3
3.2.FurnaceVariableSpeedMotorElectricalAdjustments ......................................27
3.3.VariableSpeedMotorFurnaceSystemOperations ........................................... 27
3.3.1. Operation ............................................................................................................ 27
3.3.2. IntegratedFurnaceControlW2terminaltoHarmonyIIIzoningsystem
Control ................................................................................................................. 28
3.3.3. InstallationSetupWorksheets ............................................................................. 29
3.3.3.1. SLP98V—Cooling/Heating(Non-HeatPumpApplications) .............. 29
3.3.3.2. SL280V,SL280NV,EL296VandSL297NV—Cooling/Heating
(Non-HeatPump) ................................................................................ 30
3.3.4. ZoneControlOperationinaGasFurnaceSystem ............................................. 31
3.3.4.1. ZoneThermostats ............................................................................... 31
3.3.4.2. BalancePointSetting .......................................................................... 31
3.3.4.3. ZoneMode .......................................................................................... 31
3.3.4.4. Central(Vacation)Mode ..................................................................... 31
3.3.4.5. CoolingOperation ............................................................................... 31
3.3.5. InstallationSetupWorksheetsforHoneywell2-StageIFCControl—Cooling/
Heating(Non-HeatPump) ................................................................................... 32
3.4.FurnaceSystemStart-UpandCheckout ...........................................................33
3.4.1. Start-UptheSystem(AllModels) ........................................................................ 33
3.4.2. Checkouts ........................................................................................................... 33
3.4.2.1. TypicalGasHeatingCheckout(SingleZone) ..................................... 33
3.4.2.2. TypicalGasHeatingCheckout(MultipleZone) ................................... 34
3.4.2.3. TypicalGasHeatingCheckout(CentralMode) ................................... 35
3.5.ZoningSystemwithGasFurnaceTroubleshooting-Option1...........................36
3.5.1. TroubleshootingDiagrams .................................................................................. 36
3.5.2. GasHeatingOperation ....................................................................................... 38
3.5.3. DischargeAirUpperLimitandDifferentialTemperatures ................................... 38
4. Air Handlers ........................................................................... 39
4.1.VariationsonCommonACUnitApplications .....................................................39
4.1.1. Heating/CoolingEquipmentInstallation .............................................................. 39
4.1.2. AirHandlerWiring ............................................................................................... 39
4.1.3. Variations ............................................................................................................ 39
4.2.ElectricalAdjustments ........................................................................................40
4.2.1. CommunicatingIndoorControl ........................................................................... 40
4.2.2. Non-CommunicatingIndoorControl .................................................................... 40
4.2.3. InstallationWorksheets ....................................................................................... 42
4.2.3.1. Cooling/HeatingwithElectricStripHeat(Non-HeatPump) ................ 42
4.2.3.2. HeatPump—ElectricStripHeat ....................................................... 44
4.2.3.3. CoolingOnlyorCoolingwithHotWaterCoil(Non-HeatPump) ......... 46
5. Dual Fuel (Option 3) .............................................................. 48
5.1.ZoneControlSystemWiring-Option3 .............................................................48
5.2.DualFuelSystemStart-UpDefrostTemperatingSensorPlacementand
Checkout ............................................................................................................49
5.2.1. Start-UptheSystem(AllModels) ........................................................................ 49
5.2.2. DefrostTemperatingSensorPlacement ............................................................. 49
5.2.3. Checkouts ........................................................................................................... 50
5.2.3.1. TypicalDualFuelGasHeating(SingleZone) ..................................... 50
5.2.3.2. TypicalDualFuelGasHeating(MultipleZone) .................................. 51
5.2.3.3. TypicalDualFuelGasHeating(CentralMode) .................................. 52
5.3.ZoningSystemwithDualFuelTroubleshooting-Option3 ................................53
5.3.1. TroubleshootingDiagram .................................................................................... 53
5.3.2. DualFuelOperation(BelowBalancePoint) ........................................................ 54
5.3.3. DischargeAirUpperLimitandDifferentialTemperatures ................................... 54
5.3.4. DualFuelOperation(AboveBalancePoint) ....................................................... 55
5.3.5. DefrostOperation ................................................................................................ 55
5.3.6. InstallationSetupWorksheets ............................................................................. 56
5.3.6.1. DualFuel-IndoorUnitHoneywell2-StageIFCControland
HeatPump .......................................................................................... 56
5.3.6.2. DualFuel-SLP98VariableCapacityandHeatPump ........................ 57
5.3.6.3. DualFuel-VariableSpeedSL280V,EL296V,SL297NVand
HeatPump .......................................................................................... 58
6. Troubleshooting .................................................................... 59
6.1.OperationandTroubleshootingIndicators .........................................................59
6.1.1. ZoneControlPanelLEDs ................................................................................... 59
6.1.2. FaultRecallandTimeDelayOverride ................................................................ 60
6.1.3. TimeDelays ........................................................................................................ 60
6.1.4. DischargeAirProbeCheckout(AllSystems) ...................................................... 60
6.1.5. BlowerSpeedCheckout ...................................................................................... 61
6.2.DiagnosticLEDErrorCodes ..............................................................................62
6.3.AirDeliveredByBlower .....................................................................................63
6.3.1. Formulas ............................................................................................................. 63
6.3.2. PIABCalculationWorksheet ............................................................................... 65
7. User Guide ............................................................................. 66
7.1.WhatistheHarmonyIII™zoningsystem? .......................................................66
7.2.WhatdoestheHarmonyIII™zoningsystemconsistof?...................................66
7.3.HowdoIsettheControlCenterSwitches? ......................................................66