- 14 -
000707AG
2 - Characteristics
A4 1:1 1/1
Regulatory Label of UNO- 3.3 PLUS-U BDM- TL R- - S-S - A
LABEL MATERIAL: 3M type 7331 (UL R/C PGJI2)
INKS: Refer to UL File MH16411
LABEL CONTENT: Fixed as shown in the picture
SIZE: 135 mm (height) x 75 mm (width)
XLP.V2P25.0AL AA
A.Statuti
R.White
G.Manchia
C.Granci
www.abb.com/solar
SOLAR GRID SUPPORT UTILITY INTERACTIVE
TRANSFORMERLESS INVERTER
MODEL: UNO 3.3 TL PLUS- SB-- - - US- ADM- R
UL 1741
CSA-C22.2 No. 107.1-01
Country of Origin Italy
For more details about product specifications refer to the Instruction Manual
DC Ground Fault Detector/Interrupter is Provided Photovoltaic Arc-Fault Circuit Protection-Type1
Operating Ambient Temperature: , with Output Power Derating-25 to +60 °C (-13 to +140 °F)
Type of Enclosure: NEMA 4X
(¹): (²):Adjustable from 50.0 Hz to 59.9 Hz Adjustable from 60.1 Hz to 64.0 Hz
@Smax(³): Adjustable from -0.8 to +0.8
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesidered operation.
Nominal Input Operating Voltage
DC RATING
Max. Input Voltage
Range of Input Operating Voltage
Range of Input Voltage @Full Power
Max. Input Current - per channel
Max. Input Short Circuit Current - per channel
600 V
90 - 580 V
160 - 530 V
10 A
12.5 A
Rated Grid AC Voltage (Vacr)
AC RATING
Operating Voltage Range
Nominal Output Frequency
Operating Frequency Range
Power Factor
Nameplate Apparent Power (Smax)
Rated Active Power (@Vacr, cos = ± 0.9)φ
cos Adjustability Rangeφ
Max. Output Current
Max. Output Overcurrent Protection
Nameplate Active Power (Pmax @cos = 1)φ
60 Hz (factory preset)
50.0 (¹) - 64.0 (²) Hz
>0.995 (³)
3300 VA
0.1 - 1 ( )
3
14.5 A (rms)
20 A
Contains FCC ID: X6W-V2P53
310 V
208 V~ 1Ø
183-228 V~
2700 W
240 V~ 1Ø
211-264 V~
3300 W @ 50 °C amb.
3000 W
340 V
170 - 530 V
26 4 7/0 /201
26 4 7/0 /201
26 4 7/0 /201
26 4 7/0 /201
All
material
used
and finished product, must meet the requirements of the current RoHS
recti
i
ve 2002/95/EC.
Title
Issued
Modified
D
D
esign approved
Elec. Eng. approved
Mfg. approved
Size Scale Dim. in mm Sheet Drawing No. Revision
© Copyright 2017 Power-One Italy Spa. All rights reserved. Reproduction, use or disclosure to third parties without express written authority is strictly forbidden.
1
4
2
3
A4 1:1 1/1
Regulatory Label of UNO- 3.8 PLUS-U BDM- TL R- - S-S - A
LABEL MATERIAL: 3M type 7331 (UL R/C PGJI2)
INKS: Refer to UL File MH16411
LABEL CONTENT: Fixed as shown in the picture
SIZE: 135 mm (height) x 75 mm (width)
XLP.V2P26.0AL AA
A.Statuti
R.White
G.Manchia
C.Granci
www.abb.com/solar
SOLAR GRID SUPPORT UTILITY INTERACTIVE
TRANSFORMERLESS INVERTER
MODEL: UNO 3.8 TL PLUS- SB-- - - US- ADM- R
UL 1741
CSA-C22.2 No. 107.1-01
Country of Origin Italy
For more details about product specifications refer to the Instruction Manual
DC Ground Fault Detector/Interrupter is Provided Photovoltaic Arc-Fault Circuit Protection-Type1
Operating Ambient Temperature: , with Output Power Derating-25 to +60 °C (-13 to +140 °F)
Type of Enclosure: NEMA 4X
(¹): (²):Adjustable from 50.0 Hz to 59.9 Hz Adjustable from 60.1 Hz to 64.0 Hz
@Smax(³): Adjustable from -0.8 to +0.8
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesidered operation.
Nominal Input Operating Voltage
DC RATING
Max. Input Voltage
Range of Input Operating Voltage
Range of Input Voltage @Full Power
Max. Input Current - per channel
Max. Input Short Circuit Current - per channel
600 V
90 - 580 V
120 - 530 V
16 A
25 A
Rated Grid AC Voltage (Vacr)
AC RATING
Operating Voltage Range
Nominal Output Frequency
Operating Frequency Range
Power Factor
Nameplate Apparent Power (Smax)
Rated Active Power (@Vacr, cos = ± 0.9)φ
cos Adjustability Rangeφ
Max. Output Current
Max. Output Overcurrent Protection
Nameplate Active Power (Pmax @cos = 1)φ
60 Hz (factory preset)
50.0 (¹) - 64.0 (²) Hz
>0.995 (³)
4200 VA
0.1 - 1 ( )
3
16 A (rms)
20 A
Contains FCC ID: X6W-V2P53
310 V
208 V~ 1Ø
183-228 V~
3000 W
240 V~ 1Ø
211-264 V~
4200 W @ 50 °C amb.
3450 W
340 V
140 - 530 V
26 4 7/0 /201
26 4 7/0 /201
26 4 7/0 /201
26 4 7/0 /201
All
material
used
and finished product, must meet the requirements of the current RoHS
recti
i
ve 2002/95/EC.
Title
Issued
Modified
D
D
esign approved
Elec. Eng. approved
Mfg. approved
Size Scale Dim. in mm Sheet Drawing No. Revision
© Copyright 2017 Power-One Italy Spa. All rights reserved. Reproduction, use or disclosure to third parties without express written authority is strictly forbidden.
1
4
2
3
A4 1:1 1/1
Regulatory Label of UNO- 4.6 PLUS-U BDM- TL R- - S-S - A
LABEL MATERIAL: 3M type 7331 (UL R/C PGJI2)
INKS: Refer to UL File MH16411
LABEL CONTENT: Fixed as shown in the picture
SIZE: 135 mm (height) x 75 mm (width)
XLP.V2P27.0AL AA
A.Statuti
R.White
G.Manchia
C.Granci
www.abb.com/solar
SOLAR GRID SUPPORT UTILITY INTERACTIVE
TRANSFORMERLESS INVERTER
MODEL: UNO 4.6 TL PLUS- SB-- - - US- ADM- R
UL 1741
CSA-C22.2 No. 107.1-01
Country of Origin Italy
For more details about product specifications refer to the Instruction Manual
DC Ground Fault Detector/Interrupter is Provided Photovoltaic Arc-Fault Circuit Protection-Type1
Operating Ambient Temperature: , with Output Power Derating-25 to +60 °C (-13 to +140 °F)
Type of Enclosure: NEMA 4X
(¹): (²):Adjustable from 50.0 Hz to 59.9 Hz Adjustable from 60.1 Hz to 64.0 Hz
@Smax 4200 W @ 45 °C amb.(³): Adjustable from -0.8 to +0.8 ( ):
4
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesidered operation.
Nominal Input Operating Voltage
DC RATING
Max. Input Voltage
Range of Input Operating Voltage
Range of Input Voltage @Full Power
Max. Input Current - per channel
Max. Input Short Circuit Current - per channel
600 V
90 - 580 V
140 - 530 V
16 A
25 A
Rated Grid AC Voltage (Vacr)
AC RATING
Operating Voltage Range
Nominal Output Frequency
Operating Frequency Range
Power Factor
Nameplate Apparent Power (Smax)
Rated Active Power (@Vacr, cos = ± 0.9)φ
cos Adjustability Rangeφ
Max. Output Current
Max. Output Overcurrent Protection
Nameplate Active Power (Pmax @cos = 1)φ
60 Hz (factory preset)
50.0 (¹) - 64.0 (²) Hz
>0.995 (³)
4600 VA
0.1 - 1 ( )
3
20 A (rms)
25 A
Contains FCC ID: X6W-V2P53
310 V
208 V~ 1Ø
183-228 V~
3780 W
240 V~ 1Ø
211-264 V~
4600 W @ 40 °C amb. ( )
4
4140 W
340 V
150 - 530 V
26 4 7/0 /201
26 4 7/0 /201
26 4 7/0 /201
26 4 7/0 /201
All
material
used
and finished product, must meet the requirements of the current RoHS
recti
i
ve 2002/95/EC.
Title
Issued
Modified
D
D
esign approved
Elec. Eng. approved
Mfg. approved
Size Scale Dim. in mm Sheet Drawing No. Revision
© Copyright 2017 Power-One Italy Spa. All rights reserved. Reproduction, use or disclosure to third parties without express written authority is strictly forbidden.
1
4
2
3
A4 1:1 1/1
Regulatory Label of UNO- 5.0 PLUS-U BDM- TL R- - S-S - A
LABEL MATERIAL: 3M type 7331 (UL R/C PGJI2)
INKS: Refer to UL File MH16411
LABEL CONTENT: Fixed as shown in the picture
SIZE: 135 mm (height) x 75 mm (width)
XLP.V2P28.0AL AA
A.Statuti
R.White
G.Manchia
C.Granci
www.abb.com/solar
SOLAR GRID SUPPORT UTILITY INTERACTIVE
TRANSFORMERLESS INVERTER
MODEL: UNO 5.0 TL PLUS- SB-- - - US- ADM- R
UL 1741
CSA-C22.2 No. 107.1-01
Country of Origin Italy
For more details about product specifications refer to the Instruction Manual
DC Ground Fault Detector/Interrupter is Provided Photovoltaic Arc-Fault Circuit Protection-Type1
Operating Ambient Temperature: , with Output Power Derating-25 to +60 °C (-13 to +140 °F)
Type of Enclosure: NEMA 4X
(¹): (²):Adjustable from 50.0 Hz to 59.9 Hz Adjustable from 60.1 Hz to 64.0 Hz
@Smax(³): Adjustable from -0.8 to +0.8
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesidered operation.
Nominal Input Operating Voltage
DC RATING
Max. Input Voltage
Range of Input Operating Voltage
Range of Input Voltage @Full Power
Max. Input Current - per channel
Max. Input Short Circuit Current - per channel
600 V
90 - 580 V
130 - 530 V
19 A
25 A
Rated Grid AC Voltage (Vacr)
AC RATING
Operating Voltage Range
Nominal Output Frequency
Operating Frequency Range
Power Factor
Nameplate Apparent Power (Smax)
Rated Active Power (@Vacr, cos = ± 0.9)φ
cos Adjustability Rangeφ
Max. Output Current
Max. Output Overcurrent Protection
Nameplate Active Power (Pmax @cos = 1)φ
60 Hz (factory preset)
50.0 (¹) - 64.0 (²) Hz
>0.995 (³)
5000 VA
0.1 - 1 ( )
3
22 A (rms)
30 A
Contains FCC ID: X6W-V2P53
26 4 7/0 /201
26 4 7/0 /201
26 4 7/0 /201
26 4 7/0 /201
310 V
208 V~ 1Ø
183-228 V~
4118 W
240 V~ 1Ø
211-264 V~
5000 W @ 45 °C amb.
4500 W
340 V
145 - 530 V
All
material
used
and finished product, must meet the requirements of the current RoHS
recti
i
ve 2002/95/EC.
Title
Issued
Modified
D
D
esign approved
Elec. Eng. approved
Mfg. approved
Size Scale Dim. in mm Sheet Drawing No. Revision
© Copyright 2017 Power-One Italy Spa. All rights reserved. Reproduction, use or disclosure to third parties without express written authority is strictly forbidden.
1
4
2
3