SAFETY INFORMATION
Read, understand, and follow all safety information contained in these instructions prior to
installation and use of the Aqua-Pure fi lters. Retain these instructions for future reference.
Intended use:
The AP800 Series Whole House Water Filters are intended for use in fi ltering potable water in homes and
have not been evaluated for other uses. These fi lters are typically installed at the point of entry, and should
be installed by qualifi ed professional installers according to these installation instructions.
Indicates a potentially hazardous situation, which, if not avoided, could
result in death or serious injury and/or property damage.
Indicates a potentially hazardous situation, which, if not avoided, may
result in property damage.
To reduce the risk associated with ingestion of contaminants:
• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfec-
tion before or after the system.
To reduce the risk associated with a hazardous voltage:
• Do not install near electric wiring or piping which may be in the path of a drilling tool when selecting
the position to mount the fi lter bracket.
• If the home electrical system requires use of the cold water system as an electrical safety ground,
a jumper must be used to ensure a suffi cient ground connection across the fi lter installation piping
— refer installation to qualifi ed personnel.
To reduce the risk associated with property damage due to water leakage:
• Read and follow Use Instructions before installation and use of this system.
• Installation and Use MUST comply with all state and local plumbing codes.
• Protect from freezing. Drain fi lter when temperatures drop below 40°F (4.4°C).
• Do not install if water pressure exceeds 125 psi (862 kPa). If your water pressure exceeds 125 psi,
you must install a pressure limiting valve. Contact a plumbing professional if you are uncertain how to
check your water pressure.
• Do not install where water hammer conditions may occur. If water hammer conditions exist you must
install a water hammer arrester. Contact a plumbing professional if you are uncertain how to check for
this condition.
• Install on COLD water lines only (40-100°F (4.4-37.8°C)).
• The disposable fi lter cartridge must be replaced every six months or at the specifi ed service cycle.
• Do not use a torch or other high temperature sources near fi lter or plastic fi ttings.
• Do not install in direct sunlight.
• Do not install near water pipes which will be in path of a drilling tool when selecting the position to
mount the bracket.
• Mount fi lter in such a position as to prevent it from being struck by other items used in the area of
installation (waste baskets, etc).
• On plastic fi ttings, never use pipe sealant or pipe dope. Use thread sealing tape only.
• Ensure all tubing and fi ttings are secure and free of leaks.
• SHUT OFF FUEL SUPPLY TO WATER HEATER after water is shut off.
• Failure to follow instructions may void warranty.
• Allow a minimum of 2” (5 cm) clear space under fi lter to facilitate cartridge change.
• Install with the inlet and outlet ports as labeled. Make sure not to reverse connections.
• Some local codes may require the use of a licensed plumber or certifi ed installer when disrupting a
potable water line.
• Before starting installation, shut off main water supply and drain pipes.