1
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
ADDENDUM
INSTALLATION INSTRUCTIONS FOR INSTALLING AFUE BAFFLE KITS
ON ASTRIATM ALTAIR AND SUPERIORTM DRT4040/4045 GAS FIREPLACES
ALTAIRTM AND DRT4040/4045 AFUE BAFFLE KITS
KIT CONTENTS
1 ea. AFUE Baffle
1 ea. AFUE Addendum
AFUE BAFFLE KITS
Cat. No. Description
611350-07 AFUE Baffle Kit, Altair and DRT4040/4045 - Rear Vent, Natural Gas
611350-08 AFUE Baffle Kit, Altair and DRT4040/4045 - Rear Vent, Propane Gas
TOOLS NEEDED
5/16" Nut Driver
GENERAL INFORMATION
If you encounter any problems, need clarification of these instructions or
are not qualified to properly install this kit, contact you local distributor
or dealer.
Read this addendum in its entirety before beginning the installation.
ALL WARNINGS, PRECAUTIONS AND INSTRUCTIONS IN THE INSTAL-
LATION AND CARE AND OPERATION MANUALS PROVIDED WITH THE
APPLIANCE APPLY TO THESE INSTRUCTIONS.
Figure 1 - Minimum Vent Configuration
A minimum vent configuration is defined by the example below with no
other vent component sections used than what is shown here.
WHEN ALTAIR AND DRT40/4045 FIREPLACES ARE INSTALLED
USING MINIMUM VENT COMPONENTS IN A REAR VENT CON-
FIGURATION (AS DEFINED IN FIGURE 1), AN AFUE BAFFLE MUST
BE INSTALLED PER THE INSTRUCTIONS IN THIS DOCUMENT.
One SV4.5RCH Slip
Adaptor only
SV4.5HT-2 Square
Termination
REAR VENT
Minimum Vent Configuration *
* Dimension from the base of the horizontal termination to the fireplace 1/2”
rear spacers is ~7" to 7-1/2” (assumes a 6” thick wall with interior and exterior
wall surface material). The AFUE baffle is not required if this dimension is over
7-1/2".
*Astria Models; Altair40DEN, Altair40DMN, Altair40DMP, Altair45DEN,
Altair45DMN, Altair45DMP
Superior Models; DRT4040DEN, DRT4040DMN, DRT4040DMP, DRT-
4045DEN, DRT4045DMN, DRT4045DMP
506020-16
REV. A 01/2015