Prostat Q007-T User manual

  • Hello! I've reviewed the instruction sheet for the Prostat Qube Q007B Common Point Ground Connector. This document provides guidance on how to properly set up the device, disconnect it, and verify its continuity. It emphasizes the importance of testing the electrical outlet before use according to ANSI/ESD S6.1 standard. I am ready to address your questions about this product and its usage.
  • What should I use to test the electrical outlet before using the Q007B?
    What is the first step in disconnecting from the Q007B?
    What type of multimeter should be used to check the continuity of the Q007B?
INSTRUCTION SHEET
Q007B COMMON POINT
GROUND CONNECTOR
The Prostat Qube™ replaces expensive electrical ground circuit tes-
ters and indicators with a convenient, cost eecve means to con-
nect vital ESD controls to grounded electrical outlets. Use the Qube
to ground workstaons, mats, wrist strap testers, instruments, and
other ESD products to an approved pre-tested facility electrical
ground. It consists of a heavy duty dual banana receptacle frame
encased in re retardant ABS with a solid brass grounding pin.
CAUTION: TEST YOUR ELECTRICAL OUTLET
BEFORE USE PER ANSI/ESD S6.1
SETTING UP THE Q007B
Step 1: Using your PGT-61-164 SureTest® Circuit Analyzer, test your
electrical outlet (Figure 1).
Step 2: Insert the Q007B into the tested outlet (Figure 2).
Step 3: Insert your mat ground into the Qube Q007B (Figure 3).
Step 4: Insert Wrist Strap into the mat ground receptacle (Figure 4).
2 3 4
1
Please read the following instrucons carefully.
For technical support call 1-855-STATIC1 (782-8421)
or email techsupport@prostatcorp.com
DISCONNECTING FROM THE Q007B
Step 1: Remove your Wrist Strap from the mat ground receptacle (Figure 1).
Step 2: Remove the Q007B from the electrical outlet (Figure 2).
Step 3: Remove the mat ground from the plug (Figure 3).
1 2 3
CHECKING THE CONTINUITY OF THE Q007B
Step 1: Use a high end mulmeter capable of measuring < 1.0 Ohm
(Figure 1).
Step 2: Test the resistance between the 3 input jacks (Figure 2).
Step 3: Clip one lead of your mulmeter to the brass pin (Figure 3).
Step 4: Insert the other mulmeter lead into one input jack.
Step 5: Insert the other mulmeter leads into the second input jack
(Figure 4). Repeat for the third input jack.
2 3 4
1
Prostat Corporaon
1072 Tower Lane
Bensenville, IL USA 60106
(630) 238-8883 Fax (630) 238-9717
hp://www.prostatcorp.com/Qube