1.2. Maine technical characterictics
1. Frequency range…………………………….…………………………..….100 – 5 600 Hz
2. Number of channels / noise generators:
- SEL SP-55/2……………………………………….…….…..…….………….2 / 2
- SEL SP-55/4…………………………………….……….…..…….………….4 / 4
3. Maximum integrated output power for one channel (with 4 Ohm)………………..2.5 W
4. Range of regulation of the level in octave strips
250/500/1000/2000/4000 Hz for one channel, not less than…….…10/12/13/15/20 dB
5. Characteristics stability:
- at power supply voltage deviations 220V (+10% -15%), not worse than ±5%
- at 8 hours continuous work, not worse than..………………………….......±3%
6. Number of electromagnetic vibro-transducers for one channel..….…..…….1 – 12 pcs
7. Basic characteristics of the generator:
- power supply:
- from the power net.………….………220 V (± 10%) / 50÷60 Hz
- from reserved power supply unit.………….……………12Vx2A
- dimensions.………………………………………………..……180x180x45 mm
- weight, not more than.……………………………………...……………..1500 g
- terms of usage:
- temperature.………………………………………...+25 (± 10) °С
- relative air humidity, not more than.………………80% at 25 °С
- atmospheric pressure.………………………..740 (± 40) mm Hg
8. Basic characteristics of the vibro-transducers:
- type….……………………………………………………………electromagnetic
- resistance..………………………………………………………………….8 Ohm
- power supply.……………………………………………………..from generator
- dimensions:
- SEL SP-51/V..……………………………………..…∅51x22 mm
- SEL SP-51/VG..…………………………….……..…∅43x17 mm
- weight, not more:
- SEL SP-51/V..……………………………………………..…150 g
- SEL SP-51/VG..…………………………………….……..…100 g
- terms of usage:
- temperature range..………………….…..……………-40 +60 °С
- relative humidity (the case is sealed)...…………….up to 100%
- atmospheric pressure.……………….……..…..750 ±40 mm Hg
Appendix No.1
Recommendations to installing SEL SP - 55 systems
I. Placing electromagnetic vibro-transducers and acoustic radia-
tors
Recommendations:
• Vibro-transducers SEL SP – 55/V should be installed:
- in regular intervals - in chessboard order, not more than 3 m from
each other and not closer than 1 m from corners of sides of protected
volumes, connection of the next radiators to different channels is de-
sirable;
- for the best protected effect use minimum two vibro-transducers on
each any size protected surface.
• Vibro-transducers SEL SP – 55/VG should be installed at each window corner
on removal ~ 5 ÷ 10 cm from it.
• Acoustic radiators should be installed in protected areas (air lines, ventilating
mines, behind false ceilings, etc.).
II. Installing electromagnetic vibro-transducers and acoustic ra-
diators
2.1. Installing SEL SP – 55/V vibro-transducers
There are three types of mounting elements: a pin, a plate and a holder
for mounting on heating pipes:
To install pins it is necessary to drill a hole in a protected construction, fill it
with a solidificated caulk and densely hammer in a pin.
To install plates is necessary to drill holes in a protected construction for
adjusting screws, drift on waterproof glue, mount a plate and fix it “tightly” using
adjusting screws.