Sanyo SAP-CMRV1426EH-F, SAP-CMRV1926EH User manual

  • Hello! I am an AI chatbot trained to assist you with the Sanyo SAP-CMRV1426EH-F User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
TECHNICAL & SERVICE MANUAL
OUTDOOR UNIT : SAP-CMRV1426EH
SAP-CMRV1926EH
SAP-CMRV1936EH
SAP-CMRV2446EH
SAP-CMRV3146EH
SAP-CMRV1426EH
SAP-CMRV3146EH
SAP-CMRV1926EH
SAP-CMRV1936EH
SAP-CMRV2446EH
DC INVERTER MULTI-SYSTEM AIR CONDITIONER
Outdoor Model No.
SAP-CMRV1426EH-F
SAP-CMRV1926EH-F
SAP-CMRV1936EH-F
SAP-CMRV2446EH-F
SAP-CMRV3146EH-F
Capacity
4.0kW
5.6kW
5.6kW
6.8kW
8.0kW
Product Code No.
1 852 355 43
1 852 355 44
1 852 355 45
1 852 355 46
1 852 355 47
REFERENCE NO. SM700846
< Applicable Indoor Units >
For details about the combination, refer to "Unit
Combination Table" in the Appendix of this manual.
NOTE
Wall mounted type
SAP-KRV96EHDSA
SAP-KRV126EHDS
SAP-KMRV76EH
SAP-KMRV96EH
SAP-KMRV126EH
SAP-KRV186EH
SAP-KRV246EH
Destination: Europe
RoHS
WARNING
This product does not contain any hazardous substances prohibited by the RoHS Directive.
• You are requested to use RoHS compliant parts for maintenance or repair.
• You are requested to use lead-free solder.
FILE NO.
Do not vent R410A into atmosphere : R410A is a fluorinated greenhouse gas,
covered by Kyoto Protocol, with a Global Warming Potential (GWP) = 1975.
F-GAS REGULATION (EC) No 842 / 2006
When Wiring
ELECTRICAL SHOCK CAN CAUSE
SEVERE PERSONAL INJURY OR DEATH.
ONLY A QUALIFIED, EXPERIENCED
ELECTRICIAN SHOULD ATTEMPT TO
WIRE THIS SYSTEM.
SPECIAL PRECAUTIONS
This symbol refers to a hazard
or unsafe practice which can
result in severe personal
injury or death.
This symbol refers to a hazard
or unsafe practice which can
result in personal injury or
product or property damage.
CAUTION
CAUTION
WARNING
WARNING
Important!
Please Read Before Starting
This air conditioning system meets strict safety and
operating standards. As the installer or service person, it
is an important part of your job to install or service the
system so it operates safely and efficiently.
For safe installation and trouble-free operation, you
must:
Carefully read this instruction booklet before beginning.
Follow each installation or repair step exactly as shown.
Observe all local, state, and national electrical codes.
Pay close attention to all warning and caution notices
given in this manual.
If Necessary, Get Help
These instructions are all you need for most installation
sites and maintenance conditions. If you require help for
a special problem, contact our sales/service outlet or
your certified dealer for additional instructions.
In Case of Improper Installation
The manufacturer shall in no way be responsible for
improper installation or maintenance service, including
failure to follow the instructions in this document.
Do not supply power to the unit until all wiring and
tubing are completed or reconnected and checked.
Highly dangerous electrical voltages are used in this
system. Carefully refer to the wiring diagram and these
instructions when wiring. Improper connections and
inadequate grounding can cause accidental injury or
death.
Ground the unit following local electrical codes.
Connect all wiring tightly. Loose wiring may cause
overheating at connection points and a possible fire
hazard.
Install a protective leakage breaker depending on the
installation location (especially a damp or humid
location). If a leakage breaker is not installed, electric
shock can occur.
When Transporting
Be careful when picking up and moving the indoor and
outdoor units. Get a partner to help, and bend your knees
when lifting to reduce strain on your back. Sharp edges or
thin aluminum fins on the air conditioner can cut your
fingers.
When Installing
In a Ceiling or Wall
Make sure the ceiling/wall is strong enough to hold the
unit’s weight. It may be necessary to construct a strong
wood or metal frame to provide added support.
In a Room
Properly insulate any tubing run inside a room to prevent
"sweating" that can cause dripping and water damage to
walls and floors.
In Moist or Uneven Locations
Use a raised concrete pad or concrete blocks to provide a
solid, level foundation for the outdoor unit. This prevents
water damage and abnormal vibration.
In an Area with High Winds
Securely anchor the outdoor unit down with bolts and a
metal frame. Provide a suitable air baffle.
In a Snowy Area (for Heat Pump-type Systems)
Install the outdoor unit on a raised platform that is higher
than drifting snow. Provide snow vents.
When Connecting Refrigerant Tubing
Use the flare method for connecting tubing.
Apply refrigerant lubricant to the matching surfaces of
the flare and union tubes before connecting them, then
tighten the nut with a torque wrench for a leak-free
connection.
Check carefully for leaks before starting the test run.
When Servicing
Turn the power off at the main power box (mains) before
opening the unit to check or repair electrical parts and
wiring.
Keep your fingers and clothing away from any moving
parts.
Clean up the site after you finish, remembering to check
that no metal scraps or bits of wiring have been left
inside the unit being serviced.
Others
Ventilate any enclosed areas when installing or testing
the refrigeration system. Escaped refrigerant gas, on
contact with fire or heat, can produce dangerously toxic
gas.
Confirm upon completing installation that no refrigerant
gas is leaking. If escaped gas comes in contact with a
stove, gas water heater, electric room heater or other
heat source, it can produce dangerously toxic gas.
2
Table of Contents
APPLICABLE INDOOR UNITS
1. OPERATING RANGE
2. SPECIFICATIONS
2-1. Unit Specifications
2-2. Major Component Specifications
2-3. Other Component Specifications
3. DIMENSIONAL DATA
4. REFRIGERANT FLOW DIAGRAM
4-1. Refrigerant Flow Diagram
5. PERFORMANCE DATA
5-1. Temperature Charts
6. ELECTRICAL DATA
6-1. Electric Wiring Diagrams
7. FUNCTIONS
7-1. Explanation of Functions
7-2. Protective Functions
8. TROUBLESHOOTING
8-1. Precautions before Performing Inspection or Repair
8-2. Trouble Diagnosis by Error Monitor Lamps
8-3. Checking the Outdoor System
8-4. Trouble Diagnosis of Each Part
8-5. Trouble Diagnosis of Fan Motor
9. REFRIGERANT R410A:
SPECIAL PRECAUTIONS WHEN SERVICING UNIT
9-1. Characteristics of New Refrigerant R410A
9-2. Checklist before Servicing
9-3. Tools Specifically for R410A
9-4. Tubing Installation Procedures
9-5. In Case of Compressor Malfunction
9-6. In Case Refrigerant is Leaking
9-7. Charging Additional Refrigerant
9-8. Retro-Fitting Existing Systems
5
6
7
12
17
18
23
28
59
64
68
71
72
73
74
77
78
78
80
80
81
83
84
84
....................................................................................................
...................................................................................................................
.............................................................................................................
.......................................................................................
.......................................................................................
...................................................................................................................
...................................................................................................
............................................................................................................
....................................................................................................
....................................................................................................
...........................................................................................................
...........................................................
.........................................................................
............................................................................................
..........................................................................................
..........................................................................................
.........................................................................
...................................................................................................
................................................................................................
............................................................................................
....................................................................................
............................................................................................
..........................................................................................
............................................................................................
Page
3
APPENDIX A INSTALLATION INSTRUCTIONS
(SAP-CMRV1426EH)
APPENDIX B INSTALLATION INSTRUCTIONS
SAP-CMRV1926EH, SAP-CMRV1936EH
SAP-CMRV2446EH, SAP-CMRV3146EH
APPENDIX C UNIT COMBINATION TABLES
A-1
A-2
A-3
.............................................................................
.............................................................................
.................................................................................
Page
()
4
APPLICABLE INDOOR UNITS
SAP-CMRV1426EH
Multi-Outdoor Unit
Indoor Unit
YES YES YES NO NO
SAP-CMRV1926EH YES YES YES YES NO
SAP-CMRV1936EH YES YES YES YES NO
SAP-CMRV2446EH YES YES YES YES YES
SAP-CMRV3146EH
2-Room
2-Room
3-Room
4-Room
4-Room YES YES YES YES YES
SAP-
KMRV76EH
SAP-
KMRV96EH
SAP-
KMRV126EH
SAP-
KRV186EH
SAP-
KRV246EH
SAP-CMRV1426EH
Multi-Outdoor Unit
Indoor Unit
YES
SAP-CMRV1926EH YES
SAP-CMRV1936EH YES
2-Room
2-Room
3-Room
SAP-
KRV96EHDSA
YES
YES
YES
SAP-CMRV2446EH YES4-Room YES
SAP-CMRV3146EH YES4-Room YES
SAP-
KRV126EHDS
NOTE
1. The table lists the wall-mounted type of indoor units as representative models.
2. For details on the applicable indoor units other than the wall-mounted type, refer to the catalog.
5
1. OPERATING RANGE
Maximum
Minimum
Maximum
Minimum
32 °C D.B. / 23 °C W.B.
19 °C D.B. / 14 °C W.B.
27 °C D.B.
16 °C D.B.
43 °C D.B.
-
5 °C W.B.
24 °C D.B. / 18 °C W.B.
_
D.B. /
-
15 °C W.B.
(*1)
Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp.
Cooling
Heating
(*1) 0 °C D.B. : When combined with SAP-KRV186EH or SAP-KRV246EH.
Outdoor Unit : SAP-CMRV1426EH, SAP-CMRV1926EH, SAP-CMRV1936EH
 SAP-CMRV2446EH, SAP-CMRV3146EH
Indoor Unit : SAP-KRV96EHDSA, SAP-KRV126EHDS
 SAP-KMRV76EH, SAP-KMRV96EH, SAP-KMRV126EH
 SAP-KRV186EH, SAP-KRV246EH
6
2. SPECIFICATIONS
2-1. Unit Specifications
Outdoor Unit SAP-CMRV1426EH
Indoor Unit SAP-KMRV96EH
× 2
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
1. The values shown in perfromance section and electrical rating section above are based on the following unit combination.
For other combination unit, please refer to the "Unit Combination Table" in this manual.
Indoor Unit: SAP-KMRV96EH 2units Outdoor Unit: SAP-CMRV1426EH 1unit
2. Rating conditions are: Cooling: Indoor air temp. 27°C D.B. / 19°C W.B.
Outdoor air temp. 35°C D.B. / 24°C W.B.
Heating: Indoor air temp. 20°C D.B.
Outdoor air temp. 7°C D.B. / 6°C W.B.
Operation Sound Hi dB-A
Refrigerant Control
( 2.2 to 5.5 )
( 7,500 to 18,800 )
4.1
925
4.1
925
4.0
13,600
4.5
15,400
( 2.0 to 5.0 )
( 6,800 to 17,100 )
Shipping Volume
Cooling Heating
1,900
Cooling Heating
Net
Shipping
Weight
Height
× Width × Depth
kg
kg
m
3
mm
230V
1,900
198 to 264
Dimensions & Weight (Outdoor Unit)
Refrigerant Tubing Connections
Unit Dimensions
Electrical Rating
Air Circulation (High)
WPower Input
V
A
Available Voltage Range
Running Amperes
Narrow tube
Wide tube
Refrigerant mm (in.)
Tube Diameter mm (in.)
42.0
45.0
0.22
569
× 790 × 285
6.35 (1/4")
× 2
9.52 (3/8")
× 2
mMax. allowable tubing length per unit
Flare Type
20
Electric Expansion Valve
Compressor
Refrigerant / Amount charged at shipment kg
DC Twin Rotary (Inverter)
R410A / 1.7
Controls
Fan Speeds
Microprocessor
Auto (Hi, Me, Lo)
Features (Outdoor Unit)
C.O.P.
Compressor Locked Rotor Amperes
W/W
kW
Performance
- 4.86
47 48
%Power Factor 98 98
A 10.0
Type
Voltage Rating
BTU/h
Capacity
m
3
/h
2-Room Multi Outdoor Unit
E.E.R. W/W 4.32 -
Number of Connectable Indoor Units 2
Number of Operatable Indoor Units 2
Max. Capacity of Operating Indoor Units kW 6.15
Power Source 220 to 240V Single-Phase 50Hz
Height
×
Width
×
Depth mm
Package Dimensions
645
×
920
×
385
7
Outdoor Unit SAP-CMRV1926EH
Indoor Unit SAP-KMRV96EH
× 1 + SAP-KRV186EH × 1
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
1. The values shown in perfromance section and electrical rating section above are based on the following unit combination.
For other combination unit, please refer to the "Unit Combination Table" in this manual.
Indoor Unit: SAP-KMRV96EH 1unit + SAP-KRV186EH 1unit Outdoor Unit: SAP-CMRV1926EH 1unit
2. Rating conditions are: Cooling: Indoor air temp. 27°C D.B. / 19°C W.B.
Outdoor air temp. 35°C D.B. / 24°C W.B.
Heating: Indoor air temp. 20°C D.B.
Outdoor air temp. 7°C D.B. / 6°C W.B.
Operation Sound Hi dB-A
Refrigerant Control
( 2.4 to 8.4 )
( 8,200 to 28,700 )
7.52
1,695
7.70
1,735
5.6
19,100
7.3
24,900
( 2.1 to 6.8 )
( 7,200 to 23,200 )
Shipping Volume
Cooling Heating
2,500
Cooling Heating
Net
Shipping
Weight
Height
× Width × Depth
kg
kg
m
3
mm
230V
2,500
198 to 264
Dimensions & Weight (Outdoor Unit)
Refrigerant Tubing Connections
Unit Dimensions
Electrical Rating
Air Circulation (High)
WPower Input
V
A
Available Voltage Range
Running Amperes
Narrow tube
Wide tube
Refrigerant mm (in.)
Tube Diameter mm (in.)
65.0
69.0
0.38
740
× 900 × 320
6.35 (1/4")
× 2
9.52 (3/8")
× 2
mMax. allowable tubing length per unit
Flare Type
25
Electric Expansion Valve
Compressor
Refrigerant / Amount charged at shipment kg
DC Twin Rotary (Inverter)
R410A / 2.8
Controls
Fan Speeds
Microprocessor
Auto (Hi, Me, Lo)
Features (Outdoor Unit)
C.O.P.
Compressor Locked Rotor Amperes
W/W
kW
Performance
- 4.21
46 47
%Power Factor 98 98
A 14.5
Type
Voltage Rating
BTU/h
Capacity
m
3
/h
2-Room Multi Outdoor Unit
E.E.R. W/W 3.30 -
Number of Connectable Indoor Units 2
Number of Operatable Indoor Units 2
Max. Capacity of Operating Indoor Units kW 8.65
Power Source 220 to 240V Single-Phase 50Hz
Height
×
Width
×
Depth mm
Package Dimensions
868
×
1,050
×
423
8
Outdoor Unit SAP-CMRV1936EH
Indoor Unit SAP-KMRV96EH
× 3
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
1. The values shown in perfromance section and electrical rating section above are based on the following unit combination.
For other combination unit, please refer to the "Unit Combination Table" in this manual.
Indoor Unit: SAP-KMRV96EH 3units Outdoor Unit: SAP-CMRV1936EH 1unit
2. Rating conditions are: Cooling: Indoor air temp. 27°C D.B. / 19°C W.B.
Outdoor air temp. 35°C D.B. / 24°C W.B.
Heating: Indoor air temp. 20°C D.B.
Outdoor air temp. 7°C D.B. / 6°C W.B.
Operation Sound Hi dB-A
Refrigerant Control
( 3.4 to 8.4 )
( 11,600 to 28,700 )
6.88
1,550
7.70
1,735
5.6
19,100
7.3
24,900
( 2.9 to 6.8 )
( 9,900 to 23,200 )
Shipping Volume
Cooling Heating
2,500
Cooling Heating
Net
Shipping
Weight
Height
× Width × Depth
kg
kg
m
3
mm
230V
2,500
198 to 264
Dimensions & Weight (Outdoor Unit)
Refrigerant Tubing Connections
Unit Dimensions
Electrical Rating
Air Circulation (High)
WPower Input
V
A
Available Voltage Range
Running Amperes
Narrow tube
Wide tube
Refrigerant mm (in.)
Tube Diameter mm (in.)
65.0
69.0
0.38
740
× 900 × 320
6.35 (1/4")
× 3
9.52 (3/8")
× 3
mMax. allowable tubing length per unit
Flare Type
25
Electric Expansion Valve
Compressor
Refrigerant / Amount charged at shipment kg
DC Twin Rotary (Inverter)
R410A / 2.8
Controls
Fan Speeds
Microprocessor
Auto (Hi, Me, Lo)
Features (Outdoor Unit)
C.O.P.
Compressor Locked Rotor Amperes
W/W
kW
Performance
- 4.21
46 47
%Power Factor 98 98
A 14.5
Type
Voltage Rating
BTU/h
Capacity
m
3
/h
3-Room Multi Outdoor Unit
E.E.R. W/W 3.61 -
Number of Connectable Indoor Units 3
Number of Operatable Indoor Units 3
Max. Capacity of Operating Indoor UnitskW 10.5
Power Source 220 to 240V Single-Phase 50Hz
Height × Width × Depth mm
Package Dimensions
868 × 1,050 × 423
9
SAP-CMRV2446EH
SAP-KMRV96EH
× 4
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
1. The values shown in perfromance section and electrical rating section above are based on the following unit combination.
For other combination unit, please refer to the "Unit Combination Table" in this manual.
Indoor Unit: SAP-KMRV96EH 4units Outdoor Unit: SAP-CMRV2446EH 1unit
2. Rating conditions are: Cooling: Indoor air temp. 27°C D.B. / 19°C W.B.
Outdoor air temp. 35°C D.B. / 24°C W.B.
Heating: Indoor air temp. 20°C D.B.
Outdoor air temp. 7°C D.B. / 6°C W.B.
Operation Sound Hi
Refrigerant Control
( 3.4 to 9.0 )
( 11,600 to 30,700 )
8.87
2,000
8.87
2,000
6.8
23,200
8.6
29,300
( 2.9 to 8.1 )
( 9,900 to 27,600 )
Shipping Volume
Cooling Heating
2,700
Cooling Heating
Net
Shipping
Weight
Height
× Width × Depth
kg
kg
m
3
mm
230V
2,700
198 to 264
Dimensions & Weight (Outdoor Unit)
Refrigerant Tubing Connections
Unit Dimensions
Electrical Rating
Air Circulation (High)
WPower Input
V
A
Available Voltage Range
Running Amperes
Narrow tube
Wide tube
Refrigerant mm (in.)
Tube Diameter mm (in.)
65.0
69.0
0.38
740
× 900 × 320
6.35 (1/4")
× 4
9.52 (3/8")
× 3 + 12.7 (1/2") × 1
m
Flare Type
25
Electric Expansion Valve
Compressor
Refrigerant / Amount charged at shipment kg
DC Twin Rotary (Inverter)
R410A / 2.8
Controls
Fan Speeds
Microprocessor
Auto (Hi, Me, Lo)
Features (Outdoor Unit)
C.O.P.
Compressor Locked Rotor Amperes
W/W
kW
Performance
- 4.30
47 49
%Power Factor 98 98
A 14.5
Type
Voltage Rating
BTU/h
Capacity
m
3
/h
4-Room Multi Outdoor Unit
E.E.R. W/W 3.40 -
Number of Connectable Indoor Units 4
Number of Operatable Indoor Units 4
Max. Capacity of Operating Indoor UnitskW 13.1
Power Source 220 to 240V Single-Phase 50Hz
Height × Width × Depth mm
Package Dimensions
868 × 1,050 × 423
dB-A
Max. allowable tubing length per unit
Outdoor Unit
Indoor Unit
10
SAP-CMRV3146EH
SAP-KMRV96EH
× 4
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
1. The values shown in perfromance section and electrical rating section above are based on the following unit combination.
For other combination unit, please refer to the "Unit Combination Table" in this manual.
Indoor Unit: SAP-KMRV96EH 4units Outdoor Unit: SAP-CMRV3146EH 1unit
2. Rating conditions are: Cooling: Indoor air temp. 27°C D.B. / 19°C W.B.
Outdoor air temp. 35°C D.B. / 24°C W.B.
Heating: Indoor air temp. 20°C D.B.
Outdoor air temp. 7°C D.B. / 6°C W.B.
Hi
Refrigerant Control
( 3.4 to 9.8 )
( 11,600 to 33,400 )
7.58
1,725
8.96
2,040
8.0
27,200
9.4
32,000
( 2.9 to 9.2 )
( 9,900 to 31,400 )
Shipping Volume
Cooling Heating
3,030
Cooling Heating
Net
Shipping
Weight
Height
× Width × Depth
kg
kg
m
3
mm
230V
3,030
198 to 264
Dimensions & Weight (Outdoor Unit)
Refrigerant Tubing Connections
Unit Dimensions
Electrical Rating
Air Circulation (High)
WPower Input
V
A
Available Voltage Range
Running Amperes
Narrow tube
Wide tube
Refrigerant mm (in.)
Tube Diameter mm (in.)
82.0
86.0
0.45
890
× 900 × 320
6.35 (1/4")
× 4
9.52 (3/8")
× 2 + 12.7 (1/2") × 2
m
Flare Type
30
Electric Expansion Valve
Compressor
Refrigerant / Amount charged at shipment kg
DC Twin Rotary (Inverter)
R410A / 3.8
Controls
Fan Speeds
Microprocessor
Auto (Hi, Me, Lo)
Features (Outdoor Unit)
C.O.P.
Compressor Locked Rotor Amperes
W/W
kW
Performance
- 4.61
48 50
%Power Factor 99 99
A 17.0
Type
Voltage Rating
BTU/h
Capacity
m
3
/h
4-Room Multi Outdoor Unit
E.E.R. W/W 4.64 -
Number of Connectable Indoor Units 4
Number of Operatable Indoor Units 4
Max. Capacity of Operating Indoor Units kW 14.7
Power Source 220 to 240V Single-Phase 50Hz
Height × Width × Depth mm
Package Dimensions
1,019 × 1,050 × 423
Operation Sound dB-A
Max. allowable tubing length per unit
Outdoor Unit
Indoor Unit
11
Control PCB
Control Circuit Fuse
Controls
Part No.
Microprocessor
250V 25A
CB-CMRV1426EH
1 ... D420
Propeller
DC Motor
DAJ12-55J71-CR ... 1
8
RED - WHT :
WHT - BLU :
BLU - RED :
77.5
77.5
77.5
50
750 / 750
Internal Controller
Yes
-
-
Aluminum Plate Fin / Copper Tube
2
1.3
0.452
Fan
Q'ty ... Dia.
Type
mm
Fan Motor
Nominal Output
Coil Resistance
Rough Measure RPM (Cool:Hi / Heat:Hi)
Type
Model ... Q'ty
No. of Poles
Safety Device
Type
Over- Current Protection
(Ambient Temp. 20 °C)
Run Capacitor Micro F
VAC
W
Ohm
Face Area
Coil
Rows
Fin Pitch
Heat Exchanger Coil
m
2
mm
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
2-2. Major Component Specifications
2-2-1. Outdoor Unit
Outdoor Unit SAP-CMRV1426EH
C-6RVN93H0M / 1,000W
DC Twin Rotary (Hermetic)
Compressor
Compressor Model / Nominal Output
Type
FV50S ... 350Compressor Oil ... Amount CC
R - S : 0.482Coil Resistance (Ambient Temp. 20 °C) Ohm
S - T : 0.482
T - R : 0.482
Safety Device
YesCT (Peak current cut-off control)
YesCompressor Discharge Temp. Control
Yes
Operation cut-off control in abnormal ambient Temp.
CS-7L115Overload Relay
Open : 115 °C, Close : 95 °C
Model
Operation Temp.
-Run Capacitor
-
Micro F
VAC
-Crankcase Heater
Acrylic baked-on enamel finishExternal Finish
12
Control PCB
Control Circuit Fuse
Controls
Part No.
Microprocessor
250V 25A
CB-CMRV1926EH
1 ... D460
Propeller
DC Motor
SIC-71FW-D490-1 ... 1
8
-
90
650 / 650
Internal Controller
Yes
-
-
Aluminum Plate Fin / Copper Tube
2
1.4
0.595
Fan
Q'ty ... Dia.
Type
mm
Fan Motor
Nominal Output
Coil Resistance
Rough Measure RPM (Cool:Hi / Heat:Hi)
Type
Model ... Q'ty
No. of Poles
Safety Device
Type
Over- Current Protection
Yes
Over- Heat Protection
(Ambient Temp. 20 °C)
Run Capacitor Micro F
VAC
W
Ohm
Face Area
Coil
Rows
Fin Pitch
Heat Exchanger Coil
m
2
mm
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Outdoor Unit SAP-CMRV1926EH
5KD240XAB21 / 1,700W
DC Twin Rotary (Hermetic)
Compressor
Compressor Model / Nominal Output
Type
FV50S ... 900Compressor Oil ... Amount CC
U - V : 0.720Coil Resistance (Ambient Temp. 20 °C) Ohm
V - W : 0.708
W - U : 0.726
Safety Device
YesCT (Peak current cut-off control)
YesCompressor Discharge Temp. Control
Yes
Operation cut-off control in abnormal ambient Temp.
CS-7LN115Overload Relay
Open : 115 °C, Close : 100 °C
Model
Operation Temp.
-Run Capacitor
-
Micro F
VAC
230V 25WCrankcase Heater
Acrylic baked-on enamel finishExternal Finish
13
Control PCB
Control Circuit Fuse
Controls
Part No.
Microprocessor
250V 25A
CB-CMRV1935EHFA
1 ... D460
Propeller
DC Motor
SIC-71FW-D490-1 ... 1
8
-
90
650 / 650
Internal Controller
Yes
-
-
Aluminum Plate Fin / Copper Tube
2
1.4
0.595
Fan
Q'ty ... Dia.
Type
mm
Fan Motor
Nominal Output
Coil Resistance
Rough Measure RPM (Cool:Hi / Heat:Hi)
Type
Model ... Q'ty
No. of Poles
Safety Device
Type
Over- Current Protection
Yes
Over- Heat Protection
(Ambient Temp. 20 °C)
Run Capacitor Micro F
VAC
W
Ohm
Face Area
Coil
Rows
Fin Pitch
Heat Exchanger Coil
m
2
mm
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Outdoor Unit SAP-CMRV1936EH
5KD240XAB21 / 1,700W
DC Twin Rotary (Hermetic)
Compressor
Compressor Model / Nominal Output
Type
FV50S ... 900Compressor Oil ... Amount CC
U - V : 0.720Coil Resistance (Ambient Temp. 20 °C) Ohm
V - W : 0.708
W - U : 0.726
Safety Device
YesCT (Peak current cut-off control)
YesCompressor Discharge Temp. Control
Yes
Operation cut-off control in abnormal ambient Temp.
CS-7LN115Overload Relay
Open : 115 °C, Close : 100 °C
Model
Operation Temp.
-Run Capacitor
-
Micro F
VAC
230V 25WCrankcase Heater
Acrylic baked-on enamel finishExternal Finish
14
Control PCB
Control Circuit Fuse
Controls
Part No.
Microprocessor
250V 25A
CB-CMRV2445EHFA
1 ... D460
DC Motor
SIC-71FW-D490-1 ... 1
8
-
90
700 / 700
Internal Controller
Yes
-
-
Aluminum Plate Fin / Copper Tube
2
1.4
0.595
Fan
Q'ty ... Dia.
Type
mm
Fan Motor
Nominal Output
Coil Resistance
Type
Model ... Q'ty
No. of Poles
Safety Device
Type
Over- Current Protection
Yes
Over- Heat Protection
(Ambient Temp. 20 °C)
Run Capacitor Micro F
VAC
W
Ohm
Face Area
Coil
Rows
Fin Pitch
Heat Exchanger Coil
m
2
mm
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Outdoor Unit SAP-CMRV2446EH
5KD240XAB21 / 1,700W
DC Twin Rotary (Hermetic)
Compressor
Compressor Model / Nominal Output
Type
FV50S ... 900Compressor Oil ... Amount CC
U - V : 0.720Coil Resistance (Ambient Temp. 20 °C) Ohm
V - W : 0.708
W - U : 0.726
Safety Device
Yes
YesCompressor Discharge Temp. Control
Yes
Operation cut-off control in abnormal ambient Temp.
CS-7LN115Overload Relay
Open : 115 °C, Close : 100 °C
Model
Operation Temp.
-Run Capacitor
-
Micro F
VAC
230V 25WCrankcase Heater
Acrylic baked-on enamel finishExternal Finish
Rough Measure RPM (Cool:Hi / Heat:Hi)
CT (Peak current cut-off control)
Propeller
15
Control PCB
Control Circuit Fuse
Controls
Part No.
Microprocessor
250V 25A
CB-CMRV3145EHFA
1 ... D460
DC Motor
SIC-71FW-D490-1 ... 1
8
-
90
750 / 750
Internal Controller
Yes
-
-
Aluminum Plate Fin / Copper Tube
2
1.4
0.723
Fan
Q'ty ... Dia.
Type
mm
Fan Motor
Nominal Output
Coil Resistance
Type
Model ... Q'ty
No. of Poles
Safety Device
Type
Over- Current Protection
Yes
Over- Heat Protection
(Ambient Temp. 20 °C)
Run Capacitor Micro F
VAC
W
Ohm
Face Area
Coil
Rows
Fin Pitch
Heat Exchanger Coil
m
2
mm
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Outdoor Unit SAP-CMRV3146EH
5JD420XAB22 / 3,000W
DC Twin Rotary (Hermetic)
Compressor
Compressor Model / Nominal Output
Type
FV50S ... 1,200Compressor Oil ... Amount CC
U - V : 0.435Coil Resistance (Ambient Temp. 20 °C) Ohm
V - W : 0.441
W - U : 0.452
Safety Device
Yes
YesCompressor Discharge Temp. Control
Yes
Operation cut-off control in abnormal ambient Temp.
CS-7LN115Overload Relay
Open : 115 °C, Close : 100 °C
Model
Operation Temp.
-Run Capacitor
-
Micro F
VAC
230V 25WCrankcase Heater
Acrylic baked-on enamel finishExternal Finish
Rough Measure RPM (Cool:Hi / Heat:Hi)
CT (Peak current cut-off control)
Propeller
16
2-3. Other Component Specifications
0
0102030405060708090
40
60
80
100
120
140
160
180
200
20
Resistance (k ohm)
Temperature (°C)
40
35
30
25
20
15
10
5
0
-
20
-
15
-
10
-
50 5101520
Temperature (°C)
Resistance (k ohm)
Outdoor air temp sensor
Outdoor heat exchanger sensor
AW / AN sensor
BW / BN sensor
CW / CN sensor
DW / DN sensor
TKS295B
TKS292B
TKS292B
TKS292B
TKS292B
TKS292B
Model No.
of sensor
Sensor Name
1
1
1/1
1/1
0
0
1
1
1/1
1/1
0
0
1
1
1/1
1/1
1/1
0
Quantity of Sensor
1
1
1/1
1/1
1/1
1/1
1
1
1/1
1/1
1/1
1/1
SAP-
CMRV1426EH
SAP-
CMRV1926EH
SAP-
CMRV1936EH
SAP-
CMRV2446EH
SAP-
CMRV3146EH
Sensor Name
Compressor temp sensor TKS293B
Model No.
of sensor
111
Quantity of Sensor
11
SAP-
CMRV1426EH
SAP-
CMRV1926EH
SAP-
CMRV1936EH
SAP-
CMRV2446EH
SAP-
CMRV3146EH
17
295
608 85
790 70
46
336
310
285
4-ID:23.6
ID:18
2-ID:12
569
15
70122
158 70
14246
Wide tube service valve
dia.9.52
(
3/8"
)
× 2
Narrow tube service valve
dia.6.35 (1/4")
× 2
Unit: mm
(852-0-0010-10700-0)
3. DIMENSIONAL DATA
Outdoor Unit SAP-CMRV1426EH
18
293
608 136
12
900 85
35
369
345
320
ID:18
5-ID:23.6
740
18
75113
150 72
11451
Wide tube service valve
dia.9.52
(
3/8"
)
× 2
Narrow tube service valve
dia.6.35 (1/4")
× 2
Outdoor Unit SAP-CMRV1926EH
Unit: mm
(852-0-0010-13400-0)
19
293
608 136
12
35
369
345
320
ID:18
5-ID:23.6
900 85
740
18
75 70113
150 72
70
11451
Wide tube service valve
dia.9.52
(
3/8"
)
× 3
Narrow tube service valve
dia.6.35 (1/4")
× 3
Outdoor Unit SAP-CMRV1936EH
Unit: mm
(852-0-0010-10900-0)
20
/