SCAN DSA 1 Instructions for Installation and Use

Type
Instructions for Installation and Use

SCAN DSA 1 is a high-quality wood-burning stove that offers an efficient and environmentally friendly way to heat your home. It features a sleek design, easy-to-use controls, and a durable construction that ensures years of reliable operation. With a rated output of 10 kW, the SCAN DSA 1 can heat up to 1,000 square feet, making it ideal for medium to large-sized homes. It also boasts an impressive 74% efficiency rating, meaning that it converts most of the heat it generates into usable warmth.

SCAN DSA 1 is a high-quality wood-burning stove that offers an efficient and environmentally friendly way to heat your home. It features a sleek design, easy-to-use controls, and a durable construction that ensures years of reliable operation. With a rated output of 10 kW, the SCAN DSA 1 can heat up to 1,000 square feet, making it ideal for medium to large-sized homes. It also boasts an impressive 74% efficiency rating, meaning that it converts most of the heat it generates into usable warmth.

SCAN
DSA 1
This manual is accompanied by a
pamphlet with General Instructions
for Installation.
Edition 10.06 - GB
MONTERINGSVEJLEDNING
med brugs- og fyringsanvisning
Indhold:
G
ene
relle råd og anvisninger . . . . . . . . . .2-3
Reklamationsret
Type- og miljøgodkendelse
Udpakning
Tilbehør til din pejs
Montering af kakler og fedtsten
Kvalitetskontrol
Anmeldelsespligt
Skorstenstjek
Skorstensløsninger
Bærende underlag
Brændbar eller ikke brændbar væg
Gulvplade
Varmefordeling
Justerskrue
Typeskilt
Produktionsnr.
Servicepakke
M
onte
ringsvejledning. . . . . . . . . . . . . . . . .4-7
Tilslutning til eksisterende/muret skorsten
Tilslutning topafgang til stålskorsten
Forbrændingsluft udefra
Brugs- og fyringsanvisning . . . . . . . . . . . 8-10
Vedligeholdelse af pejseovnen
Håndtering af brændsel
Optænding og fyring
Fejlsøgning . . . . . . . . . . . . . . . . . . . . . . . . 11
SCAN 3
B
R
U
G
S
A
N
V
IS
N
I
NG
T
il
denne
Brugsanvis
ning
hør
er
også
e
n
genere
l
Monterin
gsve
jledni
n
g.
U
dgav
e
03.0
3
-
DK
M
O
N
T
E
R
I
NGSV
E
J
L
E
D
N
I
N
G
m
e
db
r
u
g
s
-
o
g
f
y
rin
g
s
a
n
v
is
n
i
n
g
In
d
h
ol
d
:
G
e
n
e
r
e
l
l
e
r
å
d
o
g
a
n
v
i
s
n
i
nge
r
.
.
.
.
.
.
.
.
.
.
2
-
3
R
e
k
l
a
m
a
t
i
o
n
s
r
e
t
T
yp
e
-
o
g
m
i
l
j
ø
g
o
d
k
e
n
d
e
l
s
e
U
d
p
a
k
n
i
n
g
T
i
l
b
e
h
ø
r
t
i
l
d
i
n
p
e
j
s
M
o
n
te
r
i
n
g
a
f
k
a
kl
e
r
o
g
f
e
d
t
s
t
e
n
K
v
a
l
i
t
e
t
s
k
o
n
t
r
o
l
A
n
m
e
l
d
e
l
s
e
s
p
l
i
g
t
S
k
o
r
s
t
e
n
s
t
j
e
k
S
ko
r
s
t
e
n
s
l
ø
s
n
in
g
e
r
B
æ
r
e
n
d
e
u
n
d
e
r
l
a
g
B
r
æ
n
d
b
a
r
e
l
l
e
r
i
k
k
e
b
r
æ
n
d
b
a
r
v
æ
g
G
u
l
v
p
l
a
d
e
V
a
r
m
e
f
o
r
d
e
l
i
n
g
S
e
l
v
l
u
k
k
e
n
d
e
l
å
g
e
J
u
s
t
e
r
s
k
r
u
e
T
y
p
e
s
k
i
l
t
P
r
o
d
u
k
t
i
o
n
s
n
r.
S
e
r
v
i
c
e
p
a
k
k
e
M
o
n
t
e
r
i
n
g
s
v
e
j
l
e
d
n
i
n
g
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4
-
7
T
i
l
s
l
u
t
n
i
n
g
t
i
l
e
k
s
i
s
t
e
r
e
n
d
e
/
m
u
r
e
t
s
k
o
r
s
t
e
n
T
i
l
s
l
u
t
n
i
n
g
t
o
p
a
f
g
a
ng
t
i
l
s
t
å
l
s
k
o
r
s
t
e
n
F
o
r
b
r
æ
n
d
i
n
g
s
l
u
f
t
u
d
e
f
r
a
B
r
u
g
s
-
o
g
f
y
r
i
n
g
s
a
n
v
i
s
n
i
n
g
.
.
.
.
.
.
.
.
.
.
.
8
-
10
V
e
d
l
i
g
e
h
o
l
d
e
l
s
e
a
f
p
e
j
s
e
o
v
n
e
n
H
å
n
d
t
e
r
i
n
g
a
f
b
r
æ
n
d
s
e
l
O
p
t
æ
n
d
i
n
g
o
g
f
y
r
i
n
g
F
e
j
l
s
ø
g
n
i
n
g.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
1
1
T
i
l
d
e
n
n
e
m
o
n
t
e
r
i
n
g
s
v
e
j
l
e
d
n
i
n
g
h
ø
r
e
r
o
g
s
å
e
n
s
e
p
a
r
a
t
b
r
u
g
s
a
n
v
i
s
n
i
n
g
f
o
r
d
e
n
e
n
k
e
l
t
ep
e
j
s
.
U
d
g
a
v
e
0
2
/
0
3
-
D
K
Til d
e
n
n
e
m
o
n
te
ri
n
g
s
v
e
jl
e
d
n
in
g h
ø
re
r
o
g
s
å
e
n
s
e
p
a
r
a
t
b
ru
g
s
a
n
v
i
s
n
in
g fo
r
d
e
n
e
n
k
e
l
te p
e
j
s
.
Udgave 02/03 - DK
INSTRUCTIONS FOR
INSTALLATION AND USE
Approved according to EN 13240 2003
Declaration of Conformity
Manufacturer:
Krog Iversen & Co. A/S
DK - 5492 Vissenbjerg
Product:
SCAN DSA 1
Description of product:
Room heater for closed operation
This product complies with the requirements
of the directive
CPD 89/106/EEC
Applied to harmonized standard EN 13240
Signature: _____________________________
Managing director Henning Krog Iversen
Congratulations on your
new SCAN stove/insert!
You have chosen a product from one of Europe's leading
manufacturers of wood-burning stoves. We are convinced
that your insert will be to your full satisfaction and give you
many hours of pleasure if you follow the advice and instruc-
tions of this manual.
Please read this manual as well as the General Instructions
for Installation before beginning the installation.
Service bag
1 hexagon spanner
1 distance piece (to be used when the door is opened for
cleaning, servicing or dismounting)
1 oven mitt
Firelighters for the first lighting
Opening of the door
At the delivery of the stove, the door is locked. You can open
it by pulling out and turning the locking button at the same
time. The lock should not be activated in daily use, as the
guiding axle may be scratched and unnecessarily worn.
When the door is completely open, you can lock it by activa-
ting the locking button in the right side.
Mounting
The mounting must be done in accordance with the
local rules in the country where the stove is installed.
Before the installation
We refer to the General Instructions for Installation deliv-
ered with the stove concerning security distances (see
also page 4 of this pamphlet), requirements of flooring, etc.
Connection to the chimney
The connecting piece (fig. 6.1) has an inner diameter of Ø
200 mm. We recommend the use of a connecting piece/
adaptor fitting into the inside of the stove's flue collar to
lead condensation and rain into the stove, instead of on
the top plate. The chimney should continue with the same
dimension as the connecting piece and have a length that
ensures a proper functioning of the stove. Read more about
the connection to the chimney in the General Instructions
for Installation and follow always the advice of the chimney
manufacturer.
Damper/regulation of the chimney
draught
The chimney draught is regulated by means of the damper
above the stove. If your stove is to be built-in, the operating
rod for the damper should be led out through the masonry.
Adjustment screws
The stove has two adjustment screws in the bottom that can
be used for levelling the stove.
Built-in insert
Support frame (accessory)
The support frame is delivered with the following:
2 fittings
4 screws 5.8 flanged head
3 shackles
6 locks for wire
3 wire strainers
3 x 3 m wire
The function of the support frame is to carry the casing
above the door, if you want to build up around the insert.
Mount the two fittings on the sides of the insert (fig. 7). Put
the support frame into the fitting (fig. 8) and support it with a
piece of wood or the like in the desired height (according to
the height of the bricks used) from the floor.
Mount the shackles, the wire strainers (fig. 9) and the wires
on the support frame and fasten the wire to the ceiling, so
that the support frame is horizontal (fig. 10). Please check
that the wire is 100% tight and that the ceiling is able to carry
the weight.
When the bricks reach the support frame, you can remove
the piece of wood and continue to build up above the door.
The support frame is not to be in direct contact with the
insert, as steel expands/shrinks when warmed up or cooled
down. The masonry might crack if the support frame has
been attached on the insert itself.
Mantle
The built-in stove has a steel-plate framing. You can build
up around the stove or you can cover it with another NON-
COMBUSTIBLE material. The covering can be mounted
directly on the outside of the upper part of the insert. The
mantle is never to be in direct contact with the stove! When
covering the lower part of the stove, you must allow space
for the air intake for the convection system. You can build up
the covering against a wall or follow the shape of the stove
so that it becomes "free-standing".
Airing of the mantle
The air intake must have an area of min. 805 cm
2
and the
air outlet of min. 1250 cm
2
.
The convection system of the stove
The air from the room is drawn into the convection system
through the four air intakes on the sides of the lower part
of the insert (fig. 5). The air is heated in the combustion
chamber and rises up and out of the air outlet holes at the
top (fig. 6.2).
Ventilator (accessory)
The stove can be delivered with a ventilator. The ventilator
is mounted under the combustion chamber. Remove the
firebricks and lift up the loose steel plate. The ventilator with
wires is mounted on a plate that is pushed down in two slots
against the back of the insert. The electrical installation must
be carried out by an authorized electrician.
Mount the steel plate and the firebricks again.
Air for the room
You can add extra air for the room through an airshaft in the
outer wall.
2
SCAN DSA 1
You should read this manual as well as the General Instructions for Installation before beginning the installation.
1
5
5
2
3
3
4
4
6
Combustion air
Push the handle (fig. 1, 7) to the right in order to open
and to the left in order to close. The air is used for the
combustion and regulates the efficiency of the stove.
Cleaning of the glass
If you need to clean the glass, the door can be opened
in the following way:
IMPORTANT! Close the door and lock it by turning the
locking button (see "Opening of the door") before
you begin.
In order to protect the ceramic gasket at the bottom of the
door, you should place the distance piece (fig. 3) under
the door in the left side. Put a 6 mm hexagon spanner
in the hole of the right side of the door (fig. 4) and turn
clockwise. Swing out the door, clean the glass and close
the door. Turn the screw counter-clockwise and remove
the dis- tance piece.
Ceramic smoke deflector
After the chimney has been swept, you have to remove the soot that
has fallen down onto the ceramic smoke deflector. Lift up the deflector
in one side and tilt it down in the other side so that the soot falls into
the combustion chamber. Attention! The smoke deflector is made of
Skamol, which is a delicate material that easily breaks, so take care
when handling it.
Fig. 1
Fig. 2
Fig. 3 Fig. 4
Fig. 5 Fig. 6
Fig. 7 Fig. 8
Fig. 9 Fig. 10
6:1
6:2
2
1
SCAN DSA 1
Accessories
For the built-in insert you can have the following acces-
sories:
For the free-standing model you can have the following
accessories:
• Support frame
Damper for the regulation of the chimney draught
• Ventilator
Front plate at the door (steel or soapstone)
Cover for the elbow
• Ventilator
Shaped floor plate (steel or glass)
Connection piece for fresh-air intake
7
7
DSA 1 free standing
DSA 1 built-in
Warranty conditions
All SCAN wood-burning stoves and inserts are made of
first-class material and are subject to a strict quality control
before they leave the factory. However, if an error should
occur, we back all SCAN wood-burning stoves and inserts
with an extensive, five-year limited warranty.
See also the General Instructions for Installation delive-
red with your insert for more details.
Distance to flammable materials (mm)
Production number
Write the production number of your
insert here so that you have it at hand
in case you need to contact us.
SCAN DSA 1
706 / 662
808
874
729
Min. distance to the ceiling: 250 mm
1825
1555
Data for calculation of the chimney (DIN 18891)
*) The data are based on the German test
results according to DIN 18891 with a Ø 180
flue outlet.
Stove
model
SCAN
Connecting
adaptor
mm
1
Density of
flue gas
flow
g/s
2
Flue gas
tempera-
ture
o
C
3
Minimum
draft
Pa
4
Density of
flue gas
flow
g/s
5
Flue gas
temperature
o
C
6
Minimum
draft
Pa
7
0.8
Minimum
draft
Pa
DSA 1
200 *) - - - 14 220 15 11
With closed doorsWith open doors
Columns 2 and 5 show the flue gas temperature in the connecting adaptor
Columns 3 and 6 show the lowest/minimum draft in Pa by rated value
Columns 7 shows the lowest/minimum draft in Pa by 0.8 x rated value
200
1200
1200
460
460
Floor
plate
Floor
plate
Radiation area
Radiation area
300
300
500
300
300
500
*) 1640
*) Height to the beginning of the flue pipe (top outlet)
Technical info
Emission (% CO at 13% O
2
): 0.11%
Efficiency: 74%
Rated output: 10 kW
Chimney temperature: 220
o
C
Flue outlet flow: 14 g/sec
Recommended low pressure in conn. piece: 15 Pa
Recommended fuel: Wood
Amount of fuel and consumption: 3,22 kg/h
Min./max. (information from the factory): 8-11 kW
Weight, built in: 225 kg
Weight, freestanding: 226 kg
Connection piece, int. diameter: 200 mm
Connection piece, ext. diameter: 204 mm
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

SCAN DSA 1 Instructions for Installation and Use

Type
Instructions for Installation and Use

SCAN DSA 1 is a high-quality wood-burning stove that offers an efficient and environmentally friendly way to heat your home. It features a sleek design, easy-to-use controls, and a durable construction that ensures years of reliable operation. With a rated output of 10 kW, the SCAN DSA 1 can heat up to 1,000 square feet, making it ideal for medium to large-sized homes. It also boasts an impressive 74% efficiency rating, meaning that it converts most of the heat it generates into usable warmth.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages