Paxton BC-16 User manual

Type
User manual
ENGLISH
1
BC-16 Reader
Installation Note
81733-2
06-20
EN
General
The BC-16 is a Magnetic Stripe Card-only Reader for use with Bewator Entro and Entro Lite Door Controllers.
The BC-16 can be mounted externally or internally, if mounted externally the use of the SH-2 Rain Hood
is advised. All other information regarding installation and programming can be found in the manual
supplied with the relevant Door Controller.
The BC-16 is supplied complete with 5 meters of cable. When extending this cable, always use a
screened multicore cable i.e. BELDEN 9540 10 core screen. If only one Reader is required at the door,
then the BC-16 can be connected directly to the Door Controller. In this configuration the Reader can be
connected up to a maximum of 50 meters from the Door Controller.
If two Readers are required at the door or distances of up to 100 meters from the Reader to the Door
Controller are needed, then a Bewator Multibox must be used.
Wiring Notes.
The screen(s) from the BC-16 should be terminated in the controller housing to mains earth (Earth Node).
When installing the cable(s) from the BC-16 care should be taken to avoid location near sources of
electrical noise such as motors, generators, pumps, mains cabling and computer installations.
6
BC-16
Door Controller
6
Door Controller
BC-16
BC-16
6
6
50 metre
100 metre
Multibox
Mounting the reader BC-16
Install the BC-16 at a height of approximately 40 – 50cm (from the floor to the bottom edge of the
Reader). To adapt the installation to suite disabled access, a suitable height is approximately 100cm.
Use the template supplied to fix the screws into the wall and drill the cable hole.
Insert the screws until the heads are clear of the wall by the thickness of the back plate
Hook the BC-16 on to the screws and lock in position using the screw on the bottom of the unit
If the BC-16 is mounted on an earthed surface, do not connect the cable screen.
If the wall is uneven, a mounting plate is available as an optional extra.
1.
2.
3.
4.
5.
ENGLISH
2
Connecting the BC-16 to DC-12 and DC-22 Entro Door Controllers - or the DC800 Entro Lite
Door Controller
Note! For Entro: connect to the Clock & Data terminal block. Set the link J4 in the door controller to +V
= Vin, but NEVER exceed 12V as power supply. A Higher voltage will damage the reader beyond
repair.
For Entro Lite set jumper J1 in the DC800 to Vin and set jumper J4 to Clock & Data, but NEVER
exceed 12V as power supply. A Higher voltage will damage the BC-16 beyond repair.
Power to the BC-16 will be supplied from the Door Controller.
Red
Black
Green
Blue
Yellow
Screen to Earth Node
DC-22
DC-12DC800
(+ 12Volt)
(0 Volt)
(Green LED)
(Data)
BC-16
(Clock)
15
16
18
19
20
14
15
17
18
19
5
Connecting the BC-16 to DC-12 and DC-22 Entro Door Controllers - or the DC800 Entro Lite
Door Controller
For a two-reader operation, a Bewator Multibox, must be used.
Note! For Entro: connect to the Clock & Data terminal block. Set the link J4 in the door controller to +V
= Vin, but NEVER exceed 12V as power supply. A Higher voltage will damage the reader beyond
repair.
For Entro Lite set jumper J1 in the DC800 to Vin and set jumper J4 to Clock & Data, but NEVER
exceed 12V as power supply. A Higher voltage will damage the BC-16 beyond repair.
Power to the BC-16 will be supplied from the Door Controller.
Screen to Earth Node
Screen to Earth Node
Yellow
Black
Red Violet
Blue
Green
Yellow
BlackBlue
RedViolet
Green
1
2
3
4
5
6
7
8
9
10
19
15
18
16
20
Clock
+V
Green
0V
Data
10 9 8 7 6 5 4 3 2 1
1 2 3 4 5 6 7 8 9 10
6
5
4
3
2
1
PL1
PL4
PL2
PL3
BC-16
DC-22
DC-12
18
14
17
15
19
DC800
Multibox
BC-16
5
Technical specifications
Power supply: 12 Vdc. Temperature range: -20 to +55 °C.
Power consumption: 70 mA min, 300mA max. Dimensions HxWxD mm: 89 x 34 x 34.
Weight (packed): 300g.
  • Page 1 1