ECOMAX LE · Edition 12.21 · EN 2
Contents
Contents ......................................2
1 Application ..................................4
1.1 Radiant tube heating ..........................4
1.2 Application examples..........................5
1.3 ECOMAX LE in radiant tube heating .............6
1.3.1 Single ended radiant tube .........................6
1.3.2 No pneumatic ratio control system ..................6
2 Certification .................................8
2.1 Eurasian Customs Union .......................8
3 Mechanical construction ......................9
3.1 Burner body ................................9
3.2 Recuperator ................................9
3.2.1 Ceramic burled tube recuperator ...................9
3.2.2 Metallic recuperator ............................10
3.3 Air guide tube ..............................11
3.4 Gas insert .................................11
4 Function ....................................12
5 Selection ...................................15
5.1 Capacity data ..............................15
5.2 Burner type ................................15
5.3 Burner size ................................15
5.4 Burner length...............................15
5.5 Burner head ...............................15
5.5.1 Use .........................................15
5.5.2 Gas type ....................................16
5.6 Type of heating .............................16
5.7 Selection table..............................16
5.7.1 Type code ....................................16
5.8 Selection table for flue gas connector FLUP .......17
5.8.1 Type code.................................... 17
6 Project planning information ..................18
6.1 Heat design ................................18
6.2 Radiant tubes ..............................19
6.3 Flue gas channelling .........................20
6.4 Flue gas system on the furnace.................21
6.5 Installation .................................22
6.5.1 Heat guard ...................................22
6.6 Flame control ..............................23
6.7 Burner control units and ignition transformers......23
6.7.1 Configuration of burner control unit ................24
6.8 Gas connection.............................26
6.8.1 Component selection...........................26
6.8.2 Gas pressure .................................26
6.9 Air connection ..............................27
6.9.1 Component selection........................... 27
6.9.2 Air pressure ..................................28
6.10 Air flow monitoring ..........................28
6.11 Purge air and cooling air .....................29
6.12 Condition on delivery ........................30
6.13 Increased furnace cooling ....................30
6.14 Connection for additional furnace cooling ........31
6.15 Build up of noise ...........................31
6.16 Emissions ................................31
6.17 Max. flame capacity.........................32
7 Accessories.................................33
7.1 Air flow monitoring ...........................33
7.2 Purge air set................................33
7.3 Flue gas connector FLUP......................34
7.4 Ceramic radiant tube SER-C ...................34
7.5 FlameCone.................................35
7.6 Segmented flame tube SICAFLEX® .............35
7.7 Cruciform spacer ............................36
7.8 Flue gas guide tube FGT set ...................36
7. 9 Pip e wor k ..................................37