B E F O R E Y O U S T A R T
Proper installation is your responsibi lity.
Installations must be performed by a
qualified or licensed contractor, plumber or
gas fitter, qualified or li censed by the state,
province or region where this applian ce is
being installed. You must also ensure that
electrical insta llation i s adequate and
conforms with all local codes and
ordinan ces.
Proper gas supply must be a vailable; refer
to gas supply requirements on page 9.
Electri cal ground is requi
red; see electrical
requirements on page 10.
Check the location where the range will be
installed. The location should be away from
strong draft areas, such as windows, doors
and strong heating vents or fans. Do not
obstruct the flow of ai r. The area in whi ch
you are installing this appliance must have
an adequate supply of fresh air to ensure
proper combustion and ventilation.
Make sure you have everything necessary
for proper installation. It is the responsibil-
ity of the i
nstaller to comply with the instal-
lation clearances specified on the product
rating plate. The rating plate is located rear
of removable lo wer panel.
All openings in the wall or floor where the
range is to be installed must be se aled.
The cooking ran ge to be installed only on
the floor.
When installing the range under existing
cabinets where the installation does not
meet the minimum cabinet clearances,
install a ventilation hood or other non-
combustible surface above th
e range to
avoid burn hazards. R efer to minimum
clearances on page 3.
V E N T I L AT I O N O P T I O N S
IMPORTANT NOTE:
A suitable ventilation
hood must be installed. We recommend a Wolf
Pro Ventilation Hood be installed with the Wolf
dual Fuel Range. Contact your Wolf dealer for
details.
IMPORTANT NOTE:
When installing a ventila-
tion hood, refer to the specific requirements
of the hood for the minimum dimension to
countertop.
I N S TA L L AT I O N S P E C I F I C A T I O N S
Wolf dual fuel ranges come in 762 mm,
914 mm, 1219 mm and 1524 mm wi dths.
Illustrations on pages 4–
7 provide the overall
dimensions and installation specifications for
each width of dual fuel range.
Each range is designed to f it between cabinets
set at the distance specified by the unit. For
example, a 914 mm range will fit a 914 mm
opening. The exception is the 1524 mm un it
which will require a 1530 mm opening.
IMPORTANT NOTE:
Cabinet opening dimen-
sions shown in the installation specifications
illustrations must be used. These dimensions
provide for required clearanc
es.
Each unit is designed with a terminal block on
the rear of the range. Have a qualified electri-
cian or install er wire your unit from the electri-
cal supply, through the knockout in the unit
base and to the terminal block on the range.
IMPORTANT NOTE:
Locate the electrical
supply within dimensions shown in the
installation specifications illustrations and
flush with back wall.
Refer to the instal lation specifications illustra-
tion for your model on pages 4–7 for the ex
act
rough opening dimensions and location of the
gas supply and electrical.
Wolf dual fuel ranges using natural gas will
operate up to an altitude o f 2438 m without
any adjustment. Natural gas and LP gas instal-
lations from 2438 m to 3353 m need the high
altitude conversion kit.
I N S TA L L AT I O N I N S T R U C T I O N S
I N S TA L L AT I O N S P E C I F I C A T I O N S
M I N I M U M C L E A R A N C E S
IMPORTANT NOTE:
Caution must be use d in
planning the proper installation of the Wolf
dual fuel range to avoid fire or damag
e to
adjacent cabinetry or kitchen equipment.
Be sure to follow the minimum clearances
established in the finished rough opening
dimensions.
For insta llation against a rear combustible
surface a 25 4 mm classic stainless steel riser
must be used. Refer part nu mber 804387.
Refer to the installation specificatio ns illust ra-
tion for your model on pages 4–7 for the ex act
rough opening dimensions.
Maintain the following clearances to
combustible materials:
Minimum 457 mm clearance from bottom
of upper cabine t to countertop, within
152 mm minim um side clearance.
Minimum 762 mm clearance between coun-
tertop and bottom of wood or metal
cabinet, which is protected by not less than
6 mm flame retardant millboard covered
with not less than No. 28 MSG sheet steel,
.4 mm stainless steel , or .6 mm aluminum
or .5 mm copper.
Minimum 914 mm clearance between coun-
tertop and bottom of an unprotected wood
or metal cabinet.
Bottom of ventilation hood m ust be
600 mm minimum to 914 mm m aximum
from countertop.
I S L A N D | P E N I N S U L A I N S T A L L A -
T I O N S
For island installations,
the range should
not be installed within an enclosure having an
adjacent rear wall less than 305 mm from the
rear of the unit that rises above the counte rtop.
For peninsula installations,
the range must
have a 152 mm minimum clearance to the side
wall, left or right side, and 305 mm minimum
clearance to the rear wall.
Refer to the installation specificatio ns illustra-
tion for your model on pages 4–7 for the exact
rou
gh opening dime nsions.
Failure to locate the range without the
proper clearances will result in a fire
hazard.