ES-A-C300/C300N
Features
• ExtremelyCompactDesign
• 70%LighterthanTraditional
Designs
• 304(Schedule40)StainlessSteel
Housing&Sleeve
• GrooveFittingsAllowIntegral
PipelineAdjustment
• PatentedTri-LinkCheckProvides
LowestPressureLoss
• UnmatchedEaseofServiceability
• AvailablewithGroovedButterfly
ValveShutoffs
• MaybeUsedforHorizontal,
VerticalorNPatternInstallations
• ReplaceableCheckDiscRubber
Job Name ________________________________________________ Contractor ______________________________________________
Job Location ______________________________________________ Approval _______________________________________________
Engineer _________________________________________________ Contractor’s P.O. No. ______________________________________
Approval _________________________________________________ Representative ___________________________________________
C300OSY
C300BFG
Ames product specifications in U.S. customary units and metric are ap prox i mate and are provided for reference only. For pre cise mea sure ments, please contact Ames Technical
Service. Ames reserves the right to change or mod i fy product design, con struc tion, specifications, or ma te ri als without pri or notice and without incurring any obligation to make
such changes and mod i fi ca tions on Ames products pre vi ous ly or sub se quent ly sold.
TheColtC300,C300NDoubleCheckDetectorAssembliesareusedto
preventbackflowofpollutants,thatareobjectionablebutnottoxic,from
enteringthepotablewatersupplysystem.TheColtC300,C300Nmay
beinstalledundercontinuouspressureserviceandmaybesubjected
tobackpressure.TheColtC300,C300Nisusedprimarilyonfireline
sprinklersystemswhenitisnecessarytomonitorunauthorizeduseof
water.Foruseinnon-healthhazardapplications.
Specifications
TheColtC300,C300NDoubleCheckDetectorAssembliesshallconsist
oftwoindependentTri-LinkCheckmoduleswithinasinglehousing,
sleeveaccessport,fourtestcocksandtwodriptightshutoffvalves.
Tri-LinkChecksshallberemovableandserviceable,withouttheuseof
specialtools.Thehousingshallbeconstructedof304(Schedule40)
stainlesssteelpipewithgrooveendconnections.Tri-LinkChecksshall
havereversibleelastomerdiscsandinoperationshallproducedriptight
closureagainstthereverseflowofliquidcausedbybackpressureor
backsiphonage.Thebypassassemblyshallconsistofameter,which
registersineithergallonorcubicmeasurement,adoublecheckvalve
assemblyandrequiredtestcocks.AssemblyshallbeaColtC300,C300N
asmanufacturedbytheAmesCompany.
Colt
TM
Series C300, C300N
Double Check Detector Assemblies
Sizes:2
1
2"–10"(65–250mm)
www.amesfirewater.com
Dimensions Weights
Configurations
• Horizontal
• Verticalup
• “N”patternhorizontal
Materials
• Housing&Sleeve:304(Schedule40)StainlessSteel
• Elastomers:EPDM,SiliconeandBuna‘N’
• Tri-LinkChecks:Noryl
®
,StainlessSteel
• CheckDiscs:ReversibleSiliconeorEPDM
• TestCocks:BronzeBodyNickelPlated
• Pins&Fasteners:300SeriesStainlessSteel
• Springs:StainlessSteel
Available Models
Suffix:
OSY-UL/FMoutsidestemandyokeresilient
seatedgatevalves
BFG-UL/FMgroovedgearoperatedbutterflyvalves
withtamperswitch
*OSYFxG-Flangedinletgateconnectionandgrooved
outletgateconnection
*OSYGxF-Groovedinletgateconnectionandflanged
outletgateconnection
*OSYGxG-Groovedinletgateconnectionandgrooved
outletgateconnection
AvailablewithgroovedNRSgatevalves-consultfactory*
Postindicatorplateandoperatingnutavailable-consultfactory*
*Consultfactoryfordimensions
Pressure Temperature
TemperatureRange:33°F–140°F(5°C–60°C)
MaximumWorkingPressure:175psi(12.06bar)
H
A
I
J
G
P
C
D
A
D
C (open)
G
H
J
I
P
C300, C300N
C300BFG, C300NBFG
SIZE (DN) DIMENSIONS WEIGHT
A C (OSY) D G H I J P C300 C300N
in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs.
2
1
2 65 31 787 16
3
8 416 3
1
2 89 29
1
16 738 22 559 15
1
2 393 8
13
16 223 13
3
16 335 139 63 147 67
3 80 31
11
16 805 18
7
8 479 3
11
16 94 30
1
4 768 22
3
4 578 17
1
8 435 9
3
16 233 14
1
2 368 159 72 172 78
4 100 33
11
16 856 22
3
4 578 4 102 33 838 24 610 18
1
2 470 9
15
16 252 15
3
16 386 175 79 198 90
6 150 43
1
2 1105 30
1
8 765 5
1
2 140 44
3
4 1137 33
3
4 857 23
3
16 589 13
1
16 332 19 483
309 140 350 159
8 200 50 1270 37
3
4 959 6
11
16 170 54
1
8 1375 40
5
8 1032 27
7
16 697 15
11
16 399 21
3
16 538
494 224 569 258
10 250 57
1
2 1460 45
3
4 1162 8
3
16 208 66 1676 50 1270 32
1
2 826 17
5
16 440 24 610
795 361 965 438
SIZE (DN) DIMENSIONS WEIGHT
A C D G
H I J P C300BFG C300NBFG
in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs.
2
1
2 65 28 711 8 203 3
1
2 89 29
7
8 759 22 559 14
15
16 379 8
13
16 223 13 330
70 32 78 35
3 80 28
1
2 724 8
5
16 211 3
11
16 94 30
11
16 779 22
3
4 578 15
7
16 392 9
3
16 233 13
1
2 343
68 31 81 37
4 100 29
3
16 741 8
15
16 227 3
11
16 94 31
15
16 811 24 610 16
1
4 412 9
15
16 252 14 356
75 34 98 44
6 150 36
1
2 927 10 254 5 127 43
3
16 1097 33
3
4 857 19
11
16 500 13
1
16 332 14
1
2 368
131 59 171 78
8 200 43 1092 12
1
4 311 6
1
2 165 51
1
16 1297 40
5
8 1032 23
5
16 592 15
11
16 399 18
3
16 462
275 125 351 159
Noryl
®
is a registered trademark of General Electric Company.
Approvals
For additional approval information please contact the factory or visit our website at www.amesfirewater.com
Capacity
UL/FM Certified Flow Characteristics
Flow characteristics collected using butterfly shutoff valves.
See literatue S-Colt-200/300 for gate valve flow characteristics
*=RatedFlow**=ULTested
Horizontal Vertical N - Pattern
IMPORTANT: INQUIRE WITH GOVERNING AUTHORITIES
FOR LOCAL IN STAL LA TION RE QUIRE MENTS
kPa psi
96 14
83 12
69 10
55 8
41 6
28 4
14 2
0 0
0 50 100 150 200 250 300 350 gpm
0 190 380 570 760 950 1140 1330 lpm
15 fps
4.6 mps
kPa psi
83 12
69 10
55 8
41 6
28 4
14 2
0 0
0 100 200 300 400 500 gpm
0 380 760 1140 1520 1900 lpm
15 fps
4.6 mps
2
1
2" (65mm)
3" (80mm)
*
kPa psi
83 12
69 10
55 8
41 6
28 4
14 2
0 0
0 300 600 900 1200 1500 gpm
0 1140 2280 3420 4560 5700 lpm
15 fps
4.6 mps
6" (150mm)
kPa psi
83 12
69 10
55 8
41 6
28 4
14 2
0 0
0 500 1000 1500 2000 2500 gpm
0 1900 3800 5700 7600 9500 lpm
15 fps
4.6 mps
8" (200mm)
kPa psi
165 24
138 20
110 16
83 12
55 8
28 4
0 0
0 100 200 300 400 500 600 700 800 gpm
0 380 760 1140 1520 1900 2280 2660 3040 lpm
15 fps
4.6 mps
4" (100mm)
kPa psi
83 12
69 10
55 8
41 6
28 4
14 2
0 0
0 500 1000 1500 2000 2500 3000 3500 gpm
0 1900 3800 5700 7600 9500
11400 13300
lpm
fps
mps
10" (250mm)
*
*
*
*
*
N
V
H
N
V
H
N
V
H
N
V
H
N
V
H
N
V
H
**
**
**
**
**
**
B64.41048
For additional information, visit our web site at: www.amesfirewater.com
ES-A-C300/C300N1006 ©2010AmesFire&Waterworks
www.amesfirewater.com
A Watts Water Technologies Company USA: Backflow- 1427 N. Market Blvd • Suite #9 • Sacramento, CA 95834 T: 916-928-0123 F: 916-928-9333
Control Valves- 18550 Hansen Road • Houston, TX 77075 • T: 713-943-0688 F: 713-944-9445
Canada: 5435 North Service Rd. Burlington, ONT. L7L 5H7• T: 905-332-4090 • F: 905-332-7068
/