  • Hello! I am an AI chatbot trained to assist you with the American Standard 7222.712 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Installation
Instructions
U S 6 0 4 0 6 R E V. 1. 2
Certified to comply with ANSI A112.18.1M
FINISHED
WALL
1-1/4 DIA HOLE
4
TOP OF
TUB RIM
OPTIONAL TO FINISHED
FLOOR USUALLY
BETWEEN 65'' AND 78''
1/2" N.P.T.
SHOWER ARM
BOTTOM OF TUB
ROUGHING-IN DIMENSIONS
5 REF.
7 REF.
18 OPTIONAL
NOTE: NO CONCEALED PIPING FURNISHED
2" MIN.
3-1/4" MAX.
74 FOR HEAD CLEARANCE
U.S. Patent No. 5,819,789
(2) 1-13/16" DIA. HOLES
FOR VALVES ON 8"
CENTERS (1) 1-13/16"
DIA. HOLE FOR CENTER
TRANSFER VALVE
CROSS
BRACE
1-3/4
TYP.
1-3/4
UNION INLET
1/2"-14 N.P.T.
1/2" N.P.T. TO
SHOWER
Turn off hot and cold water
supplies before beginning.
CAUTION
1
ROUGHING-IN
SHOWER AND SPOUT
2
3
4
1
5
UNION
SWIVEL
"HOT"
"COLD"
7
COUPLING
NUT
IMPORTANT: DO NOT REMOVE PLASTER GUARDS (2) UNTIL STEP 2.
(SHR)
6
Recommended Tools
*Hex key Supplied with Fitting
Flat Blade Screwdriver
Adjustable Wrench
Channel Locks
Plumbers' Putty or Caulking
Phillips Screwdriver
TWO HANDLE BATH/SHOWER SET
5-1/8"
REF.
1" MIN.
4"
1/2" COPPER
8
10
9
7220.702
7220.712
7220.722
7220.732
7221.702
7221.712
CROSS
BRACE
"COLD"
"MAX WALL"
PLASTER
GUARD
M
A
X
W
A
L
L
M
I
N
1
-
5
/
8
"
D
E
E
P
M
A
X
W
A
L
L
M
I
N
1
-
5
/
8
"
D
E
E
P
Prepare water supplies per Roughing-in Dimensions. Apply sealing tape
to all threaded connections.
Install VALVE (1) at indicated height and depth. Make sure the outlet marked
"SHR" is pointing upward. Mount VALVE (1) to cross brace with wood screws.
Slip COUPLING NUT over supply pipe and thread UNION SWIVEL to pipe.
Connect HOT
(6) water supply to LEFT valve inlet and COLD (7) water supply
to RIGHT valve inlet.
Prepare SHOWER RISER (4) and ELBOW (3). Connect to TOP outlet, marked
"SHR" of VALVE BODY (1).
Prepare TUB FILLER PIPE (8), ELBOW (10) and roughing-in COPPER PIPE (9).
Connect to BOTTOM outlet of VALVE BODY (1).
Add cross braces to wall structure and secure piping.
Cap NIPPLES (5) and COPPER PIPE (9). Open supply lines and check for leaks.
Remove PLASTER GUARDS (2). Use spline on end of PLASTER GUARD (2) to
open both VALVES and check for leaks.
Close both valves and turn off water supplies. Replace PLASTER GUARDS (2).
Finish wall construction.
Thank you for selecting American-Standard...the benchmark
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--
please read these instructions carefully before you begin.
7221.722
7221.732
7222.702
7222.712
7222.722
7222.732
U S 6 0 4 0 6 R E V. 1. 2
2
INSTALL TRIM (SHOWER AND TUB SPOUT)
NOTE; PROTECT FINISH ON SHOWER AND TUB TRIM WHEN INSTALLING.
To change direction of handle rotation, proceed as follows:
Turn valve to OFF position.
Pull out INDEX CAP and remove
HANDLE SCREW.
Pull out LEVER BALL from HANDLE BASE.
Unscrew HANDLE BASE and remove ADAPTER
Remove SPRING CLIP.
Lift STOP WASHER, turn 90 and replace.
Replace SPRING CLIP.
Reinstall HANDLE. (See step three).
SPRING
CLIP
STOP
WASHER
90˚
Remove PLASTER GUARDS (1) from valve body by unthreading and pulling off.
Apply sealing tape to threads on both ends of SHOWER ARM (2) and install
SHOWER ARM (2) with SHOWER ESCUTCHEON (3) into shower elbow.
Thread SHOWER HEAD (4) onto end of SHOWER ARM (2). Push SHOWER
ESCUTCHEON (3) against finished wall. Tighten SET SCREW (5).
Remove rough-in nipple from shower elbow.
Remove pipe cap from tub filler pipe. Prepare TUB FILLER PIPE, ELBOW and
1/2" COPPER PIPE. Final length of COPPER PIPE to be 1" from
finished wall.
Push SPOUT ESCUTCHEON (6) onto filler pipe flush against finished wall.
Push TUB SPOUT (7) onto filler pipe until tight against SPOUT ESCUTCHEON (6).
Tighten clamp screw in SPOUT (7) to secure TUB SPOUT (7).
4
1
1
2
4
6
7
7
8
6
5
2
3
ROUGH-IN
NIPPLE
SHOWER
ELBOW
ROUGH-IN
NIPPLE
7
5
6
PIPE CAP
CLAMP SCREW
M
I
N
U
S
I
8
M
M
M
A
X
I
M
U
M
M
I
N
U
S
I
8
M
M
M
A
X
I
M
U
M
1"
6
3
4
FINISHING INSTALLATION
SERVICE
If spout drips, operate handles several times from OFF to ON
position. Do not force - handles turn only 90 .
TEST INSTALLED FAUCET
5
Turn HANDLES into "off" position.
Turn on water supplies and check all connections for leaks.
Operate both HANDLES to flush water lines thoroughly.
Check SHOWER HEAD and SPOUT connections for leaks. Operate
DIVERTER for proper operation. Turn handles into OFF position.
Turn VALVE into OFF position.
Push ADAPTER (1) into HANDLE BASE (9)
in a way that the male square on the
ADAPTER (1) fits in
he female square of the
HANDLE BASE (9).
Push HANDLE (9) and ADAPTER (1)
onto VALVE STEM (3).
Check alignment, if not
satisfactory aligned;
Turn VALVE into OFF position.
Push ADAPTER (1) into HANDLE
BASE (2) in a way that the male
square on the ADAPTER (1) fits in
the female square of the
HANDLE BASE (2).
Push HANDLE BASE (2) and
ADAPTER (1) onto VALVE STEM (3).
Push CROSS HANDLE (4, 5) onto
HANDLE BASE (2).
Install HANDLE SCREW (6) and tighten.
Push INDEX CAP (7, 8) in top of
CROSS HANDLE.
FOR LEVER HANDLES
FOR CROSS HANDLES
Push out ADAPTER (1) carefully.
Turn ADAPTER (1) either 45˚ or
90˚ so that male square on
ADAPTER (1) catches different
female square in HANDLE BASE (9).
Assemble and tighten HANDLE SCREW (6).
Push INDEX CAP (7) in top of HANDLE (9).
INSTALL HANDLES
Install SHOWER ARM, SHOWER ARM FLANGE and TUB SPOUT.
Remove caps from roughing-in nipples.
Remove PLASTER GUARD by turning counter-clockwise and pulling.
If VALVE BODY is roughed in SHALLOW (more than 2-1/2")
screw SLEEVE in ESCUTCHEON facing front of ESCUTCHEON.
If VALVE BODY is roughed in DEEP (less than2-1/2")
screw SLEEVE in ESCUTCHEON facing back of ESCUTCHEON.
Assemble RUBBER RING to ESCUTCHEON.
Screw ESCUTCHEON and SLEEVE onto VALVE COVER against wall.
DEEP ROUGH-IN
LESS THAN
2-1/2"
SLEEVE
SLEEVE
MORE THAN
2-1/2"
ESCUTCHEON
RUBBER
RING
SHALLOW ROUGH-IN
VALVE
BODY
METAL
LEVER
VALVE
COVER
9
3
6
DO: SIMPLY RINSE THE PRODUCT CLEAN
WITH CLEAR WATER. DRY WITH A SOFT
COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT
WITH SOAPS, ACID, POLISH, ABRASIVES,
HARSH CLEANERS, OR A CLOTH WITH A
COARSE SURFACE.
CARE:
923002-0070A
ADAPTER
060453-YYY0A
ESCUTCHEON KIT
918428-0070A
HANDLE SCREW
918428-0070A
HANDLE SCREW
916503-YYY0A
LEVER HANDLE BASE
021470-YYY0A
INDEX CAP
021470-YYY0A
INDEX
CAP
U S 6 0 4 0 6 R E V. 1. 2
MODEL NUMBERS
TWO HANDLE
BATH/SHOWER
CHROME 002
Replace the "YYY" with
appropriate finish code
060351-YYY0A
SHOWER ARM
AND FLANGE
M962341-0070A
GROUND
JOINT INLET
994053-0070A
CARTRIDGE
060409-YYY0A
DIVERTER SPOUT (SLIP-ON)
907520-YYY0A
SPOUT ESCUTCHEON
M953569-YYY0A
SHOWER HEAD
908501-YYY0A
BASE CROSS
HANDLE
013311-YYY0A
INDEX CAP
042692-0070A
PORCELAIN CROSS
HANDLE
013307-YYY0A
METAL CROSS HANDLE
060354-YYY0A
METAL LEVER HANDLE
0060353-YYY0A
PORCELAIN
LEVER HANDLE
021470-YYY0A
END CAP
7220.702
7220.712
7220.722
7220.732
7221.702
7221.712
7221.722
7221.732
7222.702
7222.712
7222.722
7222.732
For toll-free information and answers to your questions, call:
1-800-442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-12-00
Product names listed herein are trademarks of American Standard Inc.
© AS America, Inc. 2008
HOT LINE FOR HELP
/