Sony SDZ-S100 User manual

Category
Blank data tapes
Type
User manual

This manual is also suitable for

SDZ-S100
SDZ-S130
© 2003 Sony Corporation
4-680-196-13 (2)
S-AIT
Tape Drive Unit
Operating Instructions Page 5 _________________________________
Important Safeguards Page 50 ________________________________
2
Owner’s Record
Your S-AIT Tape Drive Unit is assigned model number SDZ-S100 or SDZ-S130 for regulatory
compliance certifications. The number is indicated on the model number label on your drive along with
the rated voltage and current.
WARNING
To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
To avoid electrical shock, do not open the cabinet.
Refer servicing to qualified personnel only.
Caution
The mains plug on this equipment must be used to disconnect mains power.
Please ensure that the socket outlet is installed near the equipment and shall be easily accessible.
Notice
Use the power cord set approved by the appropriate testing organization for the specific countries where this unit is to be
used.
Achtung
Zur Trennung vom Netz ist der Netzstecker aus der Steckdose zu ziehen, welche sich in der Nähe des Gerätes befinden
muß und leicht zugänglich sein soll.
Hinweis
Die 3-adrige Geräteanschlußleitung muß Typ H05VV-F oder H05VVH2-F sein und nach DIN VDE 0625 geprüft sein.
Der Stecker und die Gerätesteckdose müssen nach DIN VDE 0620 bzw DIN VDE 0625 geprüft sein. Der
Leitungsquerschnitt kann 0,5mm
2
betragen wenn die Anschlußleitung eine Länge von 2m nicht überschreitet.
Anderenfalls muß der Leitungsquerschnitt mindestens 0,75mm
2
betragen.
Hinweis
Maschinenlärminformations-Verordnung - 3. GPSGV, der höchste Schalldruckpegel beträgt 70 dB(A) oder weniger
gemäss EN ISO 7779.
Ratings
Voltage
AC 100 V - 240 V
Current
0.7 A - 0.4 A
Frequency
50 / 60 Hz
Max. Ambient Temperature
35 degrees centigrade
The model and serial numbers are on a label on the bottom of the unit.
Record the serial number in the space provided below. These numbers provide specific information about your S-AIT
Tape Drive Unit and will be very helpful if you have to contact technical support.
Model No.
Serial No.
Safety Information
3
A certified power supply cord has to be used with this equipment.
The relevant national installation and/or equipment regulations shall be considered.
A certified power supply cord not lighter than ordinary polyvinyl chloride flexible cord according to IEC 60227
(designation H05VV-F 3G 0.75 mm
2
or H05VVH2-F2 3G 0.75 mm
2
) shall be used. Alternative a flexible cord be of
synthetic rubber according to IEC 60245 (designation H05RR-F 3G 0.75 mm
2
) shall be used.
Zum Netzanschluss dieses Gerätes ist eine geprüfte Leitung zu verwenden.
Es sind die zutreffenden nationalen Errichtungs- und/oder Gerätebestimmungen zu beachten.
Es ist eine geprüfte flexible PVC-ummantelte Leitung entsprechend IEC 60227 (H05VV-F 3G 0.75 mm
2
oder H05VVH2-
F 3G 0.75 mm
2
) zu verwenden. Andernfalls ist eine flexible Leitung aus synthetischem Gummi entsprechend IEC 60245
(Bauartkurzzeichen H05RR-F 3G 0.75 mm
2
) zu verwenden.
ATTENTION
According to the EU Directives related to product safety, EMC and R&TTE the manufacturer of this product is Sony
Corporation, 6-7-35 Kitashinagawa Shinagawa-ku Tokyo, 141-0001 Japan. The Authorised Representative is Sony
Deutschland GmbH, Hedelfinger Strasse 61,70327 Stuttgart, Germany. For any service or guarantee matters please refer
to the addresses given in separate service or guarantee documents.
AUFMERKSAMKEIT
Im Sinne der EU Richtlinien bezüglich Produktsicherheit, EMV und R&TTE ist Sony Corporation, 6-7-35 Kitashinagawa
Shinagawa-ku Tokyo, 141-0001 Japan der Hersteller dieses Produktes. Bevollmächtigter ist Sony Deutschland GmbH,
Hedelfinger Strasse 61,D-70327 Stuttgart. Für Service oder Garantieangelegenheiten wenden Sie sich bitte an die in
separaten Service oder Garantiedokumenten angegebenen Adressen.
European Union Restriction of Hazardous Substances Directive compliant.
Entspricht der Richtlinie der Europäischen Union zur Beschränkung der Verwendung gefährlicher
Stoffe.
Bei diesem Laufwerk handelt es sich um ein Laser-Produkt der Klasse 1.
INFORMATION
You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to
operate this equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation.
Laser Notice
(For Model No. SDZ-S130 only)
The equipment contains a tape drive using laser that complies with IEC 60825-1.
The equipment is classified as a CLASS 1 LASER PRODUCT.
Caution
The use of controls or adjustments or performance of procedures other than those specified herein may result in
hazardous radiation exposure.
Caution
Do not look at the end of optical connecor on the back of the tape drive with naked eyes or through optical equipment
while the power is supplied to this product. Otherwise, your eyes may be injured.
4
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experience radio/TV technician for help.
The shielded interface cable recommended in this manual must be used with this equipment in order to comply with the
limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules.
If you have any questions about this product, contact your dealer.
Für Kunden in Deutschland
Diese Ausrüstung erfüllt die Europäischen EMC-Bestimmungen für die Verwendung in folgender/folgenden
Umgebung(en):
Wohngegenden
Gewerbegebiete
Leichtindustriegebiete
(Diese Ausrüstung erfüllt die Bestimmungen der Norm EN55022, Klasse B.)
For Users in Japan
For Users in Korea
Declaration of Conformity
Trade Name: SONY
Model No.: SDZ-S100, SDZ-S130
Responsible Party: Sony Electronics Inc.
Address: 16530 Via Esprillo San Diego, CA. 92127 U.S.A.
Telephone No.: 858-942-2230
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
5
Table of Contents
Chapter 1 Introduction
Overview.......................................................................7
S-AIT Technology........................................................7
Product Features .........................................................8
Compatible Cartridges ................................................9
Data Cartridges ...............................................................9
Cleaning Cartridges.........................................................9
Supported Software ....................................................9
Components and Functions.....................................10
Front..............................................................................10
Rear ...............................................................................13
Bottom...........................................................................15
About the label...........................................................16
Chapter 2 Installation
Overview.....................................................................17
Unpacking ..................................................................17
Package Contents .....................................................18
Preparing the Host Computer ..................................18
Setting the DIP Switches ..........................................19
If necessary, change the settings as follows..................19
Setting the SCSI ID (SDZ-S100 only) .......................22
Setting the Loop ID (SDZ-S130 only).......................23
Installing the S-AIT Tape Drive Unit.........................25
Connecting the Power Cable....................................26
Installing Device Drivers...........................................26
Connecting the SCSI Bus Cable
(SDZ-S100 only) ..................................................27
Connecting the Optical Fiber Cable for
Fibre Channel (SDZ-S130 only) ........................29
Configuring the S-AIT Tape Drive Unit to
the Host ...............................................................30
Chapter 3 Operation
Overview.....................................................................31
Turning the Unit On or Off........................................31
Turning On the Unit......................................................31
Turning Off the Unit .....................................................33
Preparing Cartridges.................................................33
Inserting a Cartridge .................................................33
Removing a Cartridge ...............................................34
6
Chapter 4 Using the Media
Compatible Cartridges ..............................................35
Data Cartridge............................................................35
Components and Functions...........................................36
Setting the Write-protect Switch ..............................38
Cleaning Cartridge ....................................................38
Handling Cartridges ..................................................39
Usage, Storage, and Transport Environmental
Specifications .....................................................40
Appendix
Head Cleaning............................................................41
Changing the Air Filter Unit......................................42
Hardware Reset .........................................................43
Updating the Firmware..............................................43
Taking Care of the Unit .............................................43
Safety ............................................................................43
Avoiding Damage .........................................................44
Troubleshooting ........................................................45
Specifications ............................................................47
Performance ..................................................................47
Environmental Specifications .......................................47
Power Specifications/Miscellaneous.............................48
Options.......................................................................48
Index ...........................................................................49
© 2003 Sony Corporation. All rights reserved.
Trademarks
Sony, Advanced Intelligent Tape, and Super Advanced Intelligent Tape are trademarks or registered trademarks of Sony
Corporation in this country, other countries, or both.
Other product names are trademarks or registered trademarks of their respective owners in this country, other countries,
or both.
7
Chapter 1 Introduction
Chapter
1
Introduction
Overview
The S-AIT Tape Drive Unit is a tape streamer that makes use of “S-AIT” (Super
Advanced Intelligent Tape) technology. The S-AIT drive stores large amounts
of image data on a single half-inch tape cartridge, making it the industry's
highest capacity tape drive.
S-AIT Technology
Helical Scan Recording Technology
Helical scan technology, based on a very stable rotating drum/head platform,
permits accurate and reliable data recording at very high track densities. This
efficient packing density provides the industry’s leading, space-efficient
solution.
Advanced Metal Evaporated (AME) Tape
S-AIT media is based on AME technology. This technology represents the
culmination of over 50 years of Sony innovation and experience in magnetic
tape technology. The AME tape formulation, with diamond-like carbon coating,
offers an extraordinary durability and reliability, up to 30,000 media passes, and
an estimated media archival life of up to 30 years.
Remote Memory in Cassette (R-MIC)
The non-volatile R-MIC chip built into the data cartridge provides quick media
loads and allows fast searches of data. The R-MIC chip contains the tape’s
system log, search map and user-definable information, allowing the drive to
advance at high speed directly to any file on the tape.
Reliability
The reliability of the S-AIT drive is in part the due to its innovative features,
such as its automatic head cleaning system and effective “leader block” tape
threading system with simplified tape load path. The drive cooling system is
also isolated from the sealed tape mechanism, thereby preventing airborne
contaminants from entering the tape path and affecting sensitive components.
8
Chapter 1 Introduction
Product Features
Two models of S-AIT Tape Drive Units are available according to the type of
interface of your host computer.
SDZ-S100
Uses the Ultra 160 Wide Low Voltage Differential/Single-Ended (LVD/SE)
SCSI
SDZ-S130
Uses 2 Gbps Fibre Channel interface
Common Features
Native storage capacity of 500 GB per cartridge (1.3 TB at 2.6:1 compression)
with the S-AIT data cartridge SAIT1-500.
Native sustained data transfer rate of 30 MB per second.
High data reliability with the Read After Write and Fragment Rewrite
functions, and the three levels of Error Correction Code (ECC).
Possibility to enable and disable the Read After Write (RAW) function.
High-speed search and tape rewind.
Supports variable and fixed record length.
72 MB buffer memory.
Very compact design that allows you to set two units side by side on a 19-inch
rack (2U height).
Sealed mechanism with the front door and the air filter.
Very easy to change the air filter.
Half transparent front panel through which you can verify the cartridge even
when the door is closed.
Sleek and elegant design.
Features of the SDZ-S100 (SCSI model)
Ultra 160 SCSI LVD/SE interface is fully supported for host computer access.
Burst data transfer rate of 160 MB per second, synchronous.
Supports SCSI disconnection and arbitration.
Features of the SDZ-S130
(Fibre Channel Interface model)
2 Gbps Fibre Channel interface.
200 MB per second burst data transfer rate.
Private Loop, Public Loop, Point-to-Point, and Switched Fabric topologies.
Full-duplex transfers.
FCP2 support.
Class of service: Class 3
9
Chapter 1 Introduction
Compatible Cartridges
Data Cartridges
Tape cartridges used with the S-AIT Tape Drive Unit must be marked with the
SAIT-1 logo.
Caution
Only use cartridges designed specifically for S-AIT.
Cleaning Cartridges
To clean the read/write heads, use the S-AIT Cleaning Cartridge. For details
about cleaning, see “Head Cleaning” on page 41.
Supported Software
For details about software that can be used with the S-AIT Tape Drive Unit and
supported operating systems, contact your dealer.
SAIT-1 logo
10
Chapter 1 Introduction
Components and Functions
Front
A Front Door
Used to protect the front of the unit. Press the DOOR button to unlock and open
the door when inserting or removing cartridges.
Note
Even when the front door is closed and a cartridge is ejected by software, the
cartridge does not come in contact with the door. You can therefore keep the
door closed except when inserting or removing cartridges to minimize any
contamination from airborne particles.
B DOOR Button
Press to open the front door.
TA PE
MOTION
DRIVE
ERROR
TA PE
ERROR
CLEANING
REQUEST
OPEN
11
Chapter 1 Introduction
Front door opened
A Power Switch
Press this switch to turn the S-AIT Tape Drive Unit on or off. When you restart
the unit, be sure to wait at least 10 seconds before turning it on again.
B POWER Indicator
Lights green when the unit is on. When it flashes, the cooling fan of the unit may
be malfunctioning. If this is the case, verify that the cooling fan on the rear is
operating normally. If it is not, contact your dealer.
C Cartridge Slot
Used to insert and remove cartridges.
D Eject Button
Push to manually eject cartridges from the unit. The unit ejects cleaning
cartridges automatically.
E CLEANING REQUEST Indicator
Flashes yellow when the read/write heads need cleaning. For details about
cleaning, see “Head Cleaning” on page 41.
F TAPE ERROR Indicator
Flashes or lights orange when media errors occur. When media warnings occur,
the indicator flashes yellow. In this case, copy data to another cartridge.
G DRIVE ERROR Indicator
Flashes orange or yellow when drive errors occur.
H TAPE MOTION Indicator
Lights when you insert cartridges. The color of the indicator, shows whether the
cartridge is write-protected. Moreover, when the unit is operating, the indicator
flashes. The color of the flashing indicator shows the status of the unit.
I Hardware Reset Hole
Used to reset the unit in case of emergency. Using the emergency reset hole
when reading or writing data may damage your data, therefore this procedure
should only be used for maintenance purposes.
456789
1 2 3
12
Chapter 1 Introduction
Drive Status
The indicators of the S-AIT Tape Drive Unit show the status of the unit. This
status is indicated by a combination of colors (green, orange, or yellow), and
whether the indicators are lit or flashing. Refer to the table below for
explanations about the meaning of indicator activity.
Note
When you turn on the unit or reset it, all the indicators light green for about half
a second. They then flash repeatedly yellow from left to right for about 3
seconds, indicating that the unit is performing a self-diagnostic.
TAPE MOTION DRIVE ERROR TAPE ERROR
CLEANING
REQUEST
All green,
flashing
Firmware update
All green, lit
Ejection inhibited (only when pressing the eject button)
Orange,
flashing
Tape being
accessed (write)
Drive error Media error Cleaning error
Orange, lit
⎯⎯Media error
Yellow,
flashing
Tape being
accessed
(search)
Drive error Media warning Cleaning request
Yellow, lit
Tape loaded
(write-protected)
⎯⎯Cleaning
Green,
flashing
Tape being
accessed (read)
⎯⎯⎯
Green, lit
Tape loaded
(write-enabled)
⎯⎯⎯
Off
No tape No drive error No media error
No cleaning
request
13
Chapter 1 Introduction
Rear
SDZ-S100
A SCSI ID Switch
Used to set the SCSI ID of the S-AIT Tape Drive Unit. Upon shipment, the SCSI
ID is 0. For details, see “Setting the SCSI ID (SDZ-S100 only)” on page 22.
B RS-232C Connector
For service use only. You do not normally need to use this connector.
C Cooling Fan and Ventilation Holes
Be careful not to block the ventilation holes. If you do, the unit may overheat,
resulting in damage.
D AC IN Connector
Connect the power cable appropriate for your country to this connector.
E Ventilation Holes
Be careful not to block the ventilation holes. If you do, the drive in the unit may
overheat, resulting in damage.
F SCSI Connector 1, 7 SCSI Connector 2
Connect the SCSI bus cable to this connector. For details about connection, see
“Connecting the SCSI Bus Cable (SDZ-S100 only)” on page 27.
14
Chapter 1 Introduction
SDZ-S130
A RS-232C Connector
For service use only. You do not normally need to use this connector.
B Cooling Fan and Ventilation Holes
Be careful not to block the ventilation holes. If you do, the unit may overheat,
resulting in damage.
C AC IN Connector
Connect the power cable appropriate for your country to this connector.
D Ventilation Holes
Be careful not to block the ventilation holes. If you do, the drive in the unit may
overheat, resulting in damage.
E FC Status Indicator
When the fibre channel connection is normal, the indicator is off. When the unit
is communicating with the host computer, this indicator lights green. When
there is a connection error, the indicator lights orange. In this case, reconnect the
cable or change it if necessary.
F Loop ID Jumpers
These jumpers are functional when the topology is arbitrated loop. For details,
see “Setting the Loop ID (SDZ-S130 only)” on page 23.
G Fibre Channel Connector
Connect the optical fiber cable for Fibre Channel. For details about connection,
see “Connecting the Optical Fiber Cable for Fibre Channel (SDZ-S130 only)”
on page 29.
1 2
346 57
15
Chapter 1 Introduction
Bottom
A Access Cover for Service Use
Do not open this cover. For service use only.
B Dip Switch Access Cover
If you need to change the data compression settings, remove this cover to
change the DIP switch settings. For details about setting the DIP switches, see
“Setting the DIP Switches” on page 19.
C Air Filter Unit
Be careful not to block the ventilation holes of the air filter unit. If you do, the
S-AIT Tape Drive Unit may overheat, resulting in damage. Moreover,
periodically clean the air filter unit with a vacuum cleaner (monthly cleanings
recommended) and replace it yearly. For details about how to replace the air
filter unit, see “Changing the Air Filter Unit” on page 42.
1
2
3
16
Chapter 1 Introduction
About the label
A Model number
The model number is located on the bottom of the unit, together with the serial
number.
Refer to the model and serial numbers on the label when seeking technical
support.
B Serial number
The serial number is located on the bottom of the unit, together with the model
number.
Refer to the serial and model numbers on the label when seeking technical
support.
C Number returned to the interface command
The number, which is returned to the interface command, is located on the rear
of the unit. This is the serial number reported by the application software you
use.
1
2 3
Chapter 2 Installation
17
Chapter
2
Installation
Overview
This chapter describes the general procedures for positioning the S-AIT Tape
Drive Unit, connecting it to the host computer, and turning it on. This chapter
also describes initial setup. Installation and setup procedures may vary slightly
depending on your system.
Unpacking
Note
You will need the box and packing materials if you wish to move or transport
the unit. Retain them for future use.
1
Remove the unit from the box as indicated below.
Remove the packing materials, such as plastic covers and tapes.
2
Inspect the unit for shipping damage.
If there is damage, do not use the unit. Report the damage immediately by
contacting your dealer.
18
Chapter 2 Installation
Package Contents
After opening the package, make sure that all the following items are present.
Contact your dealer if anything is missing.
S-AIT Tape Drive Unit (1)
Operating Instructions (1)
Note
In addition to the above, other items may be included in the package.
Preparing the Host Computer
Prepare the host computer before installing the S-AIT Tape Drive Unit.
1
Make sure that a SCSI host adapter card or Fibre Channel host bus adapter
(FC HBA) is installed in the host computer.
2
Install all the necessary software supporting the unit on the host computer.
For details about the software that can be used with the S-AIT Tape Drive
Unit and supported operating systems, contact your dealer.
19
Chapter 2 Installation
Setting the DIP Switches
By setting the DIP switches at the bottom of the S-AIT Tape Drive Unit, you
can:
Choose whether to compress the data when recording.
Choose whether the host can control data compression.
The default settings of the DIP switches is as follows.
DC Control-1: ON
Compression is enabled.
DC Control-2: OFF
The host can control compression.
If necessary, change the settings as follows
Caution
Before removing the access cover to change DIP switch settings of the S-AIT
Tape Drive Unit, turn off the unit and disconnect the power cable.
1
Make sure that the unit is off.
2
Remove the two screws with a screwdriver and remove the access cover.
Screw
Access cover
DIP switches
20
Chapter 2 Installation
3
Change the settings with a pointed object.
Each DIP switch is defined in the tables below.
SWA settings (SDZ-S100)
SW1 Custom-1 OFF
SW2 Block Size ON
SW3 Immediate WFM OFF
SW4 Custom-4 OFF
SW5 Reserved OFF
SW6 Reserved OFF
SW7 DC Control-1 ON
SW8 DC Control-2 OFF
SWA settings (SDZ-S130)
SW1 UA Control ON
SW2 Block Size ON
SW3 Immediate WFM OFF
SW4 Custom-4 OFF
SW5 Reserved OFF
SW6 Reserved OFF
SW7 DC Control-1 ON
SW8 DC Control-2 OFF
SWB settings (Common)
SW1 Reserved OFF
SW2 Reserved OFF
SW3 Reserved OFF
SW4 Reserved OFF
SW5 Reserved OFF
SW6 Reserved OFF
SW7 Reserved OFF
SW8 Reserved OFF
DC
Control-1
DC
Control-2
Definition
OFF OFF
Compression disabled. The host can control
compression.
OFF ON
Compression disabled. The host cannot control
compression.
ON OFF
Compression enabled. The host can control
compression.
ON ON
Compression enabled. The host cannot control
compression.
ON
SWA (SDZ-S100)
OFF
12345678
ON
SWA (SDZ-S130)
OFF
12345678
ON
SWB
OFF
12345678
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64

Sony SDZ-S100 User manual

Category
Blank data tapes
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI