Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
09/17/2008 1:00:58 PM
Specifications and Dimensions subject to change without notice.
ADF020757
ACCESSORIES (Order Separately)
C a n d e l a
Angle Along II 45
o
Across
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
3485 3485 3485
3453 3457 3528
3288 3404 3581
3010 3325 3603
2642 3172 3588
2169 2973 3333
1629 2541 2357
1013 1456 1103
405 330 300
21 59 46
5 169 143
7 334 358
12 251 510
17 100 322
22 53 123
23 33 55
21 18 32
21 15 18
20 20 20
C o e f
f i c i e n t s o f U t i l i z a t i o n
Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0
1
2
3
4
5
6
7
8
9
10
Z o n a l L u m e n S u m m a r y
Zone Lumens %Lamp %Fixture
0-30
0-40
0-60
0-90
90-180
0-180
DI-296HO
Energy Saving Ballast
F96T12/CW/HO/WM
Lamps
8000 Lumens
Spacing criterion:
(II) 1.3 x mounting
height, ( ) 1.6 x
mounting height
Efficiency 83.4%
Test Report:
DI296HO.IES
LER = FI-54
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $4.44
2867 17.9 21.5
4896 30.6 36.7
9581 59.9 71.8
12505 78.2 93.7
844 5.3 6.3
13349 83.4 100.0
98 98 98 98 95 95 95 95 90 90 90 85 85 85 80 80 80 78
89 85 81 78 86 83 79 76 78 75 73 74 72 70 70 68 67 65
81 74 68 63 78 72 66 62 68 63 59 64 60 57 61 58 55 53
73 64 57 51 71 62 56 51 59 54 49 56 51 47 53 49 46 44
67 56 49 43 64 55 48 42 52 46 41 49 44 40 47 43 39 37
61 50 42 36 59 49 41 36 46 40 35 44 38 34 42 37 33 31
56 45 37 31 54 43 36 31 41 35 30 39 34 30 38 33 29 27
52 40 33 27 50 39 32 27 37 31 27 36 30 26 34 29 25 24
48 36 29 24 46 36 29 24 34 28 23 23 27 23 31 26 23 21
45 33 26 21 43 30 26 21 31 25 21 30 24 21 29 24 20 19
42 31 24 19 40 30 23 19 29 23 19 28 22 18 27 22 18 17
Tandem
Blank=4' Length
8T=8' Length
Series
DI=Apertured
Reflector
DCI=Closed Top
Reflector
SAMPLE NUMBER: DI-296T8HO-120V-EB81- U
Number
of Lamps
2 Lamps
(Not included)
Wattage (Length)
48HO=60W T12 (48") HO
48T8HO=44W T8 (48") HO
96HO=95/110W T12 (96") HO
96T8HO=86W T8 (96") HO
Voltage
(1)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal Voltage 120-277
(2)
Options
GL=Single Element Fuse
GM=Double Element Fuse
Emergency=EM Installed
NOTES:
(1)
Products also available in non-US voltages and frequencies for international
markets.
(2)
Not available when specifying emergencies, voltage must be specific.
Specifications & dimensions subject to change without notice. Consult your Cooper
Lighting Representative for availability and ordering information.
Ballast Type
(1)
EB8 =T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
EB8
/PLUS=T8 Electronic Instant Start.
High Ballast Factor >1.13. Total
Harmonic Distortion < 20%
ER8
=T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
EB2
=T12 Electronic Rapid Start.
No. of Ballast
1, 2 or 3
No. of
Ballast
1, 2 or 3
No. of Ballast
1, 2 or 3
No. of Ballast
1 or 2
Options
RIF1=Radio Interference
Suppressor
6-3/18 SJT-C&P-515P=Cord
& Plug (120V)
6-3/18 SJT-C&P-
L715P=Cord & Plug (277V)
PI/CPI=Plug-In Option
TILW=Tandem In-Line
Wiring Option (Consult
TILW Option Catalog Page)
POX=Porlux Finish
(See options & accessories)
Packaging
U=Unit Pack
4B=4 Bulk
A1B/Spacer -U=Spacer 1-1/2" to 2-1/2" from ceiling
(Use 2 per fixture)
ATG-4=Tong Hanger (Use 2 per fixture)
SCF=Fixed Stem Set (Specify Length)
SCS=Swivel Stem Set (Specify Length)
SCA=Adjustable 48" Stem Set
AYC-Chain/Set-U =Chain Hanger Set (Use 1 set per fixture)
WG/DI-4FT-U
2
=Wire Guard
WGG/DI-4FT-U
2
=Wire Gym Guard
MECL-DI/SL-48-U =Metal Egg Crate Louver
MECL-DI/SL-96-U =Metal Egg Crate Louver
DI2=Long Connector
CEP=Closed End Plate
(Additional Accessories Available. See Options and Accessories Section).
DI-248HO
1
19 lbs.
DI-296T8HO 33 lbs.
Catalog No. Wt.