum
3"
Minimum
2"
Minimum
SQUARE TOP TERMINATIONS
INSTALLATION INSTRUCTIONS
ETL-12D, ETL-12DMP, STL-12D AND STL-12DMP
1. Construct chase as illustrated in Figure 1.
Note: The shortest vertical side must be at least 30" high
and minimum inside dimension must be at least 19" as
shown in Figure 1.
2. Add pipe sections to chimney system as outlined in -
place installation instructions until last piece of chimney
is a maximum of 6" below top of chase (see Figure 1).
3. Fabricate a having a 16.5" diameter hole cen-
tered over chimney end with a 2" collar around hole (see
Figure 2). Attach noncombustible spacers at each corner
and place over chase.
4. Secure through sides with 8-penny nails or sheet
rock screws.
5. Place galvanized sleeve through hole in and
around last section of chimney (see Figure 3).
6. Place termination cap over opening and slip stainless
steel inner pipe into stainless steel chimney section.
Lower termination assembly until cap rests evenly over
hole. Secure cap at each corner with sheet metal
screws (see Figure 4).
Figure 1 - Constructing Chase
Figure 2 - Constructing Chase Top Flashing
Figure 3 - Installing Termination Cap
Figure 4 - Securing Termination to Chase Top Flashing with
Sheet Metal Screws
As Required
28 Gauge Galvanized Steel
2" Collar
1" Noncombustible Spacer
Chase Top
Chase Facia
10 Foot Rule
The chimney gas outlet of termination must be a mini-
mum distance of 3 feet above the highest point where pipe
penetrates the roof and must be a minimum distance of 2 feet
above highest point of the roof within a horizontal distance of
10 feet (see Figure 5).
19"
Minimum
6" Maximum
30" Minimum
Termination
Cap
1" Spacer
Note: Do Not
Seal Ventilation
Openings
Screw
Galvanized
Sleeve
NOT A UPC
Figure 5 - 10 Foot Rule
Level of Flue
Gas Outlet
3' Min.
10'
or Less
2' Min.
Termination
16.5" Diameter
Sheet Metal Screw
110307 01
110307-01
Rev. E
05/08
DESA Heating, LLC
2701 Industrial Drive
Bowling Green, KY 42101
www.desatech.com
1-866-672-6040
Note: Do Not
Seal Ventilation
Openings
1" Space
1/4" Screen
STL-12D and STL-12DMP
  • Page 1 1

Astria Fireplaces WRT40ST Instruction Sheet

Type
Instruction Sheet