These trim plates are designed to be used with Walker electrical systems and are UL Listed and/or Classified. They are intended to be installed in conformance with local and/or the National Electrical Code to ensure proper grounding and minimize the risk of shock or fire hazards.

The trim plates come in a variety of configurations to accommodate different needs. The 430 series is a blank plate without any openings, while the 431 series has conduit openings and the 432 series has activation. All plates are designed to be flush with the top of the carpet floor.

Legrand Walker Infloor Systems Trim Plates - 430, 431, 432

These trim plates are designed to be used with Walker electrical systems and are UL Listed and/or Classified. They are intended to be installed in conformance with local and/or the National Electrical Code to ensure proper grounding and minimize the risk of shock or fire hazards.

The trim plates come in a variety of configurations to accommodate different needs. The 430 series is a blank plate without any openings, while the 431 series has conduit openings and the 432 series has activation. All plates are designed to be flush with the top of the carpet floor.

For Presets with Activation:
1. Remove activation and all unused wire or cable.
2. If previously installed activation has link straps already installed, they can
be used to attach trim plate. (Save new link straps for future activation).
3. Attach trim plate to preset link straps so that plate is flush with top of
carpet floor.
For Presets without Activation:
1. Carpet installer shall carefully cut a 4 1/2" x 5" [114mm x 127mm] (single), or
5" x 9" [127mm x 229mm] (dual) cut out centered over preset, using a suitable
template. Save carpet cutout for future abandoning.
2. See page two for concrete, mudcap and knockout removal.
3. Secure link straps to post on preset. Mount plate to straps with screws.
4. For plates with conduit openings: Install connectors making splice in preset
before attaching trim plate.
5. For plates with tabs for 505 fittings: Slide housing over tabs and assemble as shown in diagram.
NOTE: Base plate of 505 fitting not used.
Trim Plates
Cat. Nos. 430, 431 and 432 Series
INSTALLATION INSTRUCTIONS
Walker
®
electrical systems conform to and should
be properly grounded in compliance with require-
ments of the current National Electrical Code or
codes administered by local authorities.
All electrical products may represent a possible
shock or fire hazard if improperly installed or used.
Walker electrical products bear the mark as UL
Listed and/or Classified and should be installed in
conformance with current local and/or the National
Electrical Code.
Cat. No. 430AL075 and 430BR075 (with
Conduit Opening. Cat. Nos. 430AL and
430BR (Blank) Similar.
Cat. Nos. 432AL and 432BR
Cat. No. 431AL075 and 431BR075 (with conduit open-
ings). Cat. Nos. 431AL and 431BR (Blank) Similar.
Cat. Nos. 430S505 and 431D505 (Shown)
505 Series
Order Separately
Link Strap 97651
Link
Strap
97650A
Walker Systems, Inc.
1000 Innovation Drive, Williamstown, WV 26187
1 000 209 0800
© Copyright 2000 The Wiremold Company All Rights Reserved
®
Walkerduct Pro Series Presets:
1.Use a Walker insert finder (Cat. No. 480) or other electronic locator
to find center of preset. Cut and remove carpeting or tile over preset. (
Carpet may be saved for later abandoning.) Chip out concrete
exposing mudcap.
NOTE: If presets are more than 1/2" [12.1mm] below concrete, use of a hammer drill with 1/2" chisel
is recommended. Be careful not to damage preset!
2. Remove Mudcap: (See Figure 1).
A. Strike blade of screwdriver or 1/4" [6.4mm] cold chisel along
side of mudcap as shown. Top edge of mudcap will
deflect inward.
B. Pry out cap with screwdriver by positioning blade between
preset wall and deflected edge of mudcap or, use pliers
to grab edge of cap and lift out. Remove all debris
from preset.
C. Grout around opening if concrete does not break
away cleanly.
3. Remove Knockout: (See Figure 2).
A. Insert screwdriver blade into opening in base of preset.
Push screwdriver toward center of preset, breaking tabs.
Position screwdriver into opening on other side of knockout
and break tabs to release knockout.
B. Inserting a wire hook into arched opening at center of preset
will prevent knockout from falling into duct. Remove all
debris from raceway.
CAUTION: Some sharp edges may occur along knockout tabs.
These must be deburred.
4. Important! Tighten bonding screw in base of preset with
No. 3 Phillips screwdriver.
Figure 1
Strike downward
near edge
Figure 2
See 3A
  • Page 1 1
  • Page 2 2

Legrand Walker Infloor Systems Trim Plates - 430, 431, 432 Installation guide

Type
Installation guide

Legrand Walker Infloor Systems Trim Plates - 430, 431, 432

These trim plates are designed to be used with Walker electrical systems and are UL Listed and/or Classified. They are intended to be installed in conformance with local and/or the National Electrical Code to ensure proper grounding and minimize the risk of shock or fire hazards.

The trim plates come in a variety of configurations to accommodate different needs. The 430 series is a blank plate without any openings, while the 431 series has conduit openings and the 432 series has activation. All plates are designed to be flush with the top of the carpet floor.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI