Leviton 2206 User manual

Type
User manual

This manual is also suitable for

llkUW-OnK&mOU
RESIDENTIAL POWERLINE
CARRIER COMPONENTS
SINGLE POLE SWITCH MODULE
INSTALLATION INSTRUCTIONS
&
Wiring Diagram
Cat. No. 6291
mmn
TO BE INSTALLED
AND/OR
USED IN ACCORDANCE WITH
APPROPRIATE ELECTRICAL CODES AND
REGULATIONS.
RATING:
20A-120V/
60Hz
AC ONLY
Minimum Voltage:
112V
Maximum Voltage:
138V
Maximum number of Modules per circult: 10
ENGINEERING
DATA:
Input
Signal
121 kHz carrier signal superimposed
on a
12OV
AC power line.
Mlnlmum
Signal
Strength:
100mV.
Ambient
Operating Temperature: Minimum F
(-18°C)
to Maxlmum 104°F (40°C).
Ambient
Humidity:
0 to 90% RH, non-condensing.
DESCRIPTION:
This Wall Switch Module is designed for use with
Levlton
Decora
Electronic Control (DEC) Powerline
Carder Components. It functions as a remote
control
switching
device which responds to ON/OFF
and ALL LIGHTS ON/OFF commands, from one or
more DEC controllers remotely located from the
module. The switch module can also be operated
manually as a standard type wall switch.
2
The module may be set to any of the 256 address
codes, selected at the time of installation. The
desired address Is set by removing the touchplate
and selecting letter and number codes with a small
blade screwdriver. The module is equipped with
back wire terminals and installs easily in a
standard
wall box. It is
suitable
for incandescent and
fluores-
cent lighting, as well as switch controlled appliance
when Dimming Is not desired.
The Cat. No.
6291
is assembled as white and an
ivory color conversion kit is provlded.
This
product
fits any color
Decora
Wallplate (sold separately).
Additional color conversion
kits
are available.
SAVE THIS INSTRUCTION
SHEET!
IT CONTAINS IMPORTANT TECHNICAL DATA,
TESTlNG,
AND TROUBLE
SHOOTING
INFORMA-
TION
WHICH WILL BE USEFUL AFTER
INSTAL-
LATION
IS COMPLETE.
IMPORTANT: Unlike standard single pole wall
switches the Cat. No. 6291 also requires a neutral
(white)
wire
for operation.
Home Automation Systems, Inc. (800) SMART-HOME (949) 221-9200 http://smarthome.com
APPLICATIONS:
Decora
Electronic Controls will not control lighting
that is used with low voltage or high frequency
transformers, nor high pressure discharge lamps
(HID lighting). This
includes
mercury vapor, sodium
vapor, and
metal
halide
lamps.
DEC components
can control:
l
Low pressure dischare lamps (fluorescent)
(ON/OFF only)
-
use
d
at. Nos. 6291 and 6293
l
120 Volt quartz lamps can be dimmed or
brightened
-
use Cat. Nos. 6381 and 6383
l
Low
volta
!l
e lighting can be controlled
provided t
e
lighting
system operates with a
80 Hz transformer
-
(ON/OFF only) use Cat.
Nos.
8291, 6293, 6227
and 6280 (DIMMING)
use Cat. Nos. 6381-U and 6290
If a power interruption should
occur
while the 6291 is
ON the LOAD will remain ON when power is re-
stored.
4
IMPORTANT NOTICE
The
Leviton
power line carrier signal is designed to
provide the greatest signal integrity and noise
immunity possible. However, in some environments
intense electrical noise can cause interference with
the signal.
Leviton
has developed hardware and techniques for
overcoming this interference when properly applied.
It is the responsibility of the specifier/installer
to
test
for signal strength and the presence of noise using
Leviton
test equipment Cat. Nos. 6385 (Signal Test
Transmitter) and 6386 (Signal Strength Indicator)
and to properly
apply
signal coupling and noise-
reduction equipment according to the guidelines
provided in the DEC Technical Manual and the DEC
Troubleshooting Guide.
Leviton
specifically
denies
any warranty of perfor-
mance, stated or implied, where electrical noise
interference exists at the time of installation, or
subsequent to Installation by the addition of noise-
producing devices or equipment, or where these
components have been installed for non-residential
applications.
5
INSTALLATION
INSTRUCTIONS
1. WARNING: TO AVOID FIRE, SHOCK, OR
DEATH; TURN OFF POWER AT CIRCUIT
BREAKER OR FUSE. TEST THAT POWER IS
OFF-BEFORE
WIRING!
Use this device only with
copper or co
use only de
VP
per
clad
wire.
With
aluminum wire
CBS
marked
CO/ALR.
REMOVE
BULB(S) FROM FIXTURE. Read all
instruc-
tions carefully. If you do not
understand these
instructlons, consult
a
qualified
electrlclan
2.
Remove and discard existing
switch
and
wallplate,
if applicable.
3. Remove 1/2” insulation from ends of branch
drcuft wires
to expose bare copper.
4. Connect
drcuft wires to switch module per wiring
diagram as follows: Insert wires into round
backwfre holes. Firmly tlghten all terminal screws.
;FrtZx$two
(2) drcuft
wires
can be connected to
5. Mount
switch
module In wall box using two
screws provfded
8.
Usi
“a
a small blade
screwdriver,
remove the
Tout
Plate (front cover) by pryin it off at the
bottom.
6
WIRING DIAGRAM
For Cal. No. 6291
Single Pole Switch Module
Home Automation Systems, Inc. (800) SMART-HOME (949) 221-9200 http://smarthome.com
7.
Using
the same screwdriver, set the House Code
Dial
(RED) to the chosen Letter and the Unit Code
Dial
(BLACK) to the chosen Number, thus pro-
gramming the unit
with
the desired address code.
8.
If
it is desirable to change the color of the device,
do so now by following the “Color Conversion
Procedure”. If
not,
remount the Touch Plate by
pressing
it into
position.
Mount
Decora
Wallplate
(sold separately).
0. Replace bulb(s)
in
lighting
fixture.
Restore power
at circuit breaker or fuse. INSTALLATION IS
COMPLETE. PROCEED TO TESTING.
If a power interruption should occur while the 6291
is ON the LOAD will remain ON when power is
restored.
Transmit an ALL LIGHTS ON control to the
module from an appropriately coded controller.
It
(and all other devices on that House code)
should respond by
turning
its assigned
Load ON.
Transmit an ALL OFF command from an
appropriately coded controiier. It
should
respond by turning its assigned Load OFF.
TESTING
(Performed
directly
after installation)
With
the Cat. No. 6291 properly wired and powered,
PERFORMANCE
CHECKLIST.
The DEC Single Pole Module
Switch
should be
operating
properly.
If not, proceed to
PERFECT
tap
the
switch
plate
several
times
to ensure that the
module is turning its
load
on and off in response to
manual
control. Next,
use
the Cat. No. 6320 Table
Top Controller, or other controller, to check
for
the
proper
switch
module
operation
as
follows
(leaving
the load ON, manually):
l
Transmit an OFF command to the module. it
should
respond by turning its assigned Load
OFF
9
COLOR CONVERSION PROCEDURE
The
color of
this
be
changed to
suit
your Interior design
requirements.
Simply get a color
conversion kit of the
appropriate
cclor
from your Levlton
distributor
or use
the one provided,
and proceed as
follows:
Cat.
No.
6291 can
-ToI
1. The trim frame bordering the touch plate has
notches on its sides. Place the tip of a
small-
bladed
screwdriver
under a notch and gently pry
off the trim frame.
2.
The touch plate has a notch
along
its bottom edge
which
can be seen once the trim frame has been
removed. Place the screwdriver tip in this
notch and gently pry
off
the touch
plate.
10
3. Take the new touch plate and gently press it into
place until it seats properly with a click.
4. Take the new trim frame and position it properly
around the touch plate. Notice that the trim frame
has a cut-out for the indicator light.
With the trim
frame properly
positioned,
gently press it into
place until it seats properly with a click. The color
conversion is complete.
PERFECT PERFORMANCE CHECKLIST
if the 6291 seems to be functioning improperly
confirm that the:
1. POWER IS OFF AT
CIRCUIT
BREAKER OR
FUSE. Check that the Module is wired EXACTLY
as shown in the Wiring Diagram. Restore power
before proceeding.
2. Module is being supplied from a
120V/
60Hz
AC
source ONLY.
3. Load being controlled is in proper working order.
Local switch, ON. (Check for burned-out bulbs)
4. Load being controlled does not exceed the
20 Amp module limit.
11
Home Automation Systems, Inc. (800) SMART-HOME (949) 221-9200 http://smarthome.com
5. Module’s Letter and Number codes are set
correctly- that they match the codes set in the
Controller.
6. Confirm that the controller Is powered.
IMPORTANT:
If,
after checking Items 1 through 6,
the module
still
does not operate properly, the
fault may not
lie
with
the module itself.Follow
steps 7 and 8 to
identify
the source of the problem.
7. Set the controller to transmit address P1..Using a
Signal Strength Indicator, Cat. No. 6386, plugged
in at the location of the controller, Confirm that the
controller is transmitting a
minimum
reading of 2
volts of command
signal
at the HI-RANGE setting.
If the signal strength Is less than 2 volts, have
controller checked.
6. Check for adequate command signal at the
module location as follows:
a) Plug the Cat. No. 6385 Signal Test Transmitter
into a receptacle on the same circuit.
b) Using the Cat. No. 6386
Signal
Strength
Indicator at the module location, check the
command signal amplitude. Signal strength
must be 1
00mV
minlmum.
If there is less
than
DEC Components
are
for
RESIDENTIAL USE ONLY.
installation
for
any
other application, voids any warranty,
stated
or
implied.
1
1
OOmV
of signal present, it may be necessary
to couple both legs of the
120/240
volt power
service at the entrance panel using Cat. No.
6299 Signal Btfdge.
c) If the Yellow ERROR CONDITION indicator is
lit, there is electrical noise present on the AC
line which is interfering with proper module
operation. The source of the noise must be
identified and either filtered out or eliminated.
Consult the DEC Technical Manual and DEC
Troubleshooting Guide.
I’
I[
Home Automation Systems, Inc. (800) SMART-HOME
(949) 221-9200 http://smarthome.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Leviton 2206 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI